The DOI matches its Crossref record; 126 of the 126 references it cites were found in a registry or an index.
Toward Pervasive Gait Analysis With Wearable Sensors: A Systematic Review
Abstract
After decades of evolution, measuring instruments for quantitative gait analysis have become an important clinical tool for assessing pathologies manifested by gait abnormalities. However, such instruments tend to be expensive and require expert operation and maintenance besides their high cost, thus limiting them to only a small number of specialized centers. Consequently, gait analysis in most clinics today still relies on observation-based assessment. Recent advances in wearable sensors, especially inertial body sensors, have opened up a promising future for gait analysis. Not only can these sensors be more easily adopted in clinical diagnosis and treatment procedures than their current counterparts, but they can also monitor gait continuously outside clinics - hence providing seamless patient analysis from clinics to free-living environments. The purpose of this paper is to provide a systematic review of current techniques for quantitative gait analysis and to propose key metrics for evaluating both existing and emerging methods for qualifying the gait features extracted from wearable sensors. It aims to highlight key advances in this rapidly evolving research field and outline potential future directions for both research and clinical applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Determining Lyapunov exponents from a time series
Wolf, A., Swift, J. B., Swinney, H. L., & Vastano, J. A. (1985) · Physica D: Nonlinear Phenomena · doi:10.1016/0167-2789(85)90011-9 · Cited by 9,499
Biomechanics and motor control of human movement
(1990) · Choice Reviews Online · doi:10.5860/choice.28-2135 · Cited by 8,451
Goetz, C. G., Tilley, B. C., Shaftman, S. R., Stebbins, G. T., Fahn, S., Martinez‐Martin, P., Poewe, W., Sampaio, C., Stern, M. B., Dodel, R., et al. (2008) · Movement Disorders · doi:10.1002/mds.22340 · Cited by 7,536
Biomechanics and Motor Control of Human Movement
Winter, D. A. (2009) · Wiley eBooks · doi:10.1002/9780470549148 · Cited by 6,066
Gait speed and survival in older adults.
Studenski, S. (2011) · JAMA · doi:10.1001/jama.2010.1923 · Cited by 4,558 · cited 2×
“In geriatrics, gait analysis is playing a more important role [23].”
BackgroundA practical method for calculating largest Lyapunov exponents from small data sets
Rosenstein, M. T., Collins, J. J., & De Luca, C. J. (1993) · Physica D: Nonlinear Phenomena · doi:10.1016/0167-2789(93)90009-p · Cited by 3,486
Gait variability and fall risk in community-living older adults: A 1-year prospective study
Hausdorff, J. M., Rios, D. A., & Edelberg, H. K. (2001) · Archives of Physical Medicine and Rehabilitation · doi:10.1053/apmr.2001.24893 · Cited by 2,313
Elliptic Fourier features of a closed contour
Kuhl, F. P., & Giardina, C. R. (1982) · Computer Graphics and Image Processing · doi:10.1016/0146-664x(82)90034-x · Cited by 1,839
Clinical Gait Assessment in the Neurologically Impaired
Holden, M. K., Gill, K. M., Magliozzi, M. R., Nathan, J., & Piehl-Baker, L. (1984) · Physical Therapy · doi:10.1093/ptj/64.1.35 · Cited by 1,499 · cited 1×
“As most neurological and neuropsychological diseases can be manifested by changes in gait, gait analysis can help to diagnose and assess the severity of these symptoms [21].”
BackgroundResearch Methods in Biomechanics
Robertson, D. G. E., Caldwell, G. E., Hamill, J., Kamen, G., & Whittlesey, S. N. (2014) · Human Kinetics eBooks · doi:10.5040/9781492595809 · Cited by 1,224
The energy expenditure of normal and pathologic gait
Waters, R. L., & Mulroy, S. (1999) · Gait & Posture · doi:10.1016/s0966-6362(99)00009-0 · Cited by 1,111
Quantitative Gait Markers and Incident Fall Risk in Older Adults
Verghese, J., Holtzer, R., Lipton, R. B., & Wang, C. (2009) · The Journals of Gerontology Series A: Biological Sciences and Medical Sciences · doi:10.1093/gerona/glp033 · Cited by 948
Gait Analysis: An Introduction
Whittle, M. W. (1986) · Cited by 925
Quaternion-Based Extended Kalman Filter for Determining Orientation by Inertial and Magnetic Sensing
Sabatini, A. M. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.875664 · Cited by 887
Incidence and prediction of falls in Parkinson's disease: a prospective multidisciplinary study
Wood, B. H. (2002) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.72.6.721 · Cited by 700
Abnormality of Gait as a Predictor of Non-Alzheimer's Dementia
Verghese, J., Lipton, R. B., Hall, C. B., Kuslansky, G., Katz, M. J., & Buschke, H. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa020441 · Cited by 690
(2006) · doi:10.1007/1-84628-484-8 · Cited by 667
Gait Assessment in Parkinson's Disease: Toward an Ambulatory System for Long-Term Monitoring
Salarian, A., Russmann, H., Vingerhoets, F. J. G., Dehollain, C., Blanc, Y., Burkhard, P. R., & Aminian, K. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.827933 · Cited by 659
Gait Analysis — An Introduction
CONDIE, D. N. (1992) · International Journal of Rehabilitation Research · doi:10.1097/00004356-199206000-00017 · Cited by 650
Assessment of Walking Features From Foot Inertial Sensing
Sabatini, A. M., Martelloni, C., Scapellato, S., & Cavallo, F. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.840727 · Cited by 650
Nonlinear time series analysis of normal and pathological human walking
Dingwell, J. B., & Cusumano, J. P. (2000) · Chaos: An Interdisciplinary Journal of Nonlinear Science · doi:10.1063/1.1324008 · Cited by 596
Simon, S. R. (2004) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.02.047 · Cited by 570
Heesen, C., Böhm, J., Reich, C., Kasper, J., Goebel, M., & Gold, S. (2008) · Multiple Sclerosis Journal · doi:10.1177/1352458508088916 · Cited by 521
Dynamic markers of altered gait rhythm in amyotrophic lateral sclerosis
Hausdorff, J. M., Lertratanakul, A., Cudkowicz, M. E., Peterson, A. L., Kaliton, D., & Goldberger, A. L. (2000) · Journal of Applied Physiology · doi:10.1152/jappl.2000.88.6.2045 · Cited by 504
An extended Kalman filter for quaternion-based orientation estimation using MARG sensors
Marins, J. L., Yun, X., Bachmann, E. R., McGhee, R. B., & Zyda, M. J. (2002) · Proceedings 2001 IEEE/RSJ International Conference on Intelligent Robots and Systems. Expanding the Societal Role of Robotics in the the Next Millennium (Cat. No.01CH37180) · doi:10.1109/iros.2001.976367 · Cited by 499
Sheridan, P. L., Solomont, J., Kowall, N., & Hausdorff, J. M. (2003) · Journal of the American Geriatrics Society · doi:10.1046/j.1532-5415.2003.51516.x · Cited by 494
iTUG, a Sensitive and Reliable Measure of Mobility
Salarian, A., Horak, F. B., Zampieri, C., Carlson-Kuhta, P., Nutt, J. G., & Aminian, K. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2010.2047606 · Cited by 489 · cited 4×
“The paper intuitively explained how to use a geometric model to extract gait speed from inertial sensors and achieved an accuracy with relative errors of 15–25% over a speed range of 0.5–1.7 m/s. Salarian et al. [7] proposed a more precise model using both shank-and thigh-mounted inertial sensors with a better defined…”
MethodInfluentialA practical gait analysis system using gyroscopes
Tong, K., & Granat, M. H. (1999) · Medical Engineering & Physics · doi:10.1016/s1350-4533(99)00030-2 · Cited by 460
Kinematic measures for assessing gait stability in elderly individuals: a systematic review
Hamacher, D., Singh, N. B., Van Dieën, J. H., Heller, M. O., & Taylor, W. R. (2011) · Journal of The Royal Society Interface · doi:10.1098/rsif.2011.0416 · Cited by 401
Clinical Gait Analysis: Theory and Practice
Kirtley, C. (2006) · Cited by 373
Innovative Analyses of Human Movement
Stergiou, N. (2003) · Medical Entomology and Zoology · Cited by 372
Validation of Michigan neuropathy screening instrument for diabetic peripheral neuropathy
Moghtaderi, A., Bakhshipour, A., & Rashidi, H. (2006) · Clinical Neurology and Neurosurgery · doi:10.1016/j.clineuro.2005.08.003 · Cited by 362
Clinical gait analysis: A review
Whittle, M. W. (1996) · Human Movement Science · doi:10.1016/0167-9457(96)00006-1 · Cited by 349
Clinical gait analysis. Theory and practice
Maceira-Suárez, E. (2006) · Revista del Pie y Tobillo · Cited by 341
Ambulatory Position and Orientation Tracking Fusing Magnetic and Inertial Sensing
Roetenberg, D., Slycke, P. J., & Veltink, P. H. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.889184 · Cited by 334
Data management in gait analysis for clinical applications
Benedetti, M., Catani, F., Leardini, A., Pignotti, E., & Giannini, S. (1998) · Clinical Biomechanics · doi:10.1016/s0268-0033(97)00041-7 · Cited by 326
Gait Pattern in the Early Recovery Period after Stroke*
KRAMERS DE QUERVAIN, I. A., SIMON, S. R., LEURGANS, S., PEASE, W. S., & McALLISTER, D. (1996) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199610000-00008 · Cited by 316
Fear of Falling in Elderly Persons: Association With Falls, Functional Ability, and Quality of Life
Li, F., Fisher, K. J., Harmer, P., McAuley, E., & Wilson, N. L. (2003) · The Journals of Gerontology Series B: Psychological Sciences and Social Sciences · doi:10.1093/geronb/58.5.p283 · Cited by 315
The evolution of clinical gait analysis
Sutherland, D. H. (2002) · Gait & Posture · doi:10.1016/s0966-6362(02)00004-8 · Cited by 314
Inertial Sensor-Based Stride Parameter Calculation From Gait Sequences in Geriatric Patients
Rampp, A., Barth, J., Schuelein, S., Gassmann, K.-G., Klucken, J., & Eskofier, B. M. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2368211 · Cited by 303
Classical Dynamics: A Contemporary Approach
José, J. V., & Saletan, E. J. (1998) · Cambridge University Press eBooks · doi:10.1017/cbo9780511803772 · Cited by 303
On-Shoe Wearable Sensors for Gait and Turning Assessment of Patients With Parkinson's Disease
Mariani, B., Jiménez, M. C., Vingerhoets, F. J. G., & Aminian, K. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2227317 · Cited by 278
Anti–basal ganglia antibodies in acute and persistent Sydenham’s chorea
Church, A. J., Cardoso, F., Dale, R. C., Lees, A. J., Thompson, E. J., & Giovannoni, G. (2002) · Neurology · doi:10.1212/wnl.59.2.227 · Cited by 273
Gait analysis of patients following total knee replacement: A systematic review
McClelland, J. A., Webster, K. E., & Feller, J. A. (2007) · The Knee · doi:10.1016/j.knee.2007.04.003 · Cited by 271
Design of patient-specific gait modifications for knee osteoarthritis rehabilitation
Fregly, B. J., Reinbolt, J. A., Rooney, K. L., Mitchell, K. H., & Chmielewski, T. L. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.891934 · Cited by 259
Continuous Monitoring of Turning in Patients with Movement Disability
El-Gohary, M., Pearson, S., McNames, J., Mancini, M., Horak, F., Mellone, S., & Chiari, L. (2013) · Sensors · doi:10.3390/s140100356 · Cited by 258
Rinehart, N. J., Tonge, B. J., Iansek, R., McGinley, J., Brereton, A. V., Enticott, P. G., & Bradshaw, J. L. (2006) · Developmental Medicine & Child Neurology · doi:10.1017/s0012162206001769 · Cited by 250
Fernando, M., Crowther, R., Lazzarini, P., Sangla, K., Cunningham, M., Buttner, P., & Golledge, J. (2013) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2013.08.004 · Cited by 247
Gait analysis : theory and application
Craik, R. L., & Oatis, C. A. (1995) · Mosby eBooks · Cited by 247
DeLuca, P. A., Davis, R. B., ??unpuu, S., Rose, S., & Sirkin, R. (1997) · Journal of Pediatric Orthopaedics · doi:10.1097/00004694-199709000-00007 · Cited by 246
Postural sway as a marker of progression in Parkinson's disease: A pilot longitudinal study
Mancini, M., Carlson-Kuhta, P., Zampieri, C., Nutt, J. G., Chiari, L., & Horak, F. B. (2012) · Gait & Posture · doi:10.1016/j.gaitpost.2012.04.010 · Cited by 221 · cited 1×
“[68] 1/3D accelerometer+3D gyroscope/posterior trunk Sway dispersion, sway velocity, frequency of sway, jerkiness of sway Postural sway in Parkinson’s patients”
BackgroundDifferences Between Local and Orbital Dynamic Stability During Human Walking
Dingwell, J. B., & Kang, H. G. (2007) · Journal of Biomechanical Engineering · doi:10.1115/1.2746383 · Cited by 211
Kinetic Gait Analysis Using a Low-Cost Insole
Howell, A. M., Kobayashi, T., Hayes, H. A., Foreman, K. B., & Bamberg, S. J. M. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2250972 · Cited by 207
Inertial Sensor-Based Methods in Walking Speed Estimation: A Systematic Review
Yang, S., & Li, Q. (2012) · Sensors · doi:10.3390/s120506102 · Cited by 204
Miyazaki, S. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.605434 · Cited by 194
An inverse dynamics model for the analysis, reconstruction and prediction of bipedal walking
Koopman, B., Grootenboer, H. J., & de Jongh, H. J. (1995) · Journal of Biomechanics · doi:10.1016/0021-9290(94)00185-7 · Cited by 178
An EMG-driven model to estimate muscle forces and joint moments in stroke patients
Shao, Q., Bassett, D. N., Manal, K., & Buchanan, T. S. (2009) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2009.09.002 · Cited by 178
Rinehart, N. J., Tonge, B. J., Bradshaw, J. L., Iansek, R., Enticott, P. G., & McGinley, J. (2006) · European Child & Adolescent Psychiatry · doi:10.1007/s00787-006-0530-y · Cited by 173
Biometric and mobile gait analysis for early diagnosis and therapy monitoring in Parkinson's disease
Barth, J., Klucken, J., Kugler, P., Kammerer, T., Steidl, R., Winkler, J., Joachim Hornegger, A., & Eskofier, B. M. (2011) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2011.6090226 · Cited by 166
Gait patterns after anterior cruciate ligament reconstruction
Bulgheroni, P., Bulgheroni, M. V., Andrini, L., Guffanti, P., & Giughello, A. (1997) · Knee Surgery, Sports Traumatology, Arthroscopy · doi:10.1007/s001670050018 · Cited by 162
The gait abnormality of Huntington's disease
Koller, W. C., & Trimble, J. (1985) · Neurology · doi:10.1212/wnl.35.10.1450 · Cited by 161
Ambulatory measurement of ground reaction forces
Veltink, P. H., Liedtke, C., Droog, E., & van der Kooij, H. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.847359 · Cited by 161
In defence of gait analysis. Observation and measurement in gait assessment
Saleh, M., & Murdoch, G. (1985) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.67b2.3980533 · Cited by 159
Granat, M. H., Ferguson, A., Andrews, B. J., & Delargy, M. (1993) · Spinal Cord · doi:10.1038/sc.1993.39 · Cited by 154
How to identify psychogenic disorders of stance and gait
Lempert, T., Brandt, T. H., Dieterich, M., & Huppert, D. (1991) · Journal of Neurology · doi:10.1007/bf00319680 · Cited by 151
The Effect of Preoperative Gait Analysis on Orthopaedic Decision Making
Kay, R. M., Dennis, S. W., Rethlefsen, S. A., et al. (2000) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-200003000-00023 · Cited by 150
Fineberg, D. B., Asselin, P. K., Harel, N. Y., Agranova-Breyter, I., Kornfeld, S. D., Bauman, W. A., & Spungen, A. M. (2013) · Journal of Spinal Cord Medicine · doi:10.1179/2045772313y.0000000126 · Cited by 145
Ambulatory Monitoring of Activities and Motor Symptoms in Parkinson's Disease
Zwartjes, D. G. M., Heida, T., van Vugt, J. P. P., Geelen, J. A. G., & Veltink, P. H. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2049573 · Cited by 141
Ambulatory devices for chronic gait disorders in the elderly.
Hook, F. W. V., Demonbreun, D., & Weiss, B. D. (2003) · PubMed · Cited by 140
Hsu, Y., Chung, P., Wang, W.-H., Pai, M., Wang, C.-Y., Lin, C.-W., Wu, H., & Wang, J.-S. (2014) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2014.2325413 · Cited by 137
The evolution of clinical gait analysis part III – kinetics and energy assessment
Sutherland, D. H. (2004) · Gait & Posture · doi:10.1016/j.gaitpost.2004.07.008 · Cited by 136
Muniz, A. M. S., Liu, H., Lyons, K. E., Pahwa, R., Liu, W., Nobre, F. F., & Nadal, J. (2009) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2009.10.018 · Cited by 136
Dynamic stability differences in fall-prone and healthy adults
Granata, K. P., & Lockhart, T. E. (2007) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2007.06.008 · Cited by 134
Gait in attention deficit hyperactivity disorder: Effects of methylphenidate and dual tasking
Leitner, Y., Barak, R., Giladi, N., Peretz, C., Eshel, R., Gruendlinger, L., & Hausdorff, J. M. (2007) · Journal of Neurology · doi:10.1007/s00415-006-0522-3 · Cited by 131
Neurological gait abnormalities and risk of falls in older adults
Verghese, J., Ambrose, A. F., Lipton, R. B., & Wang, C. (2009) · Journal of Neurology · doi:10.1007/s00415-009-5332-y · Cited by 128
Gait Analysis Alters Decision-Making in Cerebral Palsy
Cook, R. E., Schneider, I., Hazlewood, M. E., Hillman, S. J., & Robb, J. (2003) · Journal of Pediatric Orthopaedics · doi:10.1097/01241398-200305000-00004 · Cited by 126
Lofterød, B., Terjesen, T., Skaaret, I., et al. (2007) · Acta Orthopaedica · doi:10.1080/17453670610013448 · Cited by 125
Forner‐Cordero, A., Koopman, H. F. J. M., & van der Helm, F. C. T. (2005) · Gait & Posture · doi:10.1016/j.gaitpost.2005.02.002 · Cited by 109
Gait dynamics in trisomic mice: quantitative neurological traits of Down syndrome
Hampton, T. G., Stasko, M. R., Kale, A., Amende, I., & Costa, A. C. S. (2004) · Physiology & Behavior · doi:10.1016/j.physbeh.2004.04.006 · Cited by 108
Rietman, J. S., Postema, K., & Geertzen, J. H. B. (2002) · Prosthetics and Orthotics International · doi:10.1080/03093640208726621 · Cited by 106
A Novel Approach to Reducing Number of Sensing Units for Wearable Gait Analysis Systems
Salarian, A., Burkhard, P. R., Vingerhoets, F. J. G., Jolles, B. M., & Aminian, K. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2223465 · Cited by 100
Detection of Freezing of Gait in Parkinson Disease: Preliminary Results
Coste, C., Sijobert, B., Pissard-Gibollet, R., Pasquier, M., Espiau, B., & Gény, C. (2014) · Sensors · doi:10.3390/s140406819 · Cited by 99
Paton, J. S., Stenhouse, E., Bruce, G., Zahra, D., & Jones, R. B. (2012) · Journal of Foot and Ankle Research · doi:10.1186/1757-1146-5-31 · Cited by 96
A comparison of gait in spinal muscular atrophy, type II and Duchenne muscular dystrophy
Armand, S., Mercier, M., Watelain, É., Patte, K., Pelissier, J. Y., & Rivier, F. (2004) · Gait & Posture · doi:10.1016/j.gaitpost.2004.04.006 · Cited by 95
Alaqtash, M., Sarkodie-Gyan, T., Yu, H., Fuentes, O., Brower, R. D., & Abdelgawad, A. H. K. (2011) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2011.6090063 · Cited by 95
A hidden Markov model-based technique for gait segmentation using a foot-mounted gyroscope
Mannini, A., & Sabatini, A. M. (2011) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2011.6091084 · Cited by 91
Uncertainty of measurement in quantitative medical testing: a laboratory implementation guide.
(2004) · PubMed Central · Cited by 90
Sant’Anna, A., Salarian, A., & Wickström, N. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2149521 · Cited by 89
Djuric-Jovicic, M. D., Jovičić, N. S., Radovanovic, S. M., Stanković, I., Popović, M. B., & Kostić, V. (2013) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2287241 · Cited by 86
Cignetti, F., Decker, L. M., & Stergiou, N. (2011) · Annals of Biomedical Engineering · doi:10.1007/s10439-011-0474-3 · Cited by 81
Weiss, M. J., Moran, M. F., Parker, M. E., & Foley, J. T. (2013) · Frontiers in Integrative Neuroscience · doi:10.3389/fnint.2013.00033 · Cited by 78
Local Stability of the Trunk in Patients with Degenerative Cerebellar Ataxia During Walking
Chini, G., Ranavolo, A., Draicchio, F., Casali, C., Conte, C., Martino, G., Leonardi, L., Padua, L., Coppola, G., Pierelli, F., et al. (2016) · The Cerebellum · doi:10.1007/s12311-016-0760-6 · Cited by 63
Gait characterization for osteoarthritis patients using wearable gait sensors (H-Gait systems)
TADANO, S., Takeda, R., Sasaki, K., Fujisawa, T., & Tohyama, H. (2016) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2016.01.017 · Cited by 61
Bolink, S. A. A. N., van Laarhoven, S. N., Lipperts, M., Heyligers, I. C., & Grimm, B. P. (2012) · Physiological Measurement · doi:10.1088/0967-3334/33/11/1947 · Cited by 59
Presenting joint kinematics of human locomotion using phase plane portraits and Poincaré maps
Hürmüzlü, Y., Başdoğan, Ç., & Carollo, J. J. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90199-6 · Cited by 59
Spatial and temporal parameters of gait disturbances in schizophrenic patients
Putzhammer, A., Heindl, B., Broll, K., Pfeiff, L., Perfahl, M., & Hajak, G. (2003) · Schizophrenia Research · doi:10.1016/s0920-9964(03)00090-2 · Cited by 57
Vathsangam, H., Emken, A., Spruijt‐Metz, D., & Sukhatme, G. S. (2010) · International Conference on Pervasive Computing Technologies for Healthcare · doi:10.4108/icst.pervasivehealth2010.8786 · Cited by 54
Greene, B. R., Rutledge, S. M., McGurgan, I. J., McGuigan, C., O’Connell, K., Caulfield, B. M., & Tubridy, N. J. (2015) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2015.2435057 · Cited by 53
Gait Analysis in Cerebral Palsy
Sutherland, D. H. (1978) · Developmental Medicine & Child Neurology · doi:10.1111/j.1469-8749.1978.tb15317.x · Cited by 53
Gait and its assessment in psychiatry.
Sanders, R. D., & Gillig, P. M. (2010) · PubMed Central · Cited by 50
Barth, J., Sunkel, M., Bergner, K., Schickhuber, G., Winkler, J., Klucken, J., & Eskofier, B. M. (2012) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2012.6347146 · Cited by 50
Walking speed and slope estimation using shank-mounted inertial measurement units
Li, Q., Young, M., Naing, V., & Donelan, J. M. (2009) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2009.5209598 · Cited by 45
Gait analysis for patients with Alzheimer'S disease using a triaxial accelerometer
Chung, P., Hsu, Y., Wang, C.-Y., Lin, C.-W., Wang, J.-S., & Pai, M. (2012) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2012.6271484 · Cited by 43
Gait disorder rehabilitation using vision and non-vision based sensors: A systematic review
Ali, A., Sundaraj, K., Ahmad, R. B., Ahamed, N. U., & Islam, M. A. (2012) · Bosnian Journal of Basic Medical Sciences · doi:10.17305/bjbms.2012.2484 · Cited by 43
Novel method for stride length estimation with body area network accelerometers
Martin, E. (2011) · IEEE Topical Conference on Biomedical Wireless Technologies, Networks, and Sensing Systems (BioWireleSS) · doi:10.1109/biowireless.2011.5724356 · Cited by 41
A concurrent comparison of inertia sensor-based walking speed estimation methods
Laudanski, A. F., Yang, S., & Li, Q. (2011) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2011.6090941 · Cited by 39
Estimate of lower trunk angles in pathological gaits using gyroscope data
Grimpampi, E., Bonnet, V., Taviani, A., & Mazzà, C. (2013) · Gait & Posture · doi:10.1016/j.gaitpost.2013.01.031 · Cited by 39
Ihlen, E. A. F., Weiss, A., Beck, Y., et al. (2016) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2016.03.019 · Cited by 38
Quantitative Description of the Lie-to-Sit-to-Stand-to-Walk Transfer by a Single Body-Fixed Sensor
Bagalà, F., Klenk, J., Cappello, A., Chiari, L., Becker, C., & Lindemann, U. (2012) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2012.2230189 · Cited by 33
Extracting Spatio-Temporal Information from Inertial Body Sensor Networks for Gait Speed Estimation
Chen, S., Cunningham, C. L., Lach, J., & Bennett, B. C. (2011) · Wearable and Implantable Body Sensor Networks · doi:10.1109/bsn.2011.40 · Cited by 32
Self-citationXu, X., Batalin, M. A., Kaiser, W. J., & Dobkin, B. H. (2011) · Wearable and Implantable Body Sensor Networks · doi:10.1109/bsn.2011.23 · Cited by 28
Pull test estimation in Parkinson's disease patients using wearable sensor technology
Pasluosta, C. F., Barth, J., Gaßner, H., Klucken, J., & Eskofier, B. M. (2015) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7319050 · Cited by 25
Gait function in adults with Williams syndrome
Hocking, D. R., Rinehart, N., McGinley, J. L., & Bradshaw, J. L. (2008) · Experimental Brain Research · doi:10.1007/s00221-008-1586-3 · Cited by 24
Walking speed and slope estimation using shank-mounted inertial measurement units
Li, Q., Young, M., Naing, V., & Donelan, J. M. (2009) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2009.5209470 · Cited by 24
Assessing Functional Mobility After Lower Limb Reconstruction
Kwasnicki, R. M., Hettiaratchy, S. P., Jarchi, D., Nightingale, C., Wordsworth, M. J., Simmons, J., Yang, G., & Darzi, A. W. (2014) · Annals of Surgery · doi:10.1097/sla.0000000000000711 · Cited by 20
Self-citationGong, J., Lach, J., Qi, Y., & Goldman, M. D. (2015) · Wearable and Implantable Body Sensor Networks · doi:10.1109/bsn.2015.7299400 · Cited by 19
Self-citationBalance and knee extensibility evaluation of hemiplegic gait using an inertial body sensor network
Guo, Y. W., Zhao, G., Liu, Q., Mei, Z., Ivanov, K., & Wang, L. (2013) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-12-83 · Cited by 19
Lower Extremity Kinematic Profile of Gait of Patients After Ankle Fracture: A Case-Control Study
Elbaz, A., Mor, A., Segal, G., Bar, D., Monda, M., Kish, B., Nyska, M., & Palmanovich, E. (2016) · The Journal of Foot & Ankle Surgery · doi:10.1053/j.jfas.2016.04.004 · Cited by 19
Longitudinal high-fidelity gait analysis with wireless inertial body sensors
Barth, A. T., Boudaoud, B., Brantley, J. S., Chen, S., Cunningham, C. L., Kim, T., Powell, H. C., Jr., Ridenour, S. A., Lach, J., & Bennett, B. C. (2010) · Wireless Health · doi:10.1145/1921081.1921107 · Cited by 17
Self-citationEnabling longitudinal assessment of ankle-foot orthosis efficacy for children with cerebral palsy
Chen, S., Cunningham, C. L., Bennett, B. C., & Lach, J. (2011) · Wireless Health · doi:10.1145/2077546.2077551 · Cited by 17
Self-citationDetermination of a Patient's Speed and Stride Length Minimizing Hardware Requirements
Martin, E., Shia, V., & Bajcsy, R. (2011) · Wearable and Implantable Body Sensor Networks · doi:10.1109/bsn.2011.16 · Cited by 16
Wireless realtime motion tracking system using localised orientation estimation
Young, A. D. (2010) · ERA · Cited by 13
Wang, Y., Xu, J. Y., Xu, X., Wu, X., Pottie, G. J., & Kasier, W. (2013) · International Conference on Body Area Networks · doi:10.4108/icst.bodynets.2013.253556 · Cited by 9
Assessment of the e-AR sensor for gait analysis of Parkinson;s Disease patients
Jarchi, D., Peters, A., Lo, B. P. L., Kalliolia, E., Giulio, I. D., Limousin, P. D., Day, B. L., & Yang, G. (2015) · Wearable and Implantable Body Sensor Networks · doi:10.1109/bsn.2015.7299396 · Cited by 8
Self-citationGait Analysis of Autistic Children with Echo State Networks
Noris, B., Nobile, M., Piccini, L., Molteni, M., Keller, F., & Billard, A. (2006) · Infoscience (Ecole Polytechnique Fédérale de Lausanne) · Cited by 7
Nonlinear Feature for Gait Speed Estimation using Inertial Sensors
Chen, S., & Lach, J. (2013) · International Conference on Body Area Networks · doi:10.4108/icst.bodynets.2013.253737 · Cited by 3
Self-citation
Cited by
Wade, L., Needham, L., McGuigan, P., & Bilzon, J. (2022) · PeerJ · doi:10.7717/peerj.12995 · Cited by 384
Wearable sensor-based real-time gait detection: A systematic review
Prasanth, H., Caban, M., Keller, U., Courtine, G., Ijspeert, A., Vallery, H., & von Zitzewitz, J. (2021) · Sensors · doi:10.3390/s21082727 · Cited by 348
“[20] performed a systematic review focusing particularly on quantifiable gait measures and tangible evaluation techniques that are based on wearable sensors, particularly inertial measurement units (IMU).”
BackgroundYadav, S. K., Tiwari, K., Pandey, H. M., & Akbar, S. A. (2021) · Knowledge-Based Systems · doi:10.1016/j.knosys.2021.106970 · Cited by 311
Kobsar, D., Charlton, J. M., Tse, C. T. F., Esculier, J.-F., Graffos, A., Krowchuk, N. M., Thatcher, D., & Hunt, M. A. (2020) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-020-00685-3 · Cited by 305
Internet of things (IoT) applications for elderly care: a reflective review
Tun, S. Y. Y., Madanian, S., & Mirza, F. (2021) · Aging Clinical and Experimental Research · doi:10.1007/s40520-020-01545-9 · Cited by 266
Metadata
- Authors
- Chen, S., Lach, J., Lo, B., & Yang, G.-Z.
- Venue
- IEEE Journal of Biomedical and Health Informatics
- Published
- 2016-11
- Volume
- 20
- Issue
- 6
- Pages
- 1521-1537
- ISSN
- 2168-2194 (ISSN-L)
- 2168-2208
- OpenAlex
- W2560253279
- Cited by
- 443
- References
- 126
- FWCI
- 2.21
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.