Modeling study of peripheral nerve recording selectivity
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Recording of sensory information from afferent fibers can be used as feedback for the closed-loop control of neural prostheses. Clinical applications suggest that recording selectively from various nerve fascicles is important. Current nerve cuff electrodes are generally circular in shape and use a tripolar recording configuration. Preliminary experiments suggest that slowly changing the shape of the nerve to a flatter cross section can improve its selectivity. The objective of this work is to determine the effects of nerve reshaping and other cuff design parameters on the fascicular recording selectivity of a nerve cuff. A finite-element computer model of a multifasciculated nerve with different cuff electrodes was implemented to simulate the recordings. The model included the inhomogeneous and anisotropic properties of peripheral nerves. The recording selectivity was quantified with the use of a Selectivity Index. The results from the model provided information regarding the effect of using monopolar versus tripolar recording configurations, the length of the tripoles in tripolar recordings, the number of contacts that maximize the selectivity index, and the cuff length. Nerve reshaping was found to cause important recording selectivity improvements (106% average). These results provide specific criteria for the design of selectively recording nerve cuff electrodes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
THE INTRANEURAL TOPOGRAPHY OF THE RADIAL, MEDIAN AND ULNAR NERVES
SUNDERLAND, S. (1945) · Brain · doi:10.1093/brain/68.4.243 · Cited by 426 · cited 1×
“ings of the sensory signals contained in afferent fibers can provide information about variables such as pressure, joint angle, muscle force, or length [11]–[13], [16], [31].”
BackgroundCutaneous whole nerve recordings used for correction of footdrop in hemiplegic man
Haugland, M. K., & Sinkjaer, T. (1995) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.481970 · Cited by 168
Stable long-term recordings from cat peripheral nerves
Stein, R. B., Nichols, T. R., Jhamandas, J., Davis, L., & Charles, D. (1977) · Brain Research · doi:10.1016/0006-8993(77)90233-5 · Cited by 160 · cited 1×
“ilar relationships between tripole length and recorded amplitude have been reported elsewhere [14], [22], [25].”
BackgroundCuff electrodes for long-term recording of natural sensory information
Struijk, J. J., Thomsen, M., Larsen, J. O., & Sinkjaer, T. (1999) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.765194 · Cited by 97 · cited 1×
“Several attempts have been made to achieve fascicular recording selectivity with cylindrical nerve cuff electrodes [8], [14], [22], [30], [19] and achieved good selectivity.”
Background
Research works printed but not linked: 31
- sweeney, 1987, modeling of mammalian myelinated nerve for functional neuromuscular stimulation, Proc 9th IEEE/EMBS Annu Int Conf
- 10.1093/brain/71.3.242 · DOI · Paper page
- tyler, 1999, chronic effect of a flat interface nerve electrode, Proc NIH Neural Prostheses Workshop
- tasaki, 1964, a new measurement of action currents developed by single nodes of ranvier, J Neurophysiol, 27, 1199, 10.1152/jn.1964.27.6.1199 · DOI
- 10.1109/86.296346 · DOI · Paper page
- 10.1109/86.769412 · DOI · Paper page
- hoffer, 1998, Nerve cuff having one or more isolated chambers
- 10.1016/0165-0270(81)90033-9 · DOI
- hoffer, 1996, neural signals for command control and feedback in functional neuromuscular stimulation: a review, J Rehab Res Develop, 33, 145
- hoffer, 1997, multi-channel recordings from peripheral nerves: 1. properties of multi-contact cuff (mcc) and longitudinal intra-fascicular electrode (life) arrays implanted in cat forelimb nerves, Proc IFESS/NP, 239
- hsu, 1996, determination of excitation thresholds of nerve fibers during magnetic stimulation, Proc 18th IEEE/EMBS Annu Int Conf
- 10.1109/TBME.1979.326507 · DOI · Paper page
- 10.1016/S0006-3495(76)85719-0 · DOI
- 10.1002/aja.1000060108 · DOI
- 10.1016/S0006-3495(97)78890-8 · DOI · Paper page
- stein, 1992, Neural Prostheses Replacing Motor Function After Disease or Disability
- 10.1016/0141-5425(88)90099-4 · DOI
- chen, 1997, multi-channel recordings from peripheral nerves: 2. measurement of selectivity, Proc IFESS/NP, 241
- struijk, 1996, fascicle selective recording with a nerve cuff electrode, Proc 18th IEEE/EMBS Annu Int Conf
- cavanaugh, 1996, finite element analysis of electrical nerve stimulation, Proc 18th IEEE/EMBS Annu Int Conf
- christensen, 1997, multi-channel recordings from peripheral nerves: 4. evaluation of selectivity using mechanical stimulation of individual digits, Proc IFESS/NP, 217
- 10.1109/10.4579 · DOI
- 10.1109/IEMBS.1997.758734 · DOI
- clark, 1968, the extracellular potential field of the single active nerve fiber in a volume conductor, Biophys J, 8, 842, 10.1016/S0006-3495(68)86524-5 · DOI · Paper page
- agnew, 1990, Neural Prostheses Fundamental Studies
- 10.1109/10.709558 · DOI · Paper page
- 10.1109/IEMBS.1995.579536 · DOI
- sahin, 1996, selective recording with a multi-contact nerve cuff electrode, Proc 18th IEEE/EMBS Annu Int Conf
- stein, 1975, principles underlying new methods for chronic neural recording, Can J Neurologic Sci, 234
- sinkjaer, 1992, sensors, Restoration of Walking for Paraplegics Recent Advancements and Trends, 251
- 10.1016/0022-5193(71)90155-X · DOI
Cited by
Navarro, X., Krueger, T. B., Lago, N., Micera, S., Stieglitz, T., & Dario, P. (2005) · Journal of the Peripheral Nervous System · doi:10.1111/j.1085-9489.2005.10303.x · Cited by 845
Implanted Neural Interfaces: Biochallenges and Engineered Solutions
Grill, W. M., Norman, S. E., & Bellamkonda, R. V. (2009) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-061008-124927 · Cited by 488
“However, there are emerging methods of using individual electrodes within a multielectrode cuff to achieve spatially selective recording from individual fascicles within compound peripheral nerve trunks (46, 47).”
MethodFascicular perineurium thickness, size, and position affect model predictions of neural excitation
Grinberg, Y., Schiefer, M. A., Tyler, D. J., & Gustafson, K. J. (2008) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.2010348 · Cited by 145
“In these studies, the was fixed to 800 m [2], [12] or 617 m [19].”
InfluentialYoo, P. B., & Durand, D. M. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.851482 · Cited by 106
“While previous work has shown that maximum overall selectivity is achieved when the number of contacts equals that of the nerve fascicles [26], this generally occurs when the distribution of the contacts are optimally placed with respect to each bundle of fibers.”
InfluentialSchiefer, M. A., Tyler, D. J., & Triolo, R. J. (2012) · Journal of Computational Neuroscience · doi:10.1007/s10827-011-0381-5 · Cited by 53
Metadata
- Authors
- Perez-Perive, J., & Durund, D. M.
- Venue
- IEEE Transactions on Rehabilitation Engineering
- Published
- 2000
- Volume
- 8
- Issue
- 3
- Pages
- 320-329
- ISSN
- 1063-6528 (ISSN-L)
- OpenAlex
- W2038069973
- Cited by
- 55
- References
- 4
- FWCI
- 0.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.