In vivo imaging of hydrogen peroxide production in a murine tumor model with a chemoselective bioluminescent reporter
Open accessThe DOI matches its Crossref record; 48 of the 48 references it cites were found in a registry or an index.
Abstract
Living organisms produce hydrogen peroxide (H 2 O 2 ) to kill invading pathogens and for cellular signaling, but aberrant generation of this reactive oxygen species is a hallmark of oxidative stress and inflammation in aging, injury, and disease. The effects of H 2 O 2 on the overall health of living animals remain elusive, in part owing to a dearth of methods for studying this transient small molecule in vivo. Here we report the design, synthesis, and in vivo applications of Peroxy Caged Luciferin-1 (PCL-1), a chemoselective bioluminescent probe for the real-time detection of H 2 O 2 within living animals. PCL-1 is a boronic acid-caged firefly luciferin molecule that selectively reacts with H 2 O 2 to release firefly luciferin, which triggers a bioluminescent response in the presence of firefly luciferase. The high sensitivity and selectivity of PCL-1 for H 2 O 2 , combined with the favorable properties of bioluminescence for in vivo imaging, afford a unique technology for real-time detection of basal levels of H 2 O 2 generated in healthy, living mice. Moreover, we demonstrate the efficacy of PCL-1 for monitoring physiological fluctuations in H 2 O 2 levels by directly imaging elevations in H 2 O 2 within testosterone-stimulated tumor xenografts in vivo. The ability to chemoselectively monitor H 2 O 2 fluxes in real time in living animals offers opportunities to dissect H 2 O 2 ’s disparate contributions to health, aging, and disease.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mitochondrial Dysfunction and Oxidative Stress in Neurodegenerative Diseases
Lin, M. T., & Beal, M. F. (2006) · Nature · doi:10.1038/nature05292 · Cited by 6,455 · cited 1×
“However, imbalances in H2O2 production lead to oxidative stress and inflammation events, which damage tissue and organ systems and are correlated with the onset and advancement of various diseases, including cancer (7, 8), diabetes (9, 10), and cardiovascular (11, 12) and neurodegenerative (13, 14) diseases.”
BackgroundNeurodegenerative diseases and oxidative stress
Barnham, K. J., Masters, C. L., & Bush, A. I. (2004) · Nature Reviews Drug Discovery · doi:10.1038/nrd1330 · Cited by 3,683 · cited 1×
“However, imbalances in H2O2 production lead to oxidative stress and inflammation events, which damage tissue and organ systems and are correlated with the onset and advancement of various diseases, including cancer (7, 8), diabetes (9, 10), and cardiovascular (11, 12) and neurodegenerative (13, 14) diseases.”
BackgroundROS as signalling molecules: Mechanisms that generate specificity in ROS homeostasis
D'Autréaux, B., & Toledano, M. B. (2007) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm2256 · Cited by 3,642
Reactive oxygen species have a causal role in multiple forms of insulin resistance
Houstis, N., Rosen, E. D., & Lander, E. S. (2006) · Nature · doi:10.1038/nature04634 · Cited by 2,525 · cited 1×
“However, imbalances in H2O2 production lead to oxidative stress and inflammation events, which damage tissue and organ systems and are correlated with the onset and advancement of various diseases, including cancer (7, 8), diabetes (9, 10), and cardiovascular (11, 12) and neurodegenerative (13, 14) diseases.”
BackgroundReconciling the chemistry and biology of reactive oxygen species
Winterbourn, C. C. (2008) · Nature Chemical Biology · doi:10.1038/nchembio.85 · Cited by 2,504
H 2 O 2 , a Necessary Evil for Cell Signaling
Rhee, S. G. (2006) · Science · doi:10.1126/science.1130481 · Cited by 2,160
Genetically encoded fluorescent indicator for intracellular hydrogen peroxide
Belousov, V. V., Fradkov, A. F., Lukyanov, K. A., Staroverov, D. B., Shakhbazov, K. S., Terskikh, A. V., & Lukyanov, S. (2006) · Nature Methods · doi:10.1038/nmeth866 · Cited by 1,258
Hydrogen Peroxide: A Signaling Messenger
Stone, J. R., & Yang, S. (2006) · Antioxidants & Redox Signaling · doi:10.1089/ars.2006.8.243 · Cited by 1,172
The common biology of cancer and ageing
Finkel, T., Serrano, M., & Blasco, M. A. (2007) · Nature · doi:10.1038/nature05985 · Cited by 988 · cited 1×
“However, imbalances in H2O2 production lead to oxidative stress and inflammation events, which damage tissue and organ systems and are correlated with the onset and advancement of various diseases, including cancer (7, 8), diabetes (9, 10), and cardiovascular (11, 12) and neurodegenerative (13, 14) diseases.”
BackgroundStems Cells and the Pathways to Aging and Cancer
Rossi, D. J., Jamieson, C. H. M., & Weissman, I. L. (2008) · Cell · doi:10.1016/j.cell.2008.01.036 · Cited by 895
Cited by
Reaction-based small-molecule fluorescent probes for chemoselective bioimaging
Chan, J., Dodani, S. C., & Chang, C. J. (2012) · Nature Chemistry · doi:10.1038/nchem.1500 · Cited by 1,883
Self-citationChemistry and biology of reactive oxygen species in signaling or stress responses
Dickinson, B. C., & Chang, C. J. (2011) · Nature Chemical Biology · doi:10.1038/nchembio.607 · Cited by 1,821
Self-citationDesign Strategies for Water-Soluble Small Molecular Chromogenic and Fluorogenic Probes
Li, X., Gao, X., Shi, W., & Ma, H. (2014) · Chemical Reviews · doi:10.1021/cr300508p · Cited by 1,729
Guidelines for measuring reactive oxygen species and oxidative damage in cells and in vivo
Murphy, M. P., Bayir, H., Belousov, V., Chang, C. J., Davies, K. J. A., Davies, M. J., Dick, T. P., Finkel, T., Forman, H. J., Janssen-Heininger, Y., et al. (2022) · Nature Metabolism · doi:10.1038/s42255-022-00591-z · Cited by 1,514
Self-citationLippert, A. R., Van de Bittner, G. C., & Chang, C. J. (2011) · Accounts of Chemical Research · doi:10.1021/ar200126t · Cited by 798
Self-citationPhotoacoustic Imaging: Contrast Agents and Their Biomedical Applications
Fu, Q., Zhu, R., Song, J., Yang, H., & Chen, X. (2019) · Advanced Materials · doi:10.1002/adma.201805875 · Cited by 681
Yu, F., Li, P., Wang, B., & Han, K. (2013) · Journal of the American Chemical Society · doi:10.1021/ja401360a · Cited by 621
de Gracia Lux, C., Joshi-Barr, S., Nguyen, T., Mahmoud, E., Schopf, E., Fomina, N., & Almutairi, A. (2012) · Journal of the American Chemical Society · doi:10.1021/ja303372u · Cited by 598
Chen, Q., Liang, C., Sun, X., Chen, J., Yang, Z., Zhao, H., Feng, L., & Liu, Z. (2017) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1701976114 · Cited by 535
ROS production in phagocytes: Why, when, and where?
Dupré-Crochet, S., Erard, M., & Nüβe, O. (2013) · Journal of Leukocyte Biology · doi:10.1189/jlb.1012544 · Cited by 467
Noh, J., Kwon, B., Han, E., Park, M., Yang, W., Cho, W., Yoo, W., Khang, G., & Lee, D. (2015) · Nature Communications · doi:10.1038/ncomms7907 · Cited by 461
Glucose Sensing in Supramolecular Chemistry
Sun, X., & James, T. D. (2015) · Chemical Reviews · doi:10.1021/cr500562m · Cited by 386
Luminescent probes for the bioimaging of small anionic species in vitro and in vivo
Ashton, T. D., Jolliffe, K. A., & Pfeffer, F. M. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00372a · Cited by 367
Karton-Lifshin, N., Segal, E., Omer, L., Portnoy, M., Satchi-Fainaro, R., & Shabat, D. (2011) · Journal of the American Chemical Society · doi:10.1021/ja203145v · Cited by 366
Designing nanozymes for in vivo applications
Zhang, R., Jiang, B., Fan, K., Gao, L., & Yan, X. (2024) · Nature Reviews Bioengineering · doi:10.1038/s44222-024-00205-1 · Cited by 360
Tumor microenvironment-responsive intelligent nanoplatforms for cancer theranostics
Gong, F., Yang, N., Wang, X., Zhao, Q., Chen, Q., Liu, Z., & Cheng, L. (2020) · Nano Today · doi:10.1016/j.nantod.2020.100851 · Cited by 359
Applications of bioluminescence in biotechnology and beyond
Syed, A. J., & Anderson, J. C. (2021) · Chemical Society Reviews · doi:10.1039/d0cs01492c · Cited by 341
Zhen, X., Zhang, C., Xie, C., Miao, Q., Lim, K. L., & Pu, K. (2016) · ACS Nano · doi:10.1021/acsnano.6b02908 · Cited by 340
Dual-locked spectroscopic probes for sensing and therapy
Wu, L., Huang, J., Pu, K., & James, T. D. (2021) · Nature Reviews Chemistry · doi:10.1038/s41570-021-00277-2 · Cited by 328
Chemiluminescence-Guided Cancer Therapy Using a Chemiexcited Photosensitizer
Mao, D., Wu, W., Ji, S., Chen, C., Hu, F., Kong, D., Ding, D., & Liu, B. (2017) · Chem · doi:10.1016/j.chempr.2017.10.002 · Cited by 317
Forman, H. J., Augusto, O., Brigelius-Flohe, R., Dennery, P. A., Kalyanaraman, B., Ischiropoulos, H., Mann, G. E., Radi, R., Roberts, L. J., Vina, J., et al. (2015) · Free Radical Biology and Medicine · doi:10.1016/j.freeradbiomed.2014.10.504 · Cited by 303
Cui, Y., Chen, F., & Yin, X.-B. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2019.04.008 · Cited by 296
Van de Bittner, G. C., Bertozzi, C. R., & Chang, C. J. (2013) · Journal of the American Chemical Society · doi:10.1021/ja309078t · Cited by 292
Self-citationBioluminescence imaging: progress and applications
Badr, C. E., & Tannous, B. A. (2011) · Trends in Biotechnology · doi:10.1016/j.tibtech.2011.06.010 · Cited by 292
Barja, G. (2013) · Antioxidants & Redox Signaling · doi:10.1089/ars.2012.5148 · Cited by 290
“Unfortunately, in spite of some significant recent advances in that direction (4, 31, 103, 171), that is still not possible.”
BackgroundIn Vivo Molecular Bioluminescence Imaging: New Tools and Applications
Mezzanotte, L., van ‘t Root, M., Karatas, H., Goun, E. A., & Löwik, C. W. G. M. (2017) · Trends in Biotechnology · doi:10.1016/j.tibtech.2017.03.012 · Cited by 288
The peroxisome: an update on mysteries
Islinger, M., Grille, S., Fahimi, H. D., & Schrader, M. (2012) · Histochemistry and Cell Biology · doi:10.1007/s00418-012-0941-4 · Cited by 281
Boron Chemicals in Diagnosis and Therapeutics
Das, B. C., Thapa, P., Karki, R., Schinke, C., Das, S., Kambhampati, S., Banerjee, S. K., Van Veldhuizen, P., Verma, A., Weiss, L. M., et al. (2013) · Future Medicinal Chemistry · doi:10.4155/fmc.13.38 · Cited by 279
Martinez-Outschoorn, U. E., Lin, Z., Trimmer, C., Flomenberg, N., Wang, C., Pavlides, S., Pestell, R. G., Howell, A., Sotgia, F., & Lisanti, M. P. (2011) · Cell Cycle · doi:10.4161/cc.10.15.16585 · Cited by 270
Hollow Cu2Se Nanozymes for Tumor Photothermal-Catalytic Therapy
Wang, X., Zhong, X., Lei, H., Geng, Y., Zhao, Q., Gong, F., Yang, Z., Dong, Z., Liu, Z., & Cheng, L. (2019) · Chemistry of Materials · doi:10.1021/acs.chemmater.9b01958 · Cited by 270
Wang, P., Gong, Q., Hu, J., Li, X., & Zhang, X. (2021) · Journal of Medicinal Chemistry · doi:10.1021/acs.jmedchem.0c01704 · Cited by 270
Activity‐Based Sensing: A Synthetic Methods Approach for Selective Molecular Imaging and Beyond
Bruemmer, K. J., Crossley, S. W. M., & Chang, C. J. (2020) · Angewandte Chemie International Edition · doi:10.1002/anie.201909690 · Cited by 265
Self-citationFluorescent probes for sensing and imaging biological hydrogen sulfide
Lin, V. S., & Chang, C. J. (2012) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2012.07.014 · Cited by 260
Self-citationMicro- and nano-motors for biomedical applications
Abdelmohsen, L. K. E. A., Peng, F., Tu, Y., & Wilson, D. A. (2014) · J. Mater. Chem. B · doi:10.1039/c3tb21451f · Cited by 244
Boronate Probes as Diagnostic Tools for Real Time Monitoring of Peroxynitrite and Hydroperoxides
Zielonka, J., Sikora, A., Hardy, M., Joseph, J., Dranka, B. P., & Kalyanaraman, B. (2012) · Chemical Research in Toxicology · doi:10.1021/tx300164j · Cited by 240
In Vivo Targeting of Hydrogen Peroxide by Activatable Cell-Penetrating Peptides
Weinstain, R., Savariar, E. N., Felsen, C. N., & Tsien, R. Y. (2014) · Journal of the American Chemical Society · doi:10.1021/ja411547j · Cited by 239
Lisanti, M. P., Martinez-Outschoorn, U. E., Lin, Z., Pavlides, S., Whitaker-Menezes, D., Pestell, R. G., Howell, A., & Sotgia, F. (2011) · Cell Cycle · doi:10.4161/cc.10.15.16870 · Cited by 234
Sun, X., Xu, Q., Kim, G., Flower, S. E., Lowe, J. P., Yoon, J., Fossey, J. S., Qian, X., Bull, S. D., & James, T. D. (2014) · Chemical Science · doi:10.1039/c4sc01417k · Cited by 218
Advances in Fluorescence and Bioluminescence Imaging
Ozawa, T., Yoshimura, H., & Kim, S. B. (2013) · Analytical Chemistry · doi:10.1021/ac3031724 · Cited by 217
Development and Applications of Bioluminescent and Chemiluminescent Reporters and Biosensors
Yeh, H.-W., & Ai, H.-W. (2019) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-061318-115027 · Cited by 215
“This approach has also been expanded to image metabolites, reactive small molecules, ormetal ions, such as hydrogen peroxide (85), hydrogen sulfide (86), hypochlorite (87), nitric oxide (88), fluoride (89), copper (90), and ferrous (91).”
BackgroundSmall‐Molecule Prodrug Nanoassemblies: An Emerging Nanoplatform for Anticancer Drug Delivery
Li, G., Sun, B., Li, Y., Luo, C., He, Z., & Sun, J. (2021) · Small · doi:10.1002/smll.202101460 · Cited by 205
Enhanced Phototherapy by Nanoparticle-Enzyme via Generation and Photolysis of Hydrogen Peroxide
Chang, K., Liu, Z., Fang, X., Chen, H., Men, X., Yuan, Y., Sun, K., Zhang, X., Yuan, Z., & Wu, C. (2017) · Nano Letters · doi:10.1021/acs.nanolett.7b01382 · Cited by 204
Chen, J., Shu, Y., Li, H., Xu, Q., & Hu, X. (2018) · Talanta · doi:10.1016/j.talanta.2018.06.075 · Cited by 201
Cage the firefly luciferin! – a strategy for developing bioluminescent probes
Li, J., Chen, L., Du, L., & Li, M. (2013) · Chem. Soc. Rev. · doi:10.1039/c2cs35249d · Cited by 200
Hananya, N., & Shabat, D. (2017) · Angewandte Chemie International Edition · doi:10.1002/anie.201706969 · Cited by 191
Ye, S., Hananya, N., Green, O., Chen, H., Zhao, A. Q., Shen, J., Shabat, D., & Yang, D. (2020) · Angewandte Chemie International Edition · doi:10.1002/anie.202005429 · Cited by 185
Recent advances in reactive oxygen species measurement in biological systems
Woolley, J. F., Stanicka, J., & Cotter, T. G. (2013) · Trends in Biochemical Sciences · doi:10.1016/j.tibs.2013.08.009 · Cited by 179
Bailey, T. S., & Pluth, M. D. (2013) · Journal of the American Chemical Society · doi:10.1021/ja408909h · Cited by 178
Wang, Q., Yang, Y., Gao, F., Ni, J., Zhang, Y., & Lin, Z. (2016) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.6b11965 · Cited by 177
Understanding and preventing mitochondrial oxidative damage
Murphy, M. P. (2016) · Biochemical Society Transactions · doi:10.1042/bst20160108 · Cited by 160
Zhou, L., Chen, X., Liu, T., Gong, Y., Chen, S., Pan, G., Cui, W., Luo, Z., Pei, M., Yang, H., et al. (2015) · Journal of Pineal Research · doi:10.1111/jpi.12250 · Cited by 158
Acinetobacter baumannii OxyR Regulates the Transcriptional Response to Hydrogen Peroxide
Juttukonda, L. J., Green, E. R., Lonergan, Z. R., Heffern, M. C., Chang, C. J., & Skaar, E. P. (2019) · Infection and Immunity · doi:10.1128/iai.00413-18 · Cited by 75
Self-citationROS-Activated Ratiometric Fluorescent Polymeric Nanoparticles for Self-Reporting Drug Delivery
Zhang, M., Song, C.-C., Su, S., Du, F.-S., & Li, Z.-C. (2018) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.7b18438 · Cited by 64
Metadata
- Authors
- Van de Bittner, G. C., Dubikovskaya, E. A., Bertozzi, C. R., & Chang, C. J.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2010-11-29
- Volume
- 107
- Issue
- 50
- Pages
- 21316-21321
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2131106253
- Cited by
- 403
- References
- 48
- FWCI
- 8.27
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.