CoChat

Control of FES thumb force using slip information obtained from the cutaneous electroneurogram in quadriplegic man

Haugland, M., Lickel, A., Haase, J., Sinkjaer, T. · 1999 · IEEE Transactions on Rehabilitation Engineering
Cited by 112

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

A tetraplegic volunteer was implanted with percutaneous intramuscular electrodes in hand and forearm muscles. Furthermore, a sensory nerve cuff electrode was implanted on the volar digital nerve to the radial side of the index finger branching off the median nerve. In laboratory experiments a stimulation system was used to produce a lateral grasp (key grip) while the neural activity was recorded with the cuff electrode. The nerve signal contained information that could be used to detect the occurrence of slips and further to increase stimulation intensity to the thumb flexor/adductor muscles to stop the slip. Thereby the system provided a grasp that could catch an object if it started to slip due to, e.g., decreasing muscle force or changes in load forces tangential to the surface of the object. This method enabled an automatic adjustment of the stimulation intensity to the lowest possible level without loosing the grip and without any prior knowledge about the strength of the muscles and the weight and surface texture of the object.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/86.769412

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Research works printed but not linked: 39

  1. 10.1109/10.293216 · DOI · Paper page
  2. 10.1109/10.32102 · DOI · Paper page
  3. 10.1109/10.481986 · DOI · Paper page
  4. 10.1007/978-3-642-80211-9_40 · doi:10.1007/978-3-642-80211-9_40
  5. 10.1007/978-1-4612-2104-3_46 · DOI
  6. slot, 1997, effect of chronically implanted nerve cuff electrodes on the electrophysiological properties of human sensory nerves, Artificial Organs, 21
  7. lickel, 1998, Restoration of lateral hand grasp in a tetraplegic patient applying natural sensory feedback, 1
  8. riso, 1995, characterization of cutaneous nerve responses for control of neuromotor prostheses, Proc 5th Vienna Int Workshop Functional Electrostimulation, 335
  9. 10.1007/BF02476115 · DOI
  10. howe, 1992, touch sensing for robotic manipulation and recognition, Robotics Review 2, 55
  11. 10.1007/BF00237997 · DOI · Paper page
  12. stein, 1992, optimal stimulation of paralyzed muscle after human spinal cord injury, Amer Physiologic Soc, 1393
  13. 10.1016/0014-4886(68)90041-1 · DOI · Paper page
  14. 10.1113/jphysiol.1973.sp010279 · DOI · Paper page
  15. 10.1113/jphysiol.1975.sp010835 · DOI · Paper page
  16. 10.1113/jphysiol.1979.sp012809 · DOI · Paper page
  17. vallbo, 1984, properties of cutaneous mechanoreceptors in the human hand related to touch sensation, Human Neurobiol, 3, 3
  18. 10.1007/BF00236209 · DOI · Paper page
  19. 10.1109/10.68206 · DOI
  20. stein, 1975, principles underlying new methods for chronic neural recording, Le Journal Canadien des Sciences Neurologiques, 235
  21. 10.1109/TBME.1987.325979 · DOI · Paper page
  22. 10.1109/TBME.1986.325808 · DOI · Paper page
  23. 10.1109/10.68205 · DOI
  24. 10.1111/j.1525-1594.1997.tb04661.x · DOI · Paper page
  25. 10.1002/eej.4390960517 · doi:10.1002/eej.4390960517
  26. webster, 1992, artificial sensors suitable for closed-loop control of fns, Neural Prostheses Replacing Motor Function After Disease or Disability, 88
  27. nathan, 1993, control strategies in fns systems for the upper extremities, Crit Rev Biomed Eng, 21, 485
  28. 10.1109/IEMBS.1993.979133 · DOI
  29. 10.1109/10.32108 · DOI · Paper page
  30. 10.1007/BF00242914 · DOI
  31. 10.1109/86.296344 · DOI · Paper page
  32. 10.1109/86.296345 · DOI · Paper page
  33. 10.1016/0165-0270(81)90033-9 · DOI
  34. 10.1109/10.32109 · DOI · Paper page
  35. edgar, 1996, a multiple sensor recording pacemaker for diagnosis and research, IEE Colloquium on Cardiac Pacing and Electrical Stimulation of the Heart (Ref No 1996/169), 6/1
  36. 10.1109/86.331566 · DOI
  37. 10.1016/0006-8993(91)91126-L · DOI
  38. 10.1016/0006-8993(66)90056-4 · DOI · Paper page
  39. 10.1385/0-89603-185-3:65 · DOI · Paper page

Cited by

See all 112

Metadata

Authors
Haugland, M., Lickel, A., Haase, J., & Sinkjaer, T.
Venue
IEEE Transactions on Rehabilitation Engineering
Published
1999-06
Volume
7
Issue
2
Pages
215-227
ISSN
1063-6528 (ISSN-L)
OpenAlex
W2130603866
Cited by
112
References
5
FWCI
9.11
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Control of FES thumb force using slip information obtained from the cutaneous electroneurogram in quadriplegic man. https://app.cochat.ai/papers/10.1109/86.769412
The paper
Haugland, M., Lickel, A., Haase, J., & Sinkjaer, T. (1999). Control of FES thumb force using slip information obtained from the cutaneous electroneurogram in quadriplegic man. IEEE Transactions on Rehabilitation Engineering. https://doi.org/10.1109/86.769412

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.