Hepatic organoids for microfluidic drug screening
The DOI matches its Crossref record; 51 of the 51 references it cites were found in a registry or an index.
Abstract
We introduce the microfluidic organoids for drug screening (MODS) platform, a digital microfluidic system that is capable of generating arrays of individually addressable, free-floating, three-dimensional hydrogel-based microtissues (or 'organoids'). Here, we focused on liver organoids, driven by the need for early-stage screening methods for hepatotoxicity that enable a "fail early, fail cheaply" strategy in drug discovery. We demonstrate that arrays of hepatic organoids can be formed from co-cultures of HepG2 and NIH-3T3 cells embedded in hydrogel matrices. The organoids exhibit fibroblast-dependent contractile behaviour, and their albumin secretion profiles and cytochrome P450 3A4 activities are better mimics of in vivo liver tissue than comparable two-dimensional cell culture systems. As proof of principle for screening, MODS was used to generate and analyze the effects of a dilution series of acetaminophen on apoptosis and necrosis. With further development, we propose that the MODS platform may be a cost-effective tool in a "fail early, fail cheaply" paradigm of drug development.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
How to improve R&D productivity: the pharmaceutical industry's grand challenge
Paul, S. M., Mytelka, D. S., Dunwiddie, C. T., Persinger, C. C., Munos, B. H., Lindborg, S. R., & Schacht, A. L. (2010) · Nature Reviews Drug Discovery · doi:10.1038/nrd3078 · Cited by 3,566
Principles of early drug discovery
Hughes, J., Rees, S., Kalindjian, S., & Philpott, K. (2011) · British Journal of Pharmacology · doi:10.1111/j.1476-5381.2010.01127.x · Cited by 2,859
Hydrogels as extracellular matrix mimics for 3D cell culture
Tibbitt, M. W., & Anseth, K. S. (2009) · Biotechnology and Bioengineering · doi:10.1002/bit.22361 · Cited by 2,727
Ostapowicz, G., Fontana, R. J., Schiødt, F. V., Larson, A., Davern, T. J., Han, S. H. B., McCashland, T. M., Shakil, A. O., Hay, J. E., Hynan, L., et al. (2002) · Annals of Internal Medicine · doi:10.7326/0003-4819-137-12-200212170-00007 · Cited by 2,227
The role of matrix stiffness in regulating cell behavior†
Wells, R. G. (2008) · Hepatology · doi:10.1002/hep.22193 · Cited by 1,059
The Human Hepatic Cytochromes P450 Involved in Drug Metabolism
Wrighton, S. A., & Stevens, J. C. (1992) · Critical Reviews in Toxicology · doi:10.3109/10408449209145319 · Cited by 944
Inhibition and Induction of Cytochrome P450 and the Clinical Implications
Lin, J. H., & Lu, A. Y. H. (1998) · Clinical Pharmacokinetics · doi:10.2165/00003088-199835050-00003 · Cited by 829
Gerets, H. H. J., Tilmant, K., Gerin, B., Chanteux, H., Depelchin, B. O., Dhalluin, S., & Atienzar, F. A. (2012) · Cell Biology and Toxicology · doi:10.1007/s10565-011-9208-4 · Cited by 698
Fabrication of 3D hepatic tissues by additive photopatterning of cellular hydrogels
Tsang, V. L., Chen, A. A., Cho, L. M., Jadin, K. D., Sah, R. L., DeLong, S., West, J. L., & Bhatia, S. N. (2007) · The FASEB Journal · doi:10.1096/fj.06-7117com · Cited by 462
A microfluidic 3D hepatocyte chip for drug toxicity testing
Toh, Y.-C., Lim, T. C., Tai, D., Xiao, G., van Noort, D., & Yu, H. (2009) · Lab on a Chip · doi:10.1039/b900912d · Cited by 419
Micromechanical control of cell–cell interactions
Hui, E. E., & Bhatia, S. N. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0608660104 · Cited by 390
Vascularized organoid engineered by modular assembly enables blood perfusion
McGuigan, A. P., & Sefton, M. V. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0602740103 · Cited by 372
Self-citationZhang, C., Zhao, Z., Abdul Rahim, N. A., van Noort, D., & Yu, H. (2009) · Lab on a Chip · doi:10.1039/b915147h · Cited by 340
Digital microfluidics for cell-based assays
Barbulovic-Nad, I., Yang, H., Park, P. S., & Wheeler, A. R. (2008) · Lab on a Chip · doi:10.1039/b717759c · Cited by 337
Self-citationPutting Electrowetting to Work
Wheeler, A. R. (2008) · Science · doi:10.1126/science.1165719 · Cited by 315
Self-citationChang, T. T., & Hughes-Fulford, M. (2009) · Tissue Engineering Part A · doi:10.1089/ten.tea.2007.0434 · Cited by 311
Development of a Microscale Cell Culture Analog To Probe Naphthalene Toxicity
Viravaidya, K., Sin, A., & Shuler, M. L. (2008) · Biotechnology Progress · doi:10.1021/bp0341996 · Cited by 305
Stability of hydrogels used in cell encapsulation: An in vitro comparison of alginate and agarose
Shoichet, M. S., Li, R. H., White, M. L., & Winn, S. R. (1996) · Biotechnology and Bioengineering · doi:10.1002/(sici)1097-0290(19960520)50:4<374::aid-bit4>3.0.co;2-i · Cited by 296
Fabrication of three-dimensional porous cell-laden hydrogel for tissue engineering
Hwang, C. M., Sant, S., Masaeli, M., Kachouie, N. N., Zamanian, B., Lee, S.-H., & Khademhosseini, A. (2010) · Biofabrication · doi:10.1088/1758-5082/2/3/035003 · Cited by 285
Liver-Specific Functional Studies in a Microfluidic Array of Primary Mammalian Hepatocytes
Kane, B. J., Zinner, M. J., Yarmush, M. L., & Toner, M. (2006) · Analytical Chemistry · doi:10.1021/ac051856v · Cited by 264
Nakamura, T., Yoshimoto, K., Nakayama, Y., Tomita, Y., & Ichihara, A. (1983) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.80.23.7229 · Cited by 256
A microfluidic platform for complete mammalian cell culture
Barbulovic-Nad, I., Au, S. H., & Wheeler, A. R. (2010) · Lab on a Chip · doi:10.1039/c002147d · Cited by 249
Self-citationFobel, R., Fobel, C., & Wheeler, A. R. (2013) · Applied Physics Letters · doi:10.1063/1.4807118 · Cited by 218
Self-citationProgrammable large area digital microfluidic array with integrated droplet sensing for bioassays
Hadwen, B., Broder, G. R., Morganti, D., Jacobs, A., Brown, C., Hector, J. R., Kubota, Y., & Morgan, H. (2012) · Lab on a Chip · doi:10.1039/c2lc40273d · Cited by 211
Snyder, J. E., Hamid, Q., Wang, C., Chang, R., Emami, K., Wu, H., & Sun, W. (2011) · Biofabrication · doi:10.1088/1758-5082/3/3/034112 · Cited by 210
Albumin Usage in Clinical Medicine: Tradition or Therapeutic?
Farrugia, A. (2010) · Transfusion Medicine Reviews · doi:10.1016/j.tmrv.2009.09.005 · Cited by 196
A multicellular spheroid array to realize spheroid formation, culture, and viability assay on a chip
Torisawa, Y.-S., Takagi, A., Nashimoto, Y., Yasukawa, T., Shiku, H., & Matsue, T. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2006.08.054 · Cited by 176
Fan, S.-K., Huang, P.-W., Wang, T.-T., & Peng, Y.-H. (2008) · Lab on a Chip · doi:10.1039/b803204a · Cited by 167
Microfluidic synthesis of pure chitosan microfibers for bio-artificial liver chip
Lee, K. H., Shin, S. J., Kim, C.-B., Kim, J. K., Cho, Y. W., Chung, B. G., & Lee, S. (2010) · Lab on a Chip · doi:10.1039/b924987g · Cited by 145
Efficient assembly of rat hepatocyte spheroids for tissue engineering applications
Wu, F. J., Friend, J. R., Hsiao, C. C., Zilliox, M. J., Ko, W.-J., Cerra, F. B., & Hu, W.-S. (1996) · Biotechnology and Bioengineering · doi:10.1002/(sici)1097-0290(19960520)50:4<404::aid-bit7>3.0.co;2-p · Cited by 141
Paper Microfluidics Goes Digital
Fobel, R., Kirby, A. E., Ng, A. H. C., Farnood, R., & Wheeler, A. R. (2014) · Advanced Materials · doi:10.1002/adma.201305168 · Cited by 140
Self-citationGoral, V. N., Hsieh, Y., Petzold, O. N., Clark, J. S., Yuen, P. K., & Faris, R. A. (2010) · Lab on a Chip · doi:10.1039/c0lc00135j · Cited by 133
Integrated microbioreactor for culture and analysis of bacteria, algae and yeast
Au, S. H., Shih, S. C. C., & Wheeler, A. R. (2010) · Biomedical Microdevices · doi:10.1007/s10544-010-9469-3 · Cited by 133
Self-citationSeo, S.-J., Kim, I.-Y., Choi, Y., Akaike, T., & Cho, C. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2005.09.018 · Cited by 130
Digital microfluidics with impedance sensing for integrated cell culture andanalysis
Shih, S. C. C., Barbulovic-Nad, I., Yang, X., Fobel, R., & Wheeler, A. R. (2012) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2012.10.035 · Cited by 118
Self-citationA New Angle on Pluronic Additives: Advancing Droplets and Understanding in Digital Microfluidics
Au, S. H., Kumar, P., & Wheeler, A. R. (2011) · Langmuir · doi:10.1021/la201185c · Cited by 115
Self-citationMicrofluidic devices for in vitro studies on liver drug metabolism and toxicity
van Midwoud, P. M., Verpoorte, E., & Groothuis, G. M. M. (2011) · Integrative Biology · doi:10.1039/c0ib00119h · Cited by 115
A digital microfluidic platform for primary cell culture and analysis
Srigunapalan, S., Eydelnant, I. A., Simmons, C. A., & Wheeler, A. R. (2011) · Lab on a Chip · doi:10.1039/c1lc20844f · Cited by 105
Self-citationA digital microfluidic method for multiplexed cell-based apoptosis assays
Bogojevic, D., Chamberlain, M. D., Barbulovic-Nad, I., & Wheeler, A. R. (2012) · Lab Chip · doi:10.1039/c2lc20893h · Cited by 103
Self-citationItô, A., Jitsunobu, H., Kawabe, Y., & Kamihira, M. (2007) · Journal of Bioscience and Bioengineering · doi:10.1263/jbb.104.371 · Cited by 101
Eydelnant, I. A., Li, B. ‘., & Wheeler, A. R. (2014) · Nature Communications · doi:10.1038/ncomms4355 · Cited by 99
Self-citationDroplet-Scale Estrogen Assays in Breast Tissue, Blood, and Serum
Mousa, N. A., Jebrail, M. J., Yang, H., Abdelgawad, M. O., Metalnikov, P. S., Chen, J., Wheeler, A. R., & Casper, R. F. (2009) · Science Translational Medicine · doi:10.1126/scitranslmed.3000105 · Cited by 98
Self-citationMa, L., Barker, J., Zhou, C., Li, W., Zhang, J., Lin, B., Foltz, G., Küblbeck, J., & Honkakoski, P. (2012) · Biomaterials · doi:10.1016/j.biomaterials.2012.02.054 · Cited by 83
Manov, I., Hirsh, M., & Iancu, T. C. (2002) · Experimental and Toxicologic Pathology · doi:10.1078/0940-2993-00215 · Cited by 82
Liptrott, N. J., Penny, M., Bray, P., Sathish, J. G., Khoo, S., Back, D., & Owen, A. (2009) · British Journal of Pharmacology · doi:10.1111/j.1476-5381.2008.00050.x · Cited by 80
Evaluation of drug toxicity with hepatocytes cultured in a micro-space cell culture system
Nakamura, K., Mizutani, R., Sanbe, A., Enosawa, S., Kasahara, M., Nakagawa, A., Ejiri, Y., Murayama, N., Miyamoto, Y., Torii, T., et al. (2010) · Journal of Bioscience and Bioengineering · doi:10.1016/j.jbiosc.2010.08.008 · Cited by 63
N‐Acetylcysteine does not Protect HepG2 Cells against Acetaminophen‐Induced Apoptosis
Manov, I., Hirsh, M., & Iancu, T. C. (2004) · Basic & Clinical Pharmacology & Toxicology · doi:10.1111/j.1742-7843.2004.pto940504.x · Cited by 62
Integrated Digital Microfluidic Platform for Voltammetric Analysis
Dryden, M. D. M., Rackus, D. G., Shamsi, M. H., & Wheeler, A. R. (2013) · Analytical Chemistry · doi:10.1021/ac402003v · Cited by 62
Self-citationA simultaneous assessment of CYP3A4 metabolism and induction in the DPX-2 cell line
Trubetskoy, O. V., Marks, B. D., Zielinski, T. K., Yueh, M., & Raucy, J. L. (2005) · The AAPS Journal · doi:10.1208/aapsj070102 · Cited by 52
Au, S. H., Fobel, R., Desai, S. P., Voldman, J., & Wheeler, A. R. (2013) · Integrative Biology · doi:10.1039/c3ib40104a · Cited by 38
Self-citationCorrection: Cell Encapsulation in Sub-mm Sized Gel Modules Using Replica Molding
McGuigan, A. P., Bruzewicz, D. A., Glavan, A. C., Butte, M. J., & Whitesides, G. M. (2008) · PLoS ONE · doi:10.1371/annotation/0a0b70a9-a6e0-4e60-b6bd-8ef894ed22cd · Cited by 10
Research works printed but not linked: 2
- Mugele, 2005, J. Phys.: Condens. Matter, 17, R705
- Fiddes, 2012, Biomicrofluidics, 6
Cited by
Park, S. E., Georgescu, A., & Huh, D. (2019) · Science · doi:10.1126/science.aaw7894 · Cited by 847
Organoid-on-a-chip and body-on-a-chip systems for drug screening and disease modeling
Skardal, A., Shupe, T., & Atala, A. (2016) · Drug Discovery Today · doi:10.1016/j.drudis.2016.07.003 · Cited by 512
“These arrays of 3D organoids had increased liver function compared with 2D controls, and responded to acetaminophen in a drug-screening experiment [28].”
BackgroundMoshksayan, K., Kashaninejad, N., Warkiani, M. E., Lock, J. G., Moghadas, H., Firoozabadi, B., Saidi, M. S., & Nguyen, N.-T. (2018) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2018.01.223 · Cited by 267
Yoon No, D., Lee, K.-H., Lee, J., & Lee, S.-H. (2015) · Lab on a Chip · doi:10.1039/c5lc00611b · Cited by 205
Microfluidic organ-on-a-chip models of human liver tissue
Moradi, E., Jalili-Firoozinezhad, S., & Solati-Hashjin, M. (2020) · Acta Biomaterialia · doi:10.1016/j.actbio.2020.08.041 · Cited by 204
Metadata
- Authors
- Au, S. H., Chamberlain, M. D., Mahesh, S., Sefton, M. V., & Wheeler, A. R.
- Affiliations
- University of Toronto (CA)
- Corresponding author
- Wheeler, Aaron R.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2014-07-02
- Volume
- 14
- Issue
- 17
- Pages
- 3290
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2041356700
- Cited by
- 162
- References
- 50
- Citations by year
- 2026: 3 · 2025: 15 · 2024: 16 · 2023: 11 · 2022: 9 · 2021: 16 · 2020: 21 · 2019: 17 · 2018: 12 · 2017: 15 · 2016: 17 · 2015: 7 · 2014: 3
- FWCI
- 7.26
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Lab on a Chip (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Canadian Institutes of Health Research
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Health Sciences › Medicine › Surgery › Tissue Engineering and Regenerative Medicine
- Keywords
- liver organoids, microfluidic organoids, hepatotoxicity screening, HepG2 cells, NIH3T3 cells, co-culture, CYP3A4, albumin secretion, fibroblast contraction, acetaminophen toxicity, apoptosis, necrosis, 3D cell culture, drug discovery
- MeSH terms
- Animals, Pharmaceutical Preparations, Humans, Liver, NIH 3T3 Cells, Microfluidic Analytical Techniques, Mice, Hep G2 Cells
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.