Dispersion and Exposure to a Cough-Generated Aerosol in a Simulated Medical Examination Room
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
Few studies have quantified the dispersion of potentially infectious bioaerosols produced by patients in the health care environment and the exposure of health care workers to these particles. Controlled studies are needed to assess the spread of bioaerosols and the efficacy of different types of respiratory personal protective equipment (PPE) in preventing airborne disease transmission. An environmental chamber was equipped to simulate a patient coughing aerosol particles into a medical examination room, and a health care worker breathing while exposed to these particles. The system has three main parts: (1) a coughing simulator that expels an aerosol-laden cough through a head form; (2) a breathing simulator with a second head form that can be fitted with respiratory PPE; and (3) aerosol particle counters to measure concentrations inside and outside the PPE and at locations throughout the room. Dispersion of aerosol particles with optical diameters from 0.3 to 7.5 μm was evaluated along with the influence of breathing rate, room ventilation, and the locations of the coughing and breathing simulators. Penetration of cough aerosol particles through nine models of surgical masks and respirators placed on the breathing simulator was measured at 32 and 85 L/min flow rates and compared with the results from a standard filter tester. Results show that cough-generated aerosol particles spread rapidly throughout the room, and that within 5 min, a worker anywhere in the room would be exposed to potentially hazardous aerosols. Aerosol exposure is highest with no personal protective equipment, followed by surgical masks, and the least exposure is seen with N95 FFRs. These differences are seen regardless of breathing rate and relative position of the coughing and breathing simulators. These results provide a better understanding of the exposure of workers to cough aerosols from patients and of the relative efficacy of different types of respiratory PPE, and they will assist investigators in providing research-based recommendations for effective respiratory protection strategies in health care settings.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Morawska, L., Johnson, G. R., Ristovski, Z. D., Hargreaves, M., Mengersen, K., Corbett, S., Chao, C. Y. H., Li, Y., & Katoshevski, D. (2009) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2008.11.002 · Cited by 1,129
The role of particle size in aerosolised pathogen transmission: a review
Gralton, J., Tovey, E., McLaws, M.-L., & Rawlinson, W. D. (2011) · Journal of Infection · doi:10.1016/j.jinf.2010.11.010 · Cited by 665 · cited 1×
“(33) Our study was intended to investigate aerosol particles that were large enough to carry pathogens but small enough to remain airborne, and thus, we examined particles over a much smaller size range.”
Measurements of Airborne Influenza Virus in Aerosol Particles from Human Coughs
Lindsley, W. G., Blachere, F. M., Thewlis, R. E., Vishnu, A., Davis, K. A., Cao, G., Palmer, J. E., Clark, K. E., Fisher, M. A., Khakoo, R., et al. (2010) · PLoS ONE · doi:10.1371/journal.pone.0015100 · Cited by 423 · cited 1×
“Cough aerosols from two of these patients contained viable influenza virus.(11) Two air sampling studies have shown that respirable particles containing influenza virus RNA can be found throughout health care facilities,(12,13) and a recent hospital study suggested that small aerosol particles from an influenza patien…”
BackgroundSelf-citationSurgical mask filter and fit performance
Oberg, T., & Brosseau, L. M. (2008) · American Journal of Infection Control · doi:10.1016/j.ajic.2007.07.008 · Cited by 310 · cited 1×
“(5,31,32) On the other hand, our results show that N95 FFRs can protect a worker from the high aerosol concentration within a cough plume impinging directly on the worker, and the steady-state aerosol that accumulates as the cough aerosol spreads throughout the room.”
Bjørn, E., & Nielsen, P. V. (2002) · Indoor Air · doi:10.1034/j.1600-0668.2002.08126.x · Cited by 294 · cited 1×
“In one study, Bjorn et al. (15) placed thermal breathing manikins in a room and determined that exhaled air can form a thermally stratified layer that increases its horizontal dispersion.”
Lee, S.-A., Grinshpun, S. A., & Reponen, T. (2008) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/men005 · Cited by 235 · cited 1×
“(5,31,32) On the other hand, our results show that N95 FFRs can protect a worker from the high aerosol concentration within a cough plume impinging directly on the worker, and the steady-state aerosol that accumulates as the cough aerosol spreads throughout the room.”
Filtration Performance of FDA-Cleared Surgical Masks
Rengasamy*, S., Miller, A., Eimer, B. C., & Shaffer, R. E. (2009) · Journal of the International Society for Respiratory Protection · doi:10.66828/001c.167200 · Cited by 69 · cited 1×
“(4) Further, when surgical masks are actually worn by workers, the protection offered by these devices is reduced even more due to face seal leaks that tend to form around the edges of the mask.”
Cited by
Verbeek, J. H., Rajamaki, B., Ijaz, S., Sauni, R., Toomey, E., Blackwood, B., Tikka, C., Ruotsalainen, J. H., & Kilinc Balci, F. S. (2020) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd011621.pub4 · Cited by 657
Smith, J. D., MacDougall, C. C., Johnstone, J., Copes, R. A., Schwartz, B., & Garber, G. E. (2016) · Canadian Medical Association Journal · doi:10.1503/cmaj.150835 · Cited by 328
Visualizing the effectiveness of face masks in obstructing respiratory jets
Verma, S., Dhanak, M., & Frankenfield, J. (2020) · Physics of Fluids · doi:10.1063/5.0016018 · Cited by 287
Verbeek, J. H., Rajamaki, B., Ijaz, S., Tikka, C., Ruotsalainen, J. H., Edmond, M. B., Sauni, R., & Kilinc Balci, F. S. (2019) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd011621.pub3 · Cited by 276
Zhao, M., Liao, L., Xiao, W., Yu, X., Wang, H., Wang, Q., Lin, Y. L., Kilinc-Balci, F. S., Price, A., Chu, L., et al. (2020) · Nano Letters · doi:10.1021/acs.nanolett.0c02211 · Cited by 266
High Humidity Leads to Loss of Infectious Influenza Virus from Simulated Coughs
Noti, J. D., Blachere, F. M., McMillen, C. M., Lindsley, W. G., Kashon, M. L., Slaughter, D. R., & Beezhold, D. H. (2013) · PLoS ONE · doi:10.1371/journal.pone.0057485 · Cited by 200
“5–4 mm micropump nebulizer (Aerogen, Galway, Ireland) and loaded into the cough simulator remotely for a total of 5 coughs at approximately 1 minute intervals as described [19,20,21].”
BackgroundMethodInfluentialSelf-citationCharlton, C. L., Babady, E., Ginocchio, C. C., Hatchette, T. F., Jerris, R. C., Li, Y., Loeffelholz, M., McCarter, Y. S., Miller, M. B., Novak-Weekley, S., et al. (2018) · Clinical Microbiology Reviews · doi:10.1128/cmr.00042-18 · Cited by 188
“The need for N95 masks can be controversial, and local infection prevention and control procedures should be followed to minimize aerosolization and risk of health care worker infection (144–146).”
BackgroundClassification of aerosol-generating procedures: a rapid systematic review
Jackson, T., Deibert, D., Wyatt, G., Durand-Moreau, Q., Adisesh, A., Khunti, K., Khunti, S., Smith, S., Chan, X. H. S., Ross, L., et al. (2020) · BMJ Open Respiratory Research · doi:10.1136/bmjresp-2020-000730 · Cited by 187
Noti, J. D., Lindsley, W. G., Blachere, F. M., Cao, G., Kashon, M. L., Thewlis, R. E., McMillen, C. M., King, W. P., Szalajda, J. V., & Beezhold, D. H. (2012) · Clinical Infectious Diseases · doi:10.1093/cid/cis237 · Cited by 170
“To address this, Lindsley et al [28] constructed a simulated examination room and showed that coughed aerosol particles of potassium chloride disperse within minutes throughout the room.”
InfluentialSelf-citationViable influenza A virus in airborne particles expelled during coughs versus exhalations
Lindsley, W. G., Blachere, F. M., Beezhold, D. H., Thewlis, R. E., Noorbakhsh, B., Othumpangat, S., Goldsmith, W. T., McMillen, C. M., Andrew, M. E., Burrell, C. N., et al. (2016) · Influenza and Other Respiratory Viruses · doi:10.1111/irv.12390 · Cited by 147
Self-citationVerbeek, J. H., Ijaz, S., Mischke, C., Ruotsalainen, J. H., Mäkelä, E., Neuvonen, K., Edmond, M. B., Sauni, R., Kilinc Balci, F. S., & Mihalache, R. C. (2016) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd011621.pub2 · Cited by 113
Iannone, P., Castellini, G., Coclite, D., Napoletano, A., Fauci, A. J., Iacorossi, L., D’Angelo, D., Renzi, C., La Torre, G., Mastroianni, C. M., et al. (2020) · PLOS ONE · doi:10.1371/journal.pone.0234025 · Cited by 52
“Also, spontaneous cough generates aerosols, not only droplets [17, 18] and COVID-19 patients may infect HCWs in this way, especially if they are unable to wear facemasks due to hypoxia and need of oxygen therapy.”
BackgroundEdwards, N. J., Widrick, R., Wilmes, J., Breisch, B., Gerschefske, M., Sullivan, J., Potember, R., & Espinoza-Calvio, A. (2021) · Aerosol Science and Technology · doi:10.1080/02786826.2021.1966376 · Cited by 45
“During this study, the simulator dispersed the NaCl aerosols with exhalation air flows of PEF (SD) of 449.8 (50.8) L/min and FEV1 (SD) of 5.80 (0.33) L which are within range of a modest cough (Lindsley et al. 2012; 2013; Hui et al. 2012; Rothenberg et al. 1987).”
BackgroundInfluentialAerosols should not be defined by distance travelled
Tang, J. W., Marr, L. C., & Milton, D. K. (2021) · Journal of Hospital Infection · doi:10.1016/j.jhin.2021.05.007 · Cited by 12
Metadata
- Authors
- Lindsley, W. G., King, W. P., Thewlis, R. E., Reynolds, J. S., Panday, K., Cao, G., & Szalajda, J. V.
- Venue
- Journal of Occupational and Environmental Hygiene
- Publisher
- Informa UK Limited
- Published
- 2012-12
- Volume
- 9
- Issue
- 12
- Pages
- 681-690
- ISSN
- 1545-9624 (ISSN-L)
- 1545-9632
- OpenAlex
- W2043955676
- Cited by
- 91
- References
- 7
- FWCI
- 3.56
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.