Human gut-on-a-chip inhabited by microbial flora that experiences intestinal peristalsis-like motions and flow
The DOI matches its Crossref record; 65 of the 65 references it cites were found in a registry or an index.
Abstract
Development of an in vitro living cell-based model of the intestine that mimics the mechanical, structural, absorptive, transport and pathophysiological properties of the human gut along with its crucial microbial symbionts could accelerate pharmaceutical development, and potentially replace animal testing. Here, we describe a biomimetic 'human gut-on-a-chip' microdevice composed of two microfluidic channels separated by a porous flexible membrane coated with extracellular matrix (ECM) and lined by human intestinal epithelial (Caco-2) cells that mimics the complex structure and physiology of living intestine. The gut microenvironment is recreated by flowing fluid at a low rate (30 μL h(-1)) producing low shear stress (0.02 dyne cm(-2)) over the microchannels, and by exerting cyclic strain (10%; 0.15 Hz) that mimics physiological peristaltic motions. Under these conditions, a columnar epithelium develops that polarizes rapidly, spontaneously grows into folds that recapitulate the structure of intestinal villi, and forms a high integrity barrier to small molecules that better mimics whole intestine than cells in cultured in static Transwell models. In addition, a normal intestinal microbe (Lactobacillus rhamnosus GG) can be successfully co-cultured for extended periods (>1 week) on the luminal surface of the cultured epithelium without compromising epithelial cell viability, and this actually improves barrier function as previously observed in humans. Thus, this gut-on-a-chip recapitulates multiple dynamic physical and functional features of human intestine that are critical for its function within a controlled microfluidic environment that is amenable for transport, absorption, and toxicity studies, and hence it should have great value for drug testing as well as development of novel intestinal disease models.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“this 2-dimensional (2D) culture format fails to recapitulate physiological 3-dimensional (3D) intestinal cell and tissue morphology or re-establish other key intestinal differentiated functions (eg, mucus production, villi formation, cytochrome P-450-based drug metabolism).”
From Microfluidic Organ-on-a-Chip Models of Human Intestine (2018) · cites this paper as [16]
In the citing paper
“These conventional static models also cannot support the coculture of commensal microbiome with human intestinal cells, which are critical for gut physiology,16 because the bacteria rapidly overgrow and contaminate the human cell cultures within a day.”
From Microfluidic Organ-on-a-Chip Models of Human Intestine (2018) · cites this paper as [16]
In the citing paper
“In fact, barrier function was shown to increase when the intestinal epithelium was cocultured with L rhamnosus GG.16”
From Microfluidic Organ-on-a-Chip Models of Human Intestine (2018) · cites this paper as [16]
In the citing paper
“Importantly, because the Gut Chip has continuous fluid flow, villi formation, and mucus production, it is also possible to coculture living commensal microbes (eg, Lactobacillus rhamnosus GG)16 or the VSL#3 clinical probiotic formulation containing 8 different microbial strains42) in direct contact with the intestinal epithelial cells within the lumen of the parenchymal channel for weeks in vitro”
From Microfluidic Organ-on-a-Chip Models of Human Intestine (2018) · cites this paper as [16]
In the citing paper
“Importantly, the probiotic L rhamnosus GG was shown to increase intestinal barrier function when cocultured in the lumen of the intestinal epithelial channel of the human Gut Chip,16”
From Microfluidic Organ-on-a-Chip Models of Human Intestine (2018) · cites this paper as [16]
5 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Turnbaugh, P. J., Ley, R. E., Hamady, M., Fraser-Liggett, C. M., Knight, R., & Gordon, J. I. (2007) · Nature · doi:10.1038/nature06244 · Cited by 6,091
The gut microbiota shapes intestinal immune responses during health and disease
Round, J. L., & Mazmanian, S. K. (2009) · Nature Reviews Immunology · doi:10.1038/nri2515 · Cited by 5,029
Reconstituting organ-level lung functions on a chip
Huh, D., Matthews, B. D., Mammoto, A., Montoya-Zavala, M., Hsin, H. Y., & Ingber, D. E. (2010) · Science · doi:10.1126/science.1188302 · Cited by 4,250
Self-citationIntestinal mucosal barrier function in health and disease
Turner, J. R. (2009) · Nature reviews. Immunology · doi:10.1038/nri2653 · Cited by 3,952
Membrane transporters in drug development
The International Transporter Consortium, Giacomini, K. M., Huang, S.-M., Tweedie, D. J., Benet, L. Z., Brouwer, K. L. R., Chu, X., Dahlin, A., Evers, R., Fischer, V., et al. (2010) · Nature Reviews Drug Discovery · doi:10.1038/nrd3028 · Cited by 3,340
Occludin: a novel integral membrane protein localizing at tight junctions.
Furuse, M., Hirase, T., Itoh, M., Nagafuchi, A., Yonemura, S., Tsukita, S., & Tsukita, S. (1993) · The Journal of cell biology · doi:10.1083/jcb.123.6.1777 · Cited by 2,580
Hidalgo, I. J., Raub, T. J., & Borchardt, R. T. (1989) · Gastroenterology · doi:10.1016/s0016-5085(89)80072-1 · Cited by 2,396
Concordance of the toxicity of pharmaceuticals in humans and in animals
Olson, H., Betton, G., Robinson, D., Thomas, K., Monro, A., Kolaja, G., Lilly, P., Sanders, J., Sipes, G., Bracken, W., et al. (2000) · Regulatory Toxicology and Pharmacology · doi:10.1006/rtph.2000.1399 · Cited by 2,050
Determination of drug permeability and prediction of drug absorption in Caco-2 monolayers
Hubatsch, I., Ragnarsson, E. G. E., & Artursson, P. (2007) · Nature Protocols · doi:10.1038/nprot.2007.303 · Cited by 1,499
Yee, S. (1997) · Pharmaceutical Research · doi:10.1023/a:1012102522787 · Cited by 1,030
Research works printed but not linked: 3
- Ho, 1993, Cancer Res., 53, 641
- Dai, 2012, Int. J. Mol. Med, 29, 202
- Coconnier, 1993, FEMS Microbiol. Lett., 110, 299, 10.1111/j.1574-6968.1993.tb06339.x · doi:10.1111/j.1574-6968.1993.tb06339.x · Paper page
Cited by
Items 101–200 of 1,004
Jalili-Firoozinezhad, S., Prantil-Baun, R., Jiang, A., Potla, R., Mammoto, T., Weaver, J. C., Ferrante, T. C., Kim, H. J., Cabral, J. M. S., Levy, O., et al. (2018) · Cell Death & Disease · doi:10.1038/s41419-018-0304-8 · Cited by 209
Self-citationMeasuring direct current trans-epithelial electrical resistance in organ-on-a-chip microsystems
Odijk, M., van der Meer, A. D., Levner, D., Kim, H. J., van der Helm, M. W., Segerink, L. I., Frimat, J.-P., Hamilton, G. A., Ingber, D. E., & van den Berg, A. (2015) · Lab on a Chip · doi:10.1039/c4lc01219d · Cited by 209
Self-citationMarzorati, M., Vanhoecke, B., De Ryck, T., Sadaghian Sadabad, M., Pinheiro, I., Possemiers, S., Van den Abbeele, P., Derycke, L., Bracke, M., Pieters, J., et al. (2014) · BMC Microbiology · doi:10.1186/1471-2180-14-133 · Cited by 206
“The evaluation of the host’s response is normally conducted by means of cell culture experiments in plates [22], in a trans-well setup [23], by the three-dimensional organotypic model of human colonic epithelium [24] or using the so-called human gut-on-a-chip [25].”
Grassart, A., Malardé, V., Gobaa, S., Sartori-Rupp, A., Kerns, J., Karalis, K., Marteyn, B., Sansonetti, P., & Sauvonnet, N. (2019) · Cell Host & Microbe · doi:10.1016/j.chom.2019.08.007 · Cited by 206
“15Hz) to reproduce the peristaltic motions (Chaturvedi et al., 2008; Gayer and Basson, 2009; Kim et al., 2012; Womack et al., 1987).”
Microfluidic Organ‐on‐a‐Chip Technology for Advancement of Drug Development and Toxicology
Caplin, J. D., Granados, N. G., James, M. R., Montazami, R., & Hashemi, N. (2015) · Advanced Healthcare Materials · doi:10.1002/adhm.201500040 · Cited by 205
Hatton, G. B., Yadav, V., Basit, A. W., & Merchant, H. A. (2015) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.24365 · Cited by 204
In vitro micro-physiological immune-competent model of the human skin
Ramadan, Q., & Ting, F. C. W. (2016) · Lab on a Chip · doi:10.1039/c6lc00229c · Cited by 203
Maurer, M., Gresnigt, M. S., Last, A., Wollny, T., Berlinghof, F., Pospich, R., Cseresnyes, Z., Medyukhina, A., Graf, K., Gröger, M., et al. (2019) · Biomaterials · doi:10.1016/j.biomaterials.2019.119396 · Cited by 200
“…perfused model of the human intestine has been described that allows circulation of peripheral blood mononuclear cells (PBMCs) and effectively recapitulates structural features of intestinal microanatomy and physiology, including a polarised intestinal tissue differentiation [10,11].”
InfluentialHuman Gut-On-A-Chip Supports Polarized Infection of Coxsackie B1 Virus In Vitro
Villenave, R., Wales, S. Q., Hamkins-Indik, T., Papafragkou, E., Weaver, J. C., Ferrante, T. C., Bahinski, A., Elkins, C. A., Kulka, M., & Ingber, D. E. (2017) · PLOS ONE · doi:10.1371/journal.pone.0169412 · Cited by 197
“To begin to address this pressing need for new in vitro models of enteric virus infection, we investigated whether a recently developed human Gut-on-a-Chip microfluidic device that permits culture of human intestinal epithelium under conditions that mimic the physical microenvironment of human intestine, including phy…”
InfluentialSelf-citationMicrofluidics Expanding the Frontiers of Microbial Ecology
Rusconi, R., Garren, M., & Stocker, R. (2014) · Annual Review of Biophysics · doi:10.1146/annurev-biophys-051013-022916 · Cited by 198
“Figure modified from Kim et al. (2012b) with permission. b) Schematic drawing of the microfluidic device used to co-culture three species of soil bacteria by imposing spatial structure on three culture wells and providing a chemical communication channel.”
Emerging Technologies for Gut Microbiome Research
Arnold, J. W., Roach, J., & Azcarate-Peril, M. A. (2016) · Trends in Microbiology · doi:10.1016/j.tim.2016.06.008 · Cited by 198
“It is now possible to construct in vitro systems that simulate intra-organ micro ecosystems, permitting high-throughput microbiome studies by engineering microfluidic devices that can be seeded with cultured host cells [70].”
Engineering stem cell-derived 3D brain organoids in a perfusable organ-on-a-chip system
Wang, Y., Wang, L., Guo, Y., Zhu, Y., & Qin, J. (2018) · RSC Advances · doi:10.1039/c7ra11714k · Cited by 197
Lung-on-a-chip: the future of respiratory disease models and pharmacological studies
Shrestha, J., Razavi Bazaz, S., Aboulkheyr Es, H., Yaghobian Azari, D., Thierry, B., Ebrahimi Warkiani, M., & Ghadiri, M. (2020) · Critical Reviews in Biotechnology · doi:10.1080/07388551.2019.1710458 · Cited by 195
Synthetic ecology of the human gut microbiota
Vrancken, G., Gregory, A. C., Huys, G. R. B., Faust, K., & Raes, J. (2019) · Nature Reviews Microbiology · doi:10.1038/s41579-019-0264-8 · Cited by 193
3D Printing of Organs-On-Chips
Yi, H.-G., Lee, H., & Cho, D.-W. (2017) · Bioengineering · doi:10.3390/bioengineering4010010 · Cited by 193
“as intestinal tissue [7], blood–brain barrier [2], and bone marrow [8].”
Medium throughput breathing human primary cell alveolus-on-chip model
Stucki, J. D., Hobi, N., Galimov, A., Stucki, A. O., Schneider-Daum, N., Lehr, C.-M., Huwer, H., Frick, M., Funke-Chambour, M., Geiser, T., et al. (2018) · Scientific Reports · doi:10.1038/s41598-018-32523-x · Cited by 190
Advances and Current Challenges in Intestinal in vitro Model Engineering: A Digest
Costa, J., & Ahluwalia, A. (2019) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2019.00144 · Cited by 193
“Interestingly, the presence of flow consistently accelerates Caco-2 differentiation and barrier formation (Kim et al., 2012; Giusti et al., 2014; Cacopardo et al., 2019).”
InfluentialIntegrating organoids and organ-on-a-chip devices
Zhao, Y., Landau, S., Okhovatian, S., Liu, C., Lu, R. X. Z., Lai, B. F. L., Wu, Q., Kieda, J., Cheung, K., Rajasekar, S., et al. (2024) · Nature Reviews Bioengineering · doi:10.1038/s44222-024-00207-z · Cited by 185
“These aspects have been captured by OoC technology 55 .”
A modular approach to create a neurovascular unit-on-a-chip
Achyuta, A. K. H., Conway, A. J., Crouse, R. B., Bannister, E. C., Lee, R. N., Katnik, C. P., Behensky, A. A., Cuevas, J., & Sundaram, S. S. (2013) · Lab Chip · doi:10.1039/c2lc41033h · Cited by 191
Microfluidic 3D models of cancer
Sung, K. E., & Beebe, D. J. (2014) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2014.07.002 · Cited by 190
Microfluidic Gut-liver chip for reproducing the first pass metabolism
Choe, A., Ha, S. K., Choi, I., Choi, N., & Sung, J. H. (2017) · Biomedical Microdevices · doi:10.1007/s10544-016-0143-2 · Cited by 189
“It has been reported that combination of fluidic shear and strain resulted in villi-like structure of Caco-2 cells (Kim et al. 2012).”
InfluentialShin, W., Wu, A., Massidda, M. W., Foster, C., Thomas, N., Lee, D.-W., Koh, H., Ju, Y., Kim, J., & Kim, H. J. (2019) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2019.00013 · Cited by 190
Self-citationMicrofluidic titer plate for stratified 3D cell culture
Trietsch, S. J., Israëls, G. D., Joore, J., Hankemeier, T., & Vulto, P. (2013) · Lab on a Chip · doi:10.1039/c3lc50210d · Cited by 189
From cardiac tissue engineering to heart-on-a-chip: beating challenges
Zhang, Y. S., Aleman, J., Arneri, A., Bersini, S., Piraino, F., Shin, S. R., Dokmeci, M. R., & Khademhosseini, A. (2015) · Biomedical Materials · doi:10.1088/1748-6041/10/3/034006 · Cited by 189
Simulating human digestion: developing our knowledge to create healthier and more sustainable foods
Mackie, A., Mulet-Cabero, A.-I., & Torcello-Gómez, A. (2020) · Food & Function · doi:10.1039/d0fo01981j · Cited by 187
Shin, W., & Kim, H. J. (2022) · Nature Protocols · doi:10.1038/s41596-021-00674-3 · Cited by 185
Self-citationShin, W., Hinojosa, C. D., Ingber, D. E., & Kim, H. J. (2019) · iScience · doi:10.1016/j.isci.2019.04.037 · Cited by 186
Self-citationRobust bioengineered 3D functional human intestinal epithelium
Chen, Y., Lin, Y., Davis, K. M., Wang, Q., Rnjak-Kovacina, J., Li, C., Isberg, R. R., Kumamoto, C. A., Mecsas, J., & Kaplan, D. L. (2015) · Scientific Reports · doi:10.1038/srep13708 · Cited by 185
Wang, Y., Kim, R., Gunasekara, D. B., Reed, M. I., DiSalvo, M., Nguyen, D. L., Bultman, S. J., Sims, C. E., Magness, S. T., & Allbritton, N. L. (2018) · Cellular and Molecular Gastroenterology and Hepatology · doi:10.1016/j.jcmgh.2017.10.007 · Cited by 185
Development of a Gut-on-a-Chip Model for High Throughput Disease Modeling and Drug Discovery
Beaurivage, C., Naumovska, E., Chang, Y., Elstak, E., Nicolas, A., Wouters, H., van Moolenbroek, G., Lanz, H., Trietsch, S., Joore, J., et al. (2019) · International Journal of Molecular Sciences · doi:10.3390/ijms20225661 · Cited by 185
von Martels, J. Z. H., Sadaghian Sadabad, M., Bourgonje, A. R., Blokzijl, T., Dijkstra, G., Faber, K. N., & Harmsen, H. J. M. (2017) · Anaerobe · doi:10.1016/j.anaerobe.2017.01.001 · Cited by 184
High-Throughput Methods in the Discovery and Study of Biomaterials and Materiobiology
Yang, L., Pijuan-Galito, S., Rho, H. S., Vasilevich, A. S., Eren, A. D., Ge, L., Habibović, P., Alexander, M. R., de Boer, J., Carlier, A., et al. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c00752 · Cited by 180
Microfluidic Organ-on-A-chip: A Guide to Biomaterial Choice and Fabrication
Cao, U. M. N., Zhang, Y., Chen, J., Sayson, D., Pillai, S., & Tran, S. D. (2023) · International Journal of Molecular Sciences · doi:10.3390/ijms24043232 · Cited by 178
“, Matrigel) to promote monolayer intestinal cell attachment and model the epithelial layer of the gut [81].”
Zooming in to see the bigger picture: Microfluidic and nanofabrication tools to study bacteria
Hol, F. J. H., & Dekker, C. (2014) · Science · doi:10.1126/science.1251821 · Cited by 180
“Studies such as (93, 95, 96) are examples of the move toward laboratory experiments that strive to be a realistic representation of the natural environment while retaining a high degree of experimental control and permitting visualization at high spatiotemporal resolution.”
Integrating biological vasculature into a multi-organ-chip microsystem
Schimek, K., Busek, M., Brincker, S., Groth, B., Hoffmann, S., Lauster, R., Lindner, G., Lorenz, A., Menzel, U., Sonntag, F., et al. (2013) · Lab on a Chip · doi:10.1039/c3lc50217a · Cited by 180
Electroosmosis-modulated peristaltic transport in microfluidic channels
Bandopadhyay, A., Tripathi, D., & Chakraborty, S. (2016) · Physics of Fluids · doi:10.1063/1.4947115 · Cited by 176
Human enteroids as an ex-vivo model of host–pathogen interactions in the gastrointestinal tract
Foulke-Abel, J., In, J., Kovbasnjuk, O., Zachos, N. C., Ettayebi, K., Blutt, S. E., Hyser, J. M., Zeng, X.-L., Crawford, S. E., Broughman, J. R., et al. (2014) · Experimental Biology and Medicine · doi:10.1177/1535370214529398 · Cited by 179
“However, the effects of a first generation microfluidic ‘‘gut-on-a-chip’’ technology that combines peristalsis-like stretch with apical and basolateral liquid flow has been reported recently using Caco-2 cells.(46) The presence of both stretch and flow in the microfluidic system allowed Caco-2 cells to differentiate,…”
A versatile lab-on-a-chip tool for modeling biological barriers
Walter, F. R., Valkai, S., Kincses, A., Petneházi, A., Czeller, T., Veszelka, S., Ormos, P., Deli, M. A., & Dér, A. (2016) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2015.07.110 · Cited by 177
Xu, Y., Shrestha, N., Préat, V., & Beloqui, A. (2021) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2021.05.005 · Cited by 176
Organs-on-chips technologies – A guide from disease models to opportunities for drug development
Monteduro, A. G., Rizzato, S., Caragnano, G., Trapani, A., Giannelli, G., & Maruccio, G. (2023) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2023.115271 · Cited by 175
Experimental models to study intestinal microbes–mucus interactions in health and disease
Etienne-Mesmin, L., Chassaing, B., Desvaux, M., De Paepe, K., Gresse, R., Sauvaitre, T., Forano, E., de Wiele, T. V., Schüller, S., Juge, N., et al. (2019) · FEMS Microbiology Reviews · doi:10.1093/femsre/fuz013 · Cited by 178
Prantil-Baun, R., Novak, R., Das, D., Somayaji, M. R., Przekwas, A., & Ingber, D. E. (2018) · Annual Review of Pharmacology and Toxicology · doi:10.1146/annurev-pharmtox-010716-104748 · Cited by 176
Self-citationAn organoid-based organ-repurposing approach to treat short bowel syndrome
Sugimoto, S., Kobayashi, E., Fujii, M., Ohta, Y., Arai, K., Matano, M., Ishikawa, K., Miyamoto, K., Toshimitsu, K., Takahashi, S., et al. (2021) · Nature · doi:10.1038/s41586-021-03247-2 · Cited by 175
From meta-omics to causality: experimental models for human microbiome research
Fritz, J. V., Desai, M. S., Shah, P., Schneider, J. G., & Wilmes, P. (2013) · Microbiome · doi:10.1186/2049-2618-1-14 · Cited by 174
“Therefore, it can be regarded as an essential research tool for drug testing [44].”
InfluentialToward a Predictive Understanding of Earth’s Microbiomes to Address 21st Century Challenges
Blaser, M. J., Cardon, Z. G., Cho, M. K., Dangl, J. L., Donohue, T. J., Green, J. L., Knight, R., Maxon, M. E., Northen, T. R., Pollard, K. S., et al. (2016) · mBio · doi:10.1128/mbio.00714-16 · Cited by 172
Development of a human primary gut-on-a-chip to model inflammatory processes
Beaurivage, C., Kanapeckaite, A., Loomans, C., Erdmann, K. S., Stallen, J., & Janssen, R. A. J. (2020) · Scientific Reports · doi:10.1038/s41598-020-78359-2 · Cited by 171
Aralekallu, S., Boddula, R., & Singh, V. (2023) · Materials & Design · doi:10.1016/j.matdes.2022.111517 · Cited by 168
High-throughput organ-on-a-chip systems: Current status and remaining challenges
Probst, C., Schneider, S., & Loskill, P. (2018) · Current Opinion in Biomedical Engineering · doi:10.1016/j.cobme.2018.02.004 · Cited by 171
Delon, L. C., Guo, Z., Oszmiana, A., Chien, C.-C., Gibson, R., Prestidge, C., & Thierry, B. (2019) · Biomaterials · doi:10.1016/j.biomaterials.2019.119521 · Cited by 171
Effect of flow and peristaltic mixing on bacterial growth in a gut-like channel
Cremer, J., Segota, I., Yang, C.-Y., Arnoldini, M., Sauls, J. T., Zhang, Z., Gutierrez, E., Groisman, A., & Hwa, T. (2016) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1601306113 · Cited by 167
Yuan, L., van der Mei, H. C., Busscher, H. J., & Peterson, B. W. (2020) · Frontiers in Microbiology · doi:10.3389/fmicb.2020.599555 · Cited by 165
“This is a common observation in vitro, both for probiotic bacteria (Kim et al., 2012) as well as for pathogenic strains (Hasan et al., 2018).”
Skeletal muscle-on-a-chip: an in vitro model to evaluate tissue formation and injury
Agrawal, G., Aung, A., & Varghese, S. (2017) · Lab on a Chip · doi:10.1039/c7lc00512a · Cited by 163
Use of porous membranes in tissue barrier and co-culture models
Chung, H. H., Mireles, M., Kwarta, B. J., & Gaborski, T. R. (2018) · Lab on a Chip · doi:10.1039/c7lc01248a · Cited by 161
Bichet, M. C., Chin, W. H., Richards, W., Lin, Y.-W., Avellaneda-Franco, L., Hernandez, C. A., Oddo, A., Chernyavskiy, O., Hilsenstein, V., Neild, A., et al. (2021) · iScience · doi:10.1016/j.isci.2021.102287 · Cited by 162
Xu, H., Zhang, Y., Wang, P., Zhang, J., Chen, H., Zhang, L., Du, X., Zhao, C., Wu, D., Liu, F., et al. (2021) · Acta Pharmaceutica Sinica B · doi:10.1016/j.apsb.2021.03.024 · Cited by 162
Synthetic small intestinal scaffolds for improved studies of intestinal differentiation
Costello, C. M., Hongpeng, J., Shaffiey, S., Yu, J., Jain, N. K., Hackam, D., & March, J. C. (2014) · Biotechnology and Bioengineering · doi:10.1002/bit.25180 · Cited by 162
“Similarly, on-chip peristaltic devices have been created that enable separation of basolateral and apical membranes for more accurate intestinal transport and absorption studies, as well as co-culture with bacteria (Kim et al., 2012).”
van der Helm, M. W., Henry, O. Y. F., Bein, A., Hamkins-Indik, T., Cronce, M. J., Leineweber, W. D., Odijk, M., van der Meer, A. D., Eijkel, J. C. T., Ingber, D. E., et al. (2019) · Lab on a Chip · doi:10.1039/c8lc00129d · Cited by 161
Self-citationCreff, J., Courson, R., Mangeat, T., Foncy, J., Souleille, S., Thibault, C., Besson, A., & Malaquin, L. (2019) · Biomaterials · doi:10.1016/j.biomaterials.2019.119404 · Cited by 161
Current understanding of the gut microbiota shaping mechanisms
Chang, C.-S., & Kao, C.-Y. (2019) · Journal of Biomedical Science · doi:10.1186/s12929-019-0554-5 · Cited by 161
Barrila, J., Crabbé, A., Yang, J., Franco, K., Nydam, S. D., Forsyth, R. J., Davis, R. R., Gangaraju, S., Ott, C. M., Coyne, C. B., et al. (2018) · Infection and Immunity · doi:10.1128/iai.00282-18 · Cited by 154
“thelial cell types (absorptive, goblet, enteroendocrine, and Paneth cells) (340, 341).”
One-Stop Microfluidic Assembly of Human Brain Organoids To Model Prenatal Cannabis Exposure
Ao, Z., Cai, H., Havert, D. J., Wu, Z., Gong, Z., Beggs, J. M., Mackie, K., & Guo, F. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.0c00205 · Cited by 154
Emergence of microfluidics for next generation biomedical devices
Preetam, S., Nahak, B. K., Patra, S., Toncu, D. C., Park, S., Syväjärvi, M., Orive, G., & Tiwari, A. (2022) · Biosensors and Bioelectronics X · doi:10.1016/j.biosx.2022.100106 · Cited by 228
Mechanical Stimulation: A Crucial Element of Organ-on-Chip Models
Thompson, C. L., Fu, S., Heywood, H. K., Knight, M. M., & Thorpe, S. D. (2020) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2020.602646 · Cited by 178
“This platform can support the coculture of intestinal microbes for extended periods without compromising epithelial viability (Kim et al., 2012).”
Zhang, R., & Larsen, N. B. (2017) · Lab on a Chip · doi:10.1039/c7lc00926g · Cited by 154
Madden, L. R., Nguyen, T. V., Garcia-Mojica, S., Shah, V., Le, A. V., Peier, A., Visconti, R., Parker, E. M., Presnell, S. C., Nguyen, D. G., et al. (2018) · iScience · doi:10.1016/j.isci.2018.03.015 · Cited by 153
“…and more recent gut-on-a-chip systems commonly include cell lines originating from colorectal and duodenal tumor tissue (Alqahtani et al., 2013; Kim et al., 2012) that may exhibit altered metabolic profiles and expression patterns of xenobiotic-metabolizing enzymes and transporters potentially…”
Ferrari, E., Palma, C., Vesentini, S., Occhetta, P., & Rasponi, M. (2020) · Biosensors · doi:10.3390/bios10090110 · Cited by 172
Vaginal microbiome-host interactions modeled in a human vagina-on-a-chip
Mahajan, G., Doherty, E. R., To, T., Sutherland, A. D., Grant, J. L., Junaid, A., Gulati, A., LoGrande, N., Izadifar, Z., Timilsina, S. S., et al. (2022) · Microbiome · doi:10.1186/s40168-022-01400-1 · Cited by 169
Self-citationPhysiologically relevant organs on chips
Yum, K., Hong, S. G., Healy, K. E., & Lee, L. P. (2014) · Biotechnology Journal · doi:10.1002/biot.201300187 · Cited by 150
“Other microengineered physiological systems have also been developed to build heart [32, 50], muscle [51], brain [75, 76, 78, 79, 90–92], gut [93, 94], pancreatic islet [95], eye [77], tumor [34, 96] models.”
Microfluidic Organ/Body-on-a-Chip Devices at the Convergence of Biology and Microengineering
Perestrelo, A., Águas, A., Rainer, A., & Forte, G. (2015) · Sensors · doi:10.3390/s151229848 · Cited by 149
Direct quantification of transendothelial electrical resistance in organs-on-chips
van der Helm, M. W., Odijk, M., Frimat, J., van der Meer, A. D., Eijkel, J. C. T., van den Berg, A., & Segerink, L. I. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.06.014 · Cited by 156
Design and fabrication of a scalable liver-lobule-on-a-chip microphysiological platform
Banaeiyan, A. A., Theobald, J., Paukštyte, J., Wölfl, S., Adiels, C. B., & Goksör, M. (2017) · Biofabrication · doi:10.1088/1758-5090/9/1/015014 · Cited by 149
“Green fluorescent signals from calcein AMsignifies live cells and red signals fromEthD-1 shows dead cells. et al 2010, Kim et al 2012, Jang et al 2013, Trietsch et al 2013, YoonáNo 2013, Maschmeyer et al 2015) indicates the drive towards novel approaches to reproduce the native niche of human…”
Mammoto, A., Mammoto, T., Kanapathipillai, M., Yung, C. W., Jiang, E., Jiang, A. R., Lofgren, K. A., Gee, E. P. S., & Ingber, D. E. (2013) · Nature Communications · doi:10.1038/ncomms2774 · Cited by 162
Self-citationAmirifar, L., Shamloo, A., Nasiri, R., de Barros, N. R., Wang, Z. Z., Unluturk, B. D., Libanori, A., Ievglevskyi, O., Diltemiz, S. E., Sances, S., et al. (2022) · Biomaterials · doi:10.1016/j.biomaterials.2022.121531 · Cited by 147
A Comprehensive Review of Organ-on-a-Chip Technology and Its Applications
Doost, N. F., & Srivastava, S. K. (2024) · Biosensors · doi:10.3390/bios14050225 · Cited by 187
“Kim et al. [44] created an intestine-on-a-chip by constructing a chamber bilayer separated by a porous membrane lined with gut epithelium cells, as seen in Figure 5.”
Shao, Y., & Fu, J. (2013) · Advanced Materials · doi:10.1002/adma.201304431 · Cited by 166
Material approaches to active tissue mechanics
Xi, W., Saw, T. B., Delacour, D., Lim, C. T., & Ladoux, B. (2018) · Nature Reviews Materials · doi:10.1038/s41578-018-0066-z · Cited by 162
Review: in vitro microvessel models
Bogorad, M. I., DeStefano, J., Karlsson, J., Wong, A. D., Gerecht, S., & Searson, P. C. (2015) · Lab on a Chip · doi:10.1039/c5lc00832h · Cited by 145
Gordon, S. (2015) · ALTEX · doi:10.14573/altex.1510051 · Cited by 144
“…within micro-fluidic channels of a clear, flexible, polydimethylsiloxane (PDMS) device created with microchip manufacturing that permits application of fluid flow as well as cyclic mechanical strain at levels similar to those experienced by epithelial cells in living intestine (Kim et al., 2012).”
Flow-induced stress on adherent cells in microfluidic devices
Shemesh, J., Jalilian, I., Shi, A., Heng Yeoh, G., Knothe Tate, M. L., & Ebrahimi Warkiani, M. (2015) · Lab on a Chip · doi:10.1039/c5lc00633c · Cited by 144
Young, E. W. K. (2013) · Integrative Biology · doi:10.1039/c3ib40076j · Cited by 143
Online oxygen monitoring using integrated inkjet-printed sensors in a liver-on-a-chip system
Moya, A., Ortega-Ribera, M., Guimerà, X., Sowade, E., Zea, M., Illa, X., Ramon, E., Villa, R., Gracia-Sancho, J., & Gabriel, G. (2018) · Lab on a Chip · doi:10.1039/c8lc00456k · Cited by 141
Watterson, W. J., Tanyeri, M., Watson, A. R., Cham, C. M., Shan, Y., Chang, E. B., Eren, A. M., & Tay, S. (2020) · eLife · doi:10.7554/elife.56998 · Cited by 175
A multi-chamber microfluidic intestinal barrier model using Caco-2 cells for drug transport studies
Tan, H.-Y., Trier, S., Rahbek, U. L., Dufva, M., Kutter, J. P., & Andresen, T. L. (2018) · PLOS ONE · doi:10.1371/journal.pone.0197101 · Cited by 143
Recurrent Urinary Tract Infection: A Mystery in Search of Better Model Systems
Murray, B. O., Flores, C., Williams, C., Flusberg, D. A., Marr, E. E., Kwiatkowska, K. M., Charest, J. L., Isenberg, B. C., & Rohn, J. L. (2021) · Frontiers in Cellular and Infection Microbiology · doi:10.3389/fcimb.2021.691210 · Cited by 183
“…(Shin et al., 2004), pulmonary thrombosis (Jain et al., 2018), tumor-vascular invasion (Nguyen et al., 2019), blood-brain barrier (Booth and Kim, 2012), nerve injury (Park et al., 2013; Tsantoulas et al., 2013) and neuronal networks (Shi et al., 2013; Xiao et al., 2013; van de Wijdeven et…”
Lefebvre, D. E., Venema, K., Gombau, L., Valerio, L. G., Raju, J., Bondy, G. S., Bouwmeester, H., Singh, R. P., Clippinger, A. J., Collnot, E.-M., et al. (2014) · Nanotoxicology · doi:10.3109/17435390.2014.948091 · Cited by 153
“For example, a recently developed in vitro/in silico hybrid model, termed gut-on-a-chip, uses two fluidic channels separated by a Caco-2 monolayer, and is engineered with microcircuitry to detect absorption of substances (Kim & Ingber, 2013; Kim et al., 2012; Vergeres et al., 2012).”
Drug Toxicity Evaluation Based on Organ-on-a-chip Technology: A Review
Cong, Y., Han, X., Wang, Y., Chen, Z., Lu, Y., Liu, T., Wu, Z., Jin, Y., Luo, Y., & Zhang, X. (2020) · Micromachines · doi:10.3390/mi11040381 · Cited by 140
Tissue chips – innovative tools for drug development and disease modeling
Low, L. A., & Tagle, D. A. (2017) · Lab on a Chip · doi:10.1039/c7lc00462a · Cited by 140
In vitro and ex vivo systems at the forefront of infection modeling and drug discovery
Shi, D., Mi, G., Wang, M., & Webster, T. J. (2018) · Biomaterials · doi:10.1016/j.biomaterials.2018.10.030 · Cited by 158
“demonstrated another microfluidic device, the “gut-on-a-chip” [174].”
Skin-on-a-chip models: General overview and future perspectives
Risueño, I., Valencia, L., Jorcano, J. L., & Velasco, D. (2021) · APL Bioengineering · doi:10.1063/5.0046376 · Cited by 137
Bioengineering approaches to guide stem cell-based organogenesis
Gjorevski, N., Ranga, A., & Lutolf, M. P. (2014) · Development · doi:10.1242/dev.101048 · Cited by 137
“Miniaturized and reductionist models of several organs, including the lung (Huh et al., 2010), the liver (Nakao et al., 2011), the kidney (Jang and Suh, 2010) and the gut (Kim et al., 2012), have thus far been created.”
Harnessing Mechanobiology for Tissue Engineering
Kim, S., Uroz, M., Bays, J., & Chen, C. S. (2021) · Developmental Cell · doi:10.1016/j.devcel.2020.12.017 · Cited by 149
“However, the effects of flow-induced shear are not limited to vascular physiology, as it also influences epithelial monolayer integrity, polarity, multicellular organization and function, as demonstrated in kidney proximal tubule, intestinal epithelial cells (Figure 1E) (Jang et al., 2013; Kim et al., 2012) and lung a…”
Gao, D., Liu, H., Lin, J.-M., Wang, Y., & Jiang, Y. (2013) · Lab on a Chip · doi:10.1039/c2lc41215b · Cited by 135
On being the right size: scaling effects in designing a human-on-a-chip
Moraes, C., Labuz, J. M., Leung, B. M., Inoue, M., Chun, T.-H., & Takayama, S. (2013) · Integrative Biology · doi:10.1039/c3ib40040a · Cited by 134
Primary Cell-Derived Intestinal Models: Recapitulating Physiology
Dutton, J. S., Hinman, S. S., Kim, R., Wang, Y., & Allbritton, N. L. (2018) · Trends in biotechnology · doi:10.1016/j.tibtech.2018.12.001 · Cited by 150
Zhang, J., Huang, Y.-J., Yoon, J. Y., Kemmitt, J., Wright, C. W., Schneider, K., Sphabmixay, P., Hernandez‐Gordillo, V., Holcomb, S. J., Bhushan, B. M., et al. (2020) · Med · doi:10.1016/j.medj.2020.07.001 · Cited by 146
Simulating drug concentrations in PDMS microfluidic organ chips
Grant, J., Özkan, A., Oh, C., Mahajan, G., Prantil-Baun, R., & Ingber, D. E. (2021) · Lab on a Chip · doi:10.1039/d1lc00348h · Cited by 133
Self-citationThe microbiota and autoimmunity: Their role in thyroid autoimmune diseases
Köhling, H.-L., Plummer, S. F., Marchesi, J. R., Davidge, K. S., & Ludgate, M. (2017) · Clinical Immunology · doi:10.1016/j.clim.2017.07.001 · Cited by 155
“More recent developments for intestinal models include the 417 Host-Microbiota Interaction module for long-term incubation [176] and the “gut-on-a418 chip” [177].”
Rusconi, R., & Stocker, R. (2015) · Current Opinion in Microbiology · doi:10.1016/j.mib.2015.03.003 · Cited by 132
“Bacteria belonging to the microbiome of humans and other animals experience flow in multiple regions of the body, including the intestine, stomach, urinary tract, mouth, and lungs [5,6].”
Clear castable polyurethane elastomer for fabrication of microfluidic devices
Domansky, K., Leslie, D. C., McKinney, J., Fraser, J. P., Sliz, J. D., Hamkins-Indik, T., Hamilton, G. A., Bahinski, A., & Ingber, D. E. (2013) · Lab on a Chip · doi:10.1039/c3lc50558h · Cited by 129
Self-citationComparison of conventional and advanced in vitro models in the toxicity testing of nanoparticles
Fröhlich, E. (2018) · Artificial Cells Nanomedicine and Biotechnology · doi:10.1080/21691401.2018.1479709 · Cited by 146
“In general, TEER values correlate with permeability of small molecules, but peristalsis in combination with flow increased drug permeability across Caco-2 monolayers leaving TEER values unchanged [12].”
Metadata
- Authors
- Kim, H. J., Huh, D., Hamilton, G., & Ingber, D. E.
- Affiliations
- Harvard University (US)
- Boston Children's Hospital (US)
- Corresponding author
- Ingber, Donald E.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2012
- Volume
- 12
- Issue
- 12
- Pages
- 2165
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2168752825
- Cited by
- 1,734
- References
- 65
- Citations by year
- 2026: 114 · 2025: 130 · 2024: 163 · 2023: 150 · 2022: 150 · 2021: 185 · 2020: 154 · 2019: 154 · 2018: 133 · 2017: 130 · 2016: 84 · 2015: 61 · 2014: 54 · 2013: 57 · 2012: 13
- FWCI
- 33.74
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Lab on a Chip (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Harvard University
- Hansjörg Wyss Institute for Biologically Inspired Engineering, Harvard University
- National Institute of Environmental Health Sciences (R01ES016665, ES016665-01A1)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Health Sciences › Medicine › Surgery › Tissue Engineering and Regenerative Medicine
- Keywords
- gut-on-a-chip, intestinal epithelium, Caco-2 cells, peristalsis, cyclic strain, microfluidics, extracellular matrix, Lactobacillus rhamnosus GG, intestinal barrier function, epithelial polarization, low shear stress, drug testing, alternatives to animal testing
- MeSH terms
- Aminopeptidases, beta-Galactosidase, Dimethylpolysiloxanes, Epithelial Cells, Humans, Intestines, Models, Biological, Caco-2 Cells, Tissue Engineering, Biomimetic Materials, Lacticaseibacillus rhamnosus, Metagenome
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.