Blood pressure control with selective vagal nerve stimulation and minimal side effects
Open accessThe DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: Hypertension is the largest threat to patient health and a burden to health care systems. Despite various options, 30% of patients do not respond sufficiently to medical treatment. Mechanoreceptors in the aortic arch relay blood pressure (BP) levels through vagal nerve (VN) fibers to the brainstem and trigger the baroreflex, lowering the BP. Selective electrical stimulation of these nerve fibers reduced BP in rats. However, there is no technique described to localize and stimulate these fibers inside the VN without inadvertent stimulation of non-baroreceptive fibers causing side effects like bradycardia and bradypnea. APPROACH: We present a novel method for selective VN stimulation to reduce BP without the aforementioned side effects. Baroreceptor compound activity of rat VN (n = 5) was localized using a multichannel cuff electrode, true tripolar recording and a coherent averaging algorithm triggered by BP or electrocardiogram. MAIN RESULTS: Tripolar stimulation over electrodes near the barofibers reduced the BP without triggering significant bradycardia and bradypnea. The BP drop was adjusted to 60% of the initial value by varying the stimulation pulse width and duration, and lasted up to five times longer than the stimulation. SIGNIFICANCE: The presented method is robust to impedance changes, independent of the electrode's relative position, does not compromise the nerve and can run on implantable, ultra-low power signal processors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Functional and chemical anatomy of the afferent vagal system
Berthoud, H.-R., & Neuhuber, W. L. (2000) · Autonomic Neuroscience · doi:10.1016/s1566-0702(00)00215-0 · Cited by 1,280
Baroreflex Activation Therapy Lowers Blood Pressure in Patients With Resistant Hypertension
Bisognano, J. D., Bakris, G., Nadim, M. K., Sanchez, L., Kroon, A. A., Schafer, J., de Leeuw, P. W., & Sica, D. A. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.06.008 · Cited by 600
Vagus nerve stimulation: a new tool for brain research and therapy
George, M. S., Sackeim, H. A., Rush, A. J., Marangell, L. B., Nahas, Z., Husain, M. M., Lisanby, S., Burt, T., Goldman, J., & Ballenger, J. C. (2000) · Biological Psychiatry · doi:10.1016/s0006-3223(99)00308-x · Cited by 461
Functionally selective peripheral nerve stimulation with a flat interface nerve electrode
Tyler, D. J., & Durand, D. M. (2002) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2002.806840 · Cited by 398
Polyimide cuff electrodes for peripheral nerve stimulation
Rodri´guez, F. J., Ceballos, D., Schu¨ttler, M., Valero, A., Valderrama, E., Stieglitz, T., & Navarro, X. (2000) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(00)00192-8 · Cited by 207
Self-citationA nerve cuff technique for selective excitation of peripheral nerve trunk regions
Sweeney, J. D., Ksienski, D. A., & Mortimer, J. T. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.55681 · Cited by 196
Conditioned fear-induced tachycardia in the rat; vagal involvement
Nijsen, M. J. M. A., Croiset, G., Diamant, M., Stam, R., Delsing, D., de Wied, D., & Wiegant, V. M. (1998) · European Journal of Pharmacology · doi:10.1016/s0014-2999(98)00261-1 · Cited by 92
Design of a low-noise preamplifier for nerve cuff electrode recording
Rieger, R., Taylor, J., Demosthenous, A., Donaldson, N., & Langlois, P. J. (2003) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2003.814437 · Cited by 78 · cited 2×
“, ECG artifacts can be found in the tripole recordings [27].”
BackgroundClosed-loop control of the heart rate by electrical stimulation of the vagus nerve
Tosato, M., Yoshida, K., Toft, E., Nekrasas, V., & Struijk, J. J. (2006) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-006-0037-1 · Cited by 78 · cited 1×
“Selective electrical stimulation of these nerve fibers, when isolated from the VN, has been shown to activate the baroreflex and reduce the BP in rats [20, 21, 22, 23].”
BackgroundDevelopment of myelinated and unmyelinated fibers of human vagus nerve during the first year of life
Pereyra, P. M., Zhang, W., Schmidt, M., & Becker, L. E. (1992) · Journal of the Neurological Sciences · doi:10.1016/0022-510x(92)90016-e · Cited by 59
Cited by
Piech, D. K., Johnson, B. C., Shen, K., Ghanbari, M. M., Li, K. Y., Neely, R. M., Kay, J. E., Carmena, J. M., Maharbiz, M. M., & Muller, R. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-020-0518-9 · Cited by 442
Current Directions in the Auricular Vagus Nerve Stimulation I – A Physiological Perspective
Kaniusas, E., Kampusch, S., Tittgemeyer, M., Panetsos, F., Gines, R. F., Papa, M., Kiss, A., Podesser, B., Cassara, A. M., Tanghe, E., et al. (2019) · Frontiers in Neuroscience · doi:10.3389/fnins.2019.00854 · Cited by 323
Nanostructured platinum grass enables superior impedance reduction for neural microelectrodes
Boehler, C., Stieglitz, T., & Asplund, M. (2015) · Biomaterials · doi:10.1016/j.biomaterials.2015.07.036 · Cited by 179
“Current research addresses pain therapy by means of spinal cord stim ulation [2], deep brain stimulation to treat symptoms of Parkinson’s disease and severe psychiat ri disorders [3, 4], epilepsy diagnostics, artificial limb control [5], lost body function rep lacement [6] and modulation [7] or the development of brai…”
BackgroundSelf-citationA review for the peripheral nerve interface designer
Larson, C. E., & Meng, E. (2020) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2019.108523 · Cited by 133
Xiang, Z., Yen, S., Sheshadri, S., Wang, J., Lee, S., Liu, Y., Liao, L., Thakor, N. V., & Lee, C. (2016) · Advanced Materials · doi:10.1002/adma.201503423 · Cited by 116
Toward Bioelectronic Medicine—Neuromodulation of Small Peripheral Nerves Using Flexible Neural Clip
Lee, S., Peh, W. Y. X., Wang, J., Yang, F., Ho, J. S., Thakor, N. V., Yen, S., & Lee, C. (2017) · Advanced Science · doi:10.1002/advs.201700149 · Cited by 96
Selective Neuromodulation of the Vagus Nerve
Fitchett, A., Mastitskaya, S., & Aristovich, K. (2021) · Frontiers in Neuroscience · doi:10.3389/fnins.2021.685872 · Cited by 94
“However, evidence for spatial organization in the VN, combined with difficulties in avoiding the activation of larger fibers, has motivated the search for a spatially selective paradigm (Plachta et al., 2014).”
BackgroundResultInfluentialButz, N., Taschwer, A., Nessler, S., Manoli, Y., & Kuhl, M. (2018) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2018.2828823 · Cited by 70
“The inadvertent stimulation of non-baroreceptive fibers may cause severe side effects like bradycardia and bradypnea [5].”
BackgroundMethodInfluentialPrintable microscale interfaces for long-term peripheral nerve mapping and precision control
Otchy, T. M., Michas, C., Lee, B., Gopalan, K., Nerurkar, V., Gleick, J., Semu, D., Darkwa, L., Holinski, B. J., Chew, D. J., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-18032-4 · Cited by 35
Metadata
- Authors
- Plachta, D. T. T., Gierthmuehlen, M., Cota, O., Espinosa, N., Boeser, F., Herrera, T. C., Stieglitz, T., & Zentner, J.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2014-05-08
- Volume
- 11
- Issue
- 3
- Pages
- 036011
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2060718012
- Cited by
- 187
- References
- 11
- FWCI
- 5.48
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.