Non-invasive continuous finger blood pressure measurement during orthostatic stress compared to intra-arterial pressure
The DOI matches its Crossref record.
Abstract
STUDY OBJECTIVE: The aim of the study was to evaluate whether invasive blood pressure responses to orthostatic stress can be replaced by non-invasive continuous finger blood pressure responses. DESIGN - Intrabrachial and Finapres blood pressures were simultaneously measured during passive head up tilt and during active standing from the supine or sitting position in healthy volunteers. SUBJECTS: Subjects (n = 11) were healthy males aged 22-40 years, mean age 30 years. MEASUREMENTS AND MAIN RESULTS: Beat to beat values of systolic, diastolic, and mean arterial pressures were calculated for both methods of measurement and the differences compared during a 30 s control period before, and during the first 120 s after, the change of posture. In the control period the difference between finger pressure and intra-arterial pressure was +2 (SD11) mm Hg for systolic, -4(8) mm Hg for mean, and -3(7) mm Hg for diastolic pressure. Compared to these control differences, the average finger minus intra-arterial pressure differences for mean and diastolic pressures during the three orthostatic manoeuvres were always within the range -6 to +6 mm Hg. The average systolic deviations were larger, ranging from -10 to +11 mm Hg. Despite these differences the characteristic changes in intra-arterial pressure during the initial phase (first 30 s after change of posture), as well as during the early steady state phase (1-2 min after the change of posture) were well reflected by finger pressure measurements in all subjects. CONCLUSIONS: For the assessment of the continuous blood pressure responses to orthostatic stress similar information can be obtained with non-invasive Finapres blood pressure recordings as with invasive recordings.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Vinik, A. I., Maser, R. E., Mitchell, B. D., & Freeman, R. (2003) · Diabetes Care · doi:10.2337/diacare.26.5.1553 · Cited by 2,044
Transfer function analysis of dynamic cerebral autoregulation in humans
Zhang, R., Zuckerman, J. H., Giller, C. A., & Levine, B. D. (1998) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1998.274.1.h233 · Cited by 848
Fifteen years experience with finger arterial pressure monitoring: assessment of the technology
Imholz, B. (1998) · Cardiovascular Research · doi:10.1016/s0008-6363(98)00067-4 · Cited by 834
Self-citationTilt table testing for assessing syncope
Benditt, D. G., Ferguson, D. W., Grubb, B. P., Kapoor, W. N., Kugler, J., Lerman, B. B., Maloney, J. D., Ravielle, A., Ross, B., Sutton, R., et al. (1996) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(96)00236-7 · Cited by 568
Spontaneous Cardiac Baroreflex in Humans: Comparison With Drug-Induced Responses
Parlow, J., Viale, J.-P., Annat, G., Hughson, R., & Quintin, L. (1995) · Hypertension · doi:10.1161/01.hyp.25.5.1058 · Cited by 392
Initial orthostatic hypotension: review of a forgotten condition
Wieling, W., Krediet, C. T. P., van Dijk, N., Linzer, M., & Tschakovsky, M. E. (2007) · Clinical Science · doi:10.1042/cs20060091 · Cited by 374
Self-citationReconstruction of Brachial Artery Pressure From Noninvasive Finger Pressure Measurements
Bos, W. J. W., van Goudoever, J., van Montfrans, G. A., van den Meiracker, A. H., & Wesseling, K. H. (1996) · Circulation · doi:10.1161/01.cir.94.8.1870 · Cited by 365
Self-citationHARMS, M. P. M., WESSELING, K. H., POTT, F., JENSTRUP, M., VAN GOUDOEVER, J., SECHER, N. H., & VAN LIESHOUT, J. J. (1999) · Clinical Science · doi:10.1042/cs0970291 · Cited by 345
Self-citationThe Role of Rumination in Recovery from Reactivity: Cardiovascular Consequences of Emotional States
Glynn, L. M. (2002) · Psychosomatic Medicine · doi:10.1097/01.psy.0000031574.42041.23 · Cited by 294
Noninvasive Continuous Arterial Blood Pressure Monitoring with Nexfin®
Martina, J. R., Westerhof, B. E., van Goudoever, J., de Beaumont, E. M. F. H., Truijen, J., Kim, Y.-S., Immink, R. V., Jöbsis, D. A., Hollmann, M. W., Lahpor, J. R., et al. (2012) · Anesthesiology · doi:10.1097/aln.0b013e31824f94ed · Cited by 292
Annane, Bellissant, Sebille, Lesieur, Mathieu, Raphael, & Gajdos (1998) · British Journal of Clinical Pharmacology · doi:10.1046/j.1365-2125.1998.00833.x · Cited by 291
Two sites for modulation of human sympathetic activity by arterial baroreceptors?
Kienbaum, P., Karlsson, T., Sverrisdottir, Y. B., Elam, M., & Wallin, B. G. (2001) · The Journal of Physiology · doi:10.1111/j.1469-7793.2001.0861h.x · Cited by 282
Feasibility of ambulatory, continuous 24-hour finger arterial pressure recording.
Imholz, B. P., Langewouters, G. J., van Montfrans, G. A., Parati, G., van Goudoever, J., Wesseling, K. H., Wieling, W., & Mancia, G. (1993) · Hypertension · doi:10.1161/01.hyp.21.1.65 · Cited by 259
Self-citationMidodrine: a role in the management of neurocardiogenic syncope
Ward, C. R., Gray, J. C., Gilroy, J. J., & Kenny, R. A. (1998) · Heart · doi:10.1136/hrt.79.1.45 · Cited by 249
McIntosh, S. J., Lawson, J., & Kenny, R. A. (1993) · The American Journal of Medicine · doi:10.1016/0002-9343(93)90261-m · Cited by 238
Guzik, P., Piskorski, J., Krauze, T., Schneider, R., Wesseling, K. H., Wykretowicz, A., & Wysocki, H. (2007) · The Journal of Physiological Sciences · doi:10.2170/physiolsci.rp005506 · Cited by 232
Self-citationWilhelm, F. H., Kochar, A. S., Roth, W. T., & Gross, J. J. (2001) · Biological Psychology · doi:10.1016/s0301-0511(01)00113-2 · Cited by 223
“These measurements have been previously validated (Gratz et al., 1992; Imholz et al., 1990; Stok et al., 1993).”
Nexfin Noninvasive Continuous Blood Pressure Validated Against Riva-Rocci/Korotkoff
Eeftinck Schattenkerk, D. W., van Lieshout, J. J., van den Meiracker, A. H., Wesseling, K. R., Blanc, S., Wieling, W., van Montfrans, G. A., Settels, J. J., Wesseling, K. H., & Westerhof, B. E. (2009) · American Journal of Hypertension · doi:10.1038/ajh.2008.368 · Cited by 222
Self-citationContinuous non-invasive blood pressure monitoring using concentrically interlocking control loops
Fortin, J., Marte, W., Grüllenberger, R., Hacker, A., Habenbacher, W., Heller, A., Wagner, C., Wach, P., & Skrabal, F. (2006) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2005.04.003 · Cited by 192
Hypocapnia and Cerebral Hypoperfusion in Orthostatic Intolerance
Novak, V., Spies, J. M., Novak, P., McPhee, B. R., Rummans, T. A., & Low, P. A. (1998) · Stroke · doi:10.1161/01.str.29.9.1876 · Cited by 191
Continuous finger arterial pressure: Utility in the cardiovascular laboratory
Imholz, B. P. M., Wieling, W., Langewouters, G. J., & van Montfrans, G. A. (1991) · Clinical Autonomic Research · doi:10.1007/bf01826057 · Cited by 181
Self-citationPhysiologic instability in panic disorder and generalized anxiety disorder
Wilhelm, F. H., Trabert, W., & Roth, W. T. (2001) · Biological Psychiatry · doi:10.1016/s0006-3223(00)01000-3 · Cited by 180
Zhang, R., Zuckerman, J. H., & Levine, B. D. (1998) · Journal of Applied Physiology · doi:10.1152/jappl.1998.85.3.1113 · Cited by 161
“The accuracy and reliability of this technique for recording of arterial pressure have been evaluated in numerous studies (19, 30).”
Smit, A. J., Wieling, W., Fujimura, J., Denq, J., Opfer-Gehrking, T., Akarriou, M., Karemaker, J., & Low, P. (2004) · Clinical Autonomic Research · doi:10.1007/s10286-004-0187-x · Cited by 153
Self-citationPhysical manoeuvres for combating orthostatic dizziness in autonomic failure
van Lieshout, J. J., ten Harkel, A. D. J., & Wieling, W. (1992) · The Lancet · doi:10.1016/0140-6736(92)90932-s · Cited by 153
Self-citationHARKEL, A. D. J. T., VAN LIESHOUT, J. J., & WIELING, W. (1992) · Journal of Internal Medicine · doi:10.1111/j.1365-2796.1992.tb00563.x · Cited by 151
Self-citationvan Lieshout, J. J., ten Harkel, A. D. J., & Wieling, W. (2000) · Clinical Autonomic Research · doi:10.1007/bf02291388 · Cited by 144
Self-citationPhysical manoeuvres that reduce postural hypotension in autonomic failure
Wieling, W., van Lieshout, J. J., & van Leeuwen, A. M. (1993) · Clinical Autonomic Research · doi:10.1007/bf01819146 · Cited by 140
Self-citationTen Harkel, A. D. J., Van Lieshout, J. J., & Wieling, W. (1994) · Clinical Science · doi:10.1042/cs0870553 · Cited by 128
Self-citationLow, P. A., Opfer-Gehrking, T. L., Textor, S. C., Schondorf, R., Suarez, G. A., Fealey, R. D., & Camilleri, M. (1994) · Journal of the Autonomic Nervous System · doi:10.1016/0165-1838(94)90008-6 · Cited by 105
Cardiovascular regulation in the period preceding vasovagal syncope in conscious humans
Julu, P. O. O., Cooper, V. L., Hansen, S., & Hainsworth, R. (2003) · The Journal of Physiology · doi:10.1113/jphysiol.2002.036715 · Cited by 105
The normal response to prolonged passive head up tilt testing
Petersen, M. E. V., Williams, T. R., Gordon, C., Chamberlain-Webber, R., & Sutton, R. (2000) · Heart · doi:10.1136/heart.84.5.509 · Cited by 85
Cerebral hemodynamics during orthostatic stress assessed by nonlinear modeling
Mitsis, G. D., Zhang, R., Levine, B. D., & Marmarelis, V. Z. (2006) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00548.2005 · Cited by 76
Metadata
- Authors
- Imholz, B. P. M., Settels, J. J., van der Meiracker, A. H., Wesseling, K. H., & Wieling, W.
- Venue
- Cardiovascular Research
- Publisher
- Oxford University Press (OUP)
- Published
- 1990-03-01
- Volume
- 24
- Issue
- 3
- Pages
- 214-221
- ISSN
- 0008-6363 (ISSN-L)
- OpenAlex
- W2090528555
- Cited by
- 344
- References
- 0
- FWCI
- 15.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.