Dose in x-ray computed tomography
Open accessThe DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Abstract
Radiation dose in x-ray computed tomography (CT) has become a topic of high interest due to the increasing numbers of CT examinations performed worldwide. This review aims to present an overview of current concepts for both scanner output metrics and for patient dosimetry and will comment on their strengths and weaknesses. Controversial issues such as the appropriateness of the CT dose index (CTDI) are discussed in detail. A review of approaches to patient dose assessment presently in practice, of the dose levels encountered and options for further dose optimization are also given and discussed. Patient dose assessment remains a topic for further improvement and for international consensus. All approaches presently in use are based on Monte Carlo (MC) simulations. Estimates for effective dose are established, but they are crude and not patient-specific; organ dose estimates are rarely available. Patient- and organ-specific dose estimates can be provided with adequate accuracy and independent of CTDI phantom measurements by fast MC simulations. Such information, in particular on 3D dose distributions, is important and helpful in optimization efforts. Dose optimization has been performed very successfully in recent years and even resulted in applications with effective dose values of below 1 mSv. In general, a trend towards lower dose values based on technical innovations has to be acknowledged. Effective dose values are down to clearly below 10 mSv on average, and there are a number of applications such as cardiac and pediatric CT which are performed routinely below 1 mSv on modern equipment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Computed Tomography — An Increasing Source of Radiation Exposure
Brenner, D. J., & Hall, E. J. (2007) · New England Journal of Medicine · doi:10.1056/nejmra072149 · Cited by 8,748
Recommendations of the International Commission on Radiological Protection
(1961) · Postgraduate Medical Journal · doi:10.1136/pgmj.37.425.168-b · Cited by 5,862
Sources and effects of ionizing radiation
(2018) · United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR) Reports · doi:10.18356/f48d655d-en · Cited by 3,985
Estimated Risks of Radiation-Induced Fatal Cancer from Pediatric CT
Brenner, D. J., Elliston, C. D., Hall, E. J., & Berdon, W. E. (2001) · American Journal of Roentgenology · doi:10.2214/ajr.176.2.1760289 · Cited by 3,222
2007 Recommendations of the International Commission on Radiological Protection
Publ., I. (2008) · Annals of the ICRP · Cited by 1,788
ICRP Publication 103, The Recommendations of the International Commission on Radiological Protection
Vetter, R. J. (2008) · Health Physics · doi:10.1097/01.hp.0000324200.73903.5b · Cited by 1,263
Chen, G.-H., Tang, J., & Leng, S. (2008) · Medical Physics · doi:10.1118/1.2836423 · Cited by 1,141
Kalender, W. A., Seissler, W., Klotz, E., & Vock, P. (1990) · Radiology · doi:10.1148/radiology.176.1.2353088 · Cited by 1,036 · cited 1×
“The trend continued into the 1990s which began with the introduction of spiral volumetric CT (Kalender et al 1990).”
BackgroundSelf-citationDeak, P. D., Smal, Y., & Kalender, W. A. (2010) · Radiology · doi:10.1148/radiol.10100047 · Cited by 858 · cited 2×
“DLP-to-E coefficients are widely available and have been extended to cover both sexes, children and newborns (Huda et al 2008, AAPM 2010, Deak et al 2010).”
BackgroundMethodSelf-citationX-ray phase-contrast imaging: from pre-clinical applications towards clinics
Bravin, A., Coan, P., & Suortti, P. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/1/r1 · Cited by 846
Iterative reconstruction methods in X-ray CT
Beister, M., Kolditz, D., & Kalender, W. A. (2012) · Physica Medica · doi:10.1016/j.ejmp.2012.01.003 · Cited by 751 · cited 1×
“A review paper on the generic principles and approaches was published in 2012 (Beister et al 2012) and may be helpful for interested readers.”
BackgroundSelf-citationComputed tomography : fundamentals, system technology, image quality, applications
Kalender, W. A. (2000) · Cited by 692
Self-citationSpecific absorbed fractions of energy at various ages from internal photon sources: 6, Newborn
Cristy, M., & Eckerman, K. F. (1987) · doi:10.2172/6202949 · Cited by 692
Kalender, W. A. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/13/r03 · Cited by 689 · cited 2×
“The trend of increasing patient dose values continued into the 2000s since increased x-ray power and further clinical applications such as cardiac CT became available (Kachelrieß and Kalender 1998, Kalender 2006).”
Self-citationAchenbach, S., Marwan, M., Ropers, D., Schepis, T., Pflederer, T., Anders, K., Kuettner, A., Daniel, W. G., Uder, M., & Lell, M. M. (2010) · European Heart Journal · doi:10.1093/eurheartj/ehp470 · Cited by 585 · cited 1×
“…today to quote effective dose values; interestingly, the quantity E used to specify dose is not even specified explicitly in many cases, e.g. ‘coronary CT with a consistent dose below 1 mSv using prospectively electrocardiogram-triggered high-pitch spiral acquisition’ (Achenbach et al 2010).”
MethodSize-Specific Dose Estimates (SSDE) in Pediatric and Adult Body CT Examinations
Boone, J., Strauss, K., Cody, D., McCollough, C., McNitt-Gray, M., Toth, T., Goske, M., & Frush, D. (2011) · doi:10.37206/143 · Cited by 551
Converting Dose-Length Product to Effective Dose at CT
Huda, W., Ogden, K. M., & Khorasani, M. R. (2008) · Radiology · doi:10.1148/radiol.2483071964 · Cited by 513 · cited 1×
“DLP-to-E coefficients are widely available and have been extended to cover both sexes, children and newborns (Huda et al 2008, AAPM 2010, Deak et al 2010).”
MethodThe Linear No-Threshold Relationship Is Inconsistent with Radiation Biologic and Experimental Data
Tubiana, M., Feinendegen, L. E., Yang, C., & Kaminski, J. M. (2009) · Radiology · doi:10.1148/radiol.2511080671 · Cited by 509 · cited 2×
“The risk of x-ray examinations in the low-dose range is not well known at all; no hard data are available for the dose range below 100 mSv (Feinendegen et al 1999, Tubiana et al 2009, Hendee and O’Connor 2012, Neumaier et al 2012).”
BackgroundCT Dose Index and Patient Dose: They Are Not the Same Thing
McCollough, C. H., Leng, S., Yu, L., Cody, D. D., Boone, J. M., & McNitt-Gray, M. F. (2011) · Radiology · doi:10.1148/radiol.11101800 · Cited by 463
A method for describing the doses delivered by transmission x-ray computed tomography
Shope, T. B., Gagne, R. M., & Johnson, G. C. (1981) · Medical Physics · doi:10.1118/1.594995 · Cited by 435 · cited 1×
“The concept of the CTDI was proposed and established in the USA by the Food and Drug Administration (FDA) in the late 1970s (Shope et al 1981).”
BackgroundBoone, J. M. (2007) · Medical Physics · doi:10.1118/1.2713240 · Cited by 417 · cited 2×
“In parallel to these technical developments, we also witnessed debates about scanner and patient dosimetry, primarily in the USA (Dixon et al 2005, Boone 2007, AAPM 2010).”
BackgroundPerformance evaluation of a multi-slice CT system
McCollough, C. H., & Zink, F. E. (1999) · Medical Physics · doi:10.1118/1.598777 · Cited by 386 · cited 1×
“It was a considerable problem when four-row detectors with exactly the same width as the nominal collimation were introduced (McCollough and Zink 1999), but becomes more and more negligible for the wider detectors used today since there is very little excess radiation relative to the primary…”
BackgroundRadiation Risks of Medical Imaging: Separating Fact from Fantasy
Hendee, W. R., & O’Connor, M. K. (2012) · Radiology · doi:10.1148/radiol.12112678 · Cited by 354
Dose reduction in CT by anatomically adapted tube current modulation. II. Phantom measurements
Kalender, W. A., Wolf, H., & Suess, C. (1999) · Medical Physics · doi:10.1118/1.598738 · Cited by 345
Self-citationKachelrieß, M., Watzke, O., & Kalender, W. A. (2001) · Medical Physics · doi:10.1118/1.1358303 · Cited by 311
Self-citationPhysicians’ Views Of The Relative Importance Of Thirty Medical Innovations
Fuchs, V. R., & Sox, H. C. (2001) · Health Affairs · doi:10.1377/hlthaff.20.5.30 · Cited by 288
McCollough, C. H., Chen, G. H., Kalender, W., Leng, S., Samei, E., Taguchi, K., Wang, G., Yu, L., & Pettigrew, R. I. (2012) · Radiology · doi:10.1148/radiol.12112265 · Cited by 276 · cited 1×
“Currently, low-dose CT and even ‘sub-mSv CT’ exams have become realistic options (Kalender 2011, McCollough et al 2012) and are in clinical use.”
BackgroundSelf-citationEvidence for formation of DNA repair centers and dose-response nonlinearity in human cells
Neumaier, T., Swenson, J., Pham, C., Polyzos, A., Lo, A. T., Yang, P., Dyball, J., Asaithamby, A., Chen, D. J., Bissell, M. J., et al. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1117849108 · Cited by 270 · cited 1×
“The risk of x-ray examinations in the low-dose range is not well known at all; no hard data are available for the dose range below 100 mSv (Feinendegen et al 1999, Tubiana et al 2009, Hendee and O’Connor 2012, Neumaier et al 2012). Nevertheless cancer deaths are often calculated based on the linear no-threshold (LNT)…”
Faigel, G., & Tegze, M. (1999) · Reports on Progress in Physics · doi:10.1088/0034-4885/62/3/002 · Cited by 266
Boone, J. M. (2012) · Medical Physics · doi:10.1118/1.4725757 · Cited by 247
Kalender, W. A., Wolf, H., Suess, C., Gies, M., Greess, H., & Bautz, W. A. (1999) · European Radiology · doi:10.1007/s003300050674 · Cited by 245
Self-citationCancer: science and society and the communication of risk
Calman, K. C. (1996) · BMJ · doi:10.1136/bmj.313.7060.799 · Cited by 243
A PC program for estimating organ dose and effective dose values in computed tomography
Kalender, W. A., Schmidt, B., Zankl, M., & Schmidt, M. (1999) · European Radiology · doi:10.1007/s003300050709 · Cited by 231
Self-citationECG‐correlated image reconstruction from subsecond multi‐slice spiral CT scans of the heart
Kachelrieß, M., Ulzheimer, S., & Kalender, W. A. (2000) · Medical Physics · doi:10.1118/1.1286552 · Cited by 225
Self-citationKachelriess, M., & Kalender, W. A. (1998) · Medical Physics · doi:10.1118/1.598453 · Cited by 212
Self-citationApplication‐ and patient size‐dependent optimization of x‐ray spectra for CT
Kalender, W. A., Deak, P., Kellermeier, M., van Straten, M., & Vollmar, S. V. (2009) · Medical Physics · doi:10.1118/1.3075901 · Cited by 206
Self-citation(2007) · Annals of the ICRP · doi:10.1016/j.icrp.2007.12.007 · Cited by 185
Enlarged longitudinal dose profiles in cone‐beam CT and the need for modified dosimetry
Mori, S., Endo, M., Nishizawa, K., Tsunoo, T., Aoyama, T., Fujiwara, H., & Murase, K. (2005) · Medical Physics · doi:10.1118/1.1877852 · Cited by 143 · cited 1×
“The situation was first addressed by Mori et al (2005) and by Boone (2007).”
BackgroundFast on‐site Monte Carlo tool for dose calculations in CT applications
Chen, W., Kolditz, D., Beister, M., Bohle, R., & Kalender, W. A. (2012) · Medical Physics · doi:10.1118/1.4711748 · Cited by 93
Self-citationFeinendegen, L. E., Bond, V. P., SONDHAUS, C. A., & Altman, K. I. (1999) · Comptes Rendus de l Académie des Sciences - Series III - Sciences de la Vie · doi:10.1016/s0764-4469(99)80051-1 · Cited by 48
Cited by
Cherry, S. R., Jones, T., Karp, J. S., Qi, J., Moses, W. W., & Badawi, R. D. (2018) · Journal of Nuclear Medicine · doi:10.2967/jnumed.116.184028 · Cited by 763
“However, there has been significant progress in lowdose CT protocols with advanced reconstruction methodology (20), and for diagnostic use and many research applications the effective dose using these techniques is likely acceptable.”
Background
Metadata
- Authors
- Kalender, W. A.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2014-01-17
- Volume
- 59
- Issue
- 3
- Pages
- R129-R150
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W1999051088
- Cited by
- 235
- References
- 40
- FWCI
- 19.00
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.