CoChat
Cited by 182

The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.

Pencil–paper on-skin electronics

Open access
Xu, Yadong, Zhao, Ganggang, Zhu, Liang, Fei, Qihui, Zhang, Zhe, Chen, Zanyu, An, Fufei, Chen, Yangyang, Ling, Yun, Guo, Peijun, Ding, Shinghua, Huang, Guoliang, Chen, Pai-Yen, Cao, Qing, Yan, Zheng · 2020 · Proceedings of the National Academy of Sciences

Abstract

Significance: On-skin electronics are usually fabricated by patterning conventional inorganic materials, novel organic materials, or emerging nanomaterials on flexible polymer substrates. Consequently, the state-of-the-art on-skin electronics usually suffer from expensive precursor materials, costly fabrication facilities, complex fabrication processes, and limited disposability. By using widely accessible pencils and papers as tools, we have developed a variety of cost-effective and disposable on-skin electronic devices, ranging from biophysical sensors and sweat biochemical sensors to thermal stimulators, humidity energy harvesters, and transdermal drug-delivery systems. Also, pencil–paper-based antennas, two-dimensional and three-dimensional circuits, and reconfigurable structures are demonstrated. The enabled devices can find wide applications particularly in low-resource environments and home-centered personal healthcare owing to their low-cost resources, handy operation, time-saving fabrication, and abundant potential designs.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1073/pnas.2008422117

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Figures

Fig. 1 Pencil drawing of on-skin electronics on papers. ( A ) Conceptual illustrations of drawing on-skin electronics on papers using a 9B sketching pencil. ( B ) A photograph of pencil -paper on-skin electronics. ( C ) SEM images of pencil-drawn graphite on papers. Arrows indicate the multilayer structures and edges of graphitic flakes. ( D ) Raman spectrum of pencil-drawn graphite on papers. ( E ) Variations in the sheet resistance of pencil-drawn graphite on papers as a function of writing cycles. Error bars represent the SDs of three individual samples. ( F ) Schematic of a planar dipole antenna based on the multilayered structure of pencil-drawn graphite and paper. ( G ) Reflection (S11) spectra for the pencil -paper-based dipole antenna with different numbers of stacked layers (5G midband). ( H and I ) Simulated 3D ( H ) and simulated and measured 2D ( I ) radiation patterns for the pencil -paper-based dipole antenna (12 layers) working at 2.3 GHz. In G and I solid and dashed lines represent the measurement and simulation results, respectively. ( J and K ) Variations in the electrical resistance of pencil-drawn graphite as a function of bending radius ( J ) and tensile strain ( K ). ( L ) Peel -adhesion tests of pristine papers (blue) and papers with spray-coated Silbione (red) on the forearm of a human volunteer, indicating the significantly enhanced adhesion after Silbione coating. The sample size is 1.5 3 4 cm 2 . ( M ) Water vapor transmissions (WVT) of pristine papers (blue) and papers coated with Silbione (red) as a function of the elapsed time.
Fig. 1 Pencil drawing of on-skin electronics on papers. ( A ) Conceptual illustrations of drawing on-skin electronics on papers using a 9B sketching pencil. ( B ) A photograph of pencil -paper on-skin electronics. ( C ) SEM images of pencil-drawn graphite on papers. Arrows indicate the multilayer structures and edges of graphitic flakes. ( D ) Raman spectrum of pencil-drawn graphite on papers. ( E ) Variations in the sheet resistance of pencil-drawn graphite on papers as a function of writing cycles. Error bars represent the SDs of three individual samples. ( F ) Schematic of a planar dipole antenna based on the multilayered structure of pencil-drawn graphite and paper. ( G ) Reflection (S11) spectra for the pencil -paper-based dipole antenna with different numbers of stacked layers (5G midband). ( H and I ) Simulated 3D ( H ) and simulated and measured 2D ( I ) radiation patterns for the pencil -paper-based dipole antenna (12 layers) working at 2.3 GHz. In G and I solid and dashed lines represent the measurement and simulation results, respectively. ( J and K ) Variations in the electrical resistance of pencil-drawn graphite as a function of bending radius ( J ) and tensile strain ( K ). ( L ) Peel -adhesion tests of pristine papers (blue) and papers with spray-coated Silbione (red) on the forearm of a human volunteer, indicating the significantly enhanced adhesion after Silbione coating. The sample size is 1.5 3 4 cm 2 . ( M ) Water vapor transmissions (WVT) of pristine papers (blue) and papers coated with Silbione (red) as a function of the elapsed time.From the PDF
Fig. 2 On-body evaluations of pencil -paper on-skin biophysical sensors and thermal stimulators. ( A and B ) Dynamic electrical responses of the pencil -paper on-skin temperature sensor on a hotplate with various fixed temperatures ( A ) and upon contact and removal from the human skin ( B ). ( C ) Temperature -time profiles of the pencil -paper on-skin joule-heating element with applied voltages of 10, 20, 30, and 40 V. ( D ) Infrared thermal camera images of the pencil -paper on-skin joule-heating element laminated on the wrist of a human volunteer with an applied voltage of 15 V. ( E ) Impedances of the skin -electrode interface of pencil-drawn graphite electrodes and conventional Ag/AgCl electrodes, measured from the forearm of a human volunteer. ( F ) Long-term ECG recording from the chest of a human volunteer using the pencil -paper on-skin electrophysiological sensor, indicating high stability. ( G ) Dynamic amplitude responses of the R peaks in the ECG signals while the volunteer held the breath for ∼ 25 s. ( H ) Respiratory rates determined by the R peak amplitude variations in G and visual counting by a physician. ( I ) Comparisons of instantaneous heart rates determined from the R-to-R peak intervals in the ECG signals recorded with pencil -paper on-skin sensors and conventional Ag/AgCl electrodes. ( J ) EMG signals recorded from the forearm of a human volunteer with the pencil -paper on-skin sensor.
Fig. 2 On-body evaluations of pencil -paper on-skin biophysical sensors and thermal stimulators. ( A and B ) Dynamic electrical responses of the pencil -paper on-skin temperature sensor on a hotplate with various fixed temperatures ( A ) and upon contact and removal from the human skin ( B ). ( C ) Temperature -time profiles of the pencil -paper on-skin joule-heating element with applied voltages of 10, 20, 30, and 40 V. ( D ) Infrared thermal camera images of the pencil -paper on-skin joule-heating element laminated on the wrist of a human volunteer with an applied voltage of 15 V. ( E ) Impedances of the skin -electrode interface of pencil-drawn graphite electrodes and conventional Ag/AgCl electrodes, measured from the forearm of a human volunteer. ( F ) Long-term ECG recording from the chest of a human volunteer using the pencil -paper on-skin electrophysiological sensor, indicating high stability. ( G ) Dynamic amplitude responses of the R peaks in the ECG signals while the volunteer held the breath for ∼ 25 s. ( H ) Respiratory rates determined by the R peak amplitude variations in G and visual counting by a physician. ( I ) Comparisons of instantaneous heart rates determined from the R-to-R peak intervals in the ECG signals recorded with pencil -paper on-skin sensors and conventional Ag/AgCl electrodes. ( J ) EMG signals recorded from the forearm of a human volunteer with the pencil -paper on-skin sensor.From the PDF
Fig. 3 Monitoring of cerebral activities via real-time EEG recording. ( A and B ) Schematics ( A ) and recorded EEG signals ( B ) using pencil -paper on-skin electrophysiological sensors when a human volunteer engaged in three mental states. ( C ) FFT-processed frequency distributions of the EEG signals in B . ( D ) Time -frequency spectrograms of the EEG signals within beta band (13 -38 Hz) during three mental states ( Left : closed eyes; Middle : twilight state; Right : math calculation), showing significantly higher signal intensities during math calculation.
Fig. 3 Monitoring of cerebral activities via real-time EEG recording. ( A and B ) Schematics ( A ) and recorded EEG signals ( B ) using pencil -paper on-skin electrophysiological sensors when a human volunteer engaged in three mental states. ( C ) FFT-processed frequency distributions of the EEG signals in B . ( D ) Time -frequency spectrograms of the EEG signals within beta band (13 -38 Hz) during three mental states ( Left : closed eyes; Middle : twilight state; Right : math calculation), showing significantly higher signal intensities during math calculation.From the PDF
Fig. 4 Characterizations and perspiration analysis of pencil -paper-based pH, UA, and glucose sensors. ( A ) Schematic illustrations of pencil -paper-based sweat biochemical sensors for in situ measurement of pH, UA, and glucose in sweat. CE: counter electrode; WE: working electrode; RE: reference electrode. ( B ) Dynamic OCP responses to pH variations. ( C ) Calibration plot of the pH sensor. ( D and E ) DPV responses ( D ) and calibration plot ( E ) of the UA sensor over the concentration range of 0 -600 μ Min a 0.1 M phosphate buffer solution (pH 7.2). ( F ) Selectivity test of the UA sensor. ( G and H ) Dynamic current responses to glucose concentration variations ( G ) and calibration plot ( H ) of the glucose sensor. ( I ) Selectivity test of the glucose sensor. ( J ) Comparisons of the data measured with pencil -paper-based biochemical sensors and the results obtained with the conventional methods. ( K ) Dynamic change of the UA concentrations, recorded by pencil -paper-based UA sensors, before and after a purine-rich diet over a 9-h period.
Fig. 4 Characterizations and perspiration analysis of pencil -paper-based pH, UA, and glucose sensors. ( A ) Schematic illustrations of pencil -paper-based sweat biochemical sensors for in situ measurement of pH, UA, and glucose in sweat. CE: counter electrode; WE: working electrode; RE: reference electrode. ( B ) Dynamic OCP responses to pH variations. ( C ) Calibration plot of the pH sensor. ( D and E ) DPV responses ( D ) and calibration plot ( E ) of the UA sensor over the concentration range of 0 -600 μ Min a 0.1 M phosphate buffer solution (pH 7.2). ( F ) Selectivity test of the UA sensor. ( G and H ) Dynamic current responses to glucose concentration variations ( G ) and calibration plot ( H ) of the glucose sensor. ( I ) Selectivity test of the glucose sensor. ( J ) Comparisons of the data measured with pencil -paper-based biochemical sensors and the results obtained with the conventional methods. ( K ) Dynamic change of the UA concentrations, recorded by pencil -paper-based UA sensors, before and after a purine-rich diet over a 9-h period.From the PDF
Fig. 5 Characterization of pencil -paper-based humidity energy harvesters and demonstration of self-powered on-skin transdermal drug-delivery systems. ( A ) Schematic illustrations of humidity energy harvesters, enabled by creating a gradient of oxygen-containing groups on cellulose papers between interdigital pencil-drawn graphite electrodes via a moisture -electric polarization process. ( B ) High-resolution C 1s XPS spectra of the polarized cellulose paper near the cathode ( Left ) and the anode ( Right ), which can be deconvoluted into three subpeaks, representing C -C, C = O, and C -O bonds, respectively. ( C ) Line-scan EDS of the polarized cellulose paper between two pencil-drawn graphite electrodes, showing an increased oxygen atomic ratio from the cathode to the anode. ( D ) Dynamic responses of the open-circuit voltage of energy harvesters exposed to a relative humidity of ∼ 95% as a function of the elapsed time. ( E ) Correlations of the output voltage and environmental humidity. ( F ) Output voltages and output currents of energy harvesters connected with external resistors with different resistances. ( Inset ) Circuit layout used for testing. ( G ) Electrical performances of energy-harvester units connected in series (red) and in parallel (green). ( H ) Dynamic responses of the output voltage to intermittent and periodic humidity variations, showing high cyclic stability and self-charging capability. ( I ) Output voltages of 10 randomly selected devices with a mean of 478.6 mV and an SD of 27.7 mV, demonstrating high reproducibility. ( J ) Schematic of a self-powered on-skin transdermal drug-delivery system. ( K ) Cross-sectional fluorescent images of pig skins without ( Left ) and with ( Right ) iontophoresis. (Scale bars, 200 μ m.)
Fig. 5 Characterization of pencil -paper-based humidity energy harvesters and demonstration of self-powered on-skin transdermal drug-delivery systems. ( A ) Schematic illustrations of humidity energy harvesters, enabled by creating a gradient of oxygen-containing groups on cellulose papers between interdigital pencil-drawn graphite electrodes via a moisture -electric polarization process. ( B ) High-resolution C 1s XPS spectra of the polarized cellulose paper near the cathode ( Left ) and the anode ( Right ), which can be deconvoluted into three subpeaks, representing C -C, C = O, and C -O bonds, respectively. ( C ) Line-scan EDS of the polarized cellulose paper between two pencil-drawn graphite electrodes, showing an increased oxygen atomic ratio from the cathode to the anode. ( D ) Dynamic responses of the open-circuit voltage of energy harvesters exposed to a relative humidity of ∼ 95% as a function of the elapsed time. ( E ) Correlations of the output voltage and environmental humidity. ( F ) Output voltages and output currents of energy harvesters connected with external resistors with different resistances. ( Inset ) Circuit layout used for testing. ( G ) Electrical performances of energy-harvester units connected in series (red) and in parallel (green). ( H ) Dynamic responses of the output voltage to intermittent and periodic humidity variations, showing high cyclic stability and self-charging capability. ( I ) Output voltages of 10 randomly selected devices with a mean of 478.6 mV and an SD of 27.7 mV, demonstrating high reproducibility. ( J ) Schematic of a self-powered on-skin transdermal drug-delivery system. ( K ) Cross-sectional fluorescent images of pig skins without ( Left ) and with ( Right ) iontophoresis. (Scale bars, 200 μ m.)From the PDF

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 30

  1. 10.1039/C8CS00814K · DOI · Paper page
  2. 10.1002/adma.201902417 · DOI
  3. 10.1021/acs.accounts.8b00500 · DOI · Paper page
  4. 10.1002/adma.201902743 · DOI · Paper page
  5. 10.1038/s41587-019-0079-1 · DOI · Paper page
  6. 10.1038/s41467-019-10569-3 · DOI · Paper page
  7. 10.1038/nmat4904 · DOI · Paper page
  8. 10.1126/sciadv.aaq0508 · DOI · Paper page
  9. 10.1021/acs.accounts.7b00548 · DOI · Paper page
  10. 10.1002/adma.201004692 · DOI · Paper page
  11. 10.1039/c1ee01853a · DOI · Paper page
  12. 10.1002/adfm.201500094 · DOI · Paper page
  13. 10.1016/j.physrep.2009.02.003 · DOI · Paper page
  14. 10.1109/TAP.2005.846784 · doi:10.1109/tap.2005.846784
  15. 10.1109/RFID.2009.4911205 · doi:10.1109/rfid.2009.4911205
  16. 10.1109/LAWP.2013.2287307 · doi:10.1109/lawp.2013.2287307
  17. 10.1126/sciadv.aau0920 · DOI · Paper page
  18. 10.1038/nmat4327 · DOI · Paper page
  19. 10.1073/pnas.1917762116 · DOI · Paper page
  20. 10.1002/adma.201804327 · DOI · Paper page
  21. 10.1016/j.jddst.2018.01.022 · DOI
  22. 10.1002/adma.201908475 · DOI · Paper page
  23. 10.1007/978-3-540-36841-0_1030 · DOI
  24. 10.1586/14737175.2015.1025382 · DOI
  25. K. G. Jordan, Emergency EEG and continuous EEG monitoring in acute ischemic stroke. J. Clin. Neurophysiol. 21, 341–352 (2004).
  26. 10.1016/j.neubiorev.2012.10.003 · DOI · Paper page
  27. 10.3390/s130810273 · DOI · Paper page
  28. 10.1002/adfm.201900025 · DOI
  29. 10.1002/adma.201805705 · DOI · Paper page
  30. 10.1039/C9EE00252A · DOI · Paper page

Cited by

See all 182

Metadata

Authors
Xu, Y., Zhao, G., Zhu, L., Fei, Q., Zhang, Z., Chen, Z., An, F., Chen, Y., Ling, Y., Guo, P., Ding, S., Huang, G., Chen, P.-Y., Cao, Q., & Yan, Z.
Venue
Proceedings of the National Academy of Sciences
Published
2020-07-13
Volume
117
Issue
31
Pages
18292-18301
ISSN
  • 0027-8424 (ISSN-L)
  • 1091-6490
OpenAlex
W3041700374
Cited by
182
References
11
FWCI
8.26
Type
journal article
Language
en
Open access
green
Funders
  • NSF (ECCS 1914420: CAREER)
  • Air Force (AF 9550-18-1-0342)
  • NIH (R01NS069726 and R01NS094539)

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.