Human gut-on-a-chip inhabited by microbial flora that experiences intestinal peristalsis-like motions and flow
The DOI matches its Crossref record; 65 of the 65 references it cites were found in a registry or an index.
Abstract
Development of an in vitro living cell-based model of the intestine that mimics the mechanical, structural, absorptive, transport and pathophysiological properties of the human gut along with its crucial microbial symbionts could accelerate pharmaceutical development, and potentially replace animal testing. Here, we describe a biomimetic 'human gut-on-a-chip' microdevice composed of two microfluidic channels separated by a porous flexible membrane coated with extracellular matrix (ECM) and lined by human intestinal epithelial (Caco-2) cells that mimics the complex structure and physiology of living intestine. The gut microenvironment is recreated by flowing fluid at a low rate (30 μL h(-1)) producing low shear stress (0.02 dyne cm(-2)) over the microchannels, and by exerting cyclic strain (10%; 0.15 Hz) that mimics physiological peristaltic motions. Under these conditions, a columnar epithelium develops that polarizes rapidly, spontaneously grows into folds that recapitulate the structure of intestinal villi, and forms a high integrity barrier to small molecules that better mimics whole intestine than cells in cultured in static Transwell models. In addition, a normal intestinal microbe (Lactobacillus rhamnosus GG) can be successfully co-cultured for extended periods (>1 week) on the luminal surface of the cultured epithelium without compromising epithelial cell viability, and this actually improves barrier function as previously observed in humans. Thus, this gut-on-a-chip recapitulates multiple dynamic physical and functional features of human intestine that are critical for its function within a controlled microfluidic environment that is amenable for transport, absorption, and toxicity studies, and hence it should have great value for drug testing as well as development of novel intestinal disease models.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“this 2-dimensional (2D) culture format fails to recapitulate physiological 3-dimensional (3D) intestinal cell and tissue morphology or re-establish other key intestinal differentiated functions (eg, mucus production, villi formation, cytochrome P-450-based drug metabolism).”
From Microfluidic Organ-on-a-Chip Models of Human Intestine (2018) · cites this paper as [16]
In the citing paper
“These conventional static models also cannot support the coculture of commensal microbiome with human intestinal cells, which are critical for gut physiology,16 because the bacteria rapidly overgrow and contaminate the human cell cultures within a day.”
From Microfluidic Organ-on-a-Chip Models of Human Intestine (2018) · cites this paper as [16]
In the citing paper
“In fact, barrier function was shown to increase when the intestinal epithelium was cocultured with L rhamnosus GG.16”
From Microfluidic Organ-on-a-Chip Models of Human Intestine (2018) · cites this paper as [16]
In the citing paper
“Importantly, because the Gut Chip has continuous fluid flow, villi formation, and mucus production, it is also possible to coculture living commensal microbes (eg, Lactobacillus rhamnosus GG)16 or the VSL#3 clinical probiotic formulation containing 8 different microbial strains42) in direct contact with the intestinal epithelial cells within the lumen of the parenchymal channel for weeks in vitro”
From Microfluidic Organ-on-a-Chip Models of Human Intestine (2018) · cites this paper as [16]
In the citing paper
“Importantly, the probiotic L rhamnosus GG was shown to increase intestinal barrier function when cocultured in the lumen of the intestinal epithelial channel of the human Gut Chip,16”
From Microfluidic Organ-on-a-Chip Models of Human Intestine (2018) · cites this paper as [16]
5 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Turnbaugh, P. J., Ley, R. E., Hamady, M., Fraser-Liggett, C. M., Knight, R., & Gordon, J. I. (2007) · Nature · doi:10.1038/nature06244 · Cited by 6,091
The gut microbiota shapes intestinal immune responses during health and disease
Round, J. L., & Mazmanian, S. K. (2009) · Nature Reviews Immunology · doi:10.1038/nri2515 · Cited by 5,029
Reconstituting organ-level lung functions on a chip
Huh, D., Matthews, B. D., Mammoto, A., Montoya-Zavala, M., Hsin, H. Y., & Ingber, D. E. (2010) · Science · doi:10.1126/science.1188302 · Cited by 4,250
Self-citationIntestinal mucosal barrier function in health and disease
Turner, J. R. (2009) · Nature reviews. Immunology · doi:10.1038/nri2653 · Cited by 3,952
Membrane transporters in drug development
The International Transporter Consortium, Giacomini, K. M., Huang, S.-M., Tweedie, D. J., Benet, L. Z., Brouwer, K. L. R., Chu, X., Dahlin, A., Evers, R., Fischer, V., et al. (2010) · Nature Reviews Drug Discovery · doi:10.1038/nrd3028 · Cited by 3,340
Occludin: a novel integral membrane protein localizing at tight junctions.
Furuse, M., Hirase, T., Itoh, M., Nagafuchi, A., Yonemura, S., Tsukita, S., & Tsukita, S. (1993) · The Journal of cell biology · doi:10.1083/jcb.123.6.1777 · Cited by 2,580
Hidalgo, I. J., Raub, T. J., & Borchardt, R. T. (1989) · Gastroenterology · doi:10.1016/s0016-5085(89)80072-1 · Cited by 2,396
Concordance of the toxicity of pharmaceuticals in humans and in animals
Olson, H., Betton, G., Robinson, D., Thomas, K., Monro, A., Kolaja, G., Lilly, P., Sanders, J., Sipes, G., Bracken, W., et al. (2000) · Regulatory Toxicology and Pharmacology · doi:10.1006/rtph.2000.1399 · Cited by 2,050
Determination of drug permeability and prediction of drug absorption in Caco-2 monolayers
Hubatsch, I., Ragnarsson, E. G. E., & Artursson, P. (2007) · Nature Protocols · doi:10.1038/nprot.2007.303 · Cited by 1,499
Yee, S. (1997) · Pharmaceutical Research · doi:10.1023/a:1012102522787 · Cited by 1,030
Research works printed but not linked: 3
- Ho, 1993, Cancer Res., 53, 641
- Dai, 2012, Int. J. Mol. Med, 29, 202
- Coconnier, 1993, FEMS Microbiol. Lett., 110, 299, 10.1111/j.1574-6968.1993.tb06339.x · doi:10.1111/j.1574-6968.1993.tb06339.x · Paper page
Cited by
Items 601–700 of 1,004
Three-tissue microphysiological system for studying inflammatory responses in gut-liver Axis
Jeon, J., Choi, N., Lee, S. H., & Sung, J. H. (2020) · Biomedical Microdevices · doi:10.1007/s10544-020-00519-y · Cited by 41
“A variety of MPSs reportedly mimic in vivo environments of the gut or liver (Chi et al. 2015; Choe et al. 2017; Kim et al. 2012; Lee et al. 2017a; Lee and Sung 2018a).”
Ferreira, D. A., Rothbauer, M., Conde, J. P., Ertl, P., Oliveíra, C., & Granja, P. L. (2021) · Advanced Science · doi:10.1002/advs.202003273 · Cited by 45
Kulthong, K., Hooiveld, G. J. E. J., Duivenvoorde, L. P. M., Estruch, I. M., Marin, V., van der Zande, M., & Bouwmeester, H. (2021) · Scientific Reports · doi:10.1038/s41598-021-82853-6 · Cited by 45
Organ-on-chip applications in drug discovery: an end user perspective
Clapp, N., Amour, A., Rowan, W. C., & Candarlioglu, P. L. (2021) · Biochemical Society Transactions · doi:10.1042/bst20210840 · Cited by 47
Bredeck, G., Halamoda‐Kenzaoui, B., Bogni, A., Lipsa, D., & Bremer‐Hoffmann, S. (2021) · Environment International · doi:10.1016/j.envint.2021.106921 · Cited by 42
Moreira, A., Müller, M., Costa, P. F., & Kohl, Y. (2021) · Advanced Biology · doi:10.1002/adbi.202101139 · Cited by 52
Patient‐Derived Microphysiological Systems for Precision Medicine
Ko, J., Song, J., Choi, N., & Kim, H. N. (2023) · Advanced Healthcare Materials · doi:10.1002/adhm.202303161 · Cited by 46
Self-citationRecent Advances in Gut‐ and Gut–Organ‐Axis‐on‐a‐Chip Models
Kim, R., & Sung, J. H. (2024) · Advanced Healthcare Materials · doi:10.1002/adhm.202302777 · Cited by 53
Bacteriophage defends murine gut from Escherichia coli invasion via mucosal adherence
Wu, J., Fu, K., Hou, C., Wang, Y., Ji, C., Xue, F., Ren, J., Dai, J., Barr, J. J., & Tang, F. (2024) · Nature Communications · doi:10.1038/s41467-024-48560-2 · Cited by 43
Xu, F., Jin, H., Liu, L., Yang, Y., Cen, J., Wu, Y., Chen, S., & Sun, D. (2024) · Microsystems & Nanoengineering · doi:10.1038/s41378-024-00692-7 · Cited by 45
Biomaterial-assisted organoid technology for disease modeling and drug screening
Shao, Y., Wang, J., Jin, A., Jiang, S., Lei, L., & Liu, L. (2024) · Materials Today Bio · doi:10.1016/j.mtbio.2024.101438 · Cited by 49
Brandauer, K., Schweinitzer, S., Lorenz, A., Krauß, J., Schobesberger, S., Frauenlob, M., & Ertl, P. (2025) · Lab on a Chip · doi:10.1039/d4lc01011f · Cited by 46
Microfluidics for cell-cell interactions: A review
Li, R., Lv, X., Zhang, X., Saeed, O., & Deng, Y. (2015) · Frontiers of Chemical Science and Engineering · doi:10.1007/s11705-015-1550-2 · Cited by 44
“Microfluidics facilitate the simulation of intestinal microenvironment and the chip usually contains membrane with epithelial cells and pathogenic or nonpathogenic bacteria co-existence [77,78].”
Engineering Solutions for Representative Models of the Gastrointestinal Human-Microbe Interface
Eain, M. M. G., Baginska, J., Greenhalgh, K., Fritz, J. V., Zenhausern, F., & Wilmes, P. (2017) · Engineering · doi:10.1016/j.eng.2017.01.011 · Cited by 39
“These involve the culture of human intestinal epithelial cells in hydrogels [21], in polydimethylsiloxane (PDMS)-based chips [22,23], or on polyamide membranes [24].”
Henrich, T. J., Deeks, S. G., & Pillai, S. K. (2017) · The Journal of Infectious Diseases · doi:10.1093/infdis/jiw648 · Cited by 44
Unlocking the Potential of Organ‐on‐Chip Models through Pumpless and Tubeless Microfluidics
Delon, L., Nilghaz, A., Cheah, E., Prestidge, C. A., & Thierry, B. (2020) · Advanced Healthcare Materials · doi:10.1002/adhm.201901784 · Cited by 42
Wright, L., Barnes, T. J., & Prestidge, C. A. (2020) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2020.119488 · Cited by 41
Refining Host-Pathogen Interactions: Organ-on-Chip Side of the Coin
Baddal, B., & Marrazzo, P. (2021) · Pathogens · doi:10.3390/pathogens10020203 · Cited by 41
“One of the first studies reporting the co-culture of the commensal bacterium Lactobacillus rhamnosus GG within the gut-on-a-chip system was described in 2012, and an improvement of the intestinal barrier function was observed as a similar phenomenon that happens with probiotic bacteria strains in humans [75,76].”
Kopec, A. K., Yokokawa, R., Khan, N., Horii, I., Finley, J. E., Bono, C. P., Donovan, C., Roy, J., Harney, J., Burdick, A. D., et al. (2021) · The Journal of Toxicological Sciences · doi:10.2131/jts.46.99 · Cited by 39
“For example, a typical assay was performed by seeding Caco2 on collagen I and a Matrigel-coated porous membrane ( Kim et al., 2012 ).”
Signore, M. A., Pascali, C. D., Giampetruzzi, L., Siciliano, P. A., & Francioso, L. N. (2021) · Sensing and Bio-Sensing Research · doi:10.1016/j.sbsr.2021.100443 · Cited by 45
Organs-on-Chips Platforms Are Everywhere: A Zoom on Biomedical Investigation
Zommiti, M., Connil, N., Tahrioui, A., Groboillot, A., Barbey, C., Konto‐Ghiorghi, Y., Lesouhaitier, O., Chevalier, S., & Feuilloley, M. G. J. (2022) · Bioengineering · doi:10.3390/bioengineering9110646 · Cited by 47
Current in Vitro and Animal Models for Understanding Foods: Human Gut–Microbiota Interactions
Li, C., & Zhang, X. (2022) · Journal of Agricultural and Food Chemistry · doi:10.1021/acs.jafc.2c04238 · Cited by 46
Li, B., Tang, Y., Huang, Z., Ma, L., Song, J., & Xue, L. (2025) · Protein & Cell · doi:10.1093/procel/pwaf058 · Cited by 57
“…the inaugural intestine-on-a-chip combined human intestinal epithelial Caco-2 cells and microbial symbionts to recapitulate human intestinal physiology (Kim et al., 2012), followed by a kidney-on-a-chip was constructed for drug transport and nephrotoxicity assessment in 2013 (Jang et al., 2013).”
3D functional and perfusable microvascular networks for organotypic microfluidic models
Bersini, S., & Moretti, M. (2015) · Journal of Materials Science Materials in Medicine · doi:10.1007/s10856-015-5520-5 · Cited by 45
“Other organs-on-a-chip were designed to mimic the minimal functional units of kidney [68] and gut [69, 70].”
Gastrointestinal microphysiological systems
Blutt, S. E., Broughman, J. R., Zou, W. Y., Zeng, X., Karandikar, U. C., In, J. G., Zachos, N. C., Kovbasnjuk, O. N., Donowitz, M., & Estes, M. K. (2017) · Experimental Biology and Medicine · doi:10.1177/1535370217710638 · Cited by 43
“The probiotic, Lactobacillus rhamnosus, was introduced into an MPS containing transformed cells resulting in colonization of the MPS with the organism and positive effects on the cells such as increased barrier function.(44,74) Others have looked at the effects of microbial communities on intestinal enteroid growth an…”
Peck, R. W., Hinojosa, C. D., & Hamilton, G. A. (2020) · Clinical Pharmacology & Therapeutics · doi:10.1002/cpt.1688 · Cited by 38
Self-citationIn Vitro Models of Intestine Innate Immunity
Roh, T. T., Chen, Y., Rudolph, S., Gee, M. M., & Kaplan, D. L. (2020) · Trends in biotechnology · doi:10.1016/j.tibtech.2020.07.009 · Cited by 40
Blake, R., Jensen, K., Mabbott, N. A., Hope, J. C., & Stevens, J. M. (2022) · Frontiers in Veterinary Science · doi:10.3389/fvets.2022.921160 · Cited by 41
Lacroix, C., de Wouters, T., & Chassard, C. (2015) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2014.12.009 · Cited by 49
Kang, S. G., Choi, Y. Y., Mo, S. J., Kim, T. H., Ha, J. H., Hong, D. K., Lee, H., Park, S. D., Shim, J.-J., Lee, J.-L., et al. (2023) · Nano Convergence · doi:10.1186/s40580-022-00350-6 · Cited by 37
Flavonoids and cellular stress: a complex interplay affecting human health
Vissenaekens, H., Criel, H., Grootaert, C., Raes, K., Smagghe, G. J., & Camp, J. V. (2021) · Critical Reviews in Food Science and Nutrition · doi:10.1080/10408398.2021.1929822 · Cited by 44
“For example, a ‘human gut-on-a-chip’ microdevice composed of two microfluidic channels separated by a filter coated with extracellular matrix and lined by Caco-2 cells, results in an epithelium with intestinal villi and barrier integrity that mimics the whole intestine (Kim et al. 2012).”
Geng, T., Bao, S., Sun, X., Ma, D., Zhang, H., Ge, Q., Liu, X., & Ma, T. (2022) · Food Chemistry · doi:10.1016/j.foodchem.2022.134060 · Cited by 42
Modeling mucus physiology and pathophysiology in human organs-on-chips
Izadifar, Z., Sontheimer-Phelps, A., Lubamba, B., Bai, H., Fadel, C. W., Stejskalová, A., Özkan, A., Dasgupta, Q., Bein, A., Junaid, A., et al. (2022) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2022.114542 · Cited by 39
Self-citationGarza-García, L. D., García‐López, E., Camacho-León, S., Rocha-Pizaña, M. D. R., López‐Pacheco, F., López-Meza, J., Araíz-Hernández, D., Tapia-Mejía, E. J., Santiago, G. T., Rodriguez, C. A., et al. (2014) · Lab on a Chip · doi:10.1039/c3lc51301g · Cited by 36
Soenksen, L. R., Kassis, T., Noh, M., Griffith, L. G., & Trumper, D. L. (2018) · Lab on a Chip · doi:10.1039/c7lc01223c · Cited by 36
Bioreactor With Electrically Deformable Curved Membranes for Mechanical Stimulation of Cell Cultures
Costa, J. S., Ghilardi, M., Mamone, V., Ferrari, V., Busfield, J. J. C., Ahluwalia, A. D., & Carpi, F. (2020) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2020.00022 · Cited by 38
“Other systems are designed to mechanically stimulate cells at the microscopic scale, so as to study the response of few or even single cells, with so-called organ-on-a-chip devices (Akbari and Shea 2012,a; Akbari and Shea 2012,b; Clark et al. 2000; Kim et al. 2012; Pavesi et al. 2015).”
Multi-Enzyme Systems in Flow Chemistry
Fernandes, P. C. D. B., & de Carvalho, C. C. C. R. (2021) · Processes · doi:10.3390/pr9020225 · Cited by 37
Ustun, M., Dabbagh, S. R., Ilci, I., Onder, T. B., & Taşoğlu, S. (2021) · Micromachines · doi:10.3390/mi12050490 · Cited by 43
Shanmugam, D. K., Anitha, S., Souresh, V., Madhavan, Y., Sampath, S., Venugopal, D. C., & Saravanan, M. (2023) · Materials Technology · doi:10.1080/10667857.2023.2242732 · Cited by 46
“The Organs-on-chip (OOC) that emerged in 2010 is regarded as an extremely promising prospect for studying the mechanisms behind drug screening and organ functioning platforms with future developments to be utilised for targeted therapy and clinical diagnostics (Figure 3) [25].”
An Intelligent Intestine‐on‐a‐Chip for Rapid Screening of Probiotics with Relief‐Enteritis Function
Wu, J., Zhang, B., Liu, X., Gu, W., Xu, F., Wang, J., Liu, Q., Wang, R., Hu, Y., Liu, J., et al. (2024) · Advanced Materials · doi:10.1002/adma.202408485 · Cited by 35
A Novel Modular Bioreactor to In Vitro Study the Hepatic Sinusoid
Illa, X., Vila, S., Yeste, J., Peralta, C., Gracia-Sancho, J., & Villa, R. (2014) · PLoS ONE · doi:10.1371/journal.pone.0111864 · Cited by 36
“Organ on a chip devices have been developed to study the pathophysiology of a variety of organs, including lung [12], liver [13], gut [14] and kidney [15].”
Organoids, organs-on-chips and other systems, and microbiota
May, S., Evans, S., & Parry, L. (2017) · Emerging Topics in Life Sciences · doi:10.1042/etls20170047 · Cited by 36
Recent advances in an organ-on-a-chip: biomarker analysis and applications
Li, X., & Tian, T. (2018) · Analytical Methods · doi:10.1039/c8ay00970h · Cited by 38
Microfluidics for the study of mechanotransduction
Griffith, C. M., Huang, S. A., Cho, C., Khare, T. M., Rich, M. J., Lee, G.-H., Ligler, F. S., Diekman, B. O., & Polacheck, W. J. (2020) · Journal of Physics D Applied Physics · doi:10.1088/1361-6463/ab78d4 · Cited by 37
“Microfluidic technology and lithography approaches for patterning compliant materials have expanded the understanding of the role of strain in biological processes, particularly in the lung [100], gut [101,102], and cardiovascular system [103,104].”
Sun, W., Wu, W., Jiang, N., Ge, X., Zhang, Y., Han, J., Guo, X., Zhou, L., & Yang, H. (2022) · Viruses · doi:10.3390/v14030452 · Cited by 31
Perspectives on organ-on-a-chip technology for natural products evaluation
Wang, X., Miao, Y., Zhao, X.-M., Liu, X., Hu, Y.-W., & Deng, D. (2024) · Food & medicine homology. · doi:10.26599/fmh.2024.9420013 · Cited by 43
Makkar, H., & Sriram, G. (2025) · Lab on a Chip · doi:10.1039/d4lc00871e · Cited by 40
Evaluation of Drug Permeation Enhancement by Using In Vitro and Ex Vivo Models
Steyn, D., Haasbroek‐Pheiffer, A., Pheiffer, W., Weyers, M., Niekerk, S. E. V., Hamman, J. H., & van Staden, D. (2025) · Pharmaceuticals · doi:10.3390/ph18020195 · Cited by 47
Extracellular Microreactor for the Depletion of Phenylalanine Toward Phenylketonuria Treatment
Hosta‐Rigau, L., York-Durán, M. J., Kang, T. S., & Städler, B. (2015) · Advanced Functional Materials · doi:10.1002/adfm.201404180 · Cited by 35
Beiβner, N., Mattern, K., Dietzel, A. H., & Reichl, S. (2017) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2017.03.021 · Cited by 44
An on-chip intestine-liver model for multiple drugs absorption and metabolism behavior simulation
Jie, M., Lin, H., He, Z., Liu, H., Li, H., & Lin, J. (2017) · Science China Chemistry · doi:10.1007/s11426-017-9167-0 · Cited by 34
Microengineered Organ-on-a-chip Platforms towards Personalized Medicine
Kankala, R. K., Wang, S., & Chen, A. (2019) · Current Pharmaceutical Design · doi:10.2174/1381612825666190222143542 · Cited by 41
Pocock, K. J., Delon, L., Khatri, A., Prestidge, C. A., Gibson, R. J., Barbe, C., & Thierry, B. (2019) · Biomaterials Science · doi:10.1039/c9bm00058e · Cited by 35
Hawkins, K. G., Casolaro, T. C., Brown, J. A., Edwards, D. A., & Wikswo, J. P. (2020) · Clinical Pharmacology & Therapeutics · doi:10.1002/cpt.1870 · Cited by 39
Pharmacokinetics‐On‐a‐Chip: In Vitro Microphysiological Models for Emulating of Drugs ADME
Ramadan, Q., Fardous, R. S., Hazaymeh, R., Alshmmari, S. K., & Zourob, M. M. (2021) · Advanced Biology · doi:10.1002/adbi.202100775 · Cited by 42
Rapid assembly of PMMA microfluidic devices with PETE membranes for studying the endothelium
Persson, H., Park, S., Mohan, M. D., Cheung, K. K., Simmons, C. A., & Young, E. W. K. (2021) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2021.131342 · Cited by 35
Hong, S., Jung, Y., Yen, R., Chan, H. F., Leong, K. W., Truskey, G. A., & Zhao, X. (2013) · Lab on a Chip · doi:10.1039/c3lc51076j · Cited by 36
In Vitro Human Gastrointestinal Tract Simulation Systems: A Panoramic Review
Dixit, Y. M., Kanojiya, K., Bhingardeve, N., Ahire, J. J., & Saroj, D. B. (2023) · Probiotics and Antimicrobial Proteins · doi:10.1007/s12602-023-10052-y · Cited by 40
“Kim et al. [91] built a human gut-on-a-chip with mechanical characteristics including peristalsis and microbial growth for possible use in drug discovery and intestinal illness models.”
Yang, W., Li, T., Liao, S., Zhou, J., & Huang, L. (2024) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2024.117569 · Cited by 47
Advances in the Model Structure of In Vitro Vascularized Organ-on-a-Chip
Yin, H., Wang, Y., Liu, N., Zhong, S., Li, L., Zhang, Q., Liu, Z., & Yue, T. (2024) · Cyborg and Bionic Systems · doi:10.34133/cbsystems.0107 · Cited by 43
“Porous membranes are frequently employed in multilayer vertical coculture organ chips, such as the renowned lung-on-a-chip [34] and gut on-a-chip [109].”
Skin-on-a-chip technologies towards clinical translation and commercialization
Ismayilzada, N., Tarar, C., Dabbagh, S. R., Tokyay, B. K., Dilmani, S. A., Sokullu, E., Abaci, H. E., & Taşoğlu, S. (2024) · Biofabrication · doi:10.1088/1758-5090/ad5f55 · Cited by 43
“Shear stress refers to a frictional force applied by a parallel flow of fluid and is known to induce morphological changes and activate signaling cascades in cells exposed to it [124–126].”
Bertorello, S., Cei, F., Fink, D., Niccolai, E., & Amedei, A. (2024) · Microorganisms · doi:10.3390/microorganisms12091828 · Cited by 37
“Nevertheless, with ongoing advancements and optimizations, these models have the potential to greatly enhance scientific research and deepen our understanding of gut, microbiota, and immune system interactions [217].”
Developing microphysiological systems for use as regulatory tools – challenges and opportunities
Andersen, M. E., Betts, K., Dragan, Y., Fitzpatrick, S., Goodman, J. L., Hartung, T., Himmelfarb, J., Ingber, D. E., Jacobs, A., Kavlock, R., et al. (2014) · ALTEX · doi:10.14573/altex.1405151 · Cited by 36
“Gut-on-a-Chip microenvironment induces human intestinal cells to undergo villus differentiation.”
InfluentialRapid large area fabrication of multiscale through-hole membranes
Tahk, D., Paik, S., Lim, J., Bang, S., Oh, S., Ryu, H., & Jeon, N. L. (2017) · Lab on a Chip · doi:10.1039/c7lc00363c · Cited by 34
Sakharov, D. A., Maltseva, D. V., Knyazev, E. N., Nikulin, S. V., Poloznikov, A. A., Shilin, S. A., Baranova, A. V., Tsypina, I. M., & Tonevitsky, A. (2019) · BMC Systems Biology · doi:10.1186/s12918-019-0686-y · Cited by 33
Recent progress of microfluidic technology for pharmaceutical analysis
Jia, X., Yang, X., Luo, G., & Liang, Q. (2021) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2021.114534 · Cited by 39
Optimization of 3-D organotypic primary colonic cultures for organ-on-chip applications
Ahmad, A. A., Wang, Y., Gracz, A. D., Sims, C. E., Magness, S. T., & Allbritton, N. L. (2014) · Journal of Biological Engineering · doi:10.1186/1754-1611-8-9 · Cited by 38
The motility of Entamoeba histolytica: finding ways to understand intestinal amoebiasis
Aguilar‐Rojas, A., Olivo‐Marín, J., & Guillén, N. (2016) · Current Opinion in Microbiology · doi:10.1016/j.mib.2016.07.016 · Cited by 35
Engineering in vitro human tissue models through bio-design and manufacturing
Zhang, Y. S., & Khademhosseini, A. (2020) · Bio-Design and Manufacturing · doi:10.1007/s42242-020-00080-w · Cited by 36
Li, Y., Wong, I. Y., & Guo, M. (2022) · Small · doi:10.1002/smll.202107305 · Cited by 43
Phage lysins for intestinal microbiome modulation: current challenges and enabling techniques
Pottie, I., Vázquez, R., de Wiele, T. V., & Briers, Y. (2024) · Gut Microbes · doi:10.1080/19490976.2024.2387144 · Cited by 38
Organs-on-chips and Its Applications
Sun, W., Chen, Y., Luo, G., Zhang, M., Zhang, H., Wang, Y., & Hu, P. (2016) · Chinese Journal of Analytical Chemistry · doi:10.1016/s1872-2040(16)60920-9 · Cited by 42
Novel Microfluidic Colon with an Extracellular Matrix Membrane
Wang, C., Tanataweethum, N., Karnik, S. J., & Bhushan, A. (2018) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.7b00883 · Cited by 35
Advanced Microengineered Lung Models for Translational Drug Discovery
Niemeyer, B. F., Zhao, P., Tuder, R. M., & Benam, K. H. (2018) · SLAS DISCOVERY · doi:10.1177/2472555218760217 · Cited by 34
Mestres, G., Pérez, R. A., D’Elía, N. L., & Barbe, L. (2019) · Biomedical Physics & Engineering Express · doi:10.1088/2057-1976/ab1033 · Cited by 35
Low, L. A., Sutherland, M. L., Lumelsky, N. L., Selimović, Š., Lundberg, M. S., & Tagle, D. A. (2020) · Advances in experimental medicine and biology · doi:10.1007/978-3-030-36588-2_3 · Cited by 37
Tissue Engineering for Musculoskeletal Regeneration and Disease Modeling
Li, Z. A., Xiang, S., Li, E. N., Fritch, M. R., Alexander, P. G., Lin, H., & Tuan, R. S. (2020) · Handbook of experimental pharmacology · doi:10.1007/164_2020_377 · Cited by 37
Lei, F., Liang, M., Liu, Y., Huang, H., Li, H., & Dong, H. (2021) · Advanced Fiber Materials · doi:10.1007/s42765-021-00091-x · Cited by 35
Evolution of a confluent gut epithelium under on-chip cyclic stretching
Gérémie, L., İlker, E., Bernheim-Dennery, M., Cavaniol, C., Viovy, J., Vignjevic, D. M., Joanny, J., & Descroix, S. (2022) · Physical Review Research · doi:10.1103/physrevresearch.4.023032 · Cited by 31
Favero, G. D., Zaharescu, R., & Marko, D. (2018) · Archives of Toxicology · doi:10.1007/s00204-018-2317-6 · Cited by 34
Lab-on-a-chip technology and microfluidics
Francesko, A., Cardoso, V. F., & Lanceros-Méndez, S. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-812659-2.00001-6 · Cited by 43
Revolutionizing the female reproductive system research using microfluidic chip platform
Yan, J., Wu, T., Zhang, J., Gao, Y., Wu, J., & Wang, S. (2023) · Journal of Nanobiotechnology · doi:10.1186/s12951-023-02258-7 · Cited by 38
“Over the past decade, several organs-on-chips for tissue or organ models have been developed, such as for the lung [54–61], kidney [62–66], intestine [67–71], liver [72–77], heart [78– 81], blood vessel [82–87], skin [88–91].”
Wang, H., Li, X., Shi, P., You, X., & Zhao, G. (2024) · Materials Today Bio · doi:10.1016/j.mtbio.2024.101079 · Cited by 47
“Reproducing the in vivo -like microenvironment [33,36,38] 4.”
InfluentialGleeson, J. P., Zhang, S. Y., Subelzú, N., Ling, J., Nissley, B. P., Ong, W. S. Y., Nofsinger, R., & Kesisoglou, F. (2024) · Molecular Pharmaceutics · doi:10.1021/acs.molpharmaceut.4c00210 · Cited by 35
The third dimension: new developments in cell culture models for colorectal research
Pereira, J., Awatade, N. T., Loureiro, C. A., Matos, P., Amaral, M. D., & Jordan, P. (2016) · Cellular and Molecular Life Sciences · doi:10.1007/s00018-016-2258-2 · Cited by 36
“achieved with this gut-on-chip technique [10, 48, 49].”
Chip modularity enables molecular information access from organ-on-chip devices with quality control
Shang, W., Chen, C., Lo, K., Payne, G. F., & Bentley, W. E. (2019) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2019.05.030 · Cited by 35
“Once assembled, this film can then store charge for extended periods and also “write” charge under an applied voltage, we have referred to these films as bio-based redox capacitors (BBRC) [2,3,38,39].”
InfluentialAlzheimer, M., Svensson, S. L., König, F., Schweinlin, M., Metzger, M., Walles, H., & Sharma, C. M. (2020) · PLoS Pathogens · doi:10.1371/journal.ppat.1008304 · Cited by 33
“3125 μm reached nearly similar dimensions as measured for native human intestine and as previously reported [37,41].”
Novel Strategies in Artificial Organ Development: What Is the Future of Medicine?
Klak, M., Bryniarski, T., Kowalska, P. D., Gomółka, M., Tymicki, G., Kosowska, K., Cywoniuk, P., Dobrzański, T., Turowski, P., & Wszola, M. (2020) · Micromachines · doi:10.3390/mi11070646 · Cited by 36
He, Y., Mao, T., Gu, Y., Yang, Y., & Ding, J. (2020) · Biofabrication · doi:10.1088/1758-5090/abb295 · Cited by 32
Grassart, A., Malardé, V., Gobaa, S., Sartori-Rupp, A., Kerns, J., Karalis, K. P., Marteyn, B., Sansonetti, P. J., & Sauvonnet, N. (2019) · Cell Host & Microbe · doi:10.1016/j.chom.2019.09.007 · Cited by 35
Li, L., Wang, X., Hu, L., Chen, R., Huang, Y., Chen, S., Huang, W., Huo, K., & Chu, P. K.-H. (2012) · Lab on a Chip · doi:10.1039/c2lc40148g · Cited by 32
The Challenge of Imitating Nature
Nerem, R. M., & Schutte, S. C. (2013) · Elsevier eBooks · doi:10.1016/b978-0-12-398358-9.00002-1 · Cited by 41
In Vitro Models for Investigating Intestinal Host–Pathogen Interactions
McCoy, R. S. A., Oldroyd, S., Yang, W., Wang, K., Hoven, D., Bulmer, D. C., Zilbauer, M., & Owens, R. M. (2023) · Advanced Science · doi:10.1002/advs.202306727 · Cited by 36
Recapitulating the Tumor Ecosystem Along the Metastatic Cascade Using 3D Culture Models
Kim, J., & Tanner, K. (2015) · Frontiers in Oncology · doi:10.3389/fonc.2015.00170 · Cited by 31
Bajaj, P., Harris, J. F., Huang, J., Nath, P., & Iyer, R. S. (2016) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.5b00480 · Cited by 37
Ultrathin Polymer Membranes with Patterned, Micrometric Pores for Organs-on-Chips
Pensabene, V., Costa, L. A., Terekhov, A. Y., Gnecco, J. S., Wikswo, J. P., & Hofmeister, W. H. (2016) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.6b05754 · Cited by 30
Mucopenetrating micelles with a PEG corona
Taipaleenmäki, E. M., Mouritzen, S. A., Schattling, P. S., Zhang, Y., & Städler, B. (2017) · Nanoscale · doi:10.1039/c7nr06821b · Cited by 31
Mimicking the Human Physiology with Microphysiological Systems (MPS)
Sung, J. H., Koo, J., & Shuler, M. L. (2019) · BioChip Journal · doi:10.1007/s13206-019-3201-z · Cited by 33
Valencia, L., Canalejas-Tejero, V., Clemente, M., Fernaud, I., Holgado, M., Jorcano, J. L., & Velasco, D. (2021) · Scientific Reports · doi:10.1038/s41598-021-91875-z · Cited by 33
Current Perspectives on Gastrointestinal Models to Assess Probiotic-Pathogen Interactions
Anjum, M., Laitila, A., Ouwehand, A. C., & Forssten, S. D. (2022) · Frontiers in Microbiology · doi:10.3389/fmicb.2022.831455 · Cited by 38
Metadata
- Authors
- Kim, H. J., Huh, D., Hamilton, G., & Ingber, D. E.
- Affiliations
- Harvard University (US)
- Boston Children's Hospital (US)
- Corresponding author
- Ingber, Donald E.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2012
- Volume
- 12
- Issue
- 12
- Pages
- 2165
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2168752825
- Cited by
- 1,734
- References
- 65
- Citations by year
- 2026: 114 · 2025: 130 · 2024: 163 · 2023: 150 · 2022: 150 · 2021: 185 · 2020: 154 · 2019: 154 · 2018: 133 · 2017: 130 · 2016: 84 · 2015: 61 · 2014: 54 · 2013: 57 · 2012: 13
- FWCI
- 33.74
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Lab on a Chip (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Harvard University
- Hansjörg Wyss Institute for Biologically Inspired Engineering, Harvard University
- National Institute of Environmental Health Sciences (R01ES016665, ES016665-01A1)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Health Sciences › Medicine › Surgery › Tissue Engineering and Regenerative Medicine
- Keywords
- gut-on-a-chip, intestinal epithelium, Caco-2 cells, peristalsis, cyclic strain, microfluidics, extracellular matrix, Lactobacillus rhamnosus GG, intestinal barrier function, epithelial polarization, low shear stress, drug testing, alternatives to animal testing
- MeSH terms
- Aminopeptidases, beta-Galactosidase, Dimethylpolysiloxanes, Epithelial Cells, Humans, Intestines, Models, Biological, Caco-2 Cells, Tissue Engineering, Biomimetic Materials, Lacticaseibacillus rhamnosus, Metagenome
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.