Polysurgery of cell sheet grafts overcomes diffusion limits to produce thick, vascularized myocardial tissues
The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
Recently, the field of tissue engineering has progressed rapidly, but poor vascularization remains a major obstacle in bioengineering cell‐dense tissues, limiting the viable size of constructs due to hypoxia, nutrient insufficiency, and waste accumulation. Therefore, new technologies for fabricating functional tissues with a well‐organized vasculature are required. In the present study, neonatal rat cardiomyocytes were harvested as intact sheets from temperature‐responsive culture dishes and stacked into cell‐dense myocardial tissues. However, the thickness limit for layered cell sheets in subcutaneous tissue was ~80 μm (3 layers). To overcome this limitation, repeated transplantation of triple‐layer grafts was performed at 1, 2, or 3 day intervals. The two overlaid grafts completely synchronized and the whole tissues survived without necrosis in the 1 or 2 day interval cases. Multistep transplantation also created ~1 mm thick myocardium with a well‐organized microvascular network. Furthermore, functional multilayer grafts fabricated over a surgically connectable artery and vein revealed complete graft perfusion via the vessels and ectopic transplantation of the grafts was successfully performed using direct vessel anastomoses. These cultured cell sheet integration methods overcome long‐standing barriers to producing thick, vascularized tissues, revealing a possible solution for the clinical repair of various damaged organs, including the impaired myocardium.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Langer, R., & Vacanti, J. P. (1993) · Science · doi:10.1126/science.8493529 · Cited by 9,893
Treatment of Deep Cartilage Defects in the Knee with Autologous Chondrocyte Transplantation
Brittberg, M., Lindahl, A., Nilsson, A., Ohlsson, C., Isaksson, O., & Peterson, L. (1994) · New England Journal of Medicine · doi:10.1056/nejm199410063311401 · Cited by 5,516
Biomimetic materials for tissue engineering
Shin, H., Jo, S., & Mikos, A. G. (2003) · Biomaterials · doi:10.1016/s0142-9612(03)00339-9 · Cited by 1,612
Nishida, K., Yamato, M., Hayashida, Y., Watanabe, K., Yamamoto, K., Adachi, E., Nagai, S., Kikuchi, A., Maeda, N., Watanabe, H., et al. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa040455 · Cited by 1,513
Self-citationOkano, T., Yamada, N., Sakai, H., & Sakurai, Y. (1993) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820271005 · Cited by 1,020
Self-citationThermo‐responsive polymeric surfaces; control of attachment and detachment of cultured cells
Yamada, N., Okano, T., Sakai, H., Karikusa, F., Sawasaki, Y., & Sakurai, Y. (1990) · Die Makromolekulare Chemie, Rapid Communications · doi:10.1002/marc.1990.030111109 · Cited by 983
Self-citationShimizu, T., Yamato, M., Isoi, Y., Akutsu, T., Setomaru, T., Abe, K., Kikuchi, A., Umezu, M., & Okano, T. (2002) · Circulation Research · doi:10.1161/hh0302.105722 · Cited by 956
Self-citationTissue Engineering of a Differentiated Cardiac Muscle Construct
Zimmermann, W.-H., Schneiderbanger, K., Schubert, P., Didié, M., Münzel, F., Heubach, J. F., Kostin, S., Neuhuber, W. L., & Eschenhagen, T. (2002) · Circulation Research · doi:10.1161/hh0202.103644 · Cited by 917
Cao, Y., Vacanti, J. P., Paige, K. T., Upton, J., & Vacanti, C. A. (1997) · Plastic & Reconstructive Surgery · doi:10.1097/00006534-199708000-00001 · Cited by 749
Cell sheet engineering for myocardial tissue reconstruction
Shimizu, T., Yamato, M., Kikuchi, A., & Okano, T. (2003) · Biomaterials · doi:10.1016/s0142-9612(03)00110-8 · Cited by 673
Self-citation
Cited by
Scaffolding in tissue engineering: general approaches and tissue-specific considerations
Chan, B. P., & Leong, K. W. (2008) · European Spine Journal · doi:10.1007/s00586-008-0745-3 · Cited by 1,708
“Multisurgeries such as 10 layers to form a 300 lm thick myocardial patch are required [104, 105].”
MethodVascularization Strategies for Tissue Engineering
Lovett, M., Lee, K., Edwards, A., & Kaplan, D. L. (2009) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2009.0085 · Cited by 923
Accordion-like honeycombs for tissue engineering of cardiac anisotropy
Engelmayr, G. C., Cheng, M., Bettinger, C. J., Borenstein, J. T., Langer, R., & Freed, L. E. (2008) · Nature Materials · doi:10.1038/nmat2316 · Cited by 848
“Although ∼250-μm-thick honeycomb scaffolds provide a model for systematic in vitro studies, they are too thin to address reconstruction of full-thickness myocardium, except perhaps through a polysurgery strateg”
Tissue engineering by self-assembly and bio-printing of living cells
Jakab, K., Norotte, C., Marga, F., Murphy, K., Vunjak-Novakovic, G., & Forgacs, G. (2010) · Biofabrication · doi:10.1088/1758-5082/2/2/022001 · Cited by 593
Challenges in Cardiac Tissue Engineering
Vunjak-Novakovic, G., Tandon, N., Godier, A., Maidhof, R., Marsano, A., Martens, T. P., & Radisic, M. (2010) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2009.0352 · Cited by 511
Kawamura, M., Miyagawa, S., Miki, K., Saito, A., Fukushima, S., Higuchi, T., Kawamura, T., Kuratani, T., Daimon, T., Shimizu, T., et al. (2012) · Circulation · doi:10.1161/circulationaha.111.084343 · Cited by 495
Self-citationReconstruction of functional tissues with cell sheet engineering
Yang, J., Yamato, M., Shimizu, T., Sekine, H., Ohashi, K., Kanzaki, M., Ohki, T., Nishida, K., & Okano, T. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.07.052 · Cited by 482
Self-citationIn vitro fabrication of functional three-dimensional tissues with perfusable blood vessels
Sekine, H., Shimizu, T., Sakaguchi, K., Dobashi, I., Wada, M., Yamato, M., Kobayashi, E., Umezu, M., & Okano, T. (2013) · Nature Communications · doi:10.1038/ncomms2406 · Cited by 445
Self-citationThermoresponsive polymers and their biomedical application in tissue engineering – a review
Doberenz, F., Zeng, K., Willems, C., Zhang, K., & Groth, T. (2020) · Journal of Materials Chemistry B · doi:10.1039/c9tb02052g · Cited by 427
Cardiac Tissue Engineering: State of the Art
Hirt, M. N., Hansen, A., & Eschenhagen, T. (2014) · Circulation Research · doi:10.1161/circresaha.114.300522 · Cited by 425
Tissue Engineering Based on Cell Sheet Technology
Matsuda, N., Shimizu, T., Yamato, M., & Okano, T. (2007) · Advanced Materials · doi:10.1002/adma.200701978 · Cited by 398
Self-citationNagase, K., Yamato, M., Kanazawa, H., & Okano, T. (2018) · Biomaterials · doi:10.1016/j.biomaterials.2017.10.026 · Cited by 393
Self-citationFabrication of functional three-dimensional tissues by stacking cell sheets in vitro
Haraguchi, Y., Shimizu, T., Sasagawa, T., Sekine, H., Sakaguchi, K., Kikuchi, T., Sekine, W., Sekiya, S., Yamato, M., Umezu, M., et al. (2012) · Nature Protocols · doi:10.1038/nprot.2012.027 · Cited by 385
Self-citationIwata, T., Yamato, M., Tsuchioka, H., Takagi, R., Mukobata, S., Washio, K., Okano, T., & Ishikawa, I. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2009.01.032 · Cited by 380
Self-citationThermo-responsive polymers: Applications of smart materials in drug delivery and tissue engineering
Sponchioni, M., Capasso Palmiero, U., & Moscatelli, D. (2019) · Materials Science and Engineering: C · doi:10.1016/j.msec.2019.04.069 · Cited by 369
The Pivotal Role of Vascularization in Tissue Engineering
Auger, F. A., Gibot, L., & Lacroix, D. (2013) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071812-152428 · Cited by 334
Organ-on-a-chip platforms: a convergence of advanced materials, cells, and microscale technologies
Ahadian, S., Civitarese, R., Bannerman, D., Mohammadi, M. H., Lu, R., Wang, E., Davenport‐Huyer, L., Lai, B., Zhang, B., Zhao, Y., et al. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201700506 · Cited by 315
Biomatrices and biomaterials for future developments of bioprinting and biofabrication
Nakamura, M., Iwanaga, S., Henmi, C., Arai, K., & Nishiyama, Y. (2010) · Biofabrication · doi:10.1088/1758-5082/2/1/014110 · Cited by 311
In Vitro Engineering of Vascularized Tissue Surrogates
Sakaguchi, K., Shimizu, T., Horaguchi, S., Sekine, H., Yamato, M., Umezu, M., & Okano, T. (2013) · Scientific Reports · doi:10.1038/srep01316 · Cited by 283
Self-citationElloumi‐Hannachi, I., Yamato, M., & Okano, T. (2010) · Journal of Internal Medicine · doi:10.1111/j.1365-2796.2009.02185.x · Cited by 271
Self-citationPrevascularization in tissue engineering: Current concepts and future directions
Laschke, M. W., & Menger, M. D. (2016) · Biotechnology Advances · doi:10.1016/j.biotechadv.2015.12.004 · Cited by 266
Induced Pluripotent Stem Cells 10 Years Later: For Cardiac Applications
Yoshida, Y., & Yamanaka, S. (2017) · Circulation Research · doi:10.1161/circresaha.117.311080 · Cited by 264
Wei, F., Qu, C., Song, T., Ding, G., Fan, Z., Liu, D., Liu, Y., Zhang, C., Shi, S., & Wang, S. (2012) · Journal of Cellular Physiology · doi:10.1002/jcp.24012 · Cited by 258
Temperature-responsive cell culture surfaces for regenerative medicine with cell sheet engineering
Yamato, M., Akiyama, Y., Kobayashi, J., Yang, J., Kikuchi, A., & Okano, T. (2007) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2007.06.002 · Cited by 254
Self-citationPre-vascularization of in vitro three-dimensional tissues created by cell sheet engineering
Asakawa, N., Shimizu, T., Tsuda, Y., Sekiya, S., Sasagawa, T., Yamato, M., Fukai, F., & Okano, T. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.01.105 · Cited by 245
Self-citationCell sheet engineering for heart tissue repair
Masuda, S., Shimizu, T., Yamato, M., & Okano, T. (2008) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2007.08.031 · Cited by 241
Self-citationMatsuura, K., Honda, A., Nagai, T., Fukushima, N., Iwanaga, K., Tokunaga, M., Shimizu, T., Okano, T., Kasanuki, H., Hagiwara, N., et al. (2009) · Journal of Clinical Investigation · doi:10.1172/jci37456 · Cited by 234
Self-citationPluripotent stem cell-derived cardiac tissue patch with advanced structure and function
Liau, B., Christoforou, N., Leong, K. W., & Bursac, N. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2011.08.050 · Cited by 233
“The presence of tissue pores and precise control of pore dimensions, combinedwith stackingofmultiplepatches [3,66], could allow extension of our approach to engineering a relatively thick cardiac tissue with enhanced capacity for vascularization and survival after implantation.”
BackgroundBiodegradable collagen patch with covalently immobilized VEGF for myocardial repair
Miyagi, Y., Chiu, L. L. Y., Cimini, M., Weisel, R. D., Radisic, M., & Li, R.-K. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2010.10.007 · Cited by 232
Mesoscopic hydrogel molding to control the 3D geometry of bioartificial muscle tissues
Bian, W., Liau, B., Badie, N., & Bursac, N. (2009) · Nature Protocols · doi:10.1038/nprot.2009.155 · Cited by 225
Engineering Cardiac Muscle Tissue: A Maturating Field of Research
Weinberger, F., Mannhardt, I., & Eschenhagen, T. (2017) · Circulation Research · doi:10.1161/circresaha.117.310738 · Cited by 225
Towards organ printing: engineering an intra-organ branched vascular tree
Visconti, R. P., Kasyanov, V., Gentile, C., Zhang, J., Markwald, R. R., & Mironov, V. (2010) · Expert Opinion on Biological Therapy · doi:10.1517/14712590903563352 · Cited by 224
“The obvious advantage of the second approach is that the vascularized tissue construct can be surgically dissected together with a large diameter vessel, making it suitable for surgical implantation [19,21].”
BackgroundCardiac Tissue Engineering in an In Vivo Vascularized Chamber
Morritt, A. N., Bortolotto, S. K., Dilley, R. J., Han, X., Kompa, A. R., McCombe, D., Wright, C. E., Itescu, S., Angus, J. A., & Morrison, W. A. (2007) · Circulation · doi:10.1161/circulationaha.106.657379 · Cited by 221
Cell delivery in regenerative medicine: The cell sheet engineering approach
Yang, J., Yamato, M., Nishida, K., Ohki, T., Kanzaki, M., Sekine, H., Shimizu, T., & Okano, T. (2006) · Journal of Controlled Release · doi:10.1016/j.jconrel.2006.06.022 · Cited by 215
Self-citationNon-thermal dielectric barrier discharge plasma induces angiogenesis through reactive oxygen species
Arjunan, K. P., Friedman, G., Fridman, A., & Clyne, A. M. (2012) · Journal of The Royal Society Interface · doi:10.1098/rsif.2011.0220 · Cited by 207
Kawamura, M., Miyagawa, S., Fukushima, S., Saito, A., Miki, K., Ito, E., Sougawa, N., Kawamura, T., Daimon, T., Shimizu, T., et al. (2013) · Circulation · doi:10.1161/circulationaha.112.000366 · Cited by 199
“after implantation, and cell-dense 1-mm thick cardiac tissue was developed by repeated transplantation of triple-layered rat neonatal cardiac cell sheets.(33) This cardiac graft gener-”
Self-citationBioengineering Heart Muscle: A Paradigm for Regenerative Medicine
Vunjak-Novakovic, G., Lui, K. O., Tandon, N., & Chien, K. R. (2011) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071910-124701 · Cited by 182
“This suggests additional strategies that involve the implantation of strands of cardiac muscle small enough to remain viable in nonperfused culture and avascular environments (34) or serial implantations of an increasing number of thin cell sheets (38) done to enhance vascularization.”
BackgroundCellular control of tissue architectures using a three-dimensional tissue fabrication technique
Tsuda, Y., Shimizu, T., Yamato, M., Kikuchi, A., Sasagawa, T., Sekiya, S., Kobayashi, J., Chen, G., & Okano, T. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.08.002 · Cited by 180
Self-citationCellular cardiomyoplasty and cardiac tissue engineering for myocardial therapy☆
Wang, F., & Guan, J. (2010) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2010.03.001 · Cited by 174
Heart muscle engineering: An update on cardiac muscle replacement therapy
ZIMMERMANN, W., DIDIE, M., DOKER, S., MELNYCHENKO, I., NAITO, H., ROGGE, C., TIBURCY, M., & ESCHENHAGEN, T. (2006) · Cardiovascular Research · doi:10.1016/j.cardiores.2006.03.023 · Cited by 169
“The presence of adherens junctions and gap junctions have been clearly demonstrated in engineered myocardium by several groups [19,20,73,84,85].”
BackgroundCurrent opportunities and challenges in skeletal muscle tissue engineering
Koning, M., Harmsen, M. C., van Luyn, M. J. A., & Werker, P. M. N. (2009) · Journal of Tissue Engineering and Regenerative Medicine · doi:10.1002/term.190 · Cited by 162
“By implanting the maximum of cell sheets over a vascular system, neovascularization occurs in vivo (Shimizu et al., 2006b).”
BackgroundDevelopment of a Biological Ventricular Assist Device: Preliminary Data From a Small Animal Model
Yildirim, Y., Naito, H., Didié, M., Karikkineth, B. C., Biermann, D., Eschenhagen, T., & Zimmermann, W.-H. (2007) · Circulation · doi:10.1161/circulationaha.106.679688 · Cited by 100
“Implantation studies demonstrate the applicability of pouch-like EHTs in vivo.”
BackgroundInfluentialEngineered cardiac organoid chambers: toward a functional biological model ventricle
Lee, E. J., Kim, D. E., Azeloglu, E. U., & Costa, K. D. (2008) · Tissue Engineering Part A · doi:10.1089/tea.2007.0351 · Cited by 84
Bioengineering approaches to treat the failing heart: from cell biology to 3D printing
Yadid, M., Oved, H., Silberman, E., & Dvir, T. (2022) · Nature Reviews Cardiology · doi:10.1038/s41569-021-00603-7 · Cited by 83
Metadata
- Authors
- Shimizu, T., Sekine, H., Yang, J., Isoi, Y., Yamato, M., Kikuchi, A., Kobayashi, E., & Okano, T.
- Venue
- The FASEB Journal
- Publisher
- Wiley
- Published
- 2006-01-26
- Volume
- 20
- Issue
- 6
- Pages
- 708-710
- ISSN
- 0892-6638 (ISSN-L)
- 1530-6860
- OpenAlex
- W2144856878
- Cited by
- 478
- References
- 30
- FWCI
- 23.07
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.