Blood pressure control with selective vagal nerve stimulation and minimal side effects
Open accessThe DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: Hypertension is the largest threat to patient health and a burden to health care systems. Despite various options, 30% of patients do not respond sufficiently to medical treatment. Mechanoreceptors in the aortic arch relay blood pressure (BP) levels through vagal nerve (VN) fibers to the brainstem and trigger the baroreflex, lowering the BP. Selective electrical stimulation of these nerve fibers reduced BP in rats. However, there is no technique described to localize and stimulate these fibers inside the VN without inadvertent stimulation of non-baroreceptive fibers causing side effects like bradycardia and bradypnea. APPROACH: We present a novel method for selective VN stimulation to reduce BP without the aforementioned side effects. Baroreceptor compound activity of rat VN (n = 5) was localized using a multichannel cuff electrode, true tripolar recording and a coherent averaging algorithm triggered by BP or electrocardiogram. MAIN RESULTS: Tripolar stimulation over electrodes near the barofibers reduced the BP without triggering significant bradycardia and bradypnea. The BP drop was adjusted to 60% of the initial value by varying the stimulation pulse width and duration, and lasted up to five times longer than the stimulation. SIGNIFICANCE: The presented method is robust to impedance changes, independent of the electrode's relative position, does not compromise the nerve and can run on implantable, ultra-low power signal processors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Calhoun, D. A., Jones, D., Textor, S., Goff, D. C., Murphy, T. P., Toto, R. D., White, A., Cushman, W. C., White, W., Sica, D., et al. (2008) · Circulation · doi:10.1161/circulationaha.108.189141 · Cited by 2,237
Functional and chemical anatomy of the afferent vagal system
Berthoud, H.-R., & Neuhuber, W. L. (2000) · Autonomic Neuroscience · doi:10.1016/s1566-0702(00)00215-0 · Cited by 1,280
Vagus nerve stimulation therapy for partial-onset seizures: A randomized active-control trial
Handforth, A., DeGiorgio, C. M., Schachter, S. C., Uthman, B. M., Naritoku, D. K., Tecoma, E. S., Henry, T. R., Collins, S. D., Vaughn, B. V., Gilmartin, R. C., et al. (1998) · Neurology · doi:10.1212/wnl.51.1.48 · Cited by 1,107
Experimental and surgical technique in the rat
Waynforth, H. B. (1980) · Medical Entomology and Zoology · Cited by 757
Baroreflex Activation Therapy Lowers Blood Pressure in Patients With Resistant Hypertension
Bisognano, J. D., Bakris, G., Nadim, M. K., Sanchez, L., Kroon, A. A., Schafer, J., de Leeuw, P. W., & Sica, D. A. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.06.008 · Cited by 600
Long-term control of arterial blood pressure
Cowley, A. W. (1992) · Physiological Reviews · doi:10.1152/physrev.1992.72.1.231 · Cited by 599
Vagus nerve stimulation: a new tool for brain research and therapy
George, M. S., Sackeim, H. A., Rush, A. J., Marangell, L. B., Nahas, Z., Husain, M. M., Lisanby, S., Burt, T., Goldman, J., & Ballenger, J. C. (2000) · Biological Psychiatry · doi:10.1016/s0006-3223(99)00308-x · Cited by 461
Functionally selective peripheral nerve stimulation with a flat interface nerve electrode
Tyler, D. J., & Durand, D. M. (2002) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2002.806840 · Cited by 398
Novel Baroreflex Activation Therapy in Resistant Hypertension
Scheffers, I. J. M., Kroon, A. A., Schmidli, J., Jordan, J., Tordoir, J. J. M., Mohaupt, M. G., Luft, F. C., Haller, H., Menne, J., Engeli, S., et al. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.03.089 · Cited by 355
The neuromyopathy of vincristine in man
Bradley, W. G., Lassman, L. P., Pearce, G. W., & Walton, J. N. (1970) · Journal of the Neurological Sciences · doi:10.1016/0022-510x(70)90013-4 · Cited by 261
Badia, J., Boretius, T., Andreu, D., Azevedo-Coste, C., Stieglitz, T., & Navarro, X. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/3/036023 · Cited by 227
Self-citationPolyimide cuff electrodes for peripheral nerve stimulation
Rodri´guez, F. J., Ceballos, D., Schu¨ttler, M., Valero, A., Valderrama, E., Stieglitz, T., & Navarro, X. (2000) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(00)00192-8 · Cited by 207
Self-citationA nerve cuff technique for selective excitation of peripheral nerve trunk regions
Sweeney, J. D., Ksienski, D. A., & Mortimer, J. T. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.55681 · Cited by 196
Relief of Angina Pectoris by Electrical Stimulation of the Carotid-Sinus Nerves
Braunwald, E., Epstein, S. E., Glick, G., Wechsler, A. S., & Braunwald, N. S. (1967) · New England Journal of Medicine · doi:10.1056/nejm196712142772402 · Cited by 185
Direct current electrical conduction block of peripheral nerve
Bhadra, N., & Kilgore, K. L. (2004) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2004.834205 · Cited by 178
High-resolution measurement of electrically-evoked vagus nerve activity in the anesthetized dog
Yoo, P. B., Lubock, N. B., Hincapie, J. G., Ruble, S. B., Hamann, J. J., & Grill, W. M. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/2/026003 · Cited by 143
Implantable biomedical microsystems for neural prostheses
Stieglitz, T., Schuetter, M., & Koch, K. P. (2005) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2005.1511501 · Cited by 140
Self-citationIllig, K. A., Levy, M., Sánchez, L. A., Trachiotis, G. D., Shanley, C. J., Irwin, E. D., Pertile, T., Kieval, R. S., & Cody, R. (2006) · Journal of Vascular Surgery · doi:10.1016/j.jvs.2006.08.024 · Cited by 130
WARNER, H. R. (1958) · Circulation Research · doi:10.1161/01.res.6.1.35 · Cited by 109
Fan, W., & Andresen, M. C. (1998) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1998.275.2.h632 · Cited by 100 · cited 1×
“Selective electrical stimulation of these nerve fibers, when isolated from the VN, has been shown to activate the baroreflex and reduce the BP in rats [20, 21, 22, 23].”
BackgroundIntraoperative and perioperative complications with a vagus nerve stimulation device
Fahy, B. G. (2010) · Journal of Clinical Anesthesia · doi:10.1016/j.jclinane.2009.10.002 · Cited by 95
A technique for anodally blocking large nerve fibres through chronically implanted electrodes.
Brindley, G. S., & Craggs, M. D. (1980) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.43.12.1083 · Cited by 94
Conditioned fear-induced tachycardia in the rat; vagal involvement
Nijsen, M. J. M. A., Croiset, G., Diamant, M., Stam, R., Delsing, D., de Wied, D., & Wiegant, V. M. (1998) · European Journal of Pharmacology · doi:10.1016/s0014-2999(98)00261-1 · Cited by 92
Design of a low-noise preamplifier for nerve cuff electrode recording
Rieger, R., Taylor, J., Demosthenous, A., Donaldson, N., & Langlois, P. J. (2003) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2003.814437 · Cited by 78 · cited 2×
“, ECG artifacts can be found in the tripole recordings [27].”
BackgroundClosed-loop control of the heart rate by electrical stimulation of the vagus nerve
Tosato, M., Yoshida, K., Toft, E., Nekrasas, V., & Struijk, J. J. (2006) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-006-0037-1 · Cited by 78 · cited 1×
“Selective electrical stimulation of these nerve fibers, when isolated from the VN, has been shown to activate the baroreflex and reduce the BP in rats [20, 21, 22, 23].”
BackgroundVučković, A., Tosato, M., & Struijk, J. J. (2008) · Journal of Neural Engineering · doi:10.1088/1741-2560/5/3/002 · Cited by 73 · cited 3×
“Our MCE and setup is not yet equipped with the capability to either fine tune the applied current via steering currents, nor is it capable of blocking the spreading of activity in unwanted (efferent) directions, especially of large, myelinated fibers like the recurrent laryngeal nerve (LRN) using HF or anodal blocks […”
BackgroundMethodInfluentialDevelopment of myelinated and unmyelinated fibers of human vagus nerve during the first year of life
Pereyra, P. M., Zhang, W., Schmidt, M., & Becker, L. E. (1992) · Journal of the Neurological Sciences · doi:10.1016/0022-510x(92)90016-e · Cited by 59
Delayed maturation of the vagus nerve in sudden infant death syndrome
Becker, L. E., Zhang, W., & Pereyra, P. M. (1993) · Acta Neuropathologica · doi:10.1007/bf00294301 · Cited by 42
D, E. B. M., Sobel, B. E., & Braunwald, N. S. (1969) · New England Journal of Medicine · doi:10.1056/nejm196910162811607 · Cited by 40
Thil, M., Duy, D. T., Colin, I. M., & Delbeke, J. (2007) · Journal of Neuroimmunology · doi:10.1016/j.jneuroim.2007.01.021 · Cited by 37
Artefact reduction with alternative cuff configurations
Struijk, L. N. S. A., & Struijk, J. J. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.817633 · Cited by 34
An implant for chronic selective stimulation of nerves
Bugbee, M., Donaldson, N., Lickel, A., Rijkhoff, N., & Taylor, J. T. (2001) · Medical Engineering & Physics · doi:10.1016/s1350-4533(01)00013-3 · Cited by 26
Ai, J., Wurster, R. D., Harden, S. W., & Cheng, Z. J. (2009) · Neuroscience · doi:10.1016/j.neuroscience.2009.06.066 · Cited by 25 · cited 1×
“to the brainstem and controls the baroreflex, a fast closedloop control to adapt the blood pressure to physiological demands [1, 2].”
BackgroundTHE THEORY OF PERIPHERAL NERVE RECORDING
Yoshida, K., & Struijk, J. J. (2004) · Series on bioengineering and biomedical engineering · doi:10.1142/9789812561763_0012 · Cited by 25
Li, Y., Peng, C., Chen, L.-T., Lin, W.-S., Chu, C.-H., & Chen, J. J. (2012) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2012.2219883 · Cited by 25 · cited 1×
“Chronically implanted metal electrodes always face impedance shifts caused by inflammatory response, protein adsorption and tissue growth or non-reversible electrochemical reactions on the electrodes [35, 36, 37].”
BackgroundOrdelman, S. C. M. A., Kornet, L., Cornelussen, R. N., Buschman, H. P. J., & Veltink, P. H. (2012) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2012.2214058 · Cited by 23
Zheng, X., Zhang, J., Chen, T., & Chen, Z. (2003) · Microsurgery · doi:10.1002/micr.10116 · Cited by 22
Timing and Efficacy of Alternative Methods of Sympathetic Blockade
Briasoulis, Α., & Bakris, G. L. (2012) · Current Hypertension Reports · doi:10.1007/s11906-012-0294-3 · Cited by 12 · cited 1×
“Clinical trials were initiated (Rheos Feasibility Trial and Rheos Pivotal Trial) and showed that baroreflex stimulation therapy may be a treatment option for a selected patient population with therapy resistant hypertension, a condition affecting up to 30% of all patients [11, 12].”
MethodRozman, J., & Ribarič, S. (2007) · PubMed · Cited by 10
Asymmetrical distribution of aortic nerve fibers in the pig
Prakash, P., & Safanie, A. H. (1967) · The Anatomical Record · doi:10.1002/ar.1091580107 · Cited by 9 · cited 7×
“In the rat, the ADN follows alongside the VN within the vagal nerve bundle (figure 1).”
BackgroundInfluentialDepressor effect of closed-loop chip system in spontaneously hypertensive rats
Gao, X.-Y., Huang, X.-L., Wang, H., Zhou, L.-M., Xu, Y., Wang, W., & Zhu, G. (2007) · Autonomic Neuroscience · doi:10.1016/j.autneu.2007.09.001 · Cited by 4
Jeong (2000) · doi:10.1002/(sici)1097-4636(200005)50:2
Cited by
Piech, D. K., Johnson, B. C., Shen, K., Ghanbari, M. M., Li, K. Y., Neely, R. M., Kay, J. E., Carmena, J. M., Maharbiz, M. M., & Muller, R. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-020-0518-9 · Cited by 442
Current Directions in the Auricular Vagus Nerve Stimulation I – A Physiological Perspective
Kaniusas, E., Kampusch, S., Tittgemeyer, M., Panetsos, F., Gines, R. F., Papa, M., Kiss, A., Podesser, B., Cassara, A. M., Tanghe, E., et al. (2019) · Frontiers in Neuroscience · doi:10.3389/fnins.2019.00854 · Cited by 323
Nanostructured platinum grass enables superior impedance reduction for neural microelectrodes
Boehler, C., Stieglitz, T., & Asplund, M. (2015) · Biomaterials · doi:10.1016/j.biomaterials.2015.07.036 · Cited by 179
“Current research addresses pain therapy by means of spinal cord stim ulation [2], deep brain stimulation to treat symptoms of Parkinson’s disease and severe psychiat ri disorders [3, 4], epilepsy diagnostics, artificial limb control [5], lost body function rep lacement [6] and modulation [7] or the development of brai…”
BackgroundSelf-citationA review for the peripheral nerve interface designer
Larson, C. E., & Meng, E. (2020) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2019.108523 · Cited by 133
Xiang, Z., Yen, S., Sheshadri, S., Wang, J., Lee, S., Liu, Y., Liao, L., Thakor, N. V., & Lee, C. (2016) · Advanced Materials · doi:10.1002/adma.201503423 · Cited by 116
Metadata
- Authors
- Plachta, D. T. T., Gierthmuehlen, M., Cota, O., Espinosa, N., Boeser, F., Herrera, T. C., Stieglitz, T., & Zentner, J.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2014-05-08
- Volume
- 11
- Issue
- 3
- Pages
- 036011
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2060718012
- Cited by
- 187
- References
- 42
- FWCI
- 5.48
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.