The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Calibration of ActiGraph GT3X, Actical and RT3 accelerometers in adolescents
Abstract
The objective of this study was to develop count cut‐points for three different accelerometer models: ActiGraph GT3X, RT3 and Actical to accurately classify physical activity intensity levels in adolescents. Seventy‐nine adolescents (10–15 years) participated in this study. Accelerometers and oxygen consumption () data were collected at rest and during 11 physical activities of different intensities. Accelerometers were worn on the waist and was measured by a portable metabolic system: Cosmed K4b2. Receiver operating characteristic (ROC) curves were used to determine cut‐points. Cut‐points for sedentary (SED), moderate‐to‐vigorous (MVPA) and vigorous‐intensity physical activity (VPA) were 46, 607 and 818 counts·15s−1 to the vertical axis of ActiGraph; 180, 757 and 1112 counts·15s−1 to the vector magnitude of ActiGraph; 17, 441 and 873 counts·15s−1 for Actical; and 5.6, 20.4 and 32.2 counts·s−1 for RT3, respectively. For all three accelerometer models, there was an almost perfect discrimination of SED and MVPA (ROC >0.97) and an excellent discrimination of VPA (ROC>0.90) observed. Areas under the ROC curves indicated better discrimination of MVPA by ActiGraph (AUC=0.994) and Actical (AUC=0.993) when compared to RT3 (AUC=0.983). The cut‐points developed in this study for the ActiGraph (vector magnitude), RT3 and Actical accelerometer models can be used to monitor physical activity level of adolescents.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hanley, J. A., & McNeil, B. J. (1983) · Radiology · doi:10.1148/radiology.148.3.6878708 · Cited by 7,016
Janssen, I., & LeBlanc, A. G. (2010) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/1479-5868-7-40 · Cited by 4,829
Evidence Based Physical Activity for School-age Youth
Strong, W. B., Malina, R. M., Blimkie, C. J. R., Daniels, S. R., Dishman, R. K., Gutin, B., Hergenroeder, A. C., Must, A., Nixon, P. A., Pivarnik, J. M., et al. (2005) · The Journal of Pediatrics · doi:10.1016/j.jpeds.2005.01.055 · Cited by 4,222
Calibration of two objective measures of physical activity for children
Evenson, K. R., Catellier, D. J., Gill, K., Ondrak, K. S., & McMurray, R. G. (2008) · Journal of Sports Sciences · doi:10.1080/02640410802334196 · Cited by 2,677 · cited 4×
“The cut-points derived for SED and MVPA from the vertical axis of ActiGraph GT3X were quite similar to those validated by Evenson et al. (2008) for children and adolescents ( 100 and 2300 counts min 1 to SED and MVPA, respectively).”
MethodResultInfluentialComparison of Accelerometer Cut Points for Predicting Activity Intensity in Youth
TROST, S. G., LOPRINZI, P. D., MOORE, R., & PFEIFFER, K. A. (2011) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e318206476e · Cited by 1,360
The Technology of Accelerometry-Based Activity Monitors: Current and Future
CHEN, K. Y., & BASSETT, D. R. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185571.49104.82 · Cited by 996
Objective measurement of physical activity and sedentary behaviour: review with new data
Reilly, J. J., Penpraze, V, Hislop, J., Davies, G., Grant, S., & Paton, J. Y. (2008) · Archives of Disease in Childhood · doi:10.1136/adc.2007.133272 · Cited by 564
Energy Costs of Physical Activities in Children and Adolescents
HARRELL, J. S., MCMURRAY, R. G., BAGGETT, C. D., PENNELL, M. L., PEARCE, P. F., & BANGDIWALA, S. I. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000153115.33762.3f · Cited by 374
Validity and Reproducibility of Motion Sensors in Youth: A Systematic Update
DE VRIES, S. I., VAN HIRTUM, H. W. J. E. M., BAKKER, I., HOPMAN-ROCK, M., HIRASING, R. A., & VAN MECHELEN, W. (2009) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31818e5819 · Cited by 201 · cited 1×
“ActiGraph is the most widely used accelerometer in physical activity studies (De Vries et al., 2009) and Correspondence: Marcelo Romanzini, Department of Physical Education, State University of Londrina, Rod.”
Method
Research works printed but not linked: 21
- 10.1249/mss.0b013e318148436c · DOI
- 10.1136/bmj.320.7244.1240 · DOI · Paper page
- 10.1080/02640414.2011.557744 · DOI · Paper page
- 10.1249/mss.0b013e318150dff8 · DOI
- 10.1249/MSS.0b013e3181e27b5d · DOI
- 10.1249/01.mss.0000185658.28284.ba · DOI · Paper page
- Hänggi J. M. Phillips L. R. &Rowlands A. V.(in press). Validation of the GT3X ActiGraph in children and comparison with the GT1M ActiGraph.Journal of Science and Medicine in Sport.
- 10.1080/02701367.2006.10599333 · DOI · Paper page
- 10.1080/02640410600908027 · DOI
- 10.1080/02640410801910251 · DOI
- 10.1016/S1728-869X(11)60002-6 · DOI
- 10.1080/17477160701408809 · DOI · Paper page
- 10.1038/oby.2006.234 · DOI · Paper page
- 10.1249/01.mss.0000183219.44127.e7 · DOI · Paper page
- 10.1038/oby.2002.24 · DOI · Paper page
- Puyau M. R., 2004, Prediction of activity energy expenditure using accelerometers in children, Medicine and Science in Sports and Exercise, 36, 1625
- 10.1123/pes.19.3.252 · DOI · Paper page
- 10.1249/01.MSS.0000117158.14542.E7 · DOI · Paper page
- Treuth M. S., 2004, Defining accelerometer thresholds for activity intensities in adolescent girls, Medicine and Science in Sports and Exercise, 36, 1259
- 10.1080/02640410903508821 · DOI
- 10.1097/MRR.0b013e328340129e · DOI
Cited by
Migueles, J. H., Cadenas-Sanchez, C., Ekelund, U., Delisle Nyström, C., Mora-Gonzalez, J., Löf, M., Labayen, I., Ruiz, J. R., & Ortega, F. B. (2017) · Sports Medicine · doi:10.1007/s40279-017-0716-0 · Cited by 1,868
Barnett, T. A., Kelly, A. S., Young, D. R., Perry, C. K., Pratt, C. A., Edwards, N. M., Rao, G., Vos, M. B., & On behalf of the American Heart Association Obesity Committee of the Council on Lifestyle and Cardiometabolic Health; Council on Cardiovascular Disease in the Young; and Stroke Council (2018) · Circulation · doi:10.1161/cir.0000000000000591 · Cited by 249
Dettweiler, U., Becker, C., Auestad, B. H., Simon, P., & Kirsch, P. (2017) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph14050475 · Cited by 84
Comeras-Chueca, C., Villalba-Heredia, L., Pérez-Llera, M., Lozano-Berges, G., Marín-Puyalto, J., Vicente-Rodríguez, G., Matute-Llorente, Á., Casajús, J. A., & González-Agüero, A. (2020) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph17186714 · Cited by 35
“These devices were placed on their left hip, which has been shown to be the region providing the most reliable data using this technique [37].”
MethodKallesøe, K. H., Schröder, A., Wicksell, R. K., Fink, P., Ørnbøl, E., & Rask, C. U. (2016) · BMJ Open · doi:10.1136/bmjopen-2016-012743 · Cited by 23
“Physical activity Level of physical activity is assessed pretreatment and post-treatment by anthropometric measurements with an accelerometer (Actigraph wGT3X-BT).(72) The accelerometer is worn on the right hip 24 hours-a-day for seven consecutive days.”
Method
Metadata
- Authors
- Romanzini, M., Petroski, E. L., Ohara, D., Dourado, A. C., & Reichert, F. F.
- Venue
- European Journal of Sport Science
- Publisher
- Wiley
- Published
- 2012-10-18
- Volume
- 14
- Issue
- 1
- Pages
- 91-99
- ISSN
- 1536-7290 (ISSN-L)
- 1746-1391
- OpenAlex
- W2024167552
- Cited by
- 203
- References
- 9
- FWCI
- 0.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.