Selecting patients for cardiac resynchronization therapy: electrical or mechanical dyssynchrony?
The DOI matches its Crossref record; 67 of the 67 references it cites were found in a registry or an index.
Abstract
Cardiac resynchronization therapy (CRT) markedly reduces morbidity and mortality in patients with heart failure and prolonged QRS duration. Landmark trials have included over 4000 patients based on their electrocardiogram. A few small, observational, non-randomized, single centre studies of short duration have suggested that echocardiographic measurement of mechanical dyssynchrony may better identify patients likely to benefit from CRT. We objectively review the meaning and measurement of electrical and mechanical dyssynchrony, the strengths and weaknesses of echocardiographic indices of dyssynchrony, and the controversial issue of predicting response to treatment. We conclude that proposals to alter current guidelines for patient selection, and include echocardiography, are misguided. Echocardiographic assessment will only become credible and applicable to clinical practice once used to select patients for large prospective randomized trials which show an improvement in clinical outcome.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Effect of Cardiac Resynchronization on Morbidity and Mortality in Heart Failure
Cleland, J. G. F., Daubert, J.-C., Erdmann, E., Freemantle, N., Gras, D., Kappenberger, L., & Tavazzi, L. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa050496 · Cited by 6,276
Bristow, M. R., Saxon, L. A., Boehmer, J., Krueger, S., Kass, D. A., De Marco, T., Carson, P., DiCarlo, L., DeMets, D., White, B. G., et al. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa032423 · Cited by 5,812
Cardiac Resynchronization in Chronic Heart Failure
Abraham, W. T., Fisher, W. G., Smith, A. L., Delurgio, D. B., Leon, A. R., Loh, E., Kocovic, D. Z., Packer, M., Clavell, A. L., Hayes, D. L., et al. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa013168 · Cited by 4,648
CARDIAC RESYNCHRONIZATION IN CHRONIC HEART FAILURE
Braham, W. I. T. A., Isher, W. E. G. F., Mith, L. S., Elurgio, D. A. B. D., Eon, A. N. R. L., Oh, E., Ocovic, D. U. Z. K., Acker, M. G., Lavell, L. C., Ayes, D. A. L. H., et al. (2002) · Cited by 3,808
Cazeau, S., Leclercq, C., Lavergne, T., Walker, S., Varma, C., Linde, C., Garrigue, S., Kappenberger, L., Haywood, G. A., Santini, M., et al. (2001) · New England Journal of Medicine · doi:10.1056/nejm200103223441202 · Cited by 2,751
Guidelines for the diagnosis and treatment of chronic heart failure: executive summary (update 2005)
Swedberg, K., Cleland, J., Dargie, H., Drexler, H., Follath, F., Komajda, M., Tavazzi, L., Smiseth, O. A., Gavazzi, A., Haverich, A., et al. (2005) · European Heart Journal · doi:10.1093/eurheartj/ehi204 · Cited by 2,260
Young, J. B., Abraham, W. T., & Smith, A. L. (2003) · ACC Current Journal Review · doi:10.1016/j.accreview.2003.08.087 · Cited by 1,682
Bristow, M. R., Gilbert, E. M., Abraham, W. T., Adams, K. F., Fowler, M. B., Hershberger, R. E., Kubo, S. H., Narahara, K. A., Ingersoll, H., Krueger, S., et al. (1996) · Circulation · doi:10.1161/01.cir.94.11.2807 · Cited by 1,303
Auricchio, A., Stellbrink, C., Block, M., Sack, S., Vogt, J., Bakker, P., Klein, H., Kramer, A., Ding, J., Salo, R., et al. (1999) · Circulation · doi:10.1161/01.cir.99.23.2993 · Cited by 1,152
St John Sutton, M. G., Plappert, T., Abraham, W. T., Smith, A. L., DeLurgio, D. B., Leon, A. R., Loh, E., Kocovic, D. Z., Fisher, W. G., Ellestad, M., et al. (2003) · Circulation · doi:10.1161/01.cir.0000065226.24159.e9 · Cited by 1,124
Yu, C.-M., Chau, E., Sanderson, J. E., Fan, K., Tang, M.-O., Fung, W.-H., Lin, H., Kong, S.-L., Lam, Y.-M., Hill, M. R. S., et al. (2002) · Circulation · doi:10.1161/hc0402.102623 · Cited by 1,110
Bax, J. J., Bleeker, G. B., Marwick, T. H., Molhoek, S. G., Boersma, E., Steendijk, P., van der Wall, E. E., & Schalij, M. J. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.08.016 · Cited by 1,062
Auricchio, A., Stellbrink, C., Sack, S., Block, M., Vogt, J. Ü., Bakker, P., Huth, C., Schöndube, F., Wolfhard, U., Böcker, D., et al. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)01895-8 · Cited by 1,026
D'hooge, J. (2000) · European Journal of Echocardiography · doi:10.1053/euje.2000.0031 · Cited by 990
Kass, D. A., Chen, C.-H., Curry, C., Talbot, M., Berger, R., Fetics, B., & Nevo, E. (1999) · Circulation · doi:10.1161/01.cir.99.12.1567 · Cited by 972
Baldasseroni, S., Opasich, C., Gorini, M., Lucci, D., Marchionni, N., Marini, M., Campana, C., Perini, G., Deorsola, A., Masotti, G., et al. (2002) · American Heart Journal · doi:10.1067/mhj.2002.121264 · Cited by 800
Cardiac resynchronization therapy tailored by echocardiographic evaluation of ventricular asynchrony
Pitzalis, M. V., Iacoviello, M., Romito, R., Massari, F., Rizzon, B., Luzzi, G., Guida, P., Andriani, A., Mastropasqua, F., & Rizzon, P. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)02337-9 · Cited by 716
Higgins, S. L., Hummel, J. D., Niazi, I. K., Giudici, M. C., Worley, S. J., Saxon, L. A., Boehmer, J. P., Higginbotham, M. B., De Marco, T., Foster, E., et al. (2003) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(03)01042-8 · Cited by 712
Yu, C.-M., Fung, W.-H., Lin, H., Zhang, Q., Sanderson, J. E., & Lau, C.-P. (2003) · The American Journal of Cardiology · doi:10.1016/s0002-9149(02)03404-5 · Cited by 649
Blanc, J.-J., Etienne, Y., Gilard, M., Mansourati, J., Munier, S., Boschat, J., Benditt, D. G., & Lurie, K. G. (1997) · Circulation · doi:10.1161/01.cir.96.10.3273 · Cited by 641
Yu, C.-M., Fung, J. W.-H., Zhang, Q., Chan, C.-K., Chan, Y.-S., Lin, H., Kum, L. C. C., Kong, S.-L., Zhang, Y., & Sanderson, J. E. (2004) · Circulation · doi:10.1161/01.cir.0000133276.45198.a5 · Cited by 624
Yu, C.-M., Lin, H., Zhang, Q., & Sanderson, J. E. (2003) · Heart · doi:10.1136/heart.89.1.54 · Cited by 618
Søgaard, P., Egeblad, H., Kim, W. Y., Jensen, H. K., Pedersen, A. K., Kristensen, B. Ø., & Mortensen, P. T. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)02010-7 · Cited by 603
Abraham, W. T., Young, J. B., León, A. R., Adler, S., Bank, A. J., Hall, S. A., Lieberman, R., Liem, L. B., O’Connell, J. B., Schroeder, J. S., et al. (2004) · Circulation · doi:10.1161/01.cir.0000146336.92331.d1 · Cited by 559
Acute hemodynamic effects of biventricular DDD pacing in patients with end-stage heart failure
Leclercq, C., Cazeau, S., Le Breton, H., Ritter, P., Mabo, P., Gras, D., Pavin, D., Lazarus, A., & Daubert, J.-C. (1998) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(98)00492-6 · Cited by 533
Breithardt, O. A., Sinha, A. M., Schwammenthal, E., Bidaoui, N., Markus, K. U., Franke, A., & Stellbrink, C. (2003) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)02937-6 · Cited by 517
Ansalone, G., Giannantoni, P., Ricci, R., Trambaiolo, P., Fedele, F., & Santini, M. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(01)01772-7 · Cited by 481
Intra-left ventricular electromechanical asynchrony
Bader, H., Garrigue, S., Lafitte, S., Reuter, S., Jaïs, P., Haïssaguerre, M., Bonnet, J., Clementy, J., & Roudaut, R. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2003.08.038 · Cited by 473
Cardiac Resynchronization Therapy
Bax, J. J., Abraham, T., Barold, S. S., Breithardt, O. A., Fung, J. W. H., Garrigue, S., Gorcsan, J., Hayes, D. L., Kass, D. A., Knuuti, J., et al. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.09.019 · Cited by 463
Leclercq, C. (2002) · European Heart Journal · doi:10.1053/euhj.2002.3232 · Cited by 452
Bax, J. J., Marwick, T. H., Molhoek, S. G., Bleeker, G. B., van Erven, L., Boersma, E., Steendijk, P., van der Wall, E. E., & Schalij, M. J. (2003) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2003.06.016 · Cited by 429
BLEEKER, G. B., SCHALIJ, M. J., MOLHOEK, S. G., VERWEY, H. F., HOLMAN, E. R., BOERSMA, E., STEENDIJK, P., VAN DER WALL, E. E., & BAX, J. J. (2004) · Journal of Cardiovascular Electrophysiology · doi:10.1046/j.1540-8167.2004.03604.x · Cited by 425
Stellbrink, C., Breithardt, O.-A., Franke, A., Sack, S., Bakker, P., Auricchio, A., Pochet, T., Salo, R., Kramer, A., & Spinelli, J. (2001) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(01)01637-0 · Cited by 410
Auricchio, A., Stellbrink, C., Butter, C., Sack, S., Vogt, J., Misier, A. R., Böcker, D., Block, M., Kirkels, J. H., Kramer, A., et al. (2003) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2003.04.003 · Cited by 409
Penicka, M., Bartunek, J., De Bruyne, B., Vanderheyden, M., Goethals, M., De Zutter, M., Brugada, P., & Geelen, P. (2004) · Circulation · doi:10.1161/01.cir.0000116765.43251.d7 · Cited by 405
Packer, M. (2001) · Journal of Cardiac Failure · doi:10.1054/jcaf.2001.25652 · Cited by 396
Yu, C.-M., Zhang, Q., Fung, J. W.-H., Chan, H. C.-K., Chan, Y.-S., Yip, G. W.-K., Kong, S.-L., Lin, H., Zhang, Y., & Sanderson, J. E. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.12.003 · Cited by 386
GHIO, S. (2004) · European Heart Journal · doi:10.1016/j.ehj.2003.09.030 · Cited by 338
Cleland, J. G. F., Daubert, J. C., Erdmann, E., Freemantle, N., Gras, D., Kappenberger, L., Klein, W., Tavazzi, L., & The CARE-HF study Steering Committee and Investigators (2001) · European Journal of Heart Failure · doi:10.1016/s1388-9842(01)00176-3 · Cited by 323
Reuter, S., Garrigue, S., Barold, S. S., Jaïs, P., Hocini, M., Haïssaguerre, M., & Clémenty, J. (2002) · The American Journal of Cardiology · doi:10.1016/s0002-9149(01)02240-8 · Cited by 307
Saxon, L. A., De Marco, T., Schafer, J., Chatterjee, K., Kumar, U. N., & Foster, E. (2002) · Circulation · doi:10.1161/hc1102.105730 · Cited by 292
Gorcsan, J., Kanzaki, H., Bazaz, R., Dohi, K., & Schwartzman, D. (2004) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2004.01.054 · Cited by 285
Pitzalis, M. V., Iacoviello, M., Romito, R., Guida, P., De Tommasi, E., Luzzi, G., Anaclerio, M., Forleo, C., & Rizzon, P. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.09.058 · Cited by 284
Alonso, C., Leclercq, C., Victor, F., Mansour, H., de Place, C., Pavin, D., Carré, F., Mabo, P., & Daubert, J. C. (1999) · The American Journal of Cardiology · doi:10.1016/s0002-9149(99)00588-3 · Cited by 269
Congestive Heart Failure and QRS Duration
Shenkman, H. J., Pampati, V., Khandelwal, A. K., McKinnon, J., Nori, D., Kaatz, S., Sandberg, K. R., & McCullough, P. A. (2002) · Chest · doi:10.1378/chest.122.2.528 · Cited by 250
Lecoq, G., Leclercq, C., Leray, E., Crocq, C., Alonso, C., Place, C. D., Mabo, P., & Daubert, C. (2005) · European Heart Journal · doi:10.1093/eurheartj/ehi146 · Cited by 246
Breithardt, O.-A., Stellbrink, C., Herbots, L., Claus, P., Sinha, A. M., Bijnens, B., Hanrath, P., & Sutherland, G. R. (2003) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(03)00709-5 · Cited by 244
Cardiac Resynchronization Therapy
KASS, D. A. (2005) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2005.50136.x · Cited by 228
Predictors of Lack of Response to Resynchronization Therapy
Díaz-Infante, E., Mont, L., Leal, J., García-Bolao, I., Fernández-Lozano, I., Hernández-Madrid, A., Pérez-Castellano, N., Sitges, M., Pavón-Jiménez, R., Barba, J., et al. (2005) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2005.02.009 · Cited by 226
Predictors of response to cardiac resynchronization therapy (PROSPECT)—study design
Yu, C.-M., Abraham, W. T., Bax, J., Chung, E., Fedewa, M., Ghio, S., Leclercq, C., León, A. R., Merlino, J., Nihoyannopoulos, P., et al. (2005) · American Heart Journal · doi:10.1016/j.ahj.2004.12.013 · Cited by 221
CAZEAU, S., BORDACHAR, P., JAUVERT, G., LAZARUS, A., ALONSO, C., VANDRELL, M. C., MUGICA, J., & RITTER, P. (2003) · Pacing and Clinical Electrophysiology · doi:10.1046/j.1460-9592.2003.00003.x · Cited by 217
Bax, J. J., Molhoek, S. G., van Erven, L., Voogd, P. J., Somer, S., Boersma, E., Steendijk, P., Schalij, M. J., & Van der Wall, E. E. (2003) · The American Journal of Cardiology · doi:10.1016/s0002-9149(02)03009-6 · Cited by 206
MOLHOEK, S. G., BAX, J. J., BOERSMA, E., ERVEN, L. V., BOOTSMA, M., STEENDIJK, P., VAN DER WALL, E. E., & SCHALIJ, M. J. (2004) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2004.00433.x · Cited by 185
Notabartolo, D., Merlino, J. D., Smith, A. L., DeLurgio, D. B., Vera, F. V., Easley, K. A., Martin, R. P., & León, A. R. (2004) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2004.05.072 · Cited by 180
Strain and strain rate echocardiography
Pislaru, C., Abraham, T. P., & Bëlohlávek, M. (2002) · Current Opinion in Cardiology · doi:10.1097/00001573-200209000-00002 · Cited by 152
Dohi, K., Suffoletto, M. S., SCHWARTZMAN, D. S., Ganz, L. I., Pinsky, M. R., & Gorcsan, J. (2005) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2005.03.032 · Cited by 151
Understanding Nonresponders of Cardiac Resynchronization Therapy—Current and Future Perspectives
Yu, C., Fung, J. W., Zhang, Q., & Sanderson, J. E. (2005) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2005.40829.x · Cited by 142
Marcus, G. M., Rose, E., Viloria, E., Schafer, J. E., Marco, T. D., Saxon, L. A., & Foster, E. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.05.095 · Cited by 135
Duncan, A. (2003) · European Heart Journal · doi:10.1016/s0195-668x(02)00475-x · Cited by 118
Is the Outcome of Cardiac Resynchronization Therapy Related to the Underlying Etiology?
Gasparini, M., Mantica, M., Galimberti, P., Genovese, L., Pini, D., Faletra, F. F., Marchesina, U. L., Mangiavacchi, M., Klersy, C., & Gronda, E. (2003) · Pacing and Clinical Electrophysiology · doi:10.1046/j.1460-9592.2003.00011.x · Cited by 114
Søgaard, P., Kim, W. Y., Jensen, H. K., Mortensen, P. T., Pedersen, A. K., Kristensen, B. Ø., & Egeblad, H. (2001) · Cardiology · doi:10.1159/000047369 · Cited by 101
Auricchio, A., Kloss, M., Trautmann, S. I., Rodner, S., & Klein, H. (2002) · The American Journal of Cardiology · doi:10.1016/s0002-9149(01)02200-7 · Cited by 99
Reversal of Left Ventricular Remodeling by Synchronous Biventricular Pacing in Heart Failure
Lau, C., Yu, C., Chau, E. M. C., FAN, K., Tse, H., Lee, K., TANG, M., Wan, S.-H., Law, T., Lee, P., et al. (2000) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2000.tb07004.x · Cited by 91
YU, C., FUNG, J. W., CHAN, C., CHAN, Y., ZHANG, Q., LIN, H., YIP, G. W. K., KUM, L. C. C., KONG, S., ZHANG, Y., et al. (2004) · Journal of Cardiovascular Electrophysiology · doi:10.1046/j.1540-8167.2004.03648.x · Cited by 79
Bundle branch block patterns, age, renal dysfunction, and heart failure mortality
McCullough, P. A., Hassan, S. A., Pallekonda, V., Sandberg, K. R., Nori, D. B., Soman, S. S., Bhatt, S., Hudson, M. P., & Weaver, W. D. (2005) · International Journal of Cardiology · doi:10.1016/j.ijcard.2004.10.008 · Cited by 62
Auricchio, A., & Yu, C. M. (2004) · Heart · doi:10.1136/hrt.2003.024273 · Cited by 59
Sun, J. P., Chinchoy, E. C., Donal, E., Popović, Z., Perlic, G., Asher, C. R., Greenberg, N. L., Grimm, R. A., Wilkoff, B. L., & Thomas, J. D. (2004) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2004.04.012 · Cited by 45
Cited by
Authors/Task Force Members, Vardas, P. E., Auricchio, A., Blanc, J.-J., Daubert, J.-C., Drexler, H., Ector, H., Gasparini, M., Linde, C., Morgado, F. B., et al. (2007) · European Heart Journal · doi:10.1093/eurheartj/ehm305 · Cited by 902
Cardiac-Resynchronization Therapy in Heart Failure with a Narrow QRS Complex
Ruschitzka, F., Abraham, W. T., Singh, J. P., Bax, J. J., Borer, J. S., Brugada, J., Dickstein, K., Ford, I., Gorcsan, J., Gras, D., et al. (2013) · New England Journal of Medicine · doi:10.1056/nejmoa1306687 · Cited by 825
Biomaterials in cardiac tissue engineering: Ten years of research survey
Chen, Q.-Z., Harding, S. E., Ali, N. N., Lyon, A. R., & Boccaccini, A. R. (2008) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2007.08.001 · Cited by 382
Authors/Task Force Members, Vardas, P. E., Auricchio, A., Blanc, J.-J., Daubert, J.-C., Drexler, H., Ector, H., Gasparini, M., Linde, C., Morgado, F. B., et al. (2007) · Europace · doi:10.1093/europace/eum189 · Cited by 291
Gervais, R., Leclercq, C., Shankar, A., Jacobs, S., Eiskjær, H., Johannessen, A., Freemantle, N., Cleland, J. G. F., Tavazzi, L., & Daubert, C. (2009) · European Journal of Heart Failure · doi:10.1093/eurjhf/hfp074 · Cited by 243
“While imperfect, this electrocardiographic (ECG) marker is currently the only accepted marker of cardiac dyssynchrony for the selection of CRT candidates.(10) However, whether QRS duration measured during spontaneous rhythm or during biventricular stimulation predicts the response to CRT, thus far based only on observ…”
Background
Metadata
- Authors
- Hawkins, N. M., Petrie, M. C., MacDonald, M. R., Hogg, K. J., & McMurray, J. J. V.
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 2006-03-09
- Volume
- 27
- Issue
- 11
- Pages
- 1270-1281
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- OpenAlex
- W2162911128
- Cited by
- 196
- References
- 67
- FWCI
- 17.50
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.