The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
A Minimally Invasive 64-Channel Wireless μECoG Implant
Open accessAbstract
Emerging applications in brain–machine interface systems require high-resolution, chronic multisite cortical recordings, which cannot be obtained with existing technologies due to high power consumption, high invasiveness, or inability to transmit data wirelessly. In this paper, we describe a microsystem based on electrocorticography (ECoG) that overcomes these difficulties, enabling chronic recording and wireless transmission of neural signals from the surface of the cerebral cortex. The device is comprised of a highly flexible, high-density, polymer-based 64-channel electrode array and a flexible antenna, bonded to 2.4 mm × 2.4 mm CMOS integrated circuit (IC) that performs 64-channel acquisition, wireless power and data transmission. The IC digitizes the signal from each electrode at 1 kS/s with 1.2 μV input referred noise, and transmits the serialized data using a 1 Mb/s backscattering modulator. A dual-mode power-receiving rectifier reduces data-dependent supply ripple, enabling the integration of small decoupling capacitors on chip and eliminating the need for external components. Design techniques in the wireless and baseband circuits result in over 16× reduction in die area with a simultaneous 3× improvement in power efficiency over the state of the art. The IC consumes 225 μW and can be powered by an external reader transmitting 12 mW at 300 MHz, which is over 3× lower than IEEE and FCC regulations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gabriel, S., Lau, R. W., & Gabriel, C. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/11/003 · Cited by 4,175 · cited 1×
“It consists of a layered tissue model of the human head with frequency-dependent dielectric properties given in [18], a single-turn loop implanted antenna enclosing the array of 64 electrodes, and an external transmit antenna.”
BackgroundNunez, P. L., & Srinivasan, R. (2006) · doi:10.1093/acprof:oso/9780195050387.001.0001 · Cited by 2,531
Electric Fields of the Brain: The Neurophysics of EEG
Nunez, P. L., & Harth, E. (1982) · Physics Today · doi:10.1063/1.2915137 · Cited by 2,232
Enz, C. C., & Temes, G. C. (1996) · Proceedings of the IEEE · doi:10.1109/5.542410 · Cited by 1,877
Viventi, J., Kim, D.-H., Vigeland, L., Frechette, E. S., Blanco, J. A., Kim, Y.-S., Avrin, A. E., Tiruvadi, V. R., Hwang, S.-W., Vanleer, A. C., et al. (2011) · Nature Neuroscience · doi:10.1038/nn.2973 · Cited by 1,136
Crone, N. (1998) · Brain · doi:10.1093/brain/121.12.2301 · Cited by 1,044
Attentional stimulus selection through selective synchronization between monkey visual areas
Bosman, C. A., Schoffelen, J.-M., Brunet, N., Oostenveld, R., Bastos, A. M., Womelsdorf, T., Rubehn, B., Stieglitz, T., De Weerd, P., & Fries, P. (2012) · Neuron · doi:10.1016/j.neuron.2012.06.037 · Cited by 720
Impedance Characterization and Modeling of Electrodes for Biomedical Applications
Franks, W., Schenker, I., Schmutz, P., & Hierlemann, A. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.847523 · Cited by 659
Reconstructing Speech from Human Auditory Cortex
Pasley, B. N., David, S. V., Mesgarani, N., Flinker, A., Shamma, S. A., Crone, N. E., Knight, R. T., & Chang, E. F. (2012) · PLoS Biology · doi:10.1371/journal.pbio.1001251 · Cited by 604 · cited 7×
“I N ORDER to realize the vision of fully autonomous brain–machine interface (BMI) systems, neural implant devices must not only be effective in their function, but should also meet clinical constraints such as ease of implantation, longevity, safety, and small size.”
BackgroundInfluentialCerebral Astrocyte Response to Micromachined Silicon Implants
Turner, J. N., Shain, W., Szarowski, D. H., Andersen, M., Martins, S., Isaacson, M., & Craighead, H. (1999) · Experimental Neurology · doi:10.1006/exnr.1998.6983 · Cited by 592
Verma, N., Shoeb, A., Bohorquez, J., Dawson, J., Guttag, J., & Chandrakasan, A. P. (2010) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2010.2042245 · Cited by 526
Denison, T., Consoer, K., Santa, W., Avestruz, A.-T., Cooley, J., & Kelly, A. (2007) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2007.908664 · Cited by 451
A MEMS-based flexible multichannel ECoG-electrode array
Rubehn, B., Bosman, C., Oostenveld, R., Fries, P., & Stieglitz, T. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/3/036003 · Cited by 387
Muller, R., Gambini, S., & Rabaey, J. M. (2012) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2011.2163552 · Cited by 338
Self-citationFully integrated wideband high-current rectifiers for inductively powered devices
Ghovanloo, M., & Najafi, K. (2004) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2004.835822 · Cited by 296
A 200 μW Eight-Channel EEG Acquisition ASIC for Ambulatory EEG Systems
Yazicioglu, R. F., Merken, P., Puers, R., & Van Hoof, C. (2008) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2008.2006462 · Cited by 271
Low-Power CMOS Rectifier Design for RFID Applications
Mandal, S., & Sarpeshkar, R. (2007) · IEEE Transactions on Circuits and Systems I: Regular Papers · doi:10.1109/tcsi.2007.895229 · Cited by 269
Surge of neurophysiological coherence and connectivity in the dying brain
Borjigin, J., Lee, U., Liu, T., Pal, D., Huff, S., Klarr, D., Sloboda, J., Hernandez, J., Wang, M. M., & Mashour, G. A. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1308285110 · Cited by 217
A Wireless Implantable Multichannel Microstimulating System-on-a-Chip With Modular Architecture
Ghovanloo, M., & Najafi, K. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.903970 · Cited by 151
A 0.013mm2 5μW DC-coupled neural signal acquisition IC with 0.5V supply
Muller, R., Gambini, S., & Rabaey, J. M. (2011) · Digest of technical papers/Digest of technical papers - IEEE International Solid-State Circuits Conference · doi:10.1109/isscc.2011.5746328 · Cited by 140
Self-citationCan Electrocorticography (ECoG) Support Robust and Powerful Brain-Computer Interfaces?
Schalk, G. (2010) · Frontiers in Neuroengineering · doi:10.3389/fneng.2010.00009 · Cited by 81
A Low-Power ECoG/EEG Processing IC With Integrated Multiband Energy Extractor
Zhang, F., Mishra, A., Richardson, A. G., & Otis, B. P. (2011) · IEEE Transactions on Circuits and Systems I Regular Papers · doi:10.1109/tcsi.2011.2163972 · Cited by 73
Mark, M., Björninen, T., Ukkonen, L., Sydanheimo, L. T., & Rabaey, J. M. (2011) · IEEE Topical Conference on Biomedical Wireless Technologies, Networks, and Sensing Systems (BioWireleSS) · doi:10.1109/biowireless.2011.5724339 · Cited by 63
Self-citationCorrosion Behavior of Parylene-Metal-Parylene Thin Films in Saline
Li, W., Rodger, D. C., Menon, P., & Tai, Y. (2008) · ECS Transactions · doi:10.1149/1.2897437 · Cited by 50
Self-citationFabrication and testing of a large area, high density, parylene MEMS
Ledochowitsch, P., Felus, R. J., Gibboni, R., Miyakawa, A., Bao, S., & Maharbiz, M. M. (2011) · IEEE International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/memsys.2011.5734604 · Cited by 41
Self-citationA 1mm 3 2Mbps 330fJ/b transponder for implanted neural sensors
Michael, M., Chen, Y., Sutardja, C., Tang, C., Gowda, S., Wagner, M., Werthimer, D. J., & Rabaey, J. M. (2011) · Symposium on VLSI Circuits · Cited by 27
Self-citationA Cortical Recording Platform Utilizing ¿ECoG Electrode Arrays
Kim, J., Wilson, J. A., & Williams, J. C. (2007) · Conference proceedings · doi:10.1109/iembs.2007.4353551 · Cited by 25
Sub-mm functional decoupling of electrocortical signals through closed-loop BMI learning
Ledochowitsch, P., Koralek, A. C., Moses, D. A., Carmena, J. M., & Maharbiz, M. M. (2013) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2013.6610825 · Cited by 18
Self-citation
Cited by
Neural recording and modulation technologies
Chen, R., Canales, A., & Anikeeva, P. (2017) · Nature Reviews Materials · doi:10.1038/natrevmats.2016.93 · Cited by 655
Wireless Recording in the Peripheral Nervous System with Ultrasonic Neural Dust
Seo, D., Neely, R. M., Shen, K., Singhal, U., Alon, E., Rabaey, J. M., Carmena, J. M., & Maharbiz, M. M. (2016) · Neuron · doi:10.1016/j.neuron.2016.06.034 · Cited by 557
Self-citationWireless Power Transfer Strategies for Implantable Bioelectronics
Agarwal, K., Jegadeesan, R., Guo, Y.-X., & Thakor, N. V. (2017) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2017.2683520 · Cited by 540
Inter-Technology Backscatter: Towards Internet Connectivity for Implanted Devices
Iyer, V., Talla, V., Kellogg, B., Gollakota, S., & Smith, J. (2016) · Proceedings of the 2016 ACM SIGCOMM Conference · doi:10.1145/2934872.2934894 · Cited by 367
Zhang, M., Tang, Z., Liu, X., & Van der Spiegel, J. (2020) · Nature Electronics · doi:10.1038/s41928-020-0390-3 · Cited by 231
Metadata
- Authors
- Muller, R., Le, H.-P., Li, W., Ledochowitsch, P., Gambini, S., Bjorninen, T., Koralek, A., Carmena, J. M., Maharbiz, M. M., Alon, E., & Rabaey, J. M.
- Venue
- IEEE Journal of Solid-State Circuits
- Published
- 2015-01
- Volume
- 50
- Issue
- 1
- Pages
- 344-359
- ISSN
- 0018-9200 (ISSN-L)
- 1558-173X
- OpenAlex
- W1967356008
- Cited by
- 372
- References
- 28
- FWCI
- 14.24
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.