BACKGROUND: Lowering blood glucose concentration slows or prevents the development of complications in diabetes. One of the tools to control glucose levels is continuous glucose measurements. A promising technique involves measurements from glucose sensors implanted directly in skin/subcutis. However, in vivo bioinstability and drift in sensor signals have been reported after implantation, suggestively caused by the infiltration of inflammatory cells and adhesion of proteins to sensor membranes. The aim of this study was to evaluate the in vivo biocompatibility of two electrochemical glucose sensors after implantation in the skin of pigs. METHODS: In vivo biocompatibility of in-house fabricated electrochemical glucose sensors and a commercially available continuous glucose monitoring system (CGMS, Medtronic MiniMed, Northridge, CA) implanted 1 h, 2 h, 24 h, 3 days, or 7 days was examined by histological and immunohistochemical techniques. RESULTS: The extent of inflammation increased significantly as a function of time. The inflammation ranged from an acute focal fibrinous/suppurative dermatitis to a chronic fibrinous and granulating foreign body dermatitis 7 days after implantation. Immunohistochemical stainings showed that heterophilic granulocytes, macrophages, and fibrinogen/fibrinogen fragments D and E were consistent findings. Infiltration of CD3epsilon-positive T-cells was primarily confined to day 7 of implantation. In addition, the pro-inflammatory cytokines interleukin-1 and tumor necrosis factor-alpha played a role in the reaction to sensors. CONCLUSION: The reported in vivo bioinstability of sensors is likely to be caused by protein and cellular biofouling on the sensor membrane. Furthermore, the consistent finding of fibrinogen and fibrinogen fragments D and E at the sensor-tissue interface seems to play an important role in the pathogenesis as it possibly maintains the inflammation by promoting the recruitment of inflammatory cells to the implantation site.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1089/dia.2006.8.463

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

Metadata

Authors
Kvist, P. H., Iburg, T., Bielecki, M., Gerstenberg, M., Buch-Rasmussen, T., Hasselager, E., & Jensen, H. E.
Venue
Diabetes Technology & Therapeutics
Published
2006-08
Volume
8
Issue
4
Pages
463-475
ISSN
  • 1520-9156 (ISSN-L)
  • 1557-8593
OpenAlex
W2039214115
Cited by
38
References
6
FWCI
3.04
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.