Biocompatibility of an Enzyme-Based, Electrochemical Glucose Sensor for Short-Term Implantation in the Subcutis

Kvist, Peter Helding, Iburg, Tine, Aalbaek, Bent, Gerstenberg, Michael, Schoier, Christina, Kaastrup, Peter, Buch-Rasmussen, Thomas, Hasselager, Erik, Jensen, Henrik Elvang · 2006 · Diabetes Technology & Therapeutics
Cited by 38

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Continuous glucose measurements provide improved glycemic control and may prevent hypoglycemia and long-term complications of diabetes. One of the most promising techniques is the short-term implantation of electrochemical glucose sensors in subcutis. However, the inflammatory reaction to these sensors may lead to bioinstability of sensor measurements. The purpose of the present investigation was to examine factors contributing to the observed subcutaneous inflammatory reaction to an enzyme-based electrochemical glucose sensor for continuous glucose measurements. The sensor biocompatibility was assessed in vitro and in vivo. METHODS: A toxicological assessment was performed on sensor materials and leachables, and the endotoxin content of sensors was determined by a Limulus amoebocyte lysate (LAL) test. Moreover, as a consequence of permanent penetration of the skin by the sensor the role of bacterial migration to the tissue was investigated. In vivo biocompatibility was investigated through histological examination of implanted sensor membranes for 3 days in pigs. Additionally, the effect of needle size and type (normal vs. inserter needle) on tissue trauma at sensor insertion was evaluated, and the healing of subcutis was assessed histologically from 3 to 14 days after removal of sensors. RESULTS: The toxicological assessment and the LAL test showed no concerns in a 3-day implantation scenario, and bacterial migration to the subcutis could not be detected. The histological examination showed that a reduction in needle size reduced the extent of inflammation to very low levels, and that the different sensor membranes showed similar extent and type of inflammation. Additionally, the extent of subcutaneous tissue reaction after removal of sensors declined gradually over time and returned to near-normal levels after 2 weeks. CONCLUSION: The electrochemical enzyme-based glucose sensor for continuous glucose measurements in subcutis is acceptable from a biocompatibility point of view. Reducing the inserter needle in size reduces the trauma induced at sensor implantation to neglible levels. Furthermore, the tissue reaction to the sensor returns to near-normal 2 weeks after the sensor has been removed following a 3-day implantation period.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1089/dia.2006.8.546

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 38

Metadata

Authors
Kvist, P. H., Iburg, T., Aalbaek, B., Gerstenberg, M., Schoier, C., Kaastrup, P., Buch-Rasmussen, T., Hasselager, E., & Jensen, H. E.
Venue
Diabetes Technology & Therapeutics
Published
2006-10
Volume
8
Issue
5
Pages
546-559
ISSN
  • 1520-9156 (ISSN-L)
  • 1557-8593
OpenAlex
W1993174623
Cited by
38
References
6
FWCI
3.04
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.