Restoring the sense of touch with a prosthetic hand through a brain interface
Open accessThe DOI matches its Crossref record; 38 of the 39 references it cites were found in a registry or an index.
Abstract
Significance: Our ability to manipulate objects relies fundamentally on sensory signals originating from the hand. To restore motor function with upper-limb neuroprostheses requires that somatosensory feedback be provided to the tetraplegic patient or amputee. Accordingly, we have developed approaches to convey sensory information critical for object manipulation—information about contact location, pressure, and timing—through intracortical microstimulation of somatosensory cortex. In experiments with nonhuman primates, we show that we can elicit percepts that are projected to a localized patch of skin, that track the pressure exerted on the skin, and that signal the timing of contact events. We anticipate that the proposed biomimetic feedback will constitute an important step in restoring touch to individuals who have lost it.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“An experiment on the biomimetic method in non-human primates was conducted by delivering ICMS to area S1 in order to convey sensory information on the location of a contact in the hand; it was found that the receptive field of ICMS was highly localized to elicit percepts on the hand or even fingertips (Tabot et al., 2013).”
From Selectivity and Longevity of Peripheral-Nerve and Machine Interfaces: A Review. (2017) · cites this paper as Tabot et al., 2013
Citations
Cites
Rubber hands ‘feel’ touch that eyes see
Botvinick, M., & Cohen, J. (1998) · Nature · doi:10.1038/35784 · Cited by 4,410
Coding and use of tactile signals from the fingertips in object manipulation tasks
Johansson, R. S., & Flanagan, J. R. (2009) · Nature Reviews Neuroscience · doi:10.1038/nrn2621 · Cited by 2,063 · cited 4×
“These temporally precise responses are relatively insensitive to object properties (14) and critical in guiding the dexterous manipulation of objects (9).”
BackgroundInfluentialJohansson, R. S., & Westling, G. (1984) · Experimental Brain Research · doi:10.1007/bf00237997 · Cited by 1,703 · cited 1×
“Cutaneous afferents also signal when our grip on an object is slipping (26).”
BackgroundThe perception of phantom limbs. The D. O. Hebb lecture
Ramachandran, V. (1998) · Brain · doi:10.1093/brain/121.9.1603 · Cited by 1,064
Projecting sensations to external objects: evidence from skin conductance response
Armel, K. C., & Ramachandran, V. S. (2003) · Proceedings of the Royal Society of London. Series B: Biological Sciences · doi:10.1098/rspb.2003.2364 · Cited by 854
Schmidt, E. M., Bak, M. J., Hambrecht, F. T., Kufta, C. V., O'Rourke, D. K., & Vallabhanath, P. (1996) · Brain · doi:10.1093/brain/119.2.507 · Cited by 672
Active tactile exploration using a brain–machine–brain interface
O’Doherty, J. E., Lebedev, M. A., Ifft, P. J., Zhuang, K. Z., Shokur, S., Bleuler, H., & Nicolelis, M. A. L. (2011) · Nature · doi:10.1038/nature10489 · Cited by 629
Histed, M. H., Bonin, V., & Reid, R. C. (2009) · Neuron · doi:10.1016/j.neuron.2009.07.016 · Cited by 604
Somatosensory discrimination based on cortical microstimulation
Romo, R., Hernández, A., Zainos, A., & Salinas, E. (1998) · Nature · doi:10.1038/32891 · Cited by 473 · cited 1×
“One way to circumvent this obstacle is to train animals to discriminate sensory stimuli along a dimension of interest, and then to assess whether the animals can perform the task when physical stimuli are replaced with ICMS (2, 3).”
BackgroundOchoa, J., & Torebjörk, E. (1983) · The Journal of Physiology · doi:10.1113/jphysiol.1983.sp014873 · Cited by 467 · cited 1×
“Indeed, signals from mechanoreceptive afferents in the skin convey information about the location of contact (19, 20) and about the forces exerted on the skin when an object is grasped (21–25).”
BackgroundDirect and Indirect Activation of Cortical Neurons by Electrical Microstimulation
Tehovnik, E. J., Tolias, A. S., Sultan, F., Slocum, W. M., & Logothetis, N. K. (2006) · Journal of Neurophysiology · doi:10.1152/jn.00126.2006 · Cited by 357
Robotic touch shifts perception of embodiment to a prosthesis in targeted reinnervation amputees
Marasco, P. D., Kim, K., Colgate, J. E., Peshkin, M. A., & Kuiken, T. A. (2011) · Brain · doi:10.1093/brain/awq361 · Cited by 335
Stimulus‐response functions of slowly adapting mechanoreceptors in the human glabrous skin area.
Knibestöl, M. (1975) · The Journal of Physiology · doi:10.1113/jphysiol.1975.sp010835 · Cited by 335
Visual sensations produced by intracortical microstimulation of the human occipital cortex
Bak, M., Girvin, J. P., Hambrecht, F. T., Kufta, C. V., Loeb, G. E., & Schmidt, E. M. (1990) · Medical & Biological Engineering & Computing · doi:10.1007/bf02442682 · Cited by 299 · cited 1×
“The question remains whether the quality of the percept changes as ICMS amplitude increases, a question that can be addressed only in experiments with human subjects (32, 33).”
BackgroundRomo, R., Hernández, A., Zainos, A., Brody, C. D., & Lemus, L. (2000) · Neuron · doi:10.1016/s0896-6273(00)81156-3 · Cited by 270 · cited 2×
“Trans Neural Syst Rehabil Eng 21(3):500–507.”
BackgroundStimulus—response functions of rapidly adapting mechanoreceptors in the human glabrous skin area
Knibestöl, M. (1973) · The Journal of Physiology · doi:10.1113/jphysiol.1973.sp010279 · Cited by 258
Muniak, M. A., Ray, S., Hsiao, S. S., Dammann, J. F., & Bensmaia, S. J. (2007) · The Journal of Neuroscience · doi:10.1523/jneurosci.1486-07.2007 · Cited by 235
Self-citationMacefield, V., H�ger-Ross, C., & Johansson, R. (1996) · Experimental Brain Research · doi:10.1007/bf00242913 · Cited by 230
A brain-machine interface instructed by direct intracortical microstimulation
O'Doherty, J. E. (2009) · Frontiers in Integrative Neuroscience · doi:10.3389/neuro.07.020.2009 · Cited by 172
The representation of stimulus orientation in the early stages of somatosensory processing
Bensmaia, S. J., Denchev, P. V., Dammann, J. F., Craig, J. C., & Hsiao, S. S. (2008) · The Journal of Neuroscience · doi:10.1523/jneurosci.4162-07.2008 · Cited by 162 · cited 1×
“These temporally precise responses are relatively insensitive to object properties (14) and critical in guiding the dexterous manipulation of objects (9).”
BackgroundSelf-citationVisuotopic Mapping Through a Multichannel Stimulating Implant in Primate V1
Bradley, D. C., Troyk, P. R., Berg, J. A., Bak, M., Cogan, S., Erickson, R., Kufta, C., Mascaro, M., McCreery, D., Schmidt, E. M., et al. (2005) · Journal of Neurophysiology · doi:10.1152/jn.01213.2003 · Cited by 152
Self-citationSENSORY SIGNALS IN NEURAL POPULATIONS UNDERLYING TACTILE PERCEPTION AND MANIPULATION
Goodwin, A. W., & Wheat, H. E. (2004) · Annual Review of Neuroscience · doi:10.1146/annurev.neuro.26.041002.131032 · Cited by 141
Electrical Stimulation of the Proprioceptive Cortex (Area 3a) Used to Instruct a Behaving Monkey
London, B. M., Jordan, L. R., Jackson, C. R., & Miller, L. E. (2008) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.907544 · Cited by 124 · cited 1×
“IEEE Trans Neural Syst Rehabil Eng 19(5):468–476.”
Behavioral Demonstration of a Somatosensory Neuroprosthesis
Berg, J. A., Dammann, J. F., Tenore, F. V., Tabot, G. A., Boback, J. L., Manfredi, L. R., Peterson, M. L., Katyal, K. D., Johannes, M. S., Makhlin, A., et al. (2013) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2244616 · Cited by 119
Self-citationShape Invariant Coding of Motion Direction in Somatosensory Cortex
Pei, Y.-C., Hsiao, S. S., Craig, J. C., & Bensmaia, S. J. (2010) · PLoS Biology · doi:10.1371/journal.pbio.1000305 · Cited by 105 · cited 1×
“In experiments with electrode drives, it has been shown that the distal digit representations in area 1 are at the surface, whereas the distal digit representations in area 3b are ∼3 mm deep (36).”
MethodConvergence of submodality-specific input onto neurons in primary somatosensory cortex
Pei, Y.-C., Denchev, P. V., Hsiao, S. S., Craig, J. C., & Bensmaia, S. J. (2009) · Journal of Neurophysiology · doi:10.1152/jn.00235.2009 · Cited by 102 · cited 3×
“Thus, the slowly varying pressure-related feedback described above can be complemented by phasic ICMS pulse trains at the onset and offset of contact to signal the timing of contact events, thereby mimicking the natural on and off responses of S1 neurons (13).”
BackgroundInfluentialRicher, F., Martinez, M. E. D. Q., Robert, M., Bouvier, G., & Saint-Hilaire, J. M. (1993) · Experimental Brain Research · doi:10.1007/bf00227792 · Cited by 96 · cited 2×
“We found most thresholds (defined as 75% correct performance on the detection task) ranged from 20 to 40 μA, with no differences across areas [two-way ANOVA: F(1,55) = 0.”
BackgroundPhosphene induction and the generation of saccadic eye movements by striate cortex
Tehovnik, E. J., Slocum, W. M., Carvey, C. E., & Schiller, P. H. (2005) · Journal of Neurophysiology · doi:10.1152/jn.00736.2004 · Cited by 87
Wheat, H., Goodwin, A., & Browning, A. (1995) · The Journal of Neuroscience · doi:10.1523/jneurosci.15-08-05582.1995 · Cited by 80 · cited 1×
“Indeed, signals from mechanoreceptive afferents in the skin convey information about the location of contact (19, 20) and about the forces exerted on the skin when an object is grasped (21–25).”
BackgroundDetection psychophysics of intracortical microstimulation in rat primary somatosensory cortex
Butovas, S., & Schwarz, C. (2007) · European Journal of Neuroscience · doi:10.1111/j.1460-9568.2007.05449.x · Cited by 70
Amplitude-dependency of response of SI cortex to flutter stimulation
Simons, S. B., Tannan, V., Chiu, J. S., Favorov, O. V., Whitsel, B. L., & Tommerdahl, M. (2005) · BMC Neuroscience · doi:10.1186/1471-2202-6-43 · Cited by 62 · cited 1×
“The neural coding of contact pressure might rely on two mechanisms: (i) as the pressure exerted on the skin increases, the neuronal population with RFs under the stimulus becomes more active, and (ii) neurons with adjacent RFs will become activated so the size of the activated population will increase (11).”
BackgroundPons, T. P., Garraghty, P. E., Cusick, C. G., & Kaas, J. H. (1985) · Brain Research · doi:10.1016/0006-8993(85)90492-5 · Cited by 60 · cited 1×
“All three animals yielded maps consistent with previous studies, with a progression from D5 (small finger) to D1 (thumb) proceeding laterally and anteriorly along the central sulcus (37).”
MethodPurification of the substance which is responsible for the vasoconstrictor activity of serum.
Rapport, M. M., Green, A. A., & PAGE, I. H. (1947) · PubMed · Cited by 57
Schiller, P. H., Slocum, W. M., Kwak, M. C., Kendall, G. L., & Tehovnik, E. J. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1108337108 · Cited by 54 · cited 1×
“A it has been shown that percepts can be elicited with intracortical microstimulation (ICMS) of primary somatosensory cortex (S1) (1–7), a major challenge in developing approaches to convey sensory feedback using ICMS in animal models is to assay the evoked sensations (8).”
Background(1947) · PubMed · Cited by 54
Kim, S. S., Sripati, A. P., Vogelstein, R. J., Armiger, R. S., Russell, A. F., & Bensmaia, S. J. (2009) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2009.2032396 · Cited by 49
Self-citationAsymmetric Versus Symmetric Pulses for Cortical Microstimulation
Koivuniemi, A. S., & Otto, K. J. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2166563 · Cited by 43 · cited 1×
“(Lower Inset) Structure of ICMS, which consisted of 300-Hz trains of symmetric biphasic pulses (phase duration = 200 μs, interphase duration = 53 μs) (38) lasting 1 s unless otherwise specified.”
MethodNon-effect of hysterectomy on the ovary.
RANNEY, B., Peckham, B. M., & Greene, R. R. (1947) · PubMed · Cited by 6
Research works printed but not linked: 2
- C Blabe, et al., Assessing brain-machine interface priorities from the perspective of spinal cord injury participants. Society for Neuroscience. Soc Neurosci, in press. (2012).
- Johannes MS et al. (2011) An overview of the developmental process for the Modular Prosthetic Limb. The Johns Hopkins University Applied Physics Laboratory Technical Digest 30(3):207–216.
Cited by
Pursuing prosthetic electronic skin
Chortos, A., Liu, J., & Bao, Z. (2016) · Nature Materials · doi:10.1038/nmat4671 · Cited by 2,396
Optoelectronically innervated soft prosthetic hand via stretchable optical waveguides
Zhao, H., O’Brien, K., Li, S., & Shepherd, R. F. (2016) · Science Robotics · doi:10.1126/scirobotics.aai7529 · Cited by 982
Intracortical microstimulation of human somatosensory cortex
Flesher, S. N., Collinger, J. L., Foldes, S. T., Weiss, J. M., Downey, J. E., Tyler-Kabara, E. C., Bensmaia, S. J., Schwartz, A. B., Boninger, M. L., & Gaunt, R. A. (2016) · Science Translational Medicine · doi:10.1126/scitranslmed.aaf8083 · Cited by 704
Brain-Machine Interfaces: From Basic Science to Neuroprostheses and Neurorehabilitation
Lebedev, M. A., & Nicolelis, M. A. L. (2017) · Physiological Reviews · doi:10.1152/physrev.00027.2016 · Cited by 653
“(784) asked if sensations from different skin locations could be evoked using ICMS.”
BackgroundWireless power transfer to deep-tissue microimplants
Ho, J. S., Yeh, A. J., Neofytou, E., Kim, S., Tanabe, Y., Patlolla, B., Beygui, R. E., & Poon, A. S. Y. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1403002111 · Cited by 541
“Though well-suited for large devices and prostheses (21, 22), near-field methods do not address key challenges to powering a microimplant: weak coupling between extremely asymmetric source and receiver structures (23), dissipative and heterogeneous tissue (24), and regulatory power thresholds for general safety (25).”
Background
Metadata
- Authors
- Tabot, G. A., Dammann, J. F., Berg, J. A., Tenore, F. V., Boback, J. L., Vogelstein, R. J., & Bensmaia, S. J.
- Affiliations
- Committee on Computational Neuroscience and
- University of Chicago (US)
- Johns Hopkins University (US)
- Venue
- Proceedings of the National Academy of Sciences
- Publisher
- National Academy of Sciences
- Published
- 2013-10-14
- Volume
- 110
- Issue
- 45
- Pages
- 18279-18284
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- PMC
- PMC3831459
- OpenAlex
- W2030363736
- Cited by
- 320
- References
- 39
- Citations by year
- 2026: 9 · 2025: 13 · 2024: 17 · 2023: 26 · 2022: 24 · 2021: 27 · 2020: 27 · 2019: 33 · 2018: 28 · 2017: 23 · 2016: 45 · 2015: 23 · 2014: 22 · 2013: 2
- FWCI
- 15.04
- Type
- journal article
- Language
- en
- Update notices
- correction (2013-12-27)
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Proceedings of the National Academy of Sciences (publishedVersion)
- Europe PMC (PubMed Central) (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Johns Hopkins University
- National Research Foundation of Korea
- National Institute of Neurological Disorders and Stroke (NS 082865, R01NS18787, R01NS082865, R01NS018787)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Life Sciences › Neuroscience › Cognitive Neuroscience › Tactile and Sensory Interactions
- Keywords
- prosthetic hand, brain-computer interface, intracortical microstimulation, somatosensory feedback, primary somatosensory cortex, tactile perception, pressure sensation, tetraplegia, amputation, non-human primates, tactile discrimination, embodiment
- MeSH terms
- Afferent Pathways, Animals, Artificial Limbs, Brain Mapping, Electric Stimulation, Feedback, Hand, Humans, Macaca mulatta, Pressure, Somatosensory Cortex, Time Factors, Touch, Biomimetics, Brain-Computer Interfaces
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.