Magnetic Resonance Imaging at 3.0 Tesla: Challenges and Advantages in Clinical Neurological Imaging
The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Abstract
MR imaging at very high field (3.0 T) is a significant new clinical tool in the modern neuroradiological armamentarium. In this report, we summarize our 40-month experience in performing clinical neuroradiological examinations at 3.0 T and review the relevant technical issues. We report on these issues and, where appropriate, their solutions. Issues examined include: increased SNR, larger chemical shifts, additional problems associated with installation of these scanners, challenges in designing and obtaining appropriate clinical imaging coils, greater acoustic noise, increased power deposition, changes in relaxation rates and susceptibility effects, and issues surrounding the safety and compatibility of implanted devices. Some of the these technical factors are advantageous (eg, increased signal-to-noise ratio), some are detrimental (eg, installation, coil design and development, acoustic noise, power deposition, device compatibility, and safety), and a few have both benefits and disadvantages (eg, changes in relaxation, chemical shift, and susceptibility). Fortunately solutions have been developed or are currently under development, by us and by others, for nearly all of these challenges. A short series of 1.5 T and 3.0 T patient images are also presented to illustrate the potential diagnostic benefits of scanning at higher field strengths. In summary, by paying appropriate attention to the discussed technical issues, high-quality neuro-imaging of patients is possible at 3.0 T.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ogawa, S., Tank, D. W., Menon, R., Ellermann, J. M., Kim, S. G., Merkle, H., & Ugurbil, K. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.13.5951 · Cited by 3,681 · cited 1×
“oxygen level dependent (BOLD) effect that is the basis of functional MR imaging (fMRI).(4) Both of these properties at”
BackgroundSimultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays
Sodickson, D. K., & Manning, W. J. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380414 · Cited by 2,142
Multi-planar image formation using NMR spin echoes
Mansfield, P. (1977) · Journal of Physics C: Solid State Physics · doi:10.1088/0022-3719/10/3/004 · Cited by 1,813 · cited 1×
“Single-shot EPI (ie, collecting a full image per excitation) can collect an image in 100 milliseconds or less and effectively “freezes” motion effects.(51) Although in many EPI applications increased susceptibility is used to an advantage, the trade-off is that we are inherently sensitizing the acquisition to B0 inhom…”
BackgroundBottomley, P. A., Foster, T. H., Argersinger, R. E., & Pfeifer, L. M. (1984) · Medical Physics · doi:10.1118/1.595535 · Cited by 1,192
An efficient, highly homogeneous radiofrequency coil for whole-body NMR imaging at 1.5 T
Hayes, C. E., Edelstein, W. A., Schenck, J. F., Mueller, O. M., & Eash, M. G. (1985) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(85)90257-4 · Cited by 912 · cited 1×
“0 T scanner, the principal neuro-imaging coil is a birdcage volume coil.(22) The sources of RF inhomogeneities for this type of coil have been shown to depend on the dielectric properties of the sample, which affects the RF field distribution in the transverse plane, and on the coil geometry, which more greatly affect…”
Background7T vs. 4T: RF power, homogeneity, and signal-to-noise comparison in head images
Vaughan, J. T., Garwood, M., Collins, C. M., Liu, W., DelaBarre, L., Adriany, G., Andersen, P., Merkle, H., Goebel, R., Smith, M. B., et al. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1156 · Cited by 890 · cited 1×
“This inhomogeneity has been demonstrated as a potential source of image artifacts in very high field systems.(3,20,21) On our 3.”
BackgroundIntravascular susceptibility contrast mechanisms in tissues
Kennan, R. P., Zhong, J., & Gore, J. C. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910310103 · Cited by 524 · cited 1×
“Spin-echo (SE) techniques are able to refocus much of this dephasing.(47) The relaxation rate R2* attempts to estimate the susceptibility-induced signal loss.”
BackgroundExperimental determination of the BOLD field strength dependence in vessels and tissue
Gati, J. S., Menon, R. S., Uǧurbil, K., & Rutt, B. K. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380220 · Cited by 523 · cited 2×
“BOLD fMRI contrast is also optimized when the imaging echo time is set near the T2* of gray matter.(50,57,58) As field strength increases, T2* shortens ( 66 milliseconds at 1.”
MethodMenon, R. S., Ogawa, S., Hu, X., Strupp, J. P., Anderson, P., & Uǧurbil, K. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910330323 · Cited by 421 · cited 1×
“smaller vessels rather than in and around larger draining veins.(55,56) One study directly found that 3.”
BackgroundBandettini, P. A., Wong, E. C., Jesmanowicz, A., Hinks, R. S., & Hyde, J. S. (1994) · NMR in Biomedicine · doi:10.1002/nbm.1940070104 · Cited by 349 · cited 2×
“BOLD fMRI contrast is also optimized when the imaging echo time is set near the T2* of gray matter.(50,57,58) As field strength increases, T2* shortens ( 66 milliseconds at 1.”
MethodNeuroimaging at 1.5 T and 3.0 T: Comparison of oxygenation‐sensitive magnetic resonance imaging
Krüger, G., Kastrup, A., & Glover, G. H. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1081 · Cited by 325 · cited 2×
“BOLD fMRI contrast is also optimized when the imaging echo time is set near the T2* of gray matter.(50,57,58) As field strength increases, T2* shortens ( 66 milliseconds at 1.”
MethodDiffusion-weighted spin-echo fMRI at 9.4 T: Microvascular/tissue contribution to BOLD signal changes
Lee, S.-P., Silva, A. C., Ugurbil, K., & Kim, S.-G. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<919::aid-mrm12>3.0.co;2-8 · Cited by 288 · cited 2×
“Nonetheless, as field strength increases the BOLD effect becomes dominated by small vessels, making SE EPI the more probable technique of choice.(56,59) However, more RF power is then required and RF power deposition is a concern at high magnetic field (see previous discussion).”
BackgroundTannús, A., & Garwood, M. (1997) · NMR in Biomedicine · doi:10.1002/(sici)1099-1492(199712)10:8<423::aid-nbm488>3.0.co;2-x · Cited by 270
Comparison of linear and circular polarization for magnetic resonance imaging
Glover, G. H., Hayes, C. E., Pelc, N. J., Edelstein, W. A., Mueller, O. M., Hart, H. R., Hardy, C. J., O'Donnell, M., & Barber, W. D. (1985) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(85)90349-x · Cited by 265 · cited 1×
“This inhomogeneity has been demonstrated as a potential source of image artifacts in very high field systems.(3,20,21) On our 3.”
BackgroundPfeuffer, J., Van de Moortele, P., Ugurbil, K., Hu, X., & Glover, G. H. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10065 · Cited by 216 · cited 1×
“This technique and others like it are becoming standard implementations in fMRI research laboratories.(61,62) The”
MethodSingle‐voxel proton MRS of the human brain at 1.5T and 3.0T
Barker, P. B., Hearshen, D. O., & Boska, M. D. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1104 · Cited by 208
Bernstein, M. A., Huston, J., Lin, C., Gibbs, G. F., & Felmlee, J. P. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1282 · Cited by 206 · cited 2×
“In time-of-flight (TOF) MRA, the decreased R1 of the background tissues and the near constant R1 for blood lead to an overall improvement in the bloodto-background contrast.(8,10,29,39,45,46) This occurs in TOF MRA because of the short repetition time (TR) that preferFIGURE 8.”
BackgroundHigh-Resolution MR Venography at 3.0 Tesla
Reichenbach, J. R., Barth, M., Haacke, E. M., Klarhöfer, M., Kaiser, W. A., & Moser, E. (2000) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-200011000-00023 · Cited by 199
Acoustic noise during functional magnetic resonance imaging
Ravicz, M. E., Melcher, J. R., & Kiang, N. Y.-S. (2000) · The Journal of the Acoustical Society of America · doi:10.1121/1.1310190 · Cited by 177 · cited 1×
“These other factors are wide ranging and run from the use of specialized compounds to resist gradient motion, through to the use of acoustic-deadening tiles in the scanner room.(31) Nevertheless, theoretically, Lorentz’s Law predicts larger forces on gradients per unit gradient current and thus the gradients become in…”
BackgroundHuman cardiac imaging at 3 T using phased array coils
Noeske, R., Seifert, F. C., Rhein, K. H., & Rinneberg, H. H. (2000) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200012)44:6<978::aid-mrm22>3.0.co;2-9 · Cited by 167 · cited 3×
“0 T.(29,44) This corresponds to an increase in T1 relaxation time of between 25% and 40%.”
BackgroundA transmit-only/receive-only (TORO) RF system for high-field MRI/MRS applications
Barberi, E. A., Gati, J. S., Rutt, B. K., & Menon, R. S. (2000) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(200002)43:2<284::aid-mrm16>3.0.co;2-c · Cited by 157
Diffusion-Tensor MR Imaging at 1.5 and 3.0 T: Initial Observations
Hunsche, S., Moseley, M. E., Stoeter, P., & Hedehus, M. (2001) · Radiology · doi:10.1148/radiol.2212001823 · Cited by 152
Alecci, M., Collins, C. M., Smith, M. B. H., & Jezzard, P. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1201 · Cited by 144 · cited 2×
“In fact, for 1 coil geometry it was found that axial RF homogeneity within 10% was contained only within 33% of the coil’s length.(23) Hence, careful positioning of the patient head within the coil becomes very important.”
BackgroundAl-Kwifi, O. S., Emery, D. J., & Wilman, A. H. (2002) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(02)00486-1 · Cited by 131 · cited 1×
“In time-of-flight (TOF) MRA, the decreased R1 of the background tissues and the near constant R1 for blood lead to an overall improvement in the bloodto-background contrast.(8,10,29,39,45,46) This occurs in TOF MRA because of the short repetition time (TR) that preferFIGURE 8.”
BackgroundDetunable transverse electromagnetic (TEM) volume coil for high‐field NMR
Vaughan, J. T., Adriany, G., Garwood, M., Yacoub, E., Duong, T., DelaBarre, L., Andersen, P., & Ugurbil, K. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10141 · Cited by 128
Computation of electromagnetic fields for high-frequency magnetic resonance imaging applications
Jin, J., Chen, J., Chew, W. C., Gan, H., Magin, R. L., & Dimbylow, P. J. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/12/011 · Cited by 119 · cited 1×
“This may result in the formation of standing wave patterns that degrade the homogeneity of the RF field.(18,19) This inhomogeneity has been demonstrated as a potential source of image artifacts in very high field systems.”
BackgroundRueckert, L., Appollonio, I., Grafman, J., Jezzard, P., Johnson, R., Le Bihan, D., & Turner, R. (1994) · Journal of Neuroimaging · doi:10.1111/jon19944267 · Cited by 115
Spectroscopy and imaging with a 4 tesla whole‐body mr system
Bomsdorf, H., Helzel, T., Kunz, D., Röschmann, P., Tschendel, O., & Wieland, J. (1988) · NMR in Biomedicine · doi:10.1002/nbm.1940010308 · Cited by 110 · cited 2×
“This inhomogeneity has been demonstrated as a potential source of image artifacts in very high field systems.(3,20,21) On our 3.”
BackgroundMR Safety and the American College of Radiology White Paper
Shellock, F. G., & Crues, J. V. (2002) · American Journal of Roentgenology · doi:10.2214/ajr.178.6.1781349 · Cited by 90
Determinants of Proton Relaxation Rates in Tissue
Koenig, S. H., & Brown, R. D. (1984) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910010404 · Cited by 88
Whole-body MR imaging and spectroscopy with a 4-T system.
Barfuss, H., Fischer, H., Hentschel, D., Ladebeck, R., & Vetter, J. (1988) · Radiology · doi:10.1148/radiology.169.3.3187004 · Cited by 83
Kim, S., Hu, X., Adriany, G., & Uǧurbil, K. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910350618 · Cited by 82
Comparison of diffusion‐weighted high‐resolution CBF and spin‐echo BOLD fMRI at 9.4 T
Lee, S., Silva, A. C., & Kim, S. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10117 · Cited by 65 · cited 1×
“Nonetheless, as field strength increases the BOLD effect becomes dominated by small vessels, making SE EPI the more probable technique of choice.(56,59) However, more RF power is then required and RF power deposition is a concern at high magnetic field (see previous discussion).”
BackgroundAn analytical model for the design of RF resonators for MR body imaging
Foo, T., Hayes, C. E., & Kang, Y. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910210202 · Cited by 65 · cited 1×
“This may result in the formation of standing wave patterns that degrade the homogeneity of the RF field.(18,19) This inhomogeneity has been demonstrated as a potential source of image artifacts in very high field systems.”
BackgroundPerfusion and diffusion MR imaging of thromboembolic stroke
de Crespigny, A. J., TSUURA, M., Moseley, M. E., & Kucharczyk, J. R. (1993) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880030510 · Cited by 61
Investigation of BOLD contrast in fMRI using multi-shot EPI
Menon, R. S., Thomas, C. G., & Gati, J. S. (1997) · NMR in Biomedicine · doi:10.1002/(sici)1099-1492(199706/08)10:4/5<179::aid-nbm463>3.0.co;2-x · Cited by 53
1H spectroscopic imaging using a spectral‐spatial excitation pulse
Spielman, D. M., Meyer, C. H., Macovski, A., & Enzmann, D. R. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910180203 · Cited by 51 · cited 1×
“This includes the use of spectralspatial excitations that excite only water (or fat) within the excited slab.(16) Figure 4 shows examples of images obtained using an improperly and a properly adjusted spectral-spatial fat suppression pulse at 3.”
BackgroundWansapura (1999) · doi:10.1002/(sici)1522-2586(199904)9:4
Cited by
Barber, P. A. (2005) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.2004.059261 · Cited by 363
Routine clinical brain MRI sequences for use at 3.0 Tesla
Lu, H., Nagae‐Poetscher, L. M., Golay, X., Lin, D., Pomper, M., & van Zijl, P. C. M. (2005) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20356 · Cited by 327
Whole-body MRI at high field: technical limits and clinical potential
Schick, F. (2005) · European Radiology · doi:10.1007/s00330-005-2678-0 · Cited by 314
Triaging transient ischemic attack and minor stroke patients using acute magnetic resonance imaging
Coutts, S. B., Simon, J. E., Eliasziw, M., Sohn, C., Hill, M. D., Barber, P. A., Palumbo, V., Kennedy, J., Roy, J., Gagnon, A., et al. (2005) · Annals of Neurology · doi:10.1002/ana.20497 · Cited by 232
“This may enhance detection of ischemia using DWI sequences by an improved signal-to-noise ratio.(40) Similar improvements in DWI lesion detection can be achieved with more commonly available 1.”
BackgroundQualitative Comparison of 3-T and 1.5-T MRI in the Evaluation of Epilepsy
Phal, P. M., Usmanov, A., Nesbit, G. M., Anderson, J. C., Spencer, D., Wang, P., Helwig, J. A., Roberts, C., & Hamilton, B. E. (2008) · American Journal of Roentgenology · doi:10.2214/ajr.07.3933 · Cited by 160
Metadata
- Authors
- Frayne, R., Goodyear, B. G., Dickhoff, P., Lauzon, M. L., & Sevick, R. J.
- Venue
- Investigative Radiology
- Published
- 2003-07
- Volume
- 38
- Issue
- 7
- Pages
- 385-402
- ISSN
- 0020-9996 (ISSN-L)
- OpenAlex
- W2322779325
- Cited by
- 212
- References
- 38
- FWCI
- 18.88
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.