Noninvasive Continuous Monitoring of Tear Glucose Using Glucose-Sensing Contact Lenses
The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
: The incidence of diabetes mellitus is dramatically increasing in the developed countries. Tight control of blood glucose concentration is crucial to diabetic patients to prevent microvascular complications. Self-monitoring of blood glucose is widely used for controlling blood glucose levels and usually performed by an invasive test using a portable glucometer. Many technologies have been developed over the past decades with the purpose of obtaining a continuous physiological glycemic monitoring. A contact lens is the ideal vehicle for continuous tear glucose monitoring of glucose concentration in tear film. There are several research groups that are working in the development of contact lenses with embedded biosensors for continuously and noninvasively monitoring tear glucose levels. Although numerous aspects must be improved, contact lens technology is one step closer to helping diabetic subjects better manage their condition, and these contact lenses will be able to measure the level of glucose in the wearer's tears and communicate the information to a mobile phone or computer. This article reviews studies on ocular glucose and its monitoring methods as well as the attempts to continuously monitor the concentration of tear glucose by using contact lens-based sensors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Global estimates of diabetes prevalence for 2013 and projections for 2035
Guariguata, L., Whiting, D. R., Hambleton, I., Beagley, J., Linnenkamp, U., & Shaw, J. E. (2014) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2013.11.002 · Cited by 4,642 · cited 1×
“Most people with diabetes live in low- and middle-income countries and these will experience the greatest increase in cases of diabetes over the next 22 years.(1) Early diagnosis and tight control of blood glucose concentration are crucial to patients to prevent microvascular complications such as atherosclerosis, cor…”
BackgroundELECTRODE SYSTEMS FOR CONTINUOUS MONITORING IN CARDIOVASCULAR SURGERY
Clark, L. C., & Lyons, C. (1962) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1962.tb13623.x · Cited by 3,945
Glucose sensors: a review of current and emerging technology
Oliver, N. S., Toumazou, C., Cass, A. E. G., & Johnston, D. G. (2009) · Diabetic Medicine · doi:10.1111/j.1464-5491.2008.02642.x · Cited by 584 · cited 3×
“Thus, with the purpose of obtaining a continuous physiological glycemic control, several implantable biosensors used in subcutaneous tissue and vessels have been developed for in situ monitoring of blood glucose.(4,7,8) A blood glucose meter only provides a brief ‘‘snapshot’’ of glucose level at a single moment in tim…”
BackgroundA contact lens with embedded sensor for monitoring tear glucose level
Yao, H., Shum, A. J., Cowan, M., Lähdesmäki, I., & Parviz, B. A. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.12.042 · Cited by 513 · cited 8×
“Reproduced with permission from Yao et al.(24) 428 Monitoring of Tear Glucose with Glucose-Sensing Contact LensesVAscaso and Huerva”
BackgroundMethodInfluentialA 3-$\mu\hbox{W}$ CMOS Glucose Sensor for Wireless Contact-Lens Tear Glucose Monitoring
Liao, Y.-T., Yao, H., Lingley, A., Parviz, B., & Otis, B. P. (2012) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2011.2170633 · Cited by 372
Photonic Crystal Glucose-Sensing Material for Noninvasive Monitoring of Glucose in Tear Fluid
Alexeev, V. L., Das, S., Finegold, D. N., & Asher, S. A. (2004) · Clinical Chemistry · doi:10.1373/clinchem.2004.039701 · Cited by 370 · cited 3×
“Alexeev et al.(32) developed another similar system based on embedding photonic crystals in a hydrogel patch, creating a holographic hydrogel.”
BackgroundMethodFast Responsive Crystalline Colloidal Array Photonic Crystal Glucose Sensors
Ben-Moshe, M., Alexeev, V. L., & Asher, S. A. (2006) · Analytical Chemistry · doi:10.1021/ac060643i · Cited by 292
Chu, M. X., Miyajima, K., Takahashi, D., Arakawa, T., Sano, K., Sawada, S.-I., Kudo, H., Iwasaki, Y., Akiyoshi, K., Mochizuki, M., et al. (2011) · Talanta · doi:10.1016/j.talanta.2010.10.055 · Cited by 279 · cited 7×
“The development of contact lenses with embedded sensors includes two general methods in the determination technique: spectral determination, using fluorescence-based techniques(24) or glucose-sensitive hydrogels embedded with photonic crystals,(34,35) and electrochemical determination.(9)”
BackgroundMethodInfluentialTear glucose levels in normal people and in diabetic patients.
Sen, D. K., & Sarin, G. S. (1980) · British Journal of Ophthalmology · doi:10.1136/bjo.64.9.693 · Cited by 203 · cited 1×
“In fact, it has been demonstrated that blood glucose is about two times higher in diabetic patients than in nondiabetic patients, whereas tear glucose is about five times higher in diabetic patients than in nondiabetic patients.(25) However, although several authors have reported a good correlation between tear glucos…”
BackgroundTear glucose analysis for the noninvasive detection and monitoring of diabetes mellitus
Baca, J. T., Finegold, D. N., & Asher, S. A. (2007) · The Ocular Surface · doi:10.1016/s1542-0124(12)70094-0 · Cited by 187 · cited 2×
“However, although several authors have reported a good correlation between tear glucose and blood glucose, others talk about the glucose levels in tears being below detection.(22,26) These discrepancies are probably attributed to the different tear collection methods, for example, filter paper or microcapillary.”
Background
Cited by
Wearable smart sensor systems integrated on soft contact lenses for wireless ocular diagnostics
Kim, J., Kim, M., Lee, M.-S., Kim, K., Ji, S., Kim, Y.-T., Park, J., Na, K., Bae, K.-H., Kyun Kim, H., et al. (2017) · Nature Communications · doi:10.1038/ncomms14997 · Cited by 951
Type 2 diabetes mellitus in adults: pathogenesis, prevention and therapy
Lu, X., Xie, Q., Pan, X., Zhang, R., Zhang, X., Peng, G., Zhang, Y., Shen, S., & Tong, N. (2024) · Signal Transduction and Targeted Therapy · doi:10.1038/s41392-024-01951-9 · Cited by 665
Sang, M., Shin, J., Kim, K., & Yu, K. J. (2019) · Nanomaterials · doi:10.3390/nano9030374 · Cited by 505
Sacks, D. B., Arnold, M., Bakris, G. L., Bruns, D. E., Horvath, A. R., Lernmark, Å., Metzger, B. E., Nathan, D. M., & Kirkman, M. S. (2023) · Diabetes Care · doi:10.2337/dci23-0036 · Cited by 351
Point-of-care testing based on smartphone: The current state-of-the-art (2017–2018)
Liu, J., Geng, Z., Fan, Z., Liu, J., & Chen, H. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2019.01.068 · Cited by 335
Metadata
- Authors
- Ascaso, F. J., & Huerva, V.
- Venue
- Optometry and Vision Science
- Publisher
- Wiley
- Published
- 2016-04
- Volume
- 93
- Issue
- 4
- Pages
- 426-434
- ISSN
- 1040-5488 (ISSN-L)
- OpenAlex
- W2291208257
- Cited by
- 67
- References
- 14
- FWCI
- 7.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Noninvasive Continuous Monitoring of Tear Glucose Using Glucose-Sensing Contact Lenses. https://app.cochat.ai/papers/10.1097/opx.0000000000000698
- The paper
- Ascaso, F. J., & Huerva, V. (2016). Noninvasive Continuous Monitoring of Tear Glucose Using Glucose-Sensing Contact Lenses. Optometry and Vision Science. https://doi.org/10.1097/opx.0000000000000698
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.