A Parylene Self-Locking Cuff Electrode for Peripheral Nerve Stimulation and Recording
The DOI matches its Crossref record; 63 of the 63 references it cites were found in a registry or an index.
Abstract
The cuff electrode provides a stable interface with the peripheral nerve, which has been widely utilized in both basic research and clinical practice over the past few decades. In this paper, we present a microfabricated, parylene-based self-locking cuff electrode. The cuff diameter can be adjusted to accommodate the nerve properly during implantation. This type of cuff electrodes is easy to implant and the cuff was made of the thin, flexible, and biocompatible parylene substrate. Moreover, the integrated parylene cable and pads facilitate the connection with external circuits. Electrochemical properties of electrode sites were characterized by impedance spectroscopy and cyclic voltammetry. The average impedance magnitude and average charge delivery capacity of the Pt electrodes are 8.3 kQ (at 1 kHz) and 2.8 mC/cm2, respectively. Using the proposed cuff electrodes, the evoked compound action potentials of the rat sciatic nerve were successfully recorded. Electrical stimulation tests proved the feasibility of selective stimulation of tibial and peroneal fascicles within the rat sciatic nerve. This type of cuff electrodes induced only a benign foreign body reaction and did not damage the axons within the rat sciatic nerve over 11 weeks of an implantation period.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Various adapted peripheral electrodes have been proposed, such as implants around the nerve (cuff electrodes[351] and flat interface nerve electrodes (FINE)[352]), longitudinally through the nerves (wire[353] and longitudinal interfascicular electrodes (LIFE)[354]), and through the nerves via shafts (such as transverse interfascicular multichannel electrodes (TIME)[355]).”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [351]
In the citing paper
“Acute and chronic (11 weeks) implantation in rat sciatic nerve demonstrated its capability of selective stimulation.”
From Interfaces with the peripheral nervous system for the control of a neuroprosthetic limb: a review (2020) · cites this paper as [63]
In the citing paper
“For instance, selectively recruiting different layers in the peripheral nerve results in a graded force generation in various muscle groups23–25.”
From A flexible three-dimensional electrode mesh: An enabling technology for wireless brain–computer interface prostheses (2016) · cites this paper as [23]
Citations
Cites
Neural Stimulation and Recording Electrodes
Cogan, S. F. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160518 · Cited by 2,243
Electrical stimulation of excitable tissue: design of efficacious and safe protocols
Merrill, D. R., Bikson, M., & Jefferys, J. G. R. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.10.020 · Cited by 2,078 · cited 1×
“Therefore, tissue damage induced by system power and stimulation can be minimized [22].”
BackgroundNavarro, X., Krueger, T. B., Lago, N., Micera, S., Stieglitz, T., & Dario, P. (2005) · Journal of the Peripheral Nervous System · doi:10.1111/j.1085-9489.2005.10303.x · Cited by 845
Functional Electrical Stimulation for Neuromuscular Applications
Peckham, P. H., & Knutson, J. S. (2005) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.6.040803.140103 · Cited by 784
Reversing pathological neural activity using targeted plasticity
Engineer, N. D., Riley, J. R., Seale, J. D., Vrana, W. A., Shetake, J. A., Sudanagunta, S. P., Borland, M. S., & Kilgard, M. P. (2011) · Nature · doi:10.1038/nature09656 · Cited by 668
Chronic vagus nerve stimulation: A new and promising therapeutic approach for chronic heart failure
De Ferrari, G. M., Crijns, H. J. G. M., Borggrefe, M., Milasinovic, G., Smid, J., Zabel, M., Gavazzi, A., Sanzo, A., Dennert, R., Kuschyk, J., et al. (2011) · European Heart Journal · doi:10.1093/eurheartj/ehq391 · Cited by 523
Hassler, C., Boretius, T., & Stieglitz, T. (2011) · Journal of Polymer Science Part B: Polymer Physics · doi:10.1002/polb.22169 · Cited by 501
A transverse intrafascicular multichannel electrode (TIME) to interface with the peripheral nerve
Boretius, T., Badia, J., Pascual-Font, A., Schuettler, M., Navarro, X., Yoshida, K., & Stieglitz, T. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.05.010 · Cited by 468 · cited 1×
“intrafascicular electrodes that are placed within fascicles in the nerve and directly contacted with the target fibers, such as fine wires [26], [27] and silicon or polyimide probes [28], [29], cuff electrodes are safer and more reliable for chronic implan-”
BackgroundA spiral nerve cuff electrode for peripheral nerve stimulation
Naples, G. G., Mortimer, J. T., Scheiner, A., & Sweeney, J. D. (1988) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.8670 · Cited by 415 · cited 2×
“Additionally, the bulky and inflexible cuff and lead wires may cause neural damage due to possible stretching or rubbing of the nerve after implantation [46].”
BackgroundFunctionally selective peripheral nerve stimulation with a flat interface nerve electrode
Tyler, D. J., & Durand, D. M. (2002) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2002.806840 · Cited by 398
Selective Stimulation of Cat Sciatic Nerve Using an Array of Varying-Length Microelectrodes
Branner, A., Stein, R. B., & Normann, R. A. (2001) · Journal of Neurophysiology · doi:10.1152/jn.2001.85.4.1585 · Cited by 359 · cited 2×
“tation [28], [30], [31], though they have a lower selectivity for stimulation and recording.”
BackgroundRODGER, D., FONG, A., LI, W., AMERI, H., AHUJA, A., GUTIERREZ, C., LAVROV, I., ZHONG, H., MENON, P., & MENG, E. (2008) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2007.10.069 · Cited by 325
Selective control of muscle activation with a multipolar nerve cuff electrode
Veraart, C., Grill, W. M., & Mortimer, J. T. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.237694 · Cited by 320
Chronic Nerve Compression—an Experimental Model in the Rat
Mackinnon, S. E., Dellon, A. L., Hudson, A. R., & Hunter, D. A. (1984) · Annals of Plastic Surgery · doi:10.1097/00000637-198408000-00004 · Cited by 307
Treating Obstructive Sleep Apnea with Hypoglossal Nerve Stimulation
Eastwood, P. R., Barnes, M., Walsh, J. H., Maddison, K. J., Hee, G., Schwartz, A. R., Smith, P. L., Malhotra, A., McEvoy, R. D., Wheatley, J. R., et al. (2011) · Sleep · doi:10.5665/sleep.1380 · Cited by 280
Implanted upper airway stimulation device for obstructive sleep apnea
Van de Heyning, P. H., Badr, M. S., Baskin, J. Z., Cramer Bornemann, M. A., De Backer, W. A., Dotan, Y., Hohenhorst, W., Knaack, L., Lin, H., Maurer, J. T., et al. (2012) · The Laryngoscope · doi:10.1002/lary.23301 · Cited by 261
A multielectrode array for intrafascicular recording and stimulation in sciatic nerve of cats
Branner, A., & Normann, R. A. (2000) · Brain Research Bulletin · doi:10.1016/s0361-9230(99)00231-2 · Cited by 234
Modulation of Muscle Force by Recruitment During Intramuscular Stimulation
Crago, P. E., Peckham, P. H., & Thrope, G. B. (1980) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1980.326592 · Cited by 216 · cited 1×
“Cuff electrodes offer several advantages over other commonly used electrodes such as intramuscular, epimysial and surface electrodes [19], [20].”
BackgroundCuff electrodes for chronic stimulation and recording of peripheral nerve activity
Loeb, G. E., & Peck, R. A. (1996) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(95)00123-9 · Cited by 215
Polyimide cuff electrodes for peripheral nerve stimulation
Rodri´guez, F. J., Ceballos, D., Schu¨ttler, M., Valero, A., Valderrama, E., Stieglitz, T., & Navarro, X. (2000) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(00)00192-8 · Cited by 207 · cited 1×
“To avoid tension, the Parylene ribbon cable was carefully routed and the connector was positioned over the skin of the thigh [48].”
BackgroundA nerve cuff technique for selective excitation of peripheral nerve trunk regions
Sweeney, J. D., Ksienski, D. A., & Mortimer, J. T. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.55681 · Cited by 196
Pratt, C. A., Chanaud, C. M., & Loeb, G. E. (1991) · Experimental Brain Research · doi:10.1007/bf00229407 · Cited by 177
Chronically implanted intrafascicular recording electrodes
Lefurge, T., Goodall, E., Horch, K., Stensaas, L., & Schoenberg, A. (1991) · Annals of Biomedical Engineering · doi:10.1007/bf02368469 · Cited by 172
Waters, R. L., McNeal, D. R., Faloon, W., & Clifford, B. (1985) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198567050-00016 · Cited by 156 · cited 1×
“There are some reports showing that the cuff electrodes have been in use for as long as 15 years [32], [33].”
BackgroundSputtered Iridium Oxide Films as Charge Injection Material for Functional Electrostimulation
Slavcheva, E., Vitushinsky, R., Mokwa, W., & Schnakenberg, U. (2004) · Journal of The Electrochemical Society · doi:10.1149/1.1747881 · Cited by 154 · cited 1×
“CV graph, as indicated in the following equation [54]:”
Polasek, K. H., Hoyen, H. A., Keith, M. W., Kirsch, R. F., & Tyler, D. J. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2032603 · Cited by 142 · cited 1×
“fecal incontinence [11], bladder control [12], activation of paralyzed extremities [13], [14], and treatment of obstructive sleep apnea (OSA) [15]–[18].”
BackgroundMatzel, K. E., Stadelmaier, U., Hohenfellner, M., & Hohenberger, W. (2001) · Diseases of the Colon & Rectum · doi:10.1007/bf02234822 · Cited by 130
Novel flexible Parylene neural probe with 3D sheath structure for enhancing tissue integration
Kuo, J. T. W., Kim, B. J., Hara, S. A., Lee, C. D., Gutierrez, C. A., Hoang, T. Q., & Meng, E. (2013) · Lab Chip · doi:10.1039/c2lc40935f · Cited by 127
Electrical stimulation of the hypoglossal nerve in the treatment of obstructive sleep apnea
Kezirian, E. J., Boudewyns, A. N., Eisele, D. W., Schwartz, A. R., Smith, P. L., de Heyning, P. V., & Backer, W. A. D. (2010) · Sleep Medicine Reviews · doi:10.1016/j.smrv.2009.10.009 · Cited by 123
Assessment of the biocompatibility of photosensitive polyimide for implantable medical device use
Sun, Y., Lacour, S. P., Brooks, R. A., Rushton, N., Fawcett, J., & Cameron, R. E. (2009) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.32125 · Cited by 122
An implantable neuroprosthesis for standing and walking in paraplegia: 5-year patient follow-up
Guiraud, D., Stieglitz, T., Koch, K. P., Divoux, J.-L., & Rabischong, P. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/4/003 · Cited by 117
Excitation properties of the right cervical vagus nerve in adult dogs
Castoro, M. A., Yoo, P. B., Hincapie, J. G., Hamann, J. J., Ruble, S. B., Wolf, P. D., & Grill, W. M. (2010) · Experimental Neurology · doi:10.1016/j.expneurol.2010.09.011 · Cited by 112
Yoo, P. B., & Durand, D. M. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.851482 · Cited by 106
Loeb, G. E. (1993) · Experimental Brain Research · doi:10.1007/bf00230446 · Cited by 98
Selective activation of muscles using peripheral nerve electrodes
McNeal, D. R., & Bowman, B. R. (1985) · Medical & Biological Engineering & Computing · doi:10.1007/bf02446866 · Cited by 97
Cuff electrodes for long-term recording of natural sensory information
Struijk, J. J., Thomsen, M., Larsen, J. O., & Sinkjaer, T. (1999) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.765194 · Cited by 97 · cited 1×
“recording electroneurograms (ENGs) [8]–[10], treatment of”
Larsen, J. O., Thomsen, M., Haugland, M., & Sinkjær, T. (1998) · Acta Neuropathologica · doi:10.1007/s004010050907 · Cited by 96
Fabrication and characteristics of an implantable, polymer-based, intrafascicular electrode
Lawrence, S. M., Dhillon, G. S., & Horch, K. W. (2003) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(03)00231-0 · Cited by 93
Mortimer, J. T. (1981) · Comprehensive physiology · doi:10.1002/cphy.cp010205 · Cited by 90
A flexible method for fabrication of nerve cuff electrodes
Haugland, M. (2002) · Proceedings of 18th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.1996.656992 · Cited by 79
Selective stimulation of sacral nerve roots for bladder control: A study by computer modeling
Rijkhoff, N. J. M., Holsheimer, J., Koldewijn, E. L., Struijk, J. J., van Kerrebroeck, P. E. V., Debruyne, F. M. J., & Wijkstra, H. (1994) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.293215 · Cited by 77
González, C., & Rodríguez, M. (1997) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(96)02202-9 · Cited by 75
PERIPHERAL NERVE AND MUSCLE STIMULATION
Mortimer, J. T., & Bhadra, N. (2004) · Series on bioengineering and biomedical engineering · doi:10.1142/9789812561763_0020 · Cited by 74
Chapter 2 Bidirectional Interfaces with the Peripheral Nervous System
Micera, S., & Navarro, X. (2009) · International Review of Neurobiology · doi:10.1016/s0074-7742(09)86002-9 · Cited by 69 · cited 1×
“ing to international standard “Biological Evaluation of Medical Devices” (ISO 10093) [3], and some biological evaluations of the polyimide PI2611 as substrate material shows poor viability of fibroblasts on the polyimide surface [50], which”
BackgroundA hybrid silicon–parylene neural probe with locally flexible regions
Kim, E. G. R., John, J. K., Tu, H., Zheng, Q., Loeb, J. A., Zhang, J., & Xu, Y. P. (2014) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2014.01.048 · Cited by 66
Wang, R., Huang, X., Liu, G., Wang, W., Dong, F., & Li, Z. (2010) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2009.2039773 · Cited by 63
Self-citationChronic Measurement of the Stimulation Selectivity of the Flat Interface Nerve Electrode
Leventhal, D. K., & Durand, D. M. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.827535 · Cited by 55 · cited 1×
“cause the nerve compression induced injury during chronic implantation [41]–[44], while an oversized cuff will lead to a poor contact between the electrode sites and the target nerve [45].”
Background(2001) · PubMed · Cited by 52
Romero, E., Denef, J. F., Delbeke, J., Robert, A., & Veraart, C. (2001) · Medical & Biological Engineering & Computing · doi:10.1007/bf02345271 · Cited by 49
Chu, J.-U., Song, K.-I., Han, S., Lee, S. H., Kim, J., Kang, J. Y., Hwang, D., Suh, J.-K. F., Choi, K., & Youn, I. (2012) · Physiological Measurement · doi:10.1088/0967-3334/33/6/943 · Cited by 47
Lee, S. H., Jung, J. H., Chae, Y. M., Suh, J.-K. F., & Kang, J. Y. (2010) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/20/3/035015 · Cited by 44
Parylene flexible neural probe with micro fluidic channel
Takeuchi, S., Yoshida, Y., Ziegler, D., Mabuchi, K., & Suzuki, T. (2004) · IEEE International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/mems.2004.1290559 · Cited by 43
A wireless slanted optrode array with integrated micro leds for optogenetics
Kwon, K. Y., Lee, H., Ghovanloo, M., Weber, A. J., & Li, W. (2014) · IEEE International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/memsys.2014.6765765 · Cited by 43
A simple cuff electrode for nerve recording and stimulation in acute experiments on small animals
Fenik, V. B., Fenik, P., & Kubin, L. K. (2001) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(01)00340-5 · Cited by 36
The malleability of gold: An explanation of its unique mode of deformation
Nutting, J., & Nuttall, J. (1977) · Gold bulletin · doi:10.1007/bf03216517 · Cited by 33
Krarup, C., Loeb, G. E., & Pezeshkpour, G. H. (1989) · Muscle & Nerve · doi:10.1002/mus.880121108 · Cited by 28
Integrated parylene-cabled silicon probes for neural prosthetics
Huang, R., Pang, C., Tai, Y. C., Emken, J., Ustun, C., Andersen, R., & Burdick, J. (2008) · 2008 IEEE 21st International Conference on Micro Electro Mechanical Systems · doi:10.1109/memsys.2008.4443637 · Cited by 23
Closed-loop stimulation of hypoglossal nerve in a dog model of upper airway obstruction
Sahin, M., Durand, D. H., & Haxhiu, M. A. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.846686 · Cited by 22
Yu, H., Zheng, N., Wang, W., Wang, S., Zheng, X., & Li, Z. (2013) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2013.2262591 · Cited by 20
Self-citationDiaphragm pacing by electrical stimulation of the phrenic nerve
Glenn, W. W., & Phelps, M. L. (1985) · Neurosurgery · doi:10.1097/00006123-198512000-00021 · Cited by 15
Development of individually-addressable parylene microtube arrays
Li, Y., Tu, H., Iezzi, R., Finlayson, P. G., & Xu, Y. P. (2011) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/21/11/115005 · Cited by 15
Long-term spinal reflex studies in awake behaving mice
Carp, J. S., Tennissen, A. M., Chen, X. Y., Schalk, G., & Wolpaw, J. R. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.05.012 · Cited by 13
A cable-tie-type parylene cuff electrode for peripheral nerve interfaces
Yu, H., Xiong, W., Zhang, H., Wang, W., & Li, Z. (2014) · 2014 IEEE 27th International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/memsys.2014.6765560 · Cited by 10 · cited 2×
“cuff electrode and preliminary experiments in peripheral nerve recording and stimulation [1].”
BackgroundSelf-citation
Cited by
Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics
Heng, W., Solomon, S., & Gao, W. (2022) · Advanced Materials · doi:10.1002/adma.202107902 · Cited by 609
Liang, Y., Offenhäusser, A., Ingebrandt, S., & Mayer, D. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202100061 · Cited by 239
Micromachining of Parylene C for bioMEMS
Kim, B. J., & Meng, E. (2016) · Polymers for Advanced Technologies · doi:10.1002/pat.3729 · Cited by 204
Implantable neurotechnologies: a review of micro- and nanoelectrodes for neural recording
Patil, A. C., & Thakor, N. V. (2016) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-015-1430-4 · Cited by 175
Review of polymer MEMS micromachining
Kim, B., & Meng, E. F. (2015) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/26/1/013001 · Cited by 171
Metadata
- Authors
- Yu, H., Xiong, W., Zhang, H., Wang, W., & Li, Z.
- Affiliations
- Peking University (CN)
- Venue
- Journal of Microelectromechanical Systems
- Published
- 2014-10
- Volume
- 23
- Issue
- 5
- Pages
- 1025-1035
- ISSN
- 1057-7157 (ISSN-L)
- 1941-0158
- OpenAlex
- W2067747145
- Semantic Scholar
- 4be6eaa64a2a5f85a34042d10fe2d9155bdaca3a
- Cited by
- 56
- References
- 63
- Citations by year
- 2026: 2 · 2025: 2 · 2024: 5 · 2023: 3 · 2022: 4 · 2021: 11 · 2020: 1 · 2019: 5 · 2018: 9 · 2017: 5 · 2016: 6 · 2015: 3
- FWCI
- 2.13
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Microelectromechanical Systems (publishedVersion)
- Funders
- National Basic Research Program of China (2011CB707505)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Neuroscience › Neurology › Vagus Nerve Stimulation Research
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Keywords
- cuff electrodes, parylene, peripheral nerve stimulation, peripheral nerve recording, microfabrication, electrode impedance, platinum electrode, sciatic nerve, compound action potential, foreign body reaction
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.