CoChat

Blind source separation of peripheral nerve recordings

Open access
Tesfayesus, W, Durand, D M · 2007 · Journal of Neural Engineering
Cited by 41

The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.

Abstract

Prosthetic devices can be controlled using signals recorded in parts of the body where sensation and/or voluntary movement have been retained. Although neural prosthetic applications have used single-channel recordings, multiple-channel recordings could provide a significant increase in useable control signals. Multiple control signals can be acquired from recordings of a single implant by using a multi-contact electrode placed over a multi-fasciculated peripheral nerve. These recordings can be separated to recover the individual fascicular signals. Blind source separation (BSS) algorithms have been developed to extract independent source signals from recordings of their mixtures. The hypothesis that BSS algorithms can recover individual fascicular signals from nerve cuff recordings at physiological signal-to-noise ratio (SNR approximately 3-10 dB) was investigated in this study using a finite-element model (FEM) of a beagle hypoglossal nerve with a flattening interface nerve electrode (FINE). Known statistical properties of fascicular signals were used to generate a set of four sources from which the neural signals recorded at the surface of the nerve with a multi-contact FINE were simulated. Independent component analysis (ICA) was then implemented for BSS of the simulated recordings. A novel post-ICA processing algorithm was developed to solve ICA's inherent permutation ambiguities. The similarity between the estimated and original fascicular signals was quantified by calculating their correlation coefficients. The mean values of the correlation coefficients calculated were higher than 0.95 (n = 50). The effects of the geometric layout of the FINE electrode and noise on the separation algorithm were also investigated. The results show that four distinct overlapping fascicular source signals can be simultaneously recovered from neural recordings obtained using a FINE with five or more contacts at SNR levels higher than 8 dB making them available for use as control signals.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/1741-2560/4/3/s03

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 13 references

Cited by

Metadata

Authors
Tesfayesus, W., & Durand, D. M.
Venue
Journal of Neural Engineering
Published
2007-06-25
Volume
4
Issue
3
Pages
S157-S167
ISSN
  • 1741-2552 (ISSN-L)
  • 1741-2560
OpenAlex
W1963822312
Cited by
41
References
13
FWCI
1.69
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.