The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Basic mathematical and electromagnetic concepts of the biomagnetic inverse problem
Open accessAbstract
In this paper basic mathematical and physical concepts of the biomagnetic inverse problem are reviewed with some new approaches. The forward problem is discussed for both homogeneous and inhomogeneous media. Geselowitz' formulae and a surface integral equation are presented to handle a piecewise homogeneous conductor. The special cases of a spherically symmetric conductor and a horizontally layered medium are discussed in detail. The non-uniqueness of the solution of the magnetic inverse problem is discussed and the difficulty caused by the contribution of the electric potential to the magnetic field outside the conductor is studied. As practical methods of solving the inverse problem, a weighted least-squares search with confidence limits and the method of minimum norm estimate are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Model Studies of the Magnetocardiogram
Grynszpan, F., & Geselowitz, D. B. (1973) · Biophysical Journal · doi:10.1016/s0006-3495(73)86034-5 · Cited by 226 · cited 1×
“Analternativederivation of formulae for U and B outside G was performed by Grynszpan and Geselowitz (1973) and Ilmoniemi et al (1985).”
Method
Cited by
Hämäläinen, M., Hari, R., Ilmoniemi, R. J., Knuutila, J., & Lounasmaa, O. V. (1993) · Reviews of Modern Physics · doi:10.1103/revmodphys.65.413 · Cited by 4,684
Interpreting magnetic fields of the brain: minimum norm estimates
Hämäläinen, M. S., & Ilmoniemi, R. J. (1994) · Medical & Biological Engineering & Computing · doi:10.1007/bf02512476 · Cited by 1,995
Digital twin: values, challenges and enablers from a modeling perspective
Rasheed, A., San, O., & Kvamsdal, T. (2020) · IEEE Access · doi:10.1109/access.2020.2970143 · Cited by 1,952
Identifying true brain interaction from EEG data using the imaginary part of coherency
Nolte, G., Bai, O., Wheaton, L., Mari, Z., Vorbach, S., & Hallett, M. (2004) · Clinical Neurophysiology · doi:10.1016/j.clinph.2004.04.029 · Cited by 1,756
Moving magnetoencephalography towards real-world applications with a wearable system
Boto, E., Holmes, N., Leggett, J., Roberts, G., Shah, V., Meyer, S. S., Muñoz, L. D., Mullinger, K. J., Tierney, T. M., Bestmann, S., et al. (2018) · Nature · doi:10.1038/nature26147 · Cited by 1,377
Multiple dipole modeling and localization from spatio-temporal MEG data
Mosher, J. C., Lewis, P. S., & Leahy, R. M. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.141192 · Cited by 1,048
Investigating the electrophysiological basis of resting state networks using magnetoencephalography
Brookes, M. J., Woolrich, M., Luckhoo, H., Price, D., Hale, J. R., Stephenson, M. C., Barnes, G. R., Smith, S. M., & Morris, P. G. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1112685108 · Cited by 938
Realistic conductivity geometry model of the human head for interpretation of neuromagnetic data
Hamalainen, M. S., & Sarvas, J. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.16463 · Cited by 989
Self-citationSignal Processing in Magnetoencephalography
Vrba, J., & Robinson, S. E. (2001) · Methods · doi:10.1006/meth.2001.1238 · Cited by 716
Optical magnetic detection of single-neuron action potentials using quantum defects in diamond
Barry, J. F., Turner, M. J., Schloss, J. M., Glenn, D. R., Song, Y., Lukin, M. D., Park, H., & Walsworth, R. L. (2016) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1601513113 · Cited by 637
Neuromagnetic source imaging with FOCUSS: a recursive weighted minimum norm algorithm
Gorodnitsky, I. F., George, J. S., & Rao, B. D. (1995) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(95)00107-a · Cited by 567
Measuring functional connectivity using MEG: methodology and comparison with fcMRI
Brookes, M. J., Hale, J. R., Zumer, J. M., Stevenson, C. M., Francis, S. T., Barnes, G. R., Owen, J. P., Morris, P. G., & Nagarajan, S. S. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.02.054 · Cited by 519
Dyslexia-specific brain activation profile becomes normal following successful remedial training
Simos, P. G., Fletcher, J. M., Bergman, E., Breier, J. I., Foorman, B. R., Castillo, E. M., Davis, R. N., Fitzgerald, M., & Papanicolaou, A. C. (2002) · Neurology · doi:10.1212/wnl.58.8.1203 · Cited by 450
van Diessen, E., Numan, T., van Dellen, E., van der Kooi, A. W., Boersma, M., Hofman, D., van Lutterveld, R., van Dijk, B. W., van Straaten, E. C. W., Hillebrand, A., et al. (2015) · Clinical Neurophysiology · doi:10.1016/j.clinph.2014.11.018 · Cited by 417
Murakami, S., & Okada, Y. (2006) · The Journal of Physiology · doi:10.1113/jphysiol.2006.105379 · Cited by 395
Mathematical framework for large-scale brain network modeling in The Virtual Brain
Sanz-Leon, P., Knock, S. A., Spiegler, A., & Jirsa, V. K. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2015.01.002 · Cited by 356
Residual cerebral activity and behavioural fragments can remain in the persistently vegetative brain
Schiff, N. D., Ribary, U., Moreno, D. R., Beattie, B., Kronberg, E., Blasberg, R., Giacino, J., McCagg, C., Fins, J. J., Llinás, R., et al. (2002) · Brain · doi:10.1093/brain/awf131 · Cited by 306
Wang, J.-Z., Williamson, S. J., & Kaufman, L. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.142641 · Cited by 299
Multi-Channel Whole-Head OPM-MEG: Helmet Design and a Comparison with a Conventional System
Hill, R. M., Boto, E., Rea, M., Holmes, N., Leggett, J., Coles, L. A., Papastavrou, M., Everton, S. K., Hunt, B. A. E., Sims, D., et al. (2020) · NeuroImage · doi:10.1016/j.neuroimage.2020.116995 · Cited by 285
Selective minimum-norm solution of the biomagnetic inverse problem
Matsuura, K., & Okabe, Y. (1995) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.387200 · Cited by 243
Holmes, N., Leggett, J., Boto, E., Roberts, G., Hill, R. M., Tierney, T. M., Shah, V., Barnes, G. R., Brookes, M. J., & Bowtell, R. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2018.07.028 · Cited by 250
TMS combined with EEG: Recommendations and open issues for data collection and analysis
Hernandez-Pavon, J. C., Veniero, D., Bergmann, T. O., Belardinelli, P., Bortoletto, M., Casarotto, S., Casula, E. P., Farzan, F., Fecchio, M., Julkunen, P., et al. (2023) · Brain Stimulation · doi:10.1016/j.brs.2023.02.009 · Cited by 238
On the Potential of a New Generation of Magnetometers for MEG: A Beamformer Simulation Study
Boto, E., Bowtell, R., Krüger, P., Fromhold, T. M., Morris, P. G., Meyer, S. S., Barnes, G. R., & Brookes, M. J. (2016) · PLOS ONE · doi:10.1371/journal.pone.0157655 · Cited by 194
A tool for functional brain imaging with lifespan compliance
Hill, R. M., Boto, E., Holmes, N., Hartley, C., Seedat, Z. A., Leggett, J., Roberts, G., Shah, V., Tierney, T. M., Woolrich, M. W., et al. (2019) · Nature Communications · doi:10.1038/s41467-019-12486-x · Cited by 180
Jones, S. R., Pritchett, D. L., Stufflebeam, S. M., Hämäläinen, M., & Moore, C. I. (2007) · The Journal of Neuroscience · doi:10.1523/jneurosci.0482-07.2007 · Cited by 160
Towards OPM-MEG in a Virtual Reality Environment
Roberts, G., Holmes, N., Alexander, N., Boto, E., Leggett, J., Hill, R. M., Shah, V., Rea, M., Vaughan, R., Maguire, E. A., et al. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.06.010 · Cited by 128
Wearable neuroimaging: Combining and contrasting magnetoencephalography and electroencephalography
Boto, E., Seedat, Z. A., Holmes, N., Leggett, J., Hill, R. M., Roberts, G., Shah, V., Fromhold, T. M., Mullinger, K. J., Tierney, T. M., et al. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.116099 · Cited by 136
SQUID sensor array configurations for magnetoencephalography applications
Vrba, J., & Robinson, S. E. (2002) · Superconductor Science and Technology · doi:10.1088/0953-2048/15/9/201 · Cited by 126
Neymotin, S. A., Daniels, D. S., Caldwell, B., McDougal, R. A., Carnevale, N. T., Jas, M., Moore, C. I., Hines, M. L., Hämäläinen, M., & Jones, S. R. (2020) · eLife · doi:10.7554/elife.51214 · Cited by 109
Premotor cortex mediates perceptual performance
Callan, D., Callan, A., Gamez, M., Sato, M.-A., & Kawato, M. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.02.027 · Cited by 104
On MEG forward modelling using multipolar expansions
Jerbi, K., Mosher, J. C., Baillet, S., & Leahy, R. M. (2002) · Physics in Medicine and Biology · doi:10.1088/0031-9155/47/4/301 · Cited by 103
Holmes, N., Rea, M., Hill, R. M., Leggett, J., Edwards, L. J., Hobson, P. J., Boto, E., Tierney, T. M., Rier, L., Rivero, G. R., et al. (2023) · NeuroImage · doi:10.1016/j.neuroimage.2023.120157 · Cited by 89
Digital Twin: Values, Challenges and Enablers
Rasheed, A., San, O., & Kvamsdal, T. (2019) · arXiv · doi:10.48550/arxiv.1910.01719 · Cited by 81
Auditory evoked magnetic fields in adults with fragile X syndrome.
Rojas, D. C., Benkers, T. L., Rogers, S. J., Teale, P. D., Reite, M. L., & Hagerman, R. J. (2001) · Neuroreport · doi:10.1097/00001756-200108080-00056 · Cited by 73
Petrini, G., Moreva, E., Bernardi, E., Traina, P., Tomagra, G., Carabelli, V., Degiovanni, I. P., & Genovese, M. (2020) · Advanced Quantum Technologies · doi:10.1002/qute.202000066 · Cited by 63
Paired MEG data set source localization using recursively applied and projected (RAP) MUSIC
Ermer, J. J., Mosher, J. C., Huang, M., & Leahy, R. M. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.867959 · Cited by 64
MATTOUT, J., PELEGRINIISSAC, M., GARNERO, L., & BENALI, H. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.01.026 · Cited by 52
Naturalistic Hyperscanning with Wearable Magnetoencephalography
Holmes, N., Rea, M., Hill, R. M., Boto, E., Leggett, J., Edwards, L. J., Rhodes, N., Shah, V., Osborne, J., Fromhold, T. M., et al. (2023) · Sensors · doi:10.3390/s23125454 · Cited by 52
“The f rward f el vector was culated using multi-sph re head model and the current dipole approximation [55].”
MethodProbabilistic reconstruction of multiple sources in the bioelectromagnetic inverse problem
Greenblatt, R. E. (1993) · Inverse Problems · doi:10.1088/0266-5611/9/2/008 · Cited by 48
Nugent, A. C., Benitez Andonegui, A., Holroyd, T., & Robinson, S. E. (2022) · Neuroimage: Reports · doi:10.1016/j.ynirp.2022.100093 · Cited by 41
Investigations of sensitivity and resolution of ECG and MCG in a realistically shaped thorax model
Mäntynen, V., Konttila, T., & Stenroos, M. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/23/7141 · Cited by 45
(2011) · Cited by 42
A study of scalar optically-pumped magnetometers for use in magnetoencephalography without shielding
Clancy, R. J., Gerginov, V., Alem, O., Becker, S., & Knappe, S. (2021) · Physics in Medicine & Biology · doi:10.1088/1361-6560/ac18fb · Cited by 37
Hajizadeh, A., Matysiak, A., May, P. J. C., & König, R. (2019) · Biological Cybernetics · doi:10.1007/s00422-019-00795-9 · Cited by 14
Hajizadeh, A., Matysiak, A., Brechmann, A., König, R., & May, P. J. C. (2021) · Psychophysiology · doi:10.1111/psyp.13769 · Cited by 9
Metadata
- Authors
- Sarvas, J.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 1987-01-01
- Volume
- 32
- Issue
- 1
- Pages
- 11-22
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W1987333243
- Cited by
- 1,843
- References
- 1
- FWCI
- 14.72
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.