Adaptive-weighted total variation minimization for sparse data toward low-dose x-ray computed tomography image reconstruction
Open accessThe DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.
Abstract
Previous studies have shown that by minimizing the total variation (TV) of the to-be-estimated image with some data and other constraints, piecewise-smooth x-ray computed tomography (CT) can be reconstructed from sparse-view projection data without introducing notable artifacts. However, due to the piecewise constant assumption for the image, a conventional TV minimization algorithm often suffers from over-smoothness on the edges of the resulting image. To mitigate this drawback, we present an adaptive-weighted TV (AwTV) minimization algorithm in this paper. The presented AwTV model is derived by considering the anisotropic edge property among neighboring image voxels, where the associated weights are expressed as an exponential function and can be adaptively adjusted by the local image-intensity gradient for the purpose of preserving the edge details. Inspired by the previously reported TV-POCS (projection onto convex sets) implementation, a similar AwTV-POCS implementation was developed to minimize the AwTV subject to data and other constraints for the purpose of sparse-view low-dose CT image reconstruction. To evaluate the presented AwTV-POCS algorithm, both qualitative and quantitative studies were performed by computer simulations and phantom experiments. The results show that the presented AwTV-POCS algorithm can yield images with several notable gains, in terms of noise-resolution tradeoff plots and full-width at half-maximum values, as compared to the corresponding conventional TV-POCS algorithm.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Donoho, D. L. (2006) · IEEE Transactions on Information Theory · doi:10.1109/tit.2006.871582 · Cited by 23,994
Donoho, D. L. (2004) · Cited by 16,591
Nonlinear total variation based noise removal algorithms
Rudin, L. I., Osher, S., & Fatemi, E. (1992) · Physica D: Nonlinear Phenomena · doi:10.1016/0167-2789(92)90242-f · Cited by 15,704
Candes, E. J., Romberg, J., & Tao, T. (2006) · IEEE Transactions on Information Theory · doi:10.1109/tit.2005.862083 · Cited by 15,639
Scale-space and edge detection using anisotropic diffusion
Perona, P., & Malik, J. (1990) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.56205 · Cited by 12,119
An Introduction To Compressive Sampling
Candes, E. J., & Wakin, M. B. (2008) · IEEE Signal Processing Magazine · doi:10.1109/msp.2007.914731 · Cited by 10,017 · cited 3×
“However, for CT image reconstruction, particularly in low-dose CT applications, the associated transfer matrix of sparse signals in the transfer domain is less likely to have the RIP (Sidky et al 2006, Sidky and Pan 2008).”
BackgroundComputed Tomography — An Increasing Source of Radiation Exposure
Brenner, D. J., & Hall, E. J. (2007) · New England Journal of Medicine · doi:10.1056/nejmra072149 · Cited by 8,748
Sidky, E. Y., & Pan, X. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/17/021 · Cited by 1,995
Andersen, A. (1984) · Ultrasonic Imaging · doi:10.1016/0161-7346(84)90008-7 · Cited by 1,812
Einstein, A. J., Henzlova, M. J., & Rajagopalan, S. (2007) · JAMA · doi:10.1001/jama.298.3.317 · Cited by 1,410
Accurate image reconstruction from few-views and limited-angle data in divergent-beam CT
Sidky, E. Y., Kao, C.-M., & Pan, X. (2006) · Journal of X-Ray Science and Technology: Clinical Applications of Diagnosis and Therapeutics · doi:10.3233/xst-2006-00155 · Cited by 1,091
X-ray phase-contrast imaging: from pre-clinical applications towards clinics
Bravin, A., Coan, P., & Suortti, P. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/1/r1 · Cited by 846
Strategies for Reducing Radiation Dose in CT
McCollough, C. H., Primak, A. N., Braun, N., Kofler, J., Yu, L., & Christner, J. (2009) · Radiologic Clinics of North America · doi:10.1016/j.rcl.2008.10.006 · Cited by 842 · cited 1×
“Up to now, many hardware-based optimal dataacquisition protocols have been proposed for dose reduction (Kalra et al 2003, Smith et al 2007, McCollough et al 2009).”
BackgroundStatistical image reconstruction for polyenergetic X-ray computed tomography
Elbakri, I. A., & Fessler, J. A. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/42.993128 · Cited by 691
Low-Dose X-ray CT Reconstruction via Dictionary Learning
Xu, Q., Yu, H., Mou, X., Zhang, L., Hsieh, J., & Wang, G. (2012) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2012.2195669 · Cited by 690
Penalized weighted least-squares image reconstruction for dual energy X-ray transmission tomography
Sukovic, P., & Clinthorne, N. H. (2000) · IEEE Transactions on Medical Imaging · doi:10.1109/42.896783 · Cited by 552
Wang, J., Li, T., Lu, H., & Liang, Z. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.882141 · Cited by 533
Self-citationCompressed sensing based interior tomography
Yu, H., & Wang, G. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/9/014 · Cited by 519
Addition of a channel mechanism to the ideal-observer model
Myers, K. J., & Barrett, H. H. (1987) · Journal of the Optical Society of America A · doi:10.1364/josaa.4.002447 · Cited by 400
Low-dose CT reconstruction via edge-preserving total variation regularization
Tian, Z., Jia, X., Yuan, K., Pan, T., & Jiang, S. B. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/18/011 · Cited by 396
An Improved Algorithm for Reprojecting Rays through Pixel Images
Joseph, P. M. (1982) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1982.4307572 · Cited by 375
Evaluation of sparse-view reconstruction from flat-panel-detector cone-beam CT
Bian, J., Siewerdsen, J. H., Han, X., Sidky, E. Y., Prince, J. L., Pelizzari, C. A., & Pan, X. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/22/001 · Cited by 373
Nonlinear sinogram smoothing for low-dose X-ray CT
Li, T., Li, X., Wang, J., Wen, J., Lu, H., Hsieh, J., & Liang, Z. (2004) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2004.834824 · Cited by 309
Self-citationMa, J., Huang, J., Feng, Q., Zhang, H., Lu, H., Liang, Z., & Chen, W. (2011) · Medical Physics · doi:10.1118/1.3638125 · Cited by 249
Self-citationVariance analysis of x-ray CT sinograms in the presence of electronic noise background
Ma, J., Liang, Z., Fan, Y., Liu, Y., Huang, J., Chen, W., & Lu, H. (2012) · Medical Physics · doi:10.1118/1.4722751 · Cited by 177
Self-citationPark, J. C., Song, B., Kim, J. S., Park, S. H., Kim, H. K., Liu, Z., Suh, T. S., & Song, W. Y. (2012) · Medical Physics · doi:10.1118/1.3679865 · Cited by 149
Nonlocal Prior Bayesian Tomographic Reconstruction
Chen, Y., Ma, J., Feng, Q., Luo, L., Shi, P., & Chen, W. (2007) · Journal of Mathematical Imaging and Vision · doi:10.1007/s10851-007-0042-5 · Cited by 131
Self-citationImplementation of an optimal first-order method for strongly convex total variation regularization
Jensen, T. L., Jørgensen, J. S., Hansen, P. C., & Jensen, S. H. (2011) · BIT Numerical Mathematics · doi:10.1007/s10543-011-0359-8 · Cited by 127
Total variation superiorization schemes in proton computed tomography image reconstruction
Penfold, S. N., Schulte, R. W., Censor, Y., & Rosenfeld, A. B. (2010) · Medical Physics · doi:10.1118/1.3504603 · Cited by 110
Total variation superiorization schemes in proton computed tomography image reconstruction
Penfold, S., Schulte, R. W., Censor, Y., & Rosenfeld, A. B. (2010) · Research Online (University of Wollongong) · Cited by 104
An algorithm for total variation regularization in high-dimensional linear problems
Defrise, M., Vanhove, C., & Liu, X. (2011) · Inverse Problems · doi:10.1088/0266-5611/27/6/065002 · Cited by 101
Can Noise Reduction Filters Improve Low-Radiation-Dose Chest CT Images? Pilot Study
Kalra, M. K., Wittram, C., Maher, M. M., Sharma, A., Avinash, G. B., Karau, K. L., Toth, T. L., Halpern, E. F., Saini, S., & Shepard, J.-A. O. (2003) · Radiology · doi:10.1148/radiol.2281020606 · Cited by 101
Noise properties of low-dose CT projections and noise treatment by scale transformations
Lu, H., Hsiao, I., Li, X., & Liang, Z. (2005) · IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) · doi:10.1109/nssmic.2001.1008660 · Cited by 99
Self-citationRadiation Dose-Reduction Strategies for Neuroradiology CT Protocols
Smith, A. B., Dillon, W. P., Gould, R. G., & Wintermark, M. (2007) · American Journal of Neuroradiology · doi:10.3174/ajnr.a0814 · Cited by 99
Niu, T., & Zhu, L. (2012) · Medical Physics · doi:10.1118/1.4729837 · Cited by 86
Dose reduction for kilovotage cone-beam computed tomography in radiation therapy
Wang, J., Li, T., Liang, Z., & Xing, L. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/11/009 · Cited by 84
Self-citationStatistical reconstruction for x-ray computed tomography using energy-integrating detectors
Lasio, G., Whiting, B. R., & Williamson, J. F. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/8/014 · Cited by 76
Electronic Noise Modeling in Statistical Iterative Reconstruction
Xu, J., & Tsui, B. M. W. (2009) · IEEE Transactions on Image Processing · doi:10.1109/tip.2009.2017139 · Cited by 76
Prior image constrained compressed sensing (PICCS)
Chen, G., Tang, J., & Leng, S. (2008) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.770532 · Cited by 74
Cited by
Yang, Q., Yan, P., Zhang, Y., Yu, H., Shi, Y., Mou, X., Kalra, M. K., Zhang, Y., Sun, L., & Wang, G. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2827462 · Cited by 1,630
Willemink, M. J., & Noël, P. B. (2019) · European Radiology · doi:10.1007/s00330-018-5810-7 · Cited by 603
Li, M., Hsu, W., Xie, X., Cong, J., & Gao, W. (2020) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2020.2968472 · Cited by 321
Sparse-view x-ray CT reconstruction via total generalized variation regularization
Niu, S., Gao, Y., Bian, Z., Huang, J., Chen, W., Yu, G., Liang, Z., & Ma, J. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/12/2997 · Cited by 291
Self-citationTexture Feature Analysis for Computer-Aided Diagnosis on Pulmonary Nodules
Han, F., Wang, H., Zhang, G., Han, H., Song, B., Li, L., Moore, W., Lu, H., Zhao, H., & Liang, Z. (2015) · Journal of Digital Imaging · doi:10.1007/s10278-014-9718-8 · Cited by 265
Self-citation
Metadata
- Authors
- Liu, Y., Ma, J., Fan, Y., & Liang, Z.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2012-11-15
- Volume
- 57
- Issue
- 23
- Pages
- 7923-7956
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2007522854
- Cited by
- 335
- References
- 39
- FWCI
- 8.01
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.