The validity and inter-device variability of the Apple Watch™ for measuring maximal heart rate
Open accessAbstract
Maximal heart rate (HRmax) is a fundamental measure used in exercise prescription. The Apple Watch™ measures heart rate yet the validity and inter-device variability of the device for measuring HRmax are unknown. Fifteen participants completed a maximal oxygen uptake test while wearing an Apple Watch™ on each wrist. Criterion HRmax was measured using a Polar T31™ chest strap. There were good to very good correlations between the watches and criterion (left: r = 0.87 [90%CI: 0.67 to 0.95]; right: r = 0.98 [90%CI: 0.94 to 0.99]). Standardised mean bias for the left and right watches compared to the criterion were 0.14 (90%CI: −0.12 to 0.39; trivial) and 0.04 (90%CI: −0.07 to 0.15; trivial). Standardised typical error of the estimate for the left and right watches compared to the criterion were 0.51 (90%CI: 0.38 to 0.80; moderate) and 0.22 (90%CI: 0.16 to 0.34; small). Inter-device standardised typical error was 0.46 (90%CI: 0.36 to 0.68; moderate), ICC = 0.84 (90%CI: 0.65 to 0.93). The Apple Watch™ has good to very good criterion validity for measuring HRmax, with no substantial under- or over-estimation. There were moderate and small prediction errors for the left and right watches. Inter-device variability in HRmax is moderate.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Similar standard typical error levels were seen in maximum heart rate measured during a single incremental maximal oxygen uptake test and heart rate taken from the highest 30-s mean heart rate, with somewhat lower correlation coefficients [24].
“Similar standard typical error levels were seen in maximum heart rate measured during a single incremental maximal oxygen uptake test performed on a treadmill and heart rate taken from the highest 30-s mean heart rate, with somewhat lower correlation coefficients [24].”
From Reliability and Validity of Commercially Available Wearable Devices for Measuring Steps, Energy Expenditure, and Heart Rate: Systematic Review (2020) · cites this paper as [24]
Three studies (23 comparisons) examined interdevice reliability for heart rate, with analyzed sample sizes ranging from 13 to 21.
“Three studies (23 comparisons) examined interdevice reliability for heart rate [24,26,58], with analyzed sample sizes ranging from 13 [24] to 21 [26].”
From Reliability and Validity of Commercially Available Wearable Devices for Measuring Steps, Energy Expenditure, and Heart Rate: Systematic Review (2020) · cites this paper as [24]
Cites
(2014) · Medical Entomology and Zoology · Cited by 9,400 · see citing works
Photoplethysmography and its application in clinical physiological measurement
Allen, J. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/3/r01 · Cited by 3,967 · see citing works
Criteria for maximal oxygen uptake: review and commentary
HOWLEY, E. T., BASSETT, D. R., & WELCH, H. G. (1995) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-199509000-00009 · Cited by 1,656 · see citing works
Achten, J., & Jeukendrup, A. E. (2003) · Sports Medicine · doi:10.2165/00007256-200333070-00004 · Cited by 1,202 · see citing works
Hamine, S., Gerth-Guyette, E., Faulx, D., Green, B. B., & Ginsburg, A. S. (2015) · Journal of Medical Internet Research · doi:10.2196/jmir.3951 · Cited by 1,149 · see citing works
Longitudinal Modeling of the Relationship between Age and Maximal Heart Rate
GELLISH, R. L., GOSLIN, B. R., OLSON, R. E., McDONALD, A., RUSSI, G. D., & MOUDGIL, V. K. (2007) · Medicine & Science in Sports & Exercise · doi:10.1097/mss.0b013e31803349c6 · Cited by 660 · see citing works
Lyons, E. J., Lewis, Z. H., Mayrsohn, B. G., & Rowland, J. L. (2014) · Journal of Medical Internet Research · doi:10.2196/jmir.3469 · Cited by 547 · cited 1× · see citing works
“Unlike measuring HR manually, both the Polar T31TM HR strap and the Apple WatchTM enable continuous and immediate feedback of HR during exercise, which has the potential to enhance self-regulation, exercise safety and motivation (Lyons et al., 2014).”
MethodPhysiological tests for elite athletes
Gore, C. J. (2000) · Cited by 524 · see citing works
THE BLOOD SUPPLY OF VARIOUS SKIN AREAS AS ESTIMATED BY THE PHOTOELECTRIC PLETHYSMOGRAPH
Hertzman, A. B. (1938) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1938.124.2.328 · Cited by 455 · see citing works
Price, K. J., Gordon, B. A., Bird, S. R., & Benson, A. C. (2016) · European Journal of Preventive Cardiology · doi:10.1177/2047487316657669 · Cited by 408 · see citing works
Self-citationAccuracy of wrist-worn heart rate monitors
Wang, R., Blackburn, G., Desai, M., Phelan, D., Gillinov, L., Houghtaling, P., & Gillinov, M. (2017) · JAMA Cardiology · doi:10.1001/jamacardio.2016.3340 · Cited by 386 · see citing works
Accuracy of Heart Rate Watches: Implications for Weight Management
Wallen, M. P., Gomersall, S. R., Keating, S. E., Wisløff, U., & Coombes, J. S. (2016) · PLOS ONE · doi:10.1371/journal.pone.0154420 · Cited by 336 · see citing works
(2002) · QUT ePrints (Queensland University of Technology) · Cited by 282 · see citing works
Flagged first, then by citations
1 of the 14 references couldn’t be matched to a known paper.
Cited by
Sorted by citations
Bio-Integrated Wearable Systems: A Comprehensive Review
Ray, T. R., Choi, J., Bandodkar, A. J., Krishnan, S., Gutruf, P., Tian, L., Ghaffari, R., & Rogers, J. A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00573 · Cited by 1,350 · see citing works
Fuller, D., Colwell, E., Low, J., Orychock, K., Tobin, M. A., Simango, B., Buote, R., Van Heerden, D., Luan, H., Cullen, K., et al. (2020) · JMIR mHealth and uHealth · doi:10.2196/18694 · Cited by 715 · see citing works
Tissue adhesive hydrogel bioelectronics
Li, S., Cong, Y., & Fu, J. (2021) · Journal of Materials Chemistry B · doi:10.1039/d1tb00523e · Cited by 260 · see citing works
Hernando, D., Roca, S., Sancho, J., Alesanco, Á., & Bailón, R. (2018) · Sensors · doi:10.3390/s18082619 · Cited by 225 · see citing works
Li, X., Zeng, X., Xia, F., Jin, W., Liu, Y., & Hu, Y. (2020) · ACS Nano · doi:10.1021/acsnano.0c01164 · Cited by 139 · see citing works
Mühlen, J. M., Stang, J. S., Skovgaard, E. L., Júdice, P. B., Molina‐García, P., Johnston, W., Sardinha, L. B., Ortega, F. B., Caulfield, B., Bloch, W., et al. (2021) · British Journal of Sports Medicine · doi:10.1136/bjsports-2020-103148 · Cited by 118 · see citing works
Zhang, Y., Weaver, R. G., Armstrong, B., Burkart, S., Zhang, S., & Beets, M. W. (2020) · Journal of Sports Sciences · doi:10.1080/02640414.2020.1767348 · Cited by 88 · see citing works
Measurement of Pulse Wave Signals and Blood Pressure by a Plastic Optical Fiber FBG Sensor
Haseda, Y., Bonefacino, J., Tam, H., Chino, S., Koyama, S., & Ishizawa, H. (2019) · Sensors · doi:10.3390/s19235088 · Cited by 87 · see citing works
Al‐Qatatsheh, A., Morsi, Y., Zavabeti, A., Zolfagharian, A., Salim, N. V., Kouzani, A. Z., Mosadegh, B., & Gharaie, S. (2020) · Sensors · doi:10.3390/s20164484 · Cited by 68 · see citing works
The Apple Watch for Monitoring Mental Health–Related Physiological Symptoms: Literature Review
Lui, G. Y., Loughnane, D. C., Polley, C., Jayarathna, T., & Breen, P. P. (2022) · JMIR Mental Health · doi:10.2196/37354 · Cited by 65 · see citing works
Validation of a Photoplethysmographic Heart Rate Monitor: Polar OH1
Hermand, E., Cassirame, J., Ennequin, G., & Hue, O. (2019) · International Journal of Sports Medicine · doi:10.1055/a-0875-4033 · Cited by 59 · see citing works
In-Ear Pulse Rate Measurement: A Valid Alternative to Heart Rate Derived from Electrocardiography?
Passler, S., Müller, N., & Senner, V. (2019) · Sensors · doi:10.3390/s19173641 · Cited by 55 · see citing works
The Polar® OH1 Optical Heart Rate Sensor is Valid during Moderate-Vigorous Exercise
Schubert, M. M., Clark, A., & Rosa, A. B. D. L. (2018) · Sports Medicine International Open · doi:10.1055/a-0631-0920 · Cited by 47 · see citing works
Nuske, H. J., Goodwin, M. S., Kushleyeva, Y., Forsyth, D., Pennington, J. W., Masino, A. J., Finkel, E., Bhattacharya, A., Tan, J., Tai, H., et al. (2021) · Autism Research · doi:10.1002/aur.2633 · Cited by 28 · see citing works
Wearable Smart Bandage-Based Bio-Sensors
Levin, A., Gong, S. P., & Cheng, W. (2023) · Biosensors · doi:10.3390/bios13040462 · Cited by 29 · see citing works
The marriage of biochemistry and nanotechnology for non-invasive real-time health monitoring
Ji, D., Guo, X., Fu, W., Ding, Z., Wang, C., Zhang, Q., Ramakrishna, S., & Qin, X. (2022) · Materials Science and Engineering R Reports · doi:10.1016/j.mser.2022.100681 · Cited by 27 · see citing works
Accuracy of the Apple Watch Oxygen Saturation Measurement in Adults: A Systematic Review
Windisch, P. Y., Schröder, C., Forster, R. E., Čihorić, N., & Zwahlen, D. R. (2023) · Cureus · doi:10.7759/cureus.35355 · Cited by 23 · see citing works
Measuring Moderate-Intensity Exercise with the Apple Watch: Validation Study
Abt, G., Bray, J., & Benson, A. C. (2018) · JMIR Cardio · doi:10.2196/cardio.8574 · Cited by 21 · see citing works
Self-citationNagwade, P., Parandeh, S., & Lee, S. (2023) · Soft Science · doi:10.20517/ss.2023.12 · Cited by 19 · see citing works
Validity of the Polar Vantage M watch when measuring heart rate at different exercise intensities
Shumate, T., Link, M., Furness, J. W., Kemp‐Smith, K., Simas, V., & Climstein, M. (2021) · PeerJ · doi:10.7717/peerj.10893 · Cited by 18 · see citing works
The accuracy of Apple Watch measurements: a living systematic review and meta-analysis
Lambe, R., Baldwin, M., O’Grady, B., Schumann, M., Caulfield, B., & Doherty, C. (2026) · npj Digital Medicine · doi:10.1038/s41746-025-02238-1 · Cited by 17 · see citing works
Hirten, R. P., Suprun, M., Danieletto, M., Zweig, M., Golden, E., Pyzik, R., Kaur, S., Helmus, D. S., Biello, A., Landell, K., et al. (2023) · JAMIA Open · doi:10.1093/jamiaopen/ooad029 · Cited by 15 · see citing works
Støve, M. P., Holm, R. S., Kjaersgaard, A. S., Duncker, K., Jensen, M. R., & Larsen, B. T. (2020) · Journal of Medical Engineering & Technology · doi:10.1080/03091902.2020.1753836 · Cited by 12 · see citing works
Giggins, O. M., Doyle, J., Smith, S., Crabtree, D. R., & Fraser, M. (2022) · JMIR Formative Research · doi:10.2196/34280 · Cited by 9 · see citing works
Apple watch accuracy in monitoring health metrics: a systematic review and meta-analysis
Choe, J.-P., & Kang, M. (2025) · Physiological Measurement · doi:10.1088/1361-6579/adca82 · Cited by 10 · see citing works
Giggins, O. M., Doyle, J., Sojan, N., Moran, O., Crabtree, D. R., Fraser, M., & Muggeridge, D. J. (2021) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc46164.2021.9629522 · Cited by 10 · see citing works
Held, N. J., Perrotta, A. S., Mueller, T., & Pfoh-MacDonald, S. J. (2022) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-022-02536-w · Cited by 7 · see citing works
Thierry, B., Stanley, K. G., Kestens, Y., Winters, M., & Fuller, D. (2023) · American Journal of Epidemiology · doi:10.1093/aje/kwad176 · Cited by 5 · see citing works
Diba, M. A., Sarraf, V. S., Amirsasan, R., & Nikoukheslat, S. D. (2024) · JMIR Research Protocols · doi:10.2196/51599 · Cited by 4 · see citing works
Lu, C. T., Cui, W., Zhu, Z., Wu, Y., Xing, Q., Pan, B., & Shen, Y. (2025) · Frontiers in Physiology · doi:10.3389/fphys.2025.1621996 · Cited by 3 · see citing works
Embodied Computing and the Digital Intimacy of Wearable Technologies
Balfour, L. A. (2023) · Springer eBooks · doi:10.1007/978-3-031-24563-3_5 · Cited by 2 · see citing works
de Leon, M. F., Camic, C. L., Herring, M. J., & Hill, C. M. (2025) · Sports · doi:10.3390/sports13020049 · Cited by 1 · see citing works
Schipper, R. M., Djibrillah, F. O., Roosink, M., Winkens, L. H. H., John, A., Hazebroek, E. J., Witteveen, A., & Berendsen, A. A. M. (2025) · doi:10.2196/preprints.87324 · Cited by 1 · see citing works
Use of Wearable Technology to Measure Emotional Responses Amongst Tennis Players
Azhar, M. A. H. B., Nelson, T., & Casey, A. (2019) · EAI/Springer Innovations in Communication and Computing · doi:10.1007/978-3-030-16130-9_6
Lui, G. Y., Loughnane, D. C., Polley, C., Jayarathna, T., & Breen, P. P. (2022) · doi:10.2196/preprints.37354
Nikoukheslat, S. D., Diba, M. A., Sarraf, V. S., & Amirsasan, R. (2023) · doi:10.2196/preprints.51682
Lara, P. M., Morenas‐Aguilar, M. D., Chacón‐Ventura, S., Jiménez‐Martínez, P., Alix‐Fages, C., García‐Ramos, A., Vera, J., & Redondo, B. (2024) · International Journal of Sport Nutrition and Exercise Metabolism · doi:10.1123/ijsnem.2024-0051 · Cited by 1 · see citing works
Inoue, A., Soares, J. P. F., Antunes-Santos, F., Ferreira, A., Gonçalves, A., Alcântara, J. A., & dos Santos, M. R. (2026) · JMIR Cardio · doi:10.2196/81917
Schipper, R. M., Djibrillah, F. O., Roosink, M., Winkens, L. H. H., John, A., Hazebroek, E. J., Witteveen, A., & Berendsen, A. A. M. (2026) · JMIR mhealth and uhealth · doi:10.2196/87324 · Cited by 1 · see citing works
- Authors
- Abt, G., Bray, J., & Benson, A. C.
- Affiliations
- University of Hull (GB)
- Swinburne University of Technology (AU)
- Corresponding author
- Abt, Grant
- Venue
- Journal of Sports Sciences
- Publisher
- Informa UK Limited
- Published
- 2017-11
- Volume
- 36
- Issue
- 13
- Pages
- 1447-1452
- ISSN
- 0264-0414 (ISSN-L)
- 1466-447X
- OpenAlex
- W2765153122
- Semantic Scholar
- 031f6584ecf502f67467650c869fdb73f41a8ade
- Cited by
- 41
- References
- 14
- Citations by year
- 2026: 3 · 2025: 4 · 2024: 2 · 2023: 8 · 2022: 5 · 2021: 5 · 2020: 5 · 2019: 6 · 2018: 3
- FWCI
- 1.72
- Type
- journal article
- Language
- en
- Open access
- Licence
- cc-by
- Locations
- Journal of Sports Sciences (publishedVersion)
- PubMed (publishedVersion)
- Repository@Hull (Worktribe) (University of Hull) (submittedVersion, cc-by)
- Swinburne figshare (Swinburne University of Technology) (submittedVersion)
- Funders
- No funding
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Complementary and alternative medicine › Cardiovascular and exercise physiology
- Health Sciences › Medicine › Physiology › Physical Activity and Health
- Keywords
- maximal heart rate, Apple Watch, wearable heart rate monitor, criterion validity, inter-device variability, VO2max, exercise prescription
- MeSH terms
- Female, Heart Rate, Humans, Male, Oxygen Consumption, Reproducibility of Results, Exercise, Monitoring, Ambulatory, Mobile Applications
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review