Human gut-on-a-chip inhabited by microbial flora that experiences intestinal peristalsis-like motions and flow
The DOI matches its Crossref record; 65 of the 65 references it cites were found in a registry or an index.
Abstract
Development of an in vitro living cell-based model of the intestine that mimics the mechanical, structural, absorptive, transport and pathophysiological properties of the human gut along with its crucial microbial symbionts could accelerate pharmaceutical development, and potentially replace animal testing. Here, we describe a biomimetic 'human gut-on-a-chip' microdevice composed of two microfluidic channels separated by a porous flexible membrane coated with extracellular matrix (ECM) and lined by human intestinal epithelial (Caco-2) cells that mimics the complex structure and physiology of living intestine. The gut microenvironment is recreated by flowing fluid at a low rate (30 μL h(-1)) producing low shear stress (0.02 dyne cm(-2)) over the microchannels, and by exerting cyclic strain (10%; 0.15 Hz) that mimics physiological peristaltic motions. Under these conditions, a columnar epithelium develops that polarizes rapidly, spontaneously grows into folds that recapitulate the structure of intestinal villi, and forms a high integrity barrier to small molecules that better mimics whole intestine than cells in cultured in static Transwell models. In addition, a normal intestinal microbe (Lactobacillus rhamnosus GG) can be successfully co-cultured for extended periods (>1 week) on the luminal surface of the cultured epithelium without compromising epithelial cell viability, and this actually improves barrier function as previously observed in humans. Thus, this gut-on-a-chip recapitulates multiple dynamic physical and functional features of human intestine that are critical for its function within a controlled microfluidic environment that is amenable for transport, absorption, and toxicity studies, and hence it should have great value for drug testing as well as development of novel intestinal disease models.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“this 2-dimensional (2D) culture format fails to recapitulate physiological 3-dimensional (3D) intestinal cell and tissue morphology or re-establish other key intestinal differentiated functions (eg, mucus production, villi formation, cytochrome P-450-based drug metabolism).”
From Microfluidic Organ-on-a-Chip Models of Human Intestine (2018) · cites this paper as [16]
In the citing paper
“These conventional static models also cannot support the coculture of commensal microbiome with human intestinal cells, which are critical for gut physiology,16 because the bacteria rapidly overgrow and contaminate the human cell cultures within a day.”
From Microfluidic Organ-on-a-Chip Models of Human Intestine (2018) · cites this paper as [16]
In the citing paper
“In fact, barrier function was shown to increase when the intestinal epithelium was cocultured with L rhamnosus GG.16”
From Microfluidic Organ-on-a-Chip Models of Human Intestine (2018) · cites this paper as [16]
In the citing paper
“Importantly, because the Gut Chip has continuous fluid flow, villi formation, and mucus production, it is also possible to coculture living commensal microbes (eg, Lactobacillus rhamnosus GG)16 or the VSL#3 clinical probiotic formulation containing 8 different microbial strains42) in direct contact with the intestinal epithelial cells within the lumen of the parenchymal channel for weeks in vitro”
From Microfluidic Organ-on-a-Chip Models of Human Intestine (2018) · cites this paper as [16]
In the citing paper
“Importantly, the probiotic L rhamnosus GG was shown to increase intestinal barrier function when cocultured in the lumen of the intestinal epithelial channel of the human Gut Chip,16”
From Microfluidic Organ-on-a-Chip Models of Human Intestine (2018) · cites this paper as [16]
5 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Turnbaugh, P. J., Ley, R. E., Hamady, M., Fraser-Liggett, C. M., Knight, R., & Gordon, J. I. (2007) · Nature · doi:10.1038/nature06244 · Cited by 6,091
The gut microbiota shapes intestinal immune responses during health and disease
Round, J. L., & Mazmanian, S. K. (2009) · Nature Reviews Immunology · doi:10.1038/nri2515 · Cited by 5,029
Reconstituting organ-level lung functions on a chip
Huh, D., Matthews, B. D., Mammoto, A., Montoya-Zavala, M., Hsin, H. Y., & Ingber, D. E. (2010) · Science · doi:10.1126/science.1188302 · Cited by 4,250
Self-citationIntestinal mucosal barrier function in health and disease
Turner, J. R. (2009) · Nature reviews. Immunology · doi:10.1038/nri2653 · Cited by 3,952
Membrane transporters in drug development
The International Transporter Consortium, Giacomini, K. M., Huang, S.-M., Tweedie, D. J., Benet, L. Z., Brouwer, K. L. R., Chu, X., Dahlin, A., Evers, R., Fischer, V., et al. (2010) · Nature Reviews Drug Discovery · doi:10.1038/nrd3028 · Cited by 3,340
Occludin: a novel integral membrane protein localizing at tight junctions.
Furuse, M., Hirase, T., Itoh, M., Nagafuchi, A., Yonemura, S., Tsukita, S., & Tsukita, S. (1993) · The Journal of cell biology · doi:10.1083/jcb.123.6.1777 · Cited by 2,580
Hidalgo, I. J., Raub, T. J., & Borchardt, R. T. (1989) · Gastroenterology · doi:10.1016/s0016-5085(89)80072-1 · Cited by 2,396
Concordance of the toxicity of pharmaceuticals in humans and in animals
Olson, H., Betton, G., Robinson, D., Thomas, K., Monro, A., Kolaja, G., Lilly, P., Sanders, J., Sipes, G., Bracken, W., et al. (2000) · Regulatory Toxicology and Pharmacology · doi:10.1006/rtph.2000.1399 · Cited by 2,050
Determination of drug permeability and prediction of drug absorption in Caco-2 monolayers
Hubatsch, I., Ragnarsson, E. G. E., & Artursson, P. (2007) · Nature Protocols · doi:10.1038/nprot.2007.303 · Cited by 1,499
Yee, S. (1997) · Pharmaceutical Research · doi:10.1023/a:1012102522787 · Cited by 1,030
Research works printed but not linked: 3
- Ho, 1993, Cancer Res., 53, 641
- Dai, 2012, Int. J. Mol. Med, 29, 202
- Coconnier, 1993, FEMS Microbiol. Lett., 110, 299, 10.1111/j.1574-6968.1993.tb06339.x · doi:10.1111/j.1574-6968.1993.tb06339.x · Paper page
Cited by
Items 301–400 of 1,004
Intestinal organ chips for disease modelling and personalized medicine
Özkan, A., LoGrande, N., Feitor, J. F., Goyal, G., & Ingber, D. E. (2024) · Nature Reviews Gastroenterology & Hepatology · doi:10.1038/s41575-024-00968-3 · Cited by 110
“Yet another organ chip design uses two-chamber culture wells separated by a porous membrane that are similar in design to transwell inserts except that they are modified to permit dynamic fluid flow to the apical or basal channel or both 88 (Fig.”
InfluentialSelf-citationCard, R. M., Cawthraw, S. A., Nuñéz-García, J., Ellis, R. J., Kay, G. L., Pallen, M. J., Woodward, M. J., & Anjum, M. F. (2017) · mBio · doi:10.1128/mbio.00777-17 · Cited by 88
“The development of in vitro gut models that enable the coculture of human and microbial cells shows promise, but to date, only cultures containing one or two bacterial species have been assessed (44, 45), and their capacity to maintain the complex microbiota of the gut remains unreported.”
Ong, L. J. Y., Ching, T., Chong, L. H., Arora, S., Li, H., Hashimoto, M., DasGupta, R., Yuen, P. K., & Toh, Y. (2019) · Lab on a Chip · doi:10.1039/c9lc00160c · Cited by 90
Recent progress in lab-on-a-chip for pharmaceutical analysis and pharmacological/toxicological test
Ai, Y., Zhang, F., Wang, C., Xie, R., & Liang, Q. (2019) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2019.06.026 · Cited by 91
Org, E., Mehrabian, M., & Lusis, A. J. (2015) · Atherosclerosis · doi:10.1016/j.atherosclerosis.2015.05.035 · Cited by 85
“Some novel approaches, such as a microfluidics-based Gut-on-a-Chip model have been proposed [117,120].”
Mimicking Epithelial Tissues in Three-Dimensional Cell Culture Models
Torras, N., García-Díaz, M., Fernández‐Majada, V., & Martínez, E. (2018) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2018.00197 · Cited by 99
Ballerini, M., Galié, S., Tyagi, P., Catozzi, C., Raji, H., Nabinejad, A., Macandog, A. D. G., Cordiale, A., Slivinschi, B. I., Kugiejko, K. K., et al. (2025) · Nature Biomedical Engineering · doi:10.1038/s41551-024-01318-z · Cited by 103
“Indeed, due to their inverted structural arrangement, the apical compartment is enclosed within the lumen and has an altered environment and limited access 25,29,30 .”
The revolution of PDMS microfluidics in cellular biology
Banik, S., Uchil, A., Kalsang, T., Chakrabarty, S., Ali, M. A., Srisungsitthisunti, P., Mahato, K. K., Surdo, S., & Mazumder, N. (2023) · Critical Reviews in Biotechnology · doi:10.1080/07388551.2022.2034733 · Cited by 84
Recent lab‐on‐chip developments for novel drug discovery
Khalid, N., Kobayashi, I., & Nakajima, M. (2017) · WIREs Systems Biology and Medicine · doi:10.1002/wsbm.1381 · Cited by 83
3D gut-liver chip with a PK model for prediction of first-pass metabolism
Lee, D. W., Ha, S. K., Choi, I., & Sung, J. H. (2017) · Biomedical Microdevices · doi:10.1007/s10544-017-0242-8 · Cited by 85
Barriers-on-chips: Measurement of barrier function of tissues in organs-on-chips
Arık, Y. B., van der Helm, M. W., Odijk, M., Segerink, L. I., Passier, R. C., van den Berg, A., & van der Meer, A. D. (2018) · Biomicrofluidics · doi:10.1063/1.5023041 · Cited by 97
A Biomimetic Human Gut‐on‐a‐Chip for Modeling Drug Metabolism in Intestine
Guo, Y., Li, Z., Su, W., Wang, L., Zhu, Y., & Qin, J. (2018) · Artificial Organs · doi:10.1111/aor.13163 · Cited by 88
Integrated cancer tissue engineering models for precision medicine
Bregenzer, M. E., Horst, E. N., Mehta, P., Novak, C. M., Raghavan, S., Snyder, C. S., & Mehta, G. (2019) · PLOS ONE · doi:10.1371/journal.pone.0216564 · Cited by 82
Microphysiological Systems to Recapitulate the Gut–Kidney Axis
Giordano, L., Mihaila, S. M., Amirabadi, H. E., & Masereeuw, R. (2021) · Trends in biotechnology · doi:10.1016/j.tibtech.2020.12.001 · Cited by 87
Organs-on-chips: research and commercial perspectives
Balijepalli, A., & Sivaramakrishan, V. (2016) · Drug Discovery Today · doi:10.1016/j.drudis.2016.11.009 · Cited by 89
Fang, Y., Guo, Y., Liu, T., Xu, R., Mao, S., Mo, X., Zhang, T., Ouyang, L., Xiong, Z., & Sun, W. (2022) · Chinese Journal of Mechanical Engineering Additive Manufacturing Frontiers · doi:10.1016/j.cjmeam.2022.100011 · Cited by 117
Bein, A., Fadel, C. W., Swenor, B., Cao, W., Powers, R. K., Camacho, D. M., Naziripour, A., Parsons, A., LoGrande, N., Sanjay, S. T., et al. (2022) · Nature Biomedical Engineering · doi:10.1038/s41551-022-00899-x · Cited by 83
Self-citationIntegration of Extracellular Matrices into Organ‐on‐Chip Systems
Kutluk, H., Bastounis, E. E., & Constantinou, I. (2023) · Advanced Healthcare Materials · doi:10.1002/adhm.202203256 · Cited by 84
Stem cell-derived intestinal organoids: a novel modality for IBD
Tian, C., Yang, M., Xu, H., Zhu, M., Yue, N.-N., Zhang, Y., Shi, R., Yao, J., Wang, L., Liang, Y.-J., et al. (2023) · Cell Death Discovery · doi:10.1038/s41420-023-01556-1 · Cited by 98
Engineering Functional Epithelium for Regenerative Medicine and In Vitro Organ Models: A Review
Vrana, N. E., Lavall�e, P., Dokmeci, M. R., Dehghani, F., Ghaemmaghami, A. M., & Khademhosseini, A. (2013) · Tissue Engineering Part B Reviews · doi:10.1089/ten.teb.2012.0603 · Cited by 81
“There are also efforts to incorporate other components of organs, such as microbial flora of intestine in organ-on-a-chip structures.(128) By having porous micropillar structures, it is possible to imitate the architecture of gastrointestinal epithelium and thus obtain a reliable microscale model of drug absorption.”
Chi, M., Yi, B., Oh, S., Park, D.-J., Sung, J. H., & Park, S. (2015) · Biomedical Microdevices · doi:10.1007/s10544-015-9966-5 · Cited by 88
Organoid Models for Infectious Disease
Blutt, S. E., & Estes, M. K. (2021) · Annual Review of Medicine · doi:10.1146/annurev-med-042320-023055 · Cited by 87
“In recognition of the important role the microbiota plays at epithelial surfaces, coculture systems that have both organoid and microbiota are being developed (92, 93).”
Vat photopolymerization 3D printed microfluidic devices for organ-on-a-chip applications
Milton, L. A., Viglione, M., Ong, L. J. Y., Nordin, G. P., & Toh, Y. (2023) · Lab on a Chip · doi:10.1039/d3lc00094j · Cited by 89
Organ-on-a-chip for assessing environmental toxicants
Cho, S., & Yoon, J. (2017) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2016.11.019 · Cited by 87
“Specifically, organ-specific fluid flow enables gradient formations of molecular components and maintenance of cell–cell interactions [39,40 ,41], which are vital to emulating”
Integration Concepts for Multi-Organ Chips: How to Maintain Flexibility?!
Rogal, J., Probst, C., & Loskill, P. (2017) · Future Science OA · doi:10.4155/fsoa-2016-0092 · Cited by 86
Human Microphysiological Models of Intestinal Tissue and Gut Microbiome
Steinway, S. N., Saleh, J., Koo, B., Delacour, D., & Kim, D. (2020) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2020.00725 · Cited by 84
“Application of pulsatile flow and mechanical deformation has allowed co-culture of microbes in direct contact with epithelial cells (instead of with a thin membrane) and for the ability to maintain systems for weeks, longer than any static cell culture systems (Kim et al., 2012; Huh et al., 2013).”
Nelson, M., Charbonneau, M. R., Coia, H. G., Castillo, M. J., Holt, C., Greenwood, E. S., Robinson, P. J., Merrill, E. A., Lubkowicz, D., & Mauzy, C. A. (2021) · Nature Communications · doi:10.1038/s41467-021-23072-5 · Cited by 84
Fois, C. A. M., Schindeler, A., Valtchev, P., & Dehghani, F. (2021) · Biomedical Microdevices · doi:10.1007/s10544-021-00591-y · Cited by 82
The Field Guide to 3D Printing in Optical Microscopy for Life Sciences
Rosario, M. D., Heil, H. S., Mendes, A., Saggiomo, V., & Henriques, R. (2021) · Advanced Biology · doi:10.1002/adbi.202100994 · Cited by 84
Kulthong, K., Duivenvoorde, L. P. M., Sun, H., Confederat, S., Wu, J., Spenkelink, B., de Haan, L., Marin, V., van der Zande, M., & Bouwmeester, H. (2020) · Toxicology in Vitro · doi:10.1016/j.tiv.2020.104815 · Cited by 86
“full maturation of the cell monolayer and barrier integrity was observed already after 3–5 days of seeding (Kim et al., 2012; Chi et al., 2015), which is faster than observed in our model.”
InfluentialOrgan-on-a-chip platforms for evaluation of environmental nanoparticle toxicity
Lu, R. X. Z., & Radisic, M. (2021) · Bioactive Materials · doi:10.1016/j.bioactmat.2021.01.021 · Cited by 94
Strelez, C., Chilakala, S., Ghaffarian, K., Lau, R., Spiller, E. R., Ung, N. M., Hixon, D., Yoon, A. Y., Sun, R., Lenz, H., et al. (2021) · iScience · doi:10.1016/j.isci.2021.102509 · Cited by 92
“The Intestine Chip emulates tissue function by displaying an intact intestinal barrier with the endothelial cells forming vessel-like structures along the bottom channel (Jalili-Firoozinezhad et al., 2018; Kim et al., 2012, 2016).”
InfluentialMicrofluidic Gut-on-a-Chip: Fundamentals and Challenges
Thomas, D. P., Zhang, J., Nguyen, N., & Ta, H. T. (2023) · Biosensors · doi:10.3390/bios13010136 · Cited by 95
“GOC model [32] PDMS 2 layered channels Pore size = 10 μm Caco-2 Lactobacillus rhamnosus GG(LGG) Yes Yes No”
InfluentialMicrofluidics for Porous Systems: Fabrication, Microscopy and Applications
Gerami, A., Alzahid, Y. A., Mostaghimi, P., Kashaninejad, N., Kazemifar, F., Amirian, T., Mosavat, N., Warkiani, M. E., & Armstrong, R. T. (2018) · Transport in Porous Media · doi:10.1007/s11242-018-1202-3 · Cited by 85
Watson, D. E., Hunziker, R., & Wikswo, J. P. (2017) · Experimental Biology and Medicine · doi:10.1177/1535370217732765 · Cited by 78
“There is a possibility that well-established tumor lines may adopt a “normal” phenotype when supplied with the right extracellular cues.(67) Human induced pluripotent stem cells (hiPSCs) would allow development of multiple tissues from the same “patient” and thus offer the option for personalized/precision medicine.”
Enabling peristalsis of human colon tumor organoids on microfluidic chips
Fang, G., Lu, H., Al-Nakashli, R., Chapman, R., Zhang, Y., Ju, L. A., Lin, G., Stenzel, M. H., & Jin, D. (2022) · Biofabrication · doi:10.1088/1758-5090/ac2ef9 · Cited by 77
Biomedical Application of Functional Materials in Organ-on-a-Chip
Ding, C., Chen, X., Kang, Q., & Yan, X. (2020) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2020.00823 · Cited by 88
“Moreover, the elasticity can be used to fabricate biomimetic cell culture scaffolds, such as the human lung-on-a-chip and gut-ona-chip with pneumatically controlled deformation (Figure 1A) (Huh et al., 2010; Kim et al., 2012) and the microvascular models (Choi et al., 2014; Zhang W. et al., 2016).”
A Gut-Brain Axis-on-a-Chip for studying transport across epithelial and endothelial barriers
Kim, M., Kim, D., & Sung, J. H. (2021) · Journal of Industrial and Engineering Chemistry · doi:10.1016/j.jiec.2021.06.021 · Cited by 84
Kidney-on-a-chip technology for renal proximal tubule tissue reconstruction
Nieskens, T. T. G., & Wilmer, M. J. G. (2016) · European Journal of Pharmacology · doi:10.1016/j.ejphar.2016.07.018 · Cited by 84
“In addition, mechanical forces as experienced by cells located in the lung and gut for example, can be incorporated by culturing cells on an elastic surface (Huh et al., 2010; Kim et al., 2012).”
Microfluidic Cell Chips for High-Throughput Drug Screening
Chi, C., Ahmed, A. H. R., Dereli‐Korkut, Z., & Wang, S. (2016) · Bioanalysis · doi:10.4155/bio-2016-0028 · Cited by 84
Peters, M. F., Choy, A. L., Pin, C., Leishman, D. J., Moisan, A., Ewart, L., Guzzie-Peck, P. J., Sura, R., Keller, D. A., Scott, C. W., et al. (2020) · Lab on a Chip · doi:10.1039/c9lc01107b · Cited by 76
Microfluidic lumen-based systems for advancing tubular organ modeling
Virumbrales-Muñoz, M., Ayuso, J. M., Gong, M. M., Humayun, M., Livingston, M. K., Lugo-Cintrón, K. M., McMinn, P., Álvarez-García, Y. R., & Beebe, D. J. (2020) · Chemical Society Reviews · doi:10.1039/d0cs00705f · Cited by 76
The Progress of Intestinal Epithelial Models from Cell Lines to Gut-On-Chip
Rahman, S., Ghiboub, M., Donkers, J. M., van de Steeg, E., van Tol, E. A. F., Hakvoort, T. B. M., & de Jonge, W. J. (2021) · International Journal of Molecular Sciences · doi:10.3390/ijms222413472 · Cited by 93
(GMO), E. P. O. G. M. O., Mullins, E. D., Bresson, J., Dalmay, T., Dewhurst, I. C., Epstein, M. M., Firbank, L. G., Guerche, P., Hejátko, J., Naegeli, H., et al. (2022) · EFSA Journal · doi:10.2903/j.efsa.2022.7044 · Cited by 102
“The data gaps identified by these authors could drive future research needs that might be directed into developing in vitro microfluids systems, human gut-on-achip devices (Kim et al., 2012), intestinal organoids (Leushacke and Baker, 2014), ex vivo models (Westerhout et al.”
In vitro toxicity assessment of oral nanocarriers
Ciappellano, S. G., Tedesco, E., Venturini, M., & Benetti, F. (2016) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2016.08.007 · Cited by 84
“Microfluidic systems also allow the use of microbial flora normally present in human intestine, approaching to closely-related physiological conditions [91].”
Stem Cells for Next Level Toxicity Testing in the 21st Century
Fritsche, E., Haarmann‐Stemmann, T., Kapr, J., Galanjuk, S., Hartmann, J., Mertens, P. R., Kämpfer, A. A. M., Schins, R. P. F., Tigges, J., & Koch, K. (2021) · Small · doi:10.1002/smll.202006252 · Cited by 75
Izadifar, Z., Charrez, B., Almeida, M., Robben, S., Pilobello, K. T., van der Graaf-Mas, J., Benz, M., Marquez, S. L., Ferrante, T. C., Shcherbina, K., et al. (2024) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2024.116683 · Cited by 83
Self-citationKim, H. J., Lee, J., Choi, J.-H., Bahinski, A., & Ingber, D. E. (2016) · Journal of Visualized Experiments · doi:10.3791/54344 · Cited by 69
Self-citationEngineering microphysiological immune system responses on chips
Miller, C. P., Shin, W., Ahn, E. H., Kim, H. J., & Kim, D.-H. (2020) · Trends in biotechnology · doi:10.1016/j.tibtech.2020.01.003 · Cited by 74
Self-citationLong-term flow through human intestinal organoids with the gut organoid flow chip (GOFlowChip)
Sidar, B., Jenkins, B. R., Huang, S., Spence, J. R., Walk, S. T., & Wilking, J. N. (2019) · Lab on a Chip · doi:10.1039/c9lc00653b · Cited by 73
In vitro models of intestinal epithelium: Toward bioengineered systems
Creff, J., Malaquin, L., & Besson, A. (2021) · Journal of Tissue Engineering · doi:10.1177/2041731420985202 · Cited by 86
Schneider, S., Gruner, D., Richter, A., & Loskill, P. (2021) · Lab on a Chip · doi:10.1039/d1lc00188d · Cited by 73
Establishment of physiologically relevant oxygen gradients in microfluidic organ chips
Grant, J. L., Lee, E., Almeida, M., Kim, S., LoGrande, N., Goyal, G., Sesay, A. M., Breault, D. T., Prantil‐Baun, R., & Ingber, D. E. (2022) · Lab on a Chip · doi:10.1039/d2lc00069e · Cited by 84
Self-citationModeling Crevicular Fluid Flow and Host‐Oral Microbiome Interactions in a Gingival Crevice‐on‐Chip
Makkar, H., Zhou, Y., Tan, K. S., Lim, C. T., & Sriram, G. (2022) · Advanced Healthcare Materials · doi:10.1002/adhm.202202376 · Cited by 81
Immune Organs and Immune Cells on a Chip: An Overview of Biomedical Applications
Morsink, M., Willemen, N., Leijten, J., Bansal, R., & Shin, S. (2020) · Micromachines · doi:10.3390/mi11090849 · Cited by 73
“[90], showing the peristaltic motion as a result of the two vacuum chambers.”
Jing, B., Wang, Z. A., Zhang, C., Deng, Q., Wei, J., Luo, Y., Zhang, X., Li, J., & Du, Y. (2020) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2020.00272 · Cited by 79
“…a computer-controlled FX5K Tension instrument and a syringe pump, Kim et al. built a physiologically relevant in vitro human “gut-on-a-chip,” which can achieve gut peristalsis and fluid flow, and that also has been used to study intestinal inflammation (Kim et al., 2012, 2016; Shin and Kim, 2018).”
InfluentialGut-on-a-chip for exploring the transport mechanism of Hg(II)
Wang, L., Han, J., Su, W., Li, A., Zhang, W., Li, H., Hu, H., Song, W., Xu, C., & Chen, J. (2023) · Microsystems & Nanoengineering · doi:10.1038/s41378-022-00447-2 · Cited by 79
de Haan, P., Ianovska, M. A., Mathwig, K., van Lieshout, G. A. A., Triantis, V., Bouwmeester, H., & Verpoorte, E. M. J. (2019) · Lab on a Chip · doi:10.1039/c8lc01080c · Cited by 77
Mimicking Human Pathophysiology in Organ‐on‐Chip Devices
Yeşil-Çeliktaş, Ö., Hassan, S., Miri, A. K., Maharjan, S., Al‐kharboosh, R., Quiñones‐Hinojosa, A., & Zhang, Y. S. (2018) · Advanced Biosystems · doi:10.1002/adbi.201800109 · Cited by 81
A Review of Biomaterials and Scaffold Fabrication for Organ-on-a-Chip (OOAC) Systems
Osório, L. A., Silva, E., & Mackay, R. E. (2021) · Bioengineering · doi:10.3390/bioengineering8080113 · Cited by 81
Kim, N. Y., Lee, H. Y., Choi, Y. Y., Mo, S. J., Jeon, S., Ha, J. H., Park, S. D., Shim, J.-J., Lee, J., & Chung, B. G. (2024) · Nano Convergence · doi:10.1186/s40580-024-00413-w · Cited by 86
Microscale Bioreactors for in situ characterization of GI epithelial cell physiology
Costello, C. M., Phillipsen, M. B., Hartmanis, L., Kwasnica, M. A., Chen, V., Hackam, D. J., Chang, M. W., Bentley, W. E., & March, J. C. (2017) · Scientific Reports · doi:10.1038/s41598-017-12984-2 · Cited by 78
Multi-corneal barrier-on-a-chip to recapitulate eye blinking shear stress forces
Abdalkader, R., & Kamei, K.-I. (2020) · Lab on a Chip · doi:10.1039/c9lc01256g · Cited by 72
Clinical translation of microbe‐based therapies: Current clinical landscape and preclinical outlook
Vargason, A. M., & Anselmo, A. C. (2018) · Bioengineering & Translational Medicine · doi:10.1002/btm2.10093 · Cited by 71
“The chip mimicked the key features of the GI tract such as the intestinal barrier properties, intestinal morphology (Figure 5e), anaerobic conditions, shear stress, and peristaltic forces.(92,93) Concomitant administration of the therapeutic microbes and antibiotics protected against lesion formation caused by pathoge…”
3D Bioprinting and its application to organ-on-a-chip
Park, J. Y., Jang, J., & Kang, H. (2018) · Microelectronic Engineering · doi:10.1016/j.mee.2018.08.004 · Cited by 79
Li, M., de Graaf, I. A. M., & Groothuis, G. M. M. (2016) · Expert Opinion on Drug Metabolism & Toxicology · doi:10.1517/17425255.2016.1125882 · Cited by 80
“[89] The gut microenvironment was also incorporated in the ‘human gut-on-a-chip’ microdevice [90,91] in which Caco-2 cells”
Design and engineering of organ-on-a-chip
Cho, S., Lee, S., & Ahn, S. I. (2023) · Biomedical Engineering Letters · doi:10.1007/s13534-022-00258-4 · Cited by 78
Uniaxial cell stretching device for live-cell imaging of mechanosensitive cellular functions
Shao, Y., Tan, X., Novitski, R., Muqaddam, M., List, P., Williamson, L., Fu, J., & Liu, A. P. (2013) · Review of Scientific Instruments · doi:10.1063/1.4832977 · Cited by 77
Drug absorption related nephrotoxicity assessment on an intestine-kidney chip
Li, Z., Su, W., Zhu, Y., Tao, T., Li, D., Peng, X., & Qin, J. (2017) · Biomicrofluidics · doi:10.1063/1.4984768 · Cited by 72
Bioengineered Systems and Designer Matrices That Recapitulate the Intestinal Stem Cell Niche
Wang, Y., Kim, R., Hinman, S. S., Zwarycz, B., Magness, S. T., & Allbritton, N. L. (2018) · Cellular and Molecular Gastroenterology and Hepatology · doi:10.1016/j.jcmgh.2018.01.008 · Cited by 77
The Ascendance of Microphysiological Systems to Solve the Drug Testing Dilemma
Dehne, E.-M., Hasenberg, T., & Marx, U. (2017) · Future Science OA · doi:10.4155/fsoa-2017-0002 · Cited by 68
Microfluidic Organs-on-a-Chip for Modeling Human Infectious Diseases
Wang, Y., Wang, P., & Qin, J. (2021) · Accounts of Chemical Research · doi:10.1021/acs.accounts.1c00411 · Cited by 69
Advances in organ-on-a-chip systems for modelling joint tissue and osteoarthritic diseases
Banh, L., Cheung, K. K., Chan, M. W. Y., Young, E. W. K., & Viswanathan, S. (2022) · Osteoarthritis and Cartilage · doi:10.1016/j.joca.2022.03.012 · Cited by 82
Proteomic and Metaproteomic Approaches to Understand Host–Microbe Interactions
Starr, A. E., Deeke, S. A., Li, L., Zhang, X., Daoud, R., Ryan, J., Ning, Z., Cheng, K., Nguyen, L. V. H., Abou-Samra, E., et al. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b04340 · Cited by 73
Ambrosini, Y. M., Park, Y., Jergens, A. E., Shin, W., Min, S., Atherly, T. A., Borcherding, D. C., Jang, J., Allenspach, K., Mochel, J. P., et al. (2020) · PLoS ONE · doi:10.1371/journal.pone.0231423 · Cited by 76
Self-citationKim, M., Hwang, J. C., Min, S., Park, Y., Kim, S., Kim, E., Seo, H., Chung, W. G., Lee, J., Cho, S., et al. (2022) · Nano Letters · doi:10.1021/acs.nanolett.2c02790 · Cited by 71
Tumor-on-a-chip models combined with mini-tissues or organoids for engineering tumor tissues
Hwangbo, H., Chae, S., Kim, W.-J., Jo, S., & Kim, G. (2023) · Theranostics · doi:10.7150/thno.90093 · Cited by 73
Emulating Host-Microbiome Ecosystem of Human Gastrointestinal Tract in Vitro
Park, G.-S., Park, M. H., Shin, W., Zhao, C., Sheikh, S., Oh, S. J., & Kim, H. J. (2017) · Stem Cell Reviews and Reports · doi:10.1007/s12015-017-9739-z · Cited by 73
“coli [15, 16, 18, 136, 138, 139] 322 Stem Cell Rev and Rep (2017) 13:321–334”
InfluentialSelf-citationKumar, V., & Varghese, S. (2019) · Advanced Healthcare Materials · doi:10.1002/adhm.201801198 · Cited by 68
An isogenic hiPSC-derived BBB-on-a-chip
Motallebnejad, P., Thomas, A., Swisher, S. L., & Azarin, S. M. (2019) · Biomicrofluidics · doi:10.1063/1.5123476 · Cited by 71
E. coli “super-contaminates” narrow ducts fostered by broad run-time distribution
Figueroa-Morales, N., Rivera, A., Soto, R., Lindner, A., Altshuler, E., & Clément, É. (2020) · Science Advances · doi:10.1126/sciadv.aay0155 · Cited by 67
Intracellular mechanisms of fungal space searching in microenvironments
Held, M., Kašpar, O., Edwards, C., & Nicolau, D. V. (2019) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1816423116 · Cited by 68
Santbergen, M. J. C., van der Zande, M., Gerssen, A., Bouwmeester, H., & Nielen, M. W. F. (2019) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-019-02336-6 · Cited by 72
Paggi, C. A., Venzac, B., Karperien, M., Leijten, J., & Gac, S. L. (2020) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2020.127917 · Cited by 75
“Noteworthy, such strain and fluid flow mechanical cues have been combined, to create more biomimetic environments, and to study the synergistic effect of various stimuli [22, 26-28].”
Ramadan, Q., & Jing, L. (2016) · Biomedical Microdevices · doi:10.1007/s10544-016-0035-5 · Cited by 69
In Vitro Immune Organs-on-Chip for Drug Development: A Review
Shanti, A., Teo, J., & Stefanini, C. (2018) · Pharmaceutics · doi:10.3390/pharmaceutics10040278 · Cited by 65
Organoid technologies for the study of intestinal microbiota–host interactions
Bozzetti, V., & Senger, S. (2022) · Trends in Molecular Medicine · doi:10.1016/j.molmed.2022.02.001 · Cited by 75
Microfluidic trends in drug screening and drug delivery
Feng, J., Neužil, J., Manz, A., Iliescu, C., & Neužil, P. (2022) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2022.116821 · Cited by 70
Min, S., Than, N., Shin, Y. C., Hu, G., Shin, W., Ambrosini, Y. M., & Kim, H. J. (2022) · Scientific Reports · doi:10.1038/s41598-022-27300-w · Cited by 69
Self-citationMechanisms of uptake and transport of particulate formulations in the small intestine
Delon, L., Gibson, R. J., Prestidge, C. A., & Thierry, B. (2022) · Journal of Controlled Release · doi:10.1016/j.jconrel.2022.02.006 · Cited by 64
A biodegradable microvessel scaffold as a framework to enable vascular support of engineered tissues
Ye, X., Lu, L., Kolewe, M. E., Park, H., Larson, B. L., Kim, E. S., & Freed, L. E. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2013.09.039 · Cited by 64
Ashammakhi, N. A., Darabi, M. A., Çelebi‐Saltik, B., Tutar, R., Hartel, M. C., Lee, J., Hussein, S. M., Goudie, M. J., Cornelius, M. B., Dokmeci, M. R., et al. (2019) · Small Methods · doi:10.1002/smtd.201900589 · Cited by 74
Organoids/organs-on-a-chip: new frontiers of intestinal pathophysiological models
Wu, L., Ai, Y., Xie, R., Xiong, J., Wang, Y., & Liang, Q. (2023) · Lab on a Chip · doi:10.1039/d2lc00804a · Cited by 69
Evaluating Human Intestinal Cell Lines for Studying Dietary Protein Absorption
Jochems, P., Garssen, J., Van Keulen, A., Masereeuw, R., & Jeurink, P. (2018) · Nutrients · doi:10.3390/nu10030322 · Cited by 64
Guan, A., Hamilton, P., Wang, Y., Gorbet, M., Li, Z., & Phillips, K. S. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-017-0045 · Cited by 68
Colon Cancer: From Epidemiology to Prevention
Katsaounou, K., Nicolaou, E., Vogazianos, P., Brown, C., Stavrou, M., Teloni, S., Hatzis, P., Agapiou, A., Fragkou, E., Tsiaoussis, G. I., et al. (2022) · Metabolites · doi:10.3390/metabo12060499 · Cited by 75
Organ-on-a-Chip Applications in Microfluidic Platforms
An, L., Liu, Y., & Liu, Y. (2025) · Micromachines · doi:10.3390/mi16020201 · Cited by 79
Human immunity in vitro — Solving immunogenicity and more
Giese, C., & Marx, U. (2014) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2013.12.011 · Cited by 67
“Another impressive microfluidic gut has been reported by Kim and colleagues [186].”
A biologically inspired lung-on-a-chip device for the study of protein-induced lung inflammation
Punde, T. H., Wu, W., Lien, P.-C., Chang, Y., Kuo, P.-H., Chang, M. D., Lee, K., Huang, C., Kuo, H., Chan, Y.-F., et al. (2014) · Integrative Biology · doi:10.1039/c4ib00239c · Cited by 67
Yasotharan, S., Pinto, S., Sled, J. G., Bolz, S.-S., & Günther, A. (2015) · Lab on a Chip · doi:10.1039/c5lc00021a · Cited by 62
Metadata
- Authors
- Kim, H. J., Huh, D., Hamilton, G., & Ingber, D. E.
- Affiliations
- Harvard University (US)
- Boston Children's Hospital (US)
- Corresponding author
- Ingber, Donald E.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2012
- Volume
- 12
- Issue
- 12
- Pages
- 2165
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2168752825
- Cited by
- 1,734
- References
- 65
- Citations by year
- 2026: 114 · 2025: 130 · 2024: 163 · 2023: 150 · 2022: 150 · 2021: 185 · 2020: 154 · 2019: 154 · 2018: 133 · 2017: 130 · 2016: 84 · 2015: 61 · 2014: 54 · 2013: 57 · 2012: 13
- FWCI
- 33.74
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Lab on a Chip (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Harvard University
- Hansjörg Wyss Institute for Biologically Inspired Engineering, Harvard University
- National Institute of Environmental Health Sciences (R01ES016665, ES016665-01A1)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Health Sciences › Medicine › Surgery › Tissue Engineering and Regenerative Medicine
- Keywords
- gut-on-a-chip, intestinal epithelium, Caco-2 cells, peristalsis, cyclic strain, microfluidics, extracellular matrix, Lactobacillus rhamnosus GG, intestinal barrier function, epithelial polarization, low shear stress, drug testing, alternatives to animal testing
- MeSH terms
- Aminopeptidases, beta-Galactosidase, Dimethylpolysiloxanes, Epithelial Cells, Humans, Intestines, Models, Biological, Caco-2 Cells, Tissue Engineering, Biomimetic Materials, Lacticaseibacillus rhamnosus, Metagenome
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.