Human gut-on-a-chip inhabited by microbial flora that experiences intestinal peristalsis-like motions and flow
The DOI matches its Crossref record; 65 of the 65 references it cites were found in a registry or an index.
Abstract
Development of an in vitro living cell-based model of the intestine that mimics the mechanical, structural, absorptive, transport and pathophysiological properties of the human gut along with its crucial microbial symbionts could accelerate pharmaceutical development, and potentially replace animal testing. Here, we describe a biomimetic 'human gut-on-a-chip' microdevice composed of two microfluidic channels separated by a porous flexible membrane coated with extracellular matrix (ECM) and lined by human intestinal epithelial (Caco-2) cells that mimics the complex structure and physiology of living intestine. The gut microenvironment is recreated by flowing fluid at a low rate (30 μL h(-1)) producing low shear stress (0.02 dyne cm(-2)) over the microchannels, and by exerting cyclic strain (10%; 0.15 Hz) that mimics physiological peristaltic motions. Under these conditions, a columnar epithelium develops that polarizes rapidly, spontaneously grows into folds that recapitulate the structure of intestinal villi, and forms a high integrity barrier to small molecules that better mimics whole intestine than cells in cultured in static Transwell models. In addition, a normal intestinal microbe (Lactobacillus rhamnosus GG) can be successfully co-cultured for extended periods (>1 week) on the luminal surface of the cultured epithelium without compromising epithelial cell viability, and this actually improves barrier function as previously observed in humans. Thus, this gut-on-a-chip recapitulates multiple dynamic physical and functional features of human intestine that are critical for its function within a controlled microfluidic environment that is amenable for transport, absorption, and toxicity studies, and hence it should have great value for drug testing as well as development of novel intestinal disease models.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“this 2-dimensional (2D) culture format fails to recapitulate physiological 3-dimensional (3D) intestinal cell and tissue morphology or re-establish other key intestinal differentiated functions (eg, mucus production, villi formation, cytochrome P-450-based drug metabolism).”
From Microfluidic Organ-on-a-Chip Models of Human Intestine (2018) · cites this paper as [16]
In the citing paper
“These conventional static models also cannot support the coculture of commensal microbiome with human intestinal cells, which are critical for gut physiology,16 because the bacteria rapidly overgrow and contaminate the human cell cultures within a day.”
From Microfluidic Organ-on-a-Chip Models of Human Intestine (2018) · cites this paper as [16]
In the citing paper
“In fact, barrier function was shown to increase when the intestinal epithelium was cocultured with L rhamnosus GG.16”
From Microfluidic Organ-on-a-Chip Models of Human Intestine (2018) · cites this paper as [16]
In the citing paper
“Importantly, because the Gut Chip has continuous fluid flow, villi formation, and mucus production, it is also possible to coculture living commensal microbes (eg, Lactobacillus rhamnosus GG)16 or the VSL#3 clinical probiotic formulation containing 8 different microbial strains42) in direct contact with the intestinal epithelial cells within the lumen of the parenchymal channel for weeks in vitro”
From Microfluidic Organ-on-a-Chip Models of Human Intestine (2018) · cites this paper as [16]
In the citing paper
“Importantly, the probiotic L rhamnosus GG was shown to increase intestinal barrier function when cocultured in the lumen of the intestinal epithelial channel of the human Gut Chip,16”
From Microfluidic Organ-on-a-Chip Models of Human Intestine (2018) · cites this paper as [16]
5 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Turnbaugh, P. J., Ley, R. E., Hamady, M., Fraser-Liggett, C. M., Knight, R., & Gordon, J. I. (2007) · Nature · doi:10.1038/nature06244 · Cited by 6,091
The gut microbiota shapes intestinal immune responses during health and disease
Round, J. L., & Mazmanian, S. K. (2009) · Nature Reviews Immunology · doi:10.1038/nri2515 · Cited by 5,029
Reconstituting organ-level lung functions on a chip
Huh, D., Matthews, B. D., Mammoto, A., Montoya-Zavala, M., Hsin, H. Y., & Ingber, D. E. (2010) · Science · doi:10.1126/science.1188302 · Cited by 4,250
Self-citationIntestinal mucosal barrier function in health and disease
Turner, J. R. (2009) · Nature reviews. Immunology · doi:10.1038/nri2653 · Cited by 3,952
Membrane transporters in drug development
The International Transporter Consortium, Giacomini, K. M., Huang, S.-M., Tweedie, D. J., Benet, L. Z., Brouwer, K. L. R., Chu, X., Dahlin, A., Evers, R., Fischer, V., et al. (2010) · Nature Reviews Drug Discovery · doi:10.1038/nrd3028 · Cited by 3,340
Occludin: a novel integral membrane protein localizing at tight junctions.
Furuse, M., Hirase, T., Itoh, M., Nagafuchi, A., Yonemura, S., Tsukita, S., & Tsukita, S. (1993) · The Journal of cell biology · doi:10.1083/jcb.123.6.1777 · Cited by 2,580
Hidalgo, I. J., Raub, T. J., & Borchardt, R. T. (1989) · Gastroenterology · doi:10.1016/s0016-5085(89)80072-1 · Cited by 2,396
Concordance of the toxicity of pharmaceuticals in humans and in animals
Olson, H., Betton, G., Robinson, D., Thomas, K., Monro, A., Kolaja, G., Lilly, P., Sanders, J., Sipes, G., Bracken, W., et al. (2000) · Regulatory Toxicology and Pharmacology · doi:10.1006/rtph.2000.1399 · Cited by 2,050
Determination of drug permeability and prediction of drug absorption in Caco-2 monolayers
Hubatsch, I., Ragnarsson, E. G. E., & Artursson, P. (2007) · Nature Protocols · doi:10.1038/nprot.2007.303 · Cited by 1,499
Yee, S. (1997) · Pharmaceutical Research · doi:10.1023/a:1012102522787 · Cited by 1,030
Research works printed but not linked: 3
- Ho, 1993, Cancer Res., 53, 641
- Dai, 2012, Int. J. Mol. Med, 29, 202
- Coconnier, 1993, FEMS Microbiol. Lett., 110, 299, 10.1111/j.1574-6968.1993.tb06339.x · doi:10.1111/j.1574-6968.1993.tb06339.x · Paper page
Cited by
Items 401–500 of 1,004
Hydrogel‐based three‐dimensional cell culture for organ‐on‐a‐chip applications
Lee, S. H., Shim, K. Y., Kim, B., & Sung, J. H. (2017) · Biotechnology Progress · doi:10.1002/btpr.2457 · Cited by 63
Ertürk-Hasdemir, D., & Kasper, D. L. (2018) · Annals of the New York Academy of Sciences · doi:10.1111/nyas.13660 · Cited by 74
3D Immunocompetent Organ‐on‐a‐Chip Models
Maharjan, S., Cecen, B., & Zhang, Y. S. (2020) · Small Methods · doi:10.1002/smtd.202000235 · Cited by 62
Physically Active Bioreactors for Tissue Engineering Applications
Castro, N., Ribeiro, S., Fernandes, M. M., Ribeiro, C., Cardoso, V. F., Correia, V. M. G., Mínguez, R., & Lanceros-Méndez, S. (2020) · Advanced Biosystems · doi:10.1002/adbi.202000125 · Cited by 69
Biosynthetic, biomimetic, and self-assembled vascularized Organ-on-a-Chip systems
Fritschen, A., & Blaeser, A. (2020) · Biomaterials · doi:10.1016/j.biomaterials.2020.120556 · Cited by 65
Li, X.-G., Chen, M.-X., Zhao, S.-Q., & Wang, X.-Q. (2022) · Stem Cell Reviews and Reports · doi:10.1007/s12015-021-10205-y · Cited by 60
Microfluidic devices for construction of contractile skeletal muscle microtissues
Shimizu, K., Araki, H., Sakata, K., Tonomura, W., Hashida, M., & Konishi, S. (2014) · Journal of Bioscience and Bioengineering · doi:10.1016/j.jbiosc.2014.07.003 · Cited by 63
In vitro generation of colonic epithelium from primary cells guided by microstructures
Wang, Y., Ahmad, A. A., Sims, C. E., Magness, S. T., & Allbritton, N. L. (2014) · Lab on a Chip · doi:10.1039/c3lc51353j · Cited by 66
Soucy, J. R., Bindas, A. J., Koppes, A. N., & Koppes, R. A. (2019) · iScience · doi:10.1016/j.isci.2019.10.052 · Cited by 62
“These engineered cell culture models are frequently termed ‘‘organs-on-chips’’ or ‘‘microphysiological systems’’ (MPS) and are geared toward supplementing drug discovery by predicting in vivo efficacy and toxicity (Huh et al., 2012) more accurately compared with static 2D cell cultures.”
In Vitro and In Vivo Models for Evaluating the Oral Toxicity of Nanomedicines
Lama, S., Merlin-Zhang, O., & Yang, C. (2020) · Nanomaterials · doi:10.3390/nano10112177 · Cited by 67
An, A. Y., Choi, K.-Y. G., Baghela, A. S., & Hancock, R. E. W. (2021) · Frontiers in Microbiology · doi:10.3389/fmicb.2021.640787 · Cited by 70
“Combining these two technologies results in the organoid-on-a-chip model, which is a microfluidics platform where bacteria and/or host cells grow in chambers perfused by microchannels (Kim et al., 2012).”
Advancing gut microbiome research using cultivation
Sommer, M. O. A. (2015) · Current Opinion in Microbiology · doi:10.1016/j.mib.2015.08.004 · Cited by 71
“Furthermore, as improved microfabrication techniques enable simulations of actual gut environments, it may be possible to identify more physiologically relevant interactions [37].”
Castan, L., Bøgh, K. L., Maryniak, N. Z., Epstein, M. M., Kazemi, S., O’Mahony, L., Bodinier, M., Smit, J. J., van Bilsen, J. H. M., Blanchard, C., et al. (2019) · Allergy · doi:10.1111/all.13943 · Cited by 59
Biofabrication Strategies and Engineered In Vitro Systems for Vascular Mechanobiology
Pradhan, S., Banda, O. A., Farino, C. J., Sperduto, J. L., Keller, K. A., Taitano, R. A., & Slater, J. H. (2020) · Advanced Healthcare Materials · doi:10.1002/adhm.201901255 · Cited by 64
Recent Advances in Microfluidic Platforms for Programming Cell‐Based Living Materials
Zhang, P., Shao, N., & Qin, L. (2021) · Advanced Materials · doi:10.1002/adma.202005944 · Cited by 63
Exploring Drug Metabolism by the Gut Microbiota: Modes of Metabolism and Experimental Approaches
Dhurjad, P., Dhavaliker, C., Gupta, K., & Sonti, R. (2021) · Drug Metabolism and Disposition · doi:10.1124/dmd.121.000669 · Cited by 66
“…T Journals on July 25, 2022 dm d.aspetjournals.org D ow nloaded from 23 studies, the microenvironment of the cells is recreated by control of culture medium flow rate through the microchannels and, in other studies, by applying cyclic strain to cause peristalsis like deformations(Kim et al., 2012).”
Cell-stretching devices: advances and challenges in biomedical research and live-cell imaging
Constantinou, I., & Bastounis, E. E. (2023) · Trends in biotechnology · doi:10.1016/j.tibtech.2022.12.009 · Cited by 63
Standardizing designed and emergent quantitative features in microphysiological systems
Nahon, D. M., Moerkens, R., Aydoğmuş, H., Lendemeijer, B., Martínez-Silgado, A., Stein, J. M., Dostanić, M., Frimat, J., Gontan, C., de Graaf, M. N. S., et al. (2024) · Nature Biomedical Engineering · doi:10.1038/s41551-024-01236-0 · Cited by 71
“This approach can generate physiologically relevant deformations of 0–30% at a frequency of 0.15 Hz 24 (Table 1).”
InfluentialUse of brush border membrane vesicles to simulate the human intestinal digestion
Picariello, G., Ferranti, P., & Addeo, F. (2015) · Food Research International · doi:10.1016/j.foodres.2015.11.002 · Cited by 70
Microfluidic platforms for modeling biological barriers in the circulatory system
Yu, F., Kumar, N. D. O. S., Choudhury, D., Foo, L. C., & Ng, S. H. (2018) · Drug Discovery Today · doi:10.1016/j.drudis.2018.01.036 · Cited by 61
Biomimetic human lung-on-a-chip for modeling disease investigation
Li, K., Yang, X., Xue, C., Zhao, L., Zhang, Y., & Gao, X. (2019) · Biomicrofluidics · doi:10.1063/1.5100070 · Cited by 65
Recent advances and future applications of microfluidic live-cell microarrays
Rothbauer, M., Wartmann, D., Charwat, V., & Ertl, P. (2015) · Biotechnology Advances · doi:10.1016/j.biotechadv.2015.06.006 · Cited by 68
Organs on microfluidic chips: A mini review
Jiang, B., Zheng, W., Zhang, W., & Jiang, X. (2013) · Science China Chemistry · doi:10.1007/s11426-013-4971-0 · Cited by 62
Drug Disposition in the Lower Gastrointestinal Tract: Targeting and Monitoring
Lemmens, G., Camp, A. V., Kourula, S., Vanuytsel, T., & Augustijns, P. (2021) · Pharmaceutics · doi:10.3390/pharmaceutics13020161 · Cited by 74
Time to integrate biotechnological approaches into fish gut microbiome research
Luna, G. M., Quero, G. M., Kokou, F., & Kormas, K. A. (2021) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2021.07.018 · Cited by 68
In vitro models to study human gut-microbiota interactions: Applications, advances, and limitations
Qi, Y., Yu, L., Tian, F., Zhao, J., & Zhai, Q. (2023) · Microbiological Research · doi:10.1016/j.micres.2023.127336 · Cited by 72
Safety and fate of nanomaterials in food: The role of in vitro tests
Xavier, M., Parente, I. A., Rodrigues, P. M., Cerqueira, M. Â., Pastrana, L. M., & Gonçalves, C. (2021) · Trends in Food Science & Technology · doi:10.1016/j.tifs.2021.01.050 · Cited by 61
Cell-based microfluidic platform for mimicking human olfactory system
Lee, S. H., Oh, E. H., & Park, T. H. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.06.072 · Cited by 58
Advances in cell-based permeability assays to screen drugs for intestinal absorption
Volpe, D. A. (2020) · Expert Opinion on Drug Discovery · doi:10.1080/17460441.2020.1735347 · Cited by 58
Giusti, S., Sbrana, T., Marca, M. L., Patria, V. D., Martinucci, V., Tirella, A., Domenici, C., & Ahluwalia, A. D. (2014) · Biotechnology Journal · doi:10.1002/biot.201400004 · Cited by 70
Rivera, K. R., Yokus, M. A., Erb, P. D., Pozdin, V. A., & Daniele, M. (2019) · The Analyst · doi:10.1039/c8an02201a · Cited by 57
Basement membrane properties and their recapitulation in organ-on-chip applications
Salimbeigi, G., Vrana, N. E., Ghaemmaghami, A. M., Huri, P. Y., & McGuinness, G. B. (2022) · Materials Today Bio · doi:10.1016/j.mtbio.2022.100301 · Cited by 57
“Microfabrication employs techniques to fabricate micrometre-scale structures and is the commonly used approach to fabricate the microstructured membranes for OOCs [30,148,149].”
Cassotta, M., Forbes-Hernández, T. Y., Iglesias, R. C., Ruíz, R., Elexpuru-Zabaleta, M., Giampieri, F., & Battino, M. A. (2020) · Nutrients · doi:10.3390/nu12061827 · Cited by 62
“Notably, it has been shown that the probiotic Lactobacillus rhamnosus GG improved intestinal barrier function when co-cultured in the lumen of the intestinal epithelial channel of the hGoC [206], and that the VSL#3® probiotic formulation suppressed villus blunting and the loss of barrier function induced by infection…”
Yang, S., Chen, Z., Cheng, Y., Liu, T., Yin, L., Pu, Y., & Liang, G. (2020) · Environmental Pollution · doi:10.1016/j.envpol.2020.115861 · Cited by 61
Kimura, H., Nishikawa, M., Kutsuzawa, N., Tokito, F., Kobayashi, T., Kurniawan, D. A., Shioda, H., Cao, W., Shinha, K., Nakamura, H., et al. (2024) · Drug Metabolism and Pharmacokinetics · doi:10.1016/j.dmpk.2024.101046 · Cited by 67
Bioreactor engineering of stem cell environments
Tandon, N. M., Marolt, D., Cimetta, E., & Vunjak‐Novakovic, G. (2013) · Biotechnology Advances · doi:10.1016/j.biotechadv.2013.03.007 · Cited by 66
“Even a human gut-on-chip device with intestinal flora and cyclic strain that mimics peristalsis has been developed (Kim et al. 2012).”
A microscale anisotropic biaxial cell stretching device for applications in mechanobiology
Tremblay, D., Chagnon‐Lessard, S., Mirzaei, M., Pelling, A. E., & Godin, M. (2013) · Biotechnology Letters · doi:10.1007/s10529-013-1381-5 · Cited by 56
“The recent development of microscale stretching devices has provided numerous insights into the kinetics of cellular responses to mechanical strain, at various time scales (milliseconds to hours) (Huh et al. 2010; Huang and Nguyen 2013; Kim et al. 2012; Moraes et al. 2010; Jungbauer et al. 2008; Moraes et al. 2013; Wa…”
Lachaux, J., Alcaine, C., Gómez-Escoda, B., Perrault, C. M., Duplan, D. O., Wu, P.-Y. J., Ochoa, I., Fernandez, L., Mercier, O., Coudreuse, D., et al. (2017) · Lab on a Chip · doi:10.1039/c7lc00488e · Cited by 57
Onfroy-Roy, L., Hamel, D., Foncy, J., Malaquin, L., & Ferrand, A. (2020) · Cells · doi:10.3390/cells9122629 · Cited by 66
Sano, E., Mori, C., Matsuoka, N., Ozaki, Y., Yagi, K., Wada, A., Tashima, K., Yamasaki, S., Tanabe, K., Yano, K., et al. (2019) · Micromachines · doi:10.3390/mi10110793 · Cited by 57
“, in lung [15–17], gut [18,19], kidney [20–22], and cancer models [23].”
Driver, R., & Mishra, S. (2022) · BioChip Journal · doi:10.1007/s13206-022-00087-8 · Cited by 69
“Kim [66] developed a biomimetic “human-gut-on-chip” which not only mimics the structural, functional and pathophysiological functions of the human gut but also account for crucial microbial symbionts that are found in-vivo.”
Intestinal protein uptake and IgE-mediated food allergy
Ballegaard, A. R., & Bøgh, K. L. (2022) · Food Research International · doi:10.1016/j.foodres.2022.112150 · Cited by 67
“Furthermore, the gut-on-a-chip technique enables features such as luminal flow and peristalsis-like movement (Kim, Huh, Hamilton, & Ingber, 2012).”
Elzinga, F. A., Khalili, B., Touw, D. J., Prins, J. R., Olinga, P., Leuvenink, H. G. D., van Goor, H., Gordijn, S. J., Nagelkerke, A., & Mian, P. (2023) · Journal of Clinical Medicine · doi:10.3390/jcm12134315 · Cited by 60
Modelling host–microbiome interactions in organ-on-a-chip platforms
Shin, Y. C., Than, N., Min, S., Shin, W., & Kim, H. J. (2023) · Nature Reviews Bioengineering · doi:10.1038/s44222-023-00130-9 · Cited by 65
“…cytodifferentiation 60 , trigger cellular elongation (for example, induce columnar morphology of Caco-2 cells in a gut-on-a-chip platform 46,61 ), and promote morphogenesis (for example, villi-like 3D growth of intestinal epithelial cells in a gut-on-a-chip platform 55,60,62,63 ) by…”
InfluentialSelf-citationAlghannam, F. S., Alayed, M., Alfihed, S., Sakr, M. A., Almutairi, D., Alshamrani, N., & Fayez, N. A. (2025) · Biosensors · doi:10.3390/bios15020076 · Cited by 71
Microfluidic-Based Multi-Organ Platforms for Drug Discovery
Rezaei Kolahchi, A., Khadem Mohtaram, N., Pezeshgi Modarres, H., Mohammadi, M., Geraili, A., Jafari, P., Akbari, M., & Sanati-Nezhad, A. (2016) · Micromachines · doi:10.3390/mi7090162 · Cited by 53
“The transcellular mechanisms of transport, the degree of protein secretions, and the ion absorptions for various cell types in addition to the tissue barrier performance such as the blood-brain barrier (BBB) or epithelial barriers are explored in such devices [78,80,98–101] (Figure 3c).”
InfluentialSticker, D., Rothbauer, M., Ehgartner, J., Steininger, C., Liske, O., Liska, R., Neuhaus, W., Mayr, T., Haraldsson, T., Kutter, J. P., et al. (2019) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.8b19641 · Cited by 61
Ceppa, F., Izzo, L., Sardelli, L., Raimondi, I., Tunesi, M., Albani, D., & Giordano, C. (2020) · Frontiers in Cellular and Infection Microbiology · doi:10.3389/fcimb.2020.00297 · Cited by 60
“This model allows stable long-term (∼2 weeks) co-culture of IECs and commensal microbes of the gut microbiota (Kim et al., 2012; von Martels et al., 2017).”
InfluentialPasman, T., Baptista, D., van Riet, S., Truckenmüller, R. K., Hiemstra, P. S., Rottier, R. J., Stamatialis, D. F., & Poot, A. A. (2020) · Membranes · doi:10.3390/membranes10110330 · Cited by 56
Bioengineering approaches to simulate human colon microbiome ecosystem
Roupar, D., Berni, P. R. D. A., Martins, J. T., Caetano, A. C., Teixeira, J. A., & Nobre, C. (2021) · Trends in Food Science & Technology · doi:10.1016/j.tifs.2021.04.035 · Cited by 63
Modeling the Glomerular Filtration Barrier and Intercellular Crosstalk
Ebefors, K., Lassén, E., Anandakrishnan, N., Azeloglu, E. U., & Daehn, I. S. (2021) · Frontiers in Physiology · doi:10.3389/fphys.2021.689083 · Cited by 78
“Organs-on-a-chip have been developed for complex organs such as liver (Beckwitt et al., 2018), heart (Agarwal et al., 2013), gut (Kim et al., 2012; Kim and Ingber, 2013), lungs (Huh et al., 2010, 2012), and brain (Moreno et al., 2015).”
Youhanna, S. C., Kemas, A. M., Preiss, L. C., Zhou, Y., Shen, J. X., Cakal, S. D., Paqualini, F. S., Goparaju, S. K., Shafagh, R. Z., Lind, J. U., et al. (2022) · Pharmacological Reviews · doi:10.1124/pharmrev.120.000238 · Cited by 67
Liver-on-a-chip devices: the pros and cons of complexity
Dalsbecker, P., Adiels, C. B., & Goksör, M. (2022) · American Journal of Physiology-Gastrointestinal and Liver Physiology · doi:10.1152/ajpgi.00346.2021 · Cited by 64
Luo, H., Li, M., Wang, F., Yang, Y., Wang, Q. L., Zhao, Y., Du, F., Chen, Y., Shen, J., Zhao, Q., et al. (2022) · International Journal of Biological Sciences · doi:10.7150/ijbs.72600 · Cited by 60
Emerging trends in the methodology of environmental toxicology: 3D cell culture and its applications
Wang, H., Xu, T., & Yin, D. (2022) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2022.159501 · Cited by 61
Engineered Biomimetic Membranes for Organ-on-a-Chip
Rahimnejad, M., Rasouli, F., Jahangiri, S., Ahmadi, S., Rabiee, N., Farani, M. R., Akhavan, O., Asadnia, M., Fatahi, Y., Hong, S., et al. (2022) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.2c00531 · Cited by 59
Large-scale fabrication of free-standing and sub-μm PDMS through-hole membranes
The, H. L., Tibbe, M. P., Loessberg-Zahl, J., do Carmo, M. P., van der Helm, M. W., Bomer, J. G., van den Berg, A., Leferink, A., Segerink, L. I., & Eijkel, J. C. T. (2018) · Nanoscale · doi:10.1039/c7nr09658e · Cited by 63
Esser, F., Masselter, T., & Speck, T. (2019) · Advanced Intelligent Systems · doi:10.1002/aisy.201900009 · Cited by 55
Rapid Prototyping of Multilayer Microphysiological Systems
Hosic, S., Bindas, A. J., Puzan, M. L., Lake, W., Soucy, J. R., Zhou, F., Koppes, R. A., Breault, D. T., Murthy, S. K., & Koppes, A. N. (2020) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.0c00190 · Cited by 56
A Bioprinted Tubular Intestine Model Using a Colon‐Specific Extracellular Matrix Bioink
Han, H., Park, Y., Choi, Y., Yong, U., Kang, B., Shin, W., Min, S., Kim, H. J., & Jang, J. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202101768 · Cited by 57
Self-citationGut-on-chip for ecological and causal human gut microbiome research
Moossavi, S., Arrieta, M., Sanati‐Nezhad, A., & Bishehsari, F. (2022) · Trends in Microbiology · doi:10.1016/j.tim.2022.01.014 · Cited by 55
Boquet-Pujadas, A., Feaugas, T., Petracchini, A., Grassart, A., Mary, H., Manich, M., Gobaa, S., Olivo‐Marín, J., Sauvonnet, N., & Labruyère, E. (2022) · Science Advances · doi:10.1126/sciadv.abo5767 · Cited by 59
“For instance, it has been shown that the topology and peristaltic cycle simulated by guts-on-chip (16) are essential to reproduce the virulent outcome of Shigella flexneri infections (17) reported in clinical studies (18), which could not otherwise be observed in the face of simpler epithelial monolayers of colon cell…”
Johnston, H. J., Verdon, R., Gillies, S., Brown, D. M., Fernandes, T. F., Henry, T. B., Rossi, A. G., Tran, L., Tucker, C. S., Tyler, C. R., et al. (2017) · Critical Reviews in Toxicology · doi:10.1080/10408444.2017.1404965 · Cited by 62
“immune and nonimmune cells) in static or fluidic conditions, for various target sites such as the lung, and gut (e.g. Lehmann et al. 2011; Kim et al. 2012; Susewind et al. 2016), can be used to better mimic in vivo situations when evaluating NM toxicity, and in order to investigate responses which require communicatio…”
Winkler, T. E., Feil, M., Stronkman, E. F. G. J., Matthiesen, I., & Herland, A. (2020) · Lab on a Chip · doi:10.1039/d0lc00009d · Cited by 59
Mohebali, N., Ekat, K., Kreikemeyer, B., & Breitrück, A. (2020) · Nutrients · doi:10.3390/nu12082251 · Cited by 58
“The host interaction with gut microbiota has been assessed through different in vitro models such as the exposure of intestinal epithelial cells to bacteria-free supernatants [41] or the direct co-culture-like Transwell system [42] microcarrier beads [43], human oxygen bacteria anaerobic (HoxBan) system [44], human gu…”
Inkjet Printing of Complex Soft Machines with Densely Integrated Electrostatic Actuators
Schlatter, S., Grasso, G., Rosset, S., & Shea, H. R. (2020) · Advanced Intelligent Systems · doi:10.1002/aisy.202000136 · Cited by 59
Lindner, M., Laporte, A., Block, S., Elomaa, L., & Weinhart, M. (2021) · Cells · doi:10.3390/cells10082062 · Cited by 63
In vitro and ex vivo models for evaluating vaginal drug delivery systems
Shapiro, R. L., DeLong, K., Zulfiqar, F., Carter, D. M., Better, M., & Ensign, L. M. (2022) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2022.114543 · Cited by 60
Gut-on-a-chip for disease models
Xian, C., Zhang, J., Zhao, S., & Li, X. (2023) · Journal of Tissue Engineering · doi:10.1177/20417314221149882 · Cited by 57
Gut-on-a-Chip Models: Current and Future Perspectives for Host–Microbial Interactions Research
Morelli, M., Kurek, D., Ng, C. P., & Queiroz, K. C. S. (2023) · Biomedicines · doi:10.3390/biomedicines11020619 · Cited by 68
“When comparing Caco-2 cells cultured in static or dynamic conditions, fluidic culture accelerated the formation of leak-tight gut tubules [23], improved morphogenesis [20,25,35], and enhanced barrier integrity [20,21,23,36].”
InfluentialOrgan-On-A-Chip: An Emerging Research Platform
Nithin, R., Aggarwal, A., Sravani, A. B., Mallya, P., & Lewis, S. A. (2023) · Organogenesis · doi:10.1080/15476278.2023.2278236 · Cited by 69
“28 An elastic collagen fiber membrane enclosed within a microfluidic device for testing was fabricated.”
Advancing Organoid Engineering for Tissue Regeneration and Biofunctional Reconstruction
Jin, H., Xue, Z., Liu, J., Ma, B., Yang, J., & Lei, L. (2024) · Biomaterials Research · doi:10.34133/bmr.0016 · Cited by 60
Microfluidic isolation of highly pure embryonic stem cells using feeder-separated co-culture system
Chen, Q., Wu, J., Zhuang, Q., Lin, X., Zhang, J., & Lin, J. (2013) · Scientific Reports · doi:10.1038/srep02433 · Cited by 55
Dawson, A., Dyer, C., Macfie, J., Davies, J., Karsai, L., Greenman, J., & Jacobsen, M. (2016) · Biomicrofluidics · doi:10.1063/1.4964813 · Cited by 53
Multifunctional Bioreactor System for Human Intestine Tissues
Zhou, W., Chen, Y. G., Roh, T. T., Lin, Y., Ling, S., Zhao, S., Lin, J., Khalil, N., Cairns, D. M., Manousiouthakis, E., et al. (2017) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.7b00794 · Cited by 55
Multi-organ-on-a-chip for pharmacokinetics and toxicokinetic study of drugs
Sung, J. H. (2021) · Expert Opinion on Drug Metabolism & Toxicology · doi:10.1080/17425255.2021.1908996 · Cited by 58
Intratumoral bacteria are an important “accomplice” in tumor development and metastasis
Wang, G., He, X., & Wang, Q. (2022) · Biochimica et Biophysica Acta (BBA) - Reviews on Cancer · doi:10.1016/j.bbcan.2022.188846 · Cited by 52
Microfluidics for Biofilm Studies
Yuan, L., Straub, H., Shishaeva, L., & Ren, Q. (2023) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-091522-103827 · Cited by 60
Engineered live bacteria as disease detection and diagnosis tools
Tanniche, I., & Behkam, B. (2023) · Journal of Biological Engineering · doi:10.1186/s13036-023-00379-z · Cited by 65
Material strategies for creating artificial cell-instructive niches
Edalat, F., Sheu, I., Manoucheri, S., & Khademhosseini, A. (2012) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2012.05.007 · Cited by 52
“However, the ability for microfluidics to generate mechanical, chemical, and geometric constraints similar to those found in physiological conditions are unparalleled by current methods, thus rendering it valuable to the field of tissue engineering as demonstrated by microfabricated models of brain, blood vessels, ske…”
Microfluidic Devices and Their Applications
Aryasomayajula, A., Bayat, P., Rezai, P., & Selvaganapathy, P. R. (2017) · Springer handbooks · doi:10.1007/978-3-662-54357-3_16 · Cited by 60
Cacopardo, L., Costa, J. S., Giusti, S., Buoncompagni, L., Meucci, S., Corti, A., Mattei, G., & Ahluwalia, A. D. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2019.111340 · Cited by 60
“A multilayer microfluidic device was fabricated by Booth and colleagues using four PDMS substrates, two glass layers, a porous polycarbonate membrane and four AgCl thin-film electrodes, which were then connected to the EVOM (Booth and Kim, 2012).”
InfluentialBone-chip system to monitor osteogenic differentiation using optical imaging
Sheyn, D., Yakubovich, D. C., Ben‐David, S., Mel, S. D., Chan, V., Hinojosa, C. D., Wen, N., Hamilton, G. A., Gazit, D., & Gazit, Z. (2019) · Microfluidics and Nanofluidics · doi:10.1007/s10404-019-2261-7 · Cited by 60
Self-citationImpact of dietary fibers in infant formulas on gut microbiota and the intestinal immune barrier
Kong, C., Faas, M. M., de Vos, P., & Akkerman, R. (2020) · Food & Function · doi:10.1039/d0fo01700k · Cited by 54
Intestine-on-a-chip: Next level in vitro research model of the human intestine
Donkers, J. M., Amirabadi, H. E., & van de Steeg, E. (2020) · Current Opinion in Toxicology · doi:10.1016/j.cotox.2020.11.002 · Cited by 57
Synthetic gut microbiome: Advances and challenges
Mabwi, H. A., Kim, E., Song, D., Yoon, H. S., Pan, C., Komba, E. V. G., Ko, G., & Cha, K. H. (2020) · Computational and Structural Biotechnology Journal · doi:10.1016/j.csbj.2020.12.029 · Cited by 59
Microfluidic approaches in microbial ecology
Ugolini, G. S., Wang, M., Secchi, E., Pioli, R., Ackermann, M., & Stocker, R. (2024) · Lab on a Chip · doi:10.1039/d3lc00784g · Cited by 57
Microfluidic Gel Patterning Method by Use of a Temporary Membrane for Organ‐On‐Chip Applications
Tibbe, M. P., Leferink, A., van den Berg, A., Eijkel, J. C. T., & Segerink, L. I. (2018) · Advanced Materials Technologies · doi:10.1002/admt.201700200 · Cited by 54
Kulthong, K., Duivenvoorde, L. P. M., Mizera, B. Z., Rijkers, D., ten Dam, G., Oegema, G., Puzyn, T., Bouwmeester, H., & van der Zande, M. (2018) · RSC Advances · doi:10.1039/c8ra05430d · Cited by 53
Song, Y., Uchida, H., Sharipol, A., Piraino, L. R., Mereness, J. A., Ingalls, M. H., Rebhahn, J. A., Newlands, S. D., DeLouise, L. A., Ovitt, C. E., et al. (2021) · Communications Biology · doi:10.1038/s42003-021-01876-x · Cited by 55
Advances in Micro/Nanoporous Membranes for Biomedical Engineering
Sun, M., Han, K., Hu, R., Liu, D., Fu, W., & Liu, W. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202001545 · Cited by 50
Bacteriophages evolve enhanced persistence to a mucosal surface
Chin, W. H., Kett, C., Cooper, O., Müseler, D., Zhang, Y., Bamert, R. S., Patwa, R. R., Woods, L. C., Devendran, C., Korneev, D., et al. (2022) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2116197119 · Cited by 59
Integrated biosensors for monitoring microphysiological systems
Mou, L., Mandal, K., Mecwan, M. M., Hernández, A. L., Maity, S., Sharma, S., Herculano, R. D., Kawakita, S., Jucaud, V., Dokmeci, M. R., et al. (2022) · Lab on a Chip · doi:10.1039/d2lc00262k · Cited by 57
Clamping strategies for organ-on-a-chip devices
Carvalho, D. J., Moroni, L., & Giselbrecht, S. (2023) · Nature Reviews Materials · doi:10.1038/s41578-022-00523-z · Cited by 53
Fluid flow to mimic organ function in 3D in vitro models
Juste-Lanas, Y., Hervás-Raluy, S., García‐Aznar, J. M., & González‐Loyola, A. (2023) · APL Bioengineering · doi:10.1063/5.0146000 · Cited by 57
Cytostretch, an Organ-on-Chip Platform
Gaio, N., Van Meer, B., Quirós Solano, W., Bergers, L., Van de Stolpe, A., Mummery, C., Sarro, P., & Dekker, R. (2016) · Micromachines · doi:10.3390/mi7070120 · Cited by 50
“There are thus well-described OOCs for liver [7], kidney [8], lung [9], and gut [10], among multiple other organs [2].”
The Contributions of Human Mini-Intestines to the Study of Intestinal Physiology and Pathophysiology
Yu, H. M., Hasan, N. M., In, J. G., Estes, M. K., Kovbasnjuk, O. N., Zachos, N. C., & Donowitz, M. (2017) · Annual Review of Physiology · doi:10.1146/annurev-physiol-021115-105211 · Cited by 55
Shear stress induces noncanonical autophagy in intestinal epithelial monolayers
Kim, S. W., Ehrman, J. D., Ahn, M., Kondo, J., Lopez, A. A., Oh, Y. S., Kim, X. H., Crawley, S. W., Goldenring, J. R., Tyska, M. J., et al. (2017) · Molecular Biology of the Cell · doi:10.1091/mbc.e17-01-0021 · Cited by 54
Pridgeon, C. S., Schlott, C., Wong, M. W., Heringa, M. B., Heckel, T., Leedale, J., Launay, L., Gryshkova, V., Przyborski, S. A., Bearon, R. N., et al. (2018) · Archives of Toxicology · doi:10.1007/s00204-018-2152-9 · Cited by 55
Emerging Role of Organ‐on‐a‐Chip Technologies in Quantitative Clinical Pharmacology Evaluation
Isoherranen, N., Madabushi, R., & Huang, S. (2019) · Clinical and Translational Science · doi:10.1111/cts.12627 · Cited by 50
“An interesting aspect of some of the human gut microphysiological systems is that they allow coculture of human gut microbiome with the epithelial cells.(50) Although no applications of this coculture system to drug metabolism and absorption have yet been published, one can envision that, in the future, this system wi…”
Metadata
- Authors
- Kim, H. J., Huh, D., Hamilton, G., & Ingber, D. E.
- Affiliations
- Harvard University (US)
- Boston Children's Hospital (US)
- Corresponding author
- Ingber, Donald E.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2012
- Volume
- 12
- Issue
- 12
- Pages
- 2165
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2168752825
- Cited by
- 1,734
- References
- 65
- Citations by year
- 2026: 114 · 2025: 130 · 2024: 163 · 2023: 150 · 2022: 150 · 2021: 185 · 2020: 154 · 2019: 154 · 2018: 133 · 2017: 130 · 2016: 84 · 2015: 61 · 2014: 54 · 2013: 57 · 2012: 13
- FWCI
- 33.74
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Lab on a Chip (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Harvard University
- Hansjörg Wyss Institute for Biologically Inspired Engineering, Harvard University
- National Institute of Environmental Health Sciences (R01ES016665, ES016665-01A1)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Health Sciences › Medicine › Surgery › Tissue Engineering and Regenerative Medicine
- Keywords
- gut-on-a-chip, intestinal epithelium, Caco-2 cells, peristalsis, cyclic strain, microfluidics, extracellular matrix, Lactobacillus rhamnosus GG, intestinal barrier function, epithelial polarization, low shear stress, drug testing, alternatives to animal testing
- MeSH terms
- Aminopeptidases, beta-Galactosidase, Dimethylpolysiloxanes, Epithelial Cells, Humans, Intestines, Models, Biological, Caco-2 Cells, Tissue Engineering, Biomimetic Materials, Lacticaseibacillus rhamnosus, Metagenome
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.