Blind source separation of peripheral nerve recordings
Open accessThe DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
Prosthetic devices can be controlled using signals recorded in parts of the body where sensation and/or voluntary movement have been retained. Although neural prosthetic applications have used single-channel recordings, multiple-channel recordings could provide a significant increase in useable control signals. Multiple control signals can be acquired from recordings of a single implant by using a multi-contact electrode placed over a multi-fasciculated peripheral nerve. These recordings can be separated to recover the individual fascicular signals. Blind source separation (BSS) algorithms have been developed to extract independent source signals from recordings of their mixtures. The hypothesis that BSS algorithms can recover individual fascicular signals from nerve cuff recordings at physiological signal-to-noise ratio (SNR approximately 3-10 dB) was investigated in this study using a finite-element model (FEM) of a beagle hypoglossal nerve with a flattening interface nerve electrode (FINE). Known statistical properties of fascicular signals were used to generate a set of four sources from which the neural signals recorded at the surface of the nerve with a multi-contact FINE were simulated. Independent component analysis (ICA) was then implemented for BSS of the simulated recordings. A novel post-ICA processing algorithm was developed to solve ICA's inherent permutation ambiguities. The similarity between the estimated and original fascicular signals was quantified by calculating their correlation coefficients. The mean values of the correlation coefficients calculated were higher than 0.95 (n = 50). The effects of the geometric layout of the FINE electrode and noise on the separation algorithm were also investigated. The results show that four distinct overlapping fascicular source signals can be simultaneously recovered from neural recordings obtained using a FINE with five or more contacts at SNR levels higher than 8 dB making them available for use as control signals.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Long-term stimulation and recording with a penetrating microelectrode array in cat sciatic nerve
Branner, A., Stein, R. B., Fernandez, E., Aoyagi, Y., & Normann, R. A. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.820321 · Cited by 301 · cited 2×
“The restoration of peripheral muscle control can be further improved by mimicking the body’s natural process of using sensory signals from muscle and tendon receptors to control the delivery of motor/stimulating signals [4, 21, 31, 42].”
BackgroundMethodA multielectrode array for intrafascicular recording and stimulation in sciatic nerve of cats
Branner, A., & Normann, R. A. (2000) · Brain Research Bulletin · doi:10.1016/s0361-9230(99)00231-2 · Cited by 234 · cited 1×
“In microneurography, selective recording is achieved by inserting the micro-tips of an electrode array, such as the Utah Slanted Electrode Array (USEA) or the longitudinal intrafascicular electrode (LIFE), directly into different fascicles [4, 5, 25, 26, 43].”
MethodModulation of Muscle Force by Recruitment During Intramuscular Stimulation
Crago, P. E., Peckham, P. H., & Thrope, G. B. (1980) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1980.326592 · Cited by 216
Chronically implanted intrafascicular recording electrodes
Lefurge, T., Goodall, E., Horch, K., Stensaas, L., & Schoenberg, A. (1991) · Annals of Biomedical Engineering · doi:10.1007/bf02368469 · Cited by 172 · cited 1×
“In microneurography, selective recording is achieved by inserting the micro-tips of an electrode array, such as the Utah Slanted Electrode Array (USEA) or the longitudinal intrafascicular electrode (LIFE), directly into different fascicles [4, 5, 25, 26, 43].”
MethodUpper airway response to electrical stimulation of the genioglossus in obstructive sleep apnea
Oliven, A., O'Hearn, D. J., Boudewyns, A., Odeh, M., De Backer, W., van de Heyning, P., Smith, P. L., Eisele, D. W., Allan, L., Schneider, H., et al. (2003) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00203.2003 · Cited by 158 · cited 1×
“FES of peripheral nerves has been applied to restore bladder continence [3, 13], to control upper and lower extremities [9, 27, 30, 35], and to treat respiratory disorders [10, 28, 44].”
BackgroundWaters, R. L., McNeal, D. R., Faloon, W., & Clifford, B. (1985) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198567050-00016 · Cited by 156
Selectivity of multiple-contact nerve cuff electrodes: a simulation analysis
Choi, A. Q., Cavanaugh, J. K., & Durand, D. M. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.909637 · Cited by 121
Self-citationAn intrafascicular electrode for recording of action potentials in peripheral nerves
Malagodi, M. S., Horch, K. W., & Schoenberg, A. A. (1989) · Annals of Biomedical Engineering · doi:10.1007/bf02368058 · Cited by 107
Yoo, P. B., & Durand, D. M. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.851482 · Cited by 106
Self-citationCuff electrodes for long-term recording of natural sensory information
Struijk, J. J., Thomsen, M., Larsen, J. O., & Sinkjaer, T. (1999) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.765194 · Cited by 97
Cited by
Control of Hand Prostheses Using Peripheral Information
Micera, S., Carpaneto, J., & Raspopovic, S. (2010) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2010.2085429 · Cited by 403
Double nerve intraneural interface implant on a human amputee for robotic hand control
Rossini, P. M., Micera, S., Benvenuto, A., Carpaneto, J., Cavallo, G., Citi, L., Cipriani, C., Denaro, L., Denaro, V., Di Pino, G., et al. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2010.01.001 · Cited by 396
“Peripheral nerve interfaces aim to detect electrical activity of the nerve fibres and/or to excite them as selectively as possible (Navarro et al., 2005; Stieglitz et al., 2005; Tesfayesus and Durand, 2007; Micera et al., 2008).”
BackgroundRaspopovic, S., Carpaneto, J., Udina, E., Navarro, X., & Micera, S. (2010) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-7-17 · Cited by 81
Localization and Recovery of Peripheral Neural Sources With Beamforming Algorithms
Wodlinger, B., & Durand, D. M. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2034072 · Cited by 73
“each signal is independent from the others [4], [5].”
BackgroundMethodResultInfluentialSelf-citationMotor-commands decoding using peripheral nerve signals: a review
Hong, K.-S., Aziz, N., & Ghafoor, U. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aab383 · Cited by 63
“Another source extraction algorithm has been developed and tested using cuff interface signals, called blind source sep aration [131].”
Method
Metadata
- Authors
- Tesfayesus, W., & Durand, D. M.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2007-06-25
- Volume
- 4
- Issue
- 3
- Pages
- S157-S167
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W1963822312
- Cited by
- 41
- References
- 13
- FWCI
- 1.69
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Blind source separation of peripheral nerve recordings. https://app.cochat.ai/papers/10.1088/1741-2560/4/3/s03
- The paper
- Tesfayesus, W., & Durand, D. M. (2007). Blind source separation of peripheral nerve recordings. Journal of Neural Engineering. https://doi.org/10.1088/1741-2560/4/3/s03
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.