CoChat

Removal of Contaminants in Stormwater via Subsurface-Flow Wetlands: A Review with Focus on Nutrients, Heavy Metals, and PFAS

Goukeh, Mojtaba Nouri, Alamdari, Nasrin · 2024 · Journal of Environmental Engineering

The DOI matches its Crossref record; 166 of the 166 references it cites were found in a registry or an index.

Abstract

Subsurface-flow constructed wetlands (SSF CWs), which include horizontal subsurface–flow constructed wetlands (HSSF CWs) and vertical subsurface–flow constructed wetlands (VSSF CWs), have become increasingly popular for the treatment of various waste streams such as wastewater, landfill leachate, and stormwater runoff. These wetlands utilize a variety of natural physical, chemical, and microbial processes to effectively remove contaminants. This article aims to provide valuable insights into the application of subsurface-flow wetlands for the treatment of stormwater runoff by collecting and reviewing relevant articles. Within the realm of stormwater contaminants, this review primarily focuses on nutrients, heavy metal, and per- and polyfluoroalkyl substances (PFAS), which are commonly found in stormwater runoff worldwide. The removal percentages of these contaminants vary across different studies, depending on factors such as the characteristics of the contaminants, the type and scale of the subsurface-flow wetland, as well as the selection of plants and substrates used. This study provides valuable insights into the various processes that significantly contribute to the removal of contaminants, including adsorption, plant uptake, and biodegradation. The removal percentage of PFAS ranges from 1% to 99% in constructed wetlands. The wide range of PFAS removal comes from differences between PFAS category, plant and soil type, wetland configuration, and matrix effects. Additionally, this paper brings attention to the current gaps and limitations present in the research conducted within this field. It is imperative to conduct further studies utilizing real-world or synthetic stormwater runoff to deepen our comprehension in this domain. Furthermore, considering that each category of PFAS possesses unique properties, conducting individual studies on each group becomes crucial to attain a comprehensive understanding of the behavior and transformation of PFAS in CWs.

Overview

Integrity signals

Registry

Crossref · 10.1061/joeedu.eeeng-7478

Cites

166 of 166 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Research works printed but not linked: 2

  1. Ding, D., Y. Yang, L. Wu, Q. Zhang, and S. Yue. 2016. “Effect of step-feeding on nitrification and denitrification characteristics of a deep bed tidal flow constructed wetland system.” Water Treatment 42 (11): 104–109.
  2. Zhang, K., H. Li, D. Fu, F. Zhou, and M. Chen. 2011. “Characteristics of heavy metal pollution in runoff from three different types of roofs.” Huanjing Kexue Xuebao 31 (4): 724–730.

Cited by

See all 25

Metadata

Authors
Goukeh, M. N., & Alamdari, N.
Affiliations
Florida State University (US)
Venue
Journal of Environmental Engineering
Published
2024-03
Volume
150
Issue
3
ISSN
  • 0733-9372 (ISSN-L)
  • 1943-7870
OpenAlex
W4390807288
Cited by
22
References
166
Citations by year
2026: 5 · 2025: 9 · 2024: 8
FWCI
5.98
Type
journal article
Language
en
Open access
closed
Locations
Journal of Environmental Engineering (publishedVersion)
Topics
  • Physical Sciences › Environmental Science › Waste Management and Disposal › Constructed Wetlands for Wastewater Treatment
  • Physical Sciences › Environmental Science › Environmental Engineering › Urban Stormwater Management Solutions
  • Physical Sciences › Environmental Science › Waste Management and Disposal › Wastewater Treatment and Reuse
Keywords
subsurface flow constructed wetlands, stormwater runoff, nutrient removal, heavy metal removal, PFAS removal, horizontal subsurface flow wetland, adsorption, plant uptake, biodegradation, wetland substrate, aquatic plants

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.