The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Wide-field subdiffraction imaging by accumulated binding of diffusing probes
Open accessAbstract
A method is introduced for subdiffraction imaging that accumulates points by collisional flux. It is based on targeting the surface of objects by fluorescent probes diffusing in the solution. Because the flux of probes at the object is essentially constant over long time periods, the examination of an almost unlimited number of individual probe molecules becomes possible. Each probe that hits the object and that becomes immobilized is located with high precision by replacing its point-spread function by a point at its centroid. Images of lipid bilayers, contours of these bilayers, and large unilamellar vesicles are shown. A spatial resolution of ≈25 nm is readily achieved. The ability of the method to effect rapid nanoscale imaging and spatial resolution below Rayleigh criterion and without the necessity for labeling with fluorescent probes is proven.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Imaging Intracellular Fluorescent Proteins at Nanometer Resolution
Betzig, E., Patterson, G. H., Sougrat, R., Lindwasser, O. W., Olenych, S., Bonifacino, J. S., Davidson, M. W., Lippincott-Schwartz, J., & Hess, H. F. (2006) · Science · doi:10.1126/science.1127344 · Cited by 8,772
Zwischenmolekulare Energiewanderung und Fluoreszenz
Förster, T. (1948) · Annalen der Physik · doi:10.1002/andp.19484370105 · Cited by 8,285
Sub-diffraction-limit imaging by stochastic optical reconstruction microscopy (STORM)
Rust, M. J., Bates, M., & Zhuang, X. (2006) · Nature Methods · doi:10.1038/nmeth929 · Cited by 8,078
Evidence for the Formation of Symmetric and Asymmetric DLPC-DAPC Lipid Bilayer Domains
Ritter, M., Schmidt, S., Jakab, M., Paulmichl, M., & Henderson, R. (2013) · Cellular Physiology and Biochemistry · doi:10.1159/000350122 · Cited by 3,923
Precise Nanometer Localization Analysis for Individual Fluorescent Probes
Thompson, R. E., Larson, D. R., & Webb, W. W. (2002) · Biophysical Journal · doi:10.1016/s0006-3495(02)75618-x · Cited by 2,320
Myosin V Walks Hand-Over-Hand: Single Fluorophore Imaging with 1.5-nm Localization
Yildiz, A., Forkey, J. N., McKinney, S. A., Ha, T., Goldman, Y. E., & Selvin, P. R. (2003) · Science · doi:10.1126/science.1084398 · Cited by 1,837
SINGLE-PARTICLE TRACKING:Applications to Membrane Dynamics
Saxton, M. J., & Jacobson, K. (1997) · Annual Review of Biophysics and Biomolecular Structure · doi:10.1146/annurev.biophys.26.1.373 · Cited by 1,810
Quantitative Comparison of Algorithms for Tracking Single Fluorescent Particles
Cheezum, M. K., Walker, W. F., & Guilford, W. H. (2001) · Biophysical Journal · doi:10.1016/s0006-3495(01)75884-5 · Cited by 896
Eggeling, C., Widengren, J., Rigler, R., & Seidel, C. A. M. (1998) · Analytical Chemistry · doi:10.1021/ac980027p · Cited by 718
Position measurement with a resolution and noise-limited instrument
Bobroff, N. (1986) · Review of Scientific Instruments · doi:10.1063/1.1138619 · Cited by 375
Chapter 9 Total Internal Reflection Fluorescence Microscopy
(1989) · Methods in Cell Biology · doi:10.1016/s0091-679x(08)60982-6 · Cited by 374
Single-molecule high-resolution imaging with photobleaching
Gordon, M. P., Ha, T., & Selvin, P. R. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0401638101 · Cited by 372
Superresolution by localization of quantum dots using blinking statistics
Lidke, K. A., Rieger, B., Jovin, T. M., & Heintzmann, R. (2005) · Optics Express · doi:10.1364/opex.13.007052 · Cited by 361
Nanometer-localized multiple single-molecule fluorescence microscopy
Qu, X., Wu, D., Mets, L., & Scherer, N. F. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0402155101 · Cited by 304
Tinnefeld, P., & Sauer, M. (2005) · Angewandte Chemie International Edition · doi:10.1002/anie.200300647 · Cited by 251
Early Steps of Supported Bilayer Formation Probed by Single Vesicle Fluorescence Assays
Johnson, J. M., Ha, T., Chu, S., & Boxer, S. G. (2002) · Biophysical Journal · doi:10.1016/s0006-3495(02)75337-x · Cited by 246
Effect of rotation on the diffusion-controlled rate of ligand-protein association.
Hill, T. L. (1975) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.72.12.4918 · Cited by 166
A mechanism of liposome electroformation
Angelova, M. I., & Dimitrov, D. S. (2007) · Steinkopff eBooks · doi:10.1007/bfb0114171 · Cited by 150
Direct Measurement of the End‐to‐End Distance of Individual Polyfluorene Polymer Chains
Muls, B., Uji‐i, H., Melnikov, S., Moussa, A., Verheijen, W., Soumillion, J., Josemon, J., Müllen, K., & Hofkens, J. (2005) · ChemPhysChem · doi:10.1002/cphc.200500235 · Cited by 56
Probing Lipid Vesicles by Bimolecular Association and Dissociation Trajectories of Single Molecules
Gao, F., Mei, E., Lim, M., & Hochstrasser, R. M. (2006) · Journal of the American Chemical Society · doi:10.1021/ja058098a · Cited by 47
Self-citationAnomalously Slow Diffusion of Single Molecules near a Patterned Surface
(2004) · doi:10.1021/jp0482161 · Cited by 14
Controlled bimolecular collisions allow sub-diffraction limited microscopy of lipid vesicles
Mei, E., Gao, F., & Hochstrasser, R. M. (2006) · Physical Chemistry Chemical Physics · doi:10.1039/b601670g · Cited by 12
Self-citationDirect visualization of nanopatterns by single-molecule imaging
Mei, E., Sharonov, A., Ferris, J. H., & Hochstrasser, R. M. (2005) · Applied Physics Letters · doi:10.1063/1.1850608 · Cited by 6
Self-citation
Cited by
Hell, S. W. (2007) · Science · doi:10.1126/science.1137395 · Cited by 2,967
Three-Dimensional Super-Resolution Imaging by Stochastic Optical Reconstruction Microscopy
Huang, B., Wang, W., Bates, M., & Zhuang, X. (2008) · Science · doi:10.1126/science.1153529 · Cited by 2,796
Subdiffraction‐Resolution Fluorescence Imaging with Conventional Fluorescent Probes
Heilemann, M., van de Linde, S., Schüttpelz, M., Kasper, R., Seefeldt, B., Mukherjee, A., Tinnefeld, P., & Sauer, M. (2008) · Angewandte Chemie International Edition · doi:10.1002/anie.200802376 · Cited by 1,866
Super-resolution fluorescence microscopy
Huang, B., Bates, M., & Zhuang, X. (2009) · Annual Review of Biochemistry · doi:10.1146/annurev.biochem.77.061906.092014 · Cited by 1,657
Multicolor Super-Resolution Imaging with Photo-Switchable Fluorescent Probes
Bates, M., Huang, B., Dempsey, G. T., & Zhuang, X. (2007) · Science · doi:10.1126/science.1146598 · Cited by 1,504
Metadata
- Authors
- Sharonov, A., & Hochstrasser, R. M.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2006-12-12
- Volume
- 103
- Issue
- 50
- Pages
- 18911-18916
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2021810362
- Cited by
- 1,151
- References
- 23
- FWCI
- 9.45
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.