CoChat

Modeling study of peripheral nerve recording selectivity

Perez-Perive, J., Durund, D.M. · 2000 · IEEE Transactions on Rehabilitation Engineering
Cited by 55

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Recording of sensory information from afferent fibers can be used as feedback for the closed-loop control of neural prostheses. Clinical applications suggest that recording selectively from various nerve fascicles is important. Current nerve cuff electrodes are generally circular in shape and use a tripolar recording configuration. Preliminary experiments suggest that slowly changing the shape of the nerve to a flatter cross section can improve its selectivity. The objective of this work is to determine the effects of nerve reshaping and other cuff design parameters on the fascicular recording selectivity of a nerve cuff. A finite-element computer model of a multifasciculated nerve with different cuff electrodes was implemented to simulate the recordings. The model included the inhomogeneous and anisotropic properties of peripheral nerves. The recording selectivity was quantified with the use of a Selectivity Index. The results from the model provided information regarding the effect of using monopolar versus tripolar recording configurations, the length of the tripoles in tripolar recordings, the number of contacts that maximize the selectivity index, and the cuff length. Nerve reshaping was found to cause important recording selectivity improvements (106% average). These results provide specific criteria for the design of selectively recording nerve cuff electrodes.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/86.867874

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 31

  1. sweeney, 1987, modeling of mammalian myelinated nerve for functional neuromuscular stimulation, Proc 9th IEEE/EMBS Annu Int Conf
  2. 10.1093/brain/71.3.242 · DOI · Paper page
  3. tyler, 1999, chronic effect of a flat interface nerve electrode, Proc NIH Neural Prostheses Workshop
  4. tasaki, 1964, a new measurement of action currents developed by single nodes of ranvier, J Neurophysiol, 27, 1199, 10.1152/jn.1964.27.6.1199 · DOI
  5. 10.1109/86.296346 · DOI · Paper page
  6. 10.1109/86.769412 · DOI · Paper page
  7. hoffer, 1998, Nerve cuff having one or more isolated chambers
  8. 10.1016/0165-0270(81)90033-9 · DOI
  9. hoffer, 1996, neural signals for command control and feedback in functional neuromuscular stimulation: a review, J Rehab Res Develop, 33, 145
  10. hoffer, 1997, multi-channel recordings from peripheral nerves: 1. properties of multi-contact cuff (mcc) and longitudinal intra-fascicular electrode (life) arrays implanted in cat forelimb nerves, Proc IFESS/NP, 239
  11. hsu, 1996, determination of excitation thresholds of nerve fibers during magnetic stimulation, Proc 18th IEEE/EMBS Annu Int Conf
  12. 10.1109/TBME.1979.326507 · DOI · Paper page
  13. 10.1016/S0006-3495(76)85719-0 · DOI
  14. 10.1002/aja.1000060108 · DOI
  15. 10.1016/S0006-3495(97)78890-8 · DOI · Paper page
  16. stein, 1992, Neural Prostheses Replacing Motor Function After Disease or Disability
  17. 10.1016/0141-5425(88)90099-4 · DOI
  18. chen, 1997, multi-channel recordings from peripheral nerves: 2. measurement of selectivity, Proc IFESS/NP, 241
  19. struijk, 1996, fascicle selective recording with a nerve cuff electrode, Proc 18th IEEE/EMBS Annu Int Conf
  20. cavanaugh, 1996, finite element analysis of electrical nerve stimulation, Proc 18th IEEE/EMBS Annu Int Conf
  21. christensen, 1997, multi-channel recordings from peripheral nerves: 4. evaluation of selectivity using mechanical stimulation of individual digits, Proc IFESS/NP, 217
  22. 10.1109/10.4579 · DOI
  23. 10.1109/IEMBS.1997.758734 · DOI
  24. clark, 1968, the extracellular potential field of the single active nerve fiber in a volume conductor, Biophys J, 8, 842, 10.1016/S0006-3495(68)86524-5 · DOI · Paper page
  25. agnew, 1990, Neural Prostheses Fundamental Studies
  26. 10.1109/10.709558 · DOI · Paper page
  27. 10.1109/IEMBS.1995.579536 · DOI
  28. sahin, 1996, selective recording with a multi-contact nerve cuff electrode, Proc 18th IEEE/EMBS Annu Int Conf
  29. stein, 1975, principles underlying new methods for chronic neural recording, Can J Neurologic Sci, 234
  30. sinkjaer, 1992, sensors, Restoration of Walking for Paraplegics Recent Advancements and Trends, 251
  31. 10.1016/0022-5193(71)90155-X · DOI

Cited by

See all 55

Metadata

Authors
Perez-Perive, J., & Durund, D. M.
Venue
IEEE Transactions on Rehabilitation Engineering
Published
2000
Volume
8
Issue
3
Pages
320-329
ISSN
1063-6528 (ISSN-L)
OpenAlex
W2038069973
Cited by
55
References
4
FWCI
0.12
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.