Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 266

The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.

Implantable Myoelectric Sensors (IMESs) for Intramuscular Electromyogram Recording

Open access
Weir, Richard F., Troyk, Phil R., DeMichele, Glen A., Kerns, Douglas A., Schorsch, Jack F., Maas, Huub·2009·IEEE Transactions on Biomedical Engineering

Abstract

We have developed a multichannel electrogmyography sensor system capable of receiving and processing signals from up to 32 implanted myoelectric sensors (IMES). The appeal of implanted sensors for myoelectric control is that electromyography (EMG) signals can be measured at their source providing relatively cross-talk-free signals that can be treated as independent control sites. An external telemetry controller receives telemetry sent over a transcutaneous magnetic link by the implanted electrodes. The same link provides power and commands to the implanted electrodes. Wireless telemetry of EMG signals from sensors implanted in the residual musculature eliminates the problems associated with percutaneous wires, such as infection, breakage, and marsupialization. Each implantable sensor consists of a custom-designed application-specified integrated circuit that is packaged into a biocompatible RF BION capsule from the Alfred E. Mann Foundation. Implants are designed for permanent long-term implantation with no servicing requirements. We have a fully operational system. The system has been tested in animals. Implants have been chronically implanted in the legs of three cats and are still completely operational four months after implantation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tbme.2008.2005942

Cites

32 of 32 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 32 references

Research works printed but not linked: 9

  1. prilutsky, 2006, effects of self-reinnervation of selected cat ankle extensors on their activity and hindlimb mechanics in slope walking, Proc Soc Neurosci Annu Meeting
  2. schwan, 1995, suspended carrier modulation for transcutaneous telemetry links, Proc 13th Int Symp Biotelem, 27
  3. birdwell, 2008, forward-dynamic musculoskeletal models of the human arm and hand, Great Lakes Biomed Conf
  4. birdwell, 2007, hill-based musculo-skeletal hand models for controlling multi-dof hand prostheses, presented at Society for Neuroscience 28th Annual Meeting
  5. lawrence, 1971, classification of myoelectric patterns for the control of a prosthesis, Proc Control Upper Extremity Prostheses Orthoses, 190
  6. taylor, 1969, development of a myoelectrically controlled prosthetic arm, in Advances in External Control on Human Extremities presented at the Third Int Symp External Control Human Extremities
  7. taylor, 1971, multiple-axis prosthesis control by muscle synergies, Proc Control Upper Extremity Prostheses Orthoses, 181
  8. wirta, 1978, pattern recognition prostheses: a historical perspectivefinal report, Bull Prosthet Res, 10, 8
  9. 10.1016/S0021-9290(97)00015-8 · doi:10.1016/s0021-9290(97)00015-8

Cited by

Metadata

Authors
Weir, R. F., Troyk, P. R., DeMichele, G. A., Kerns, D. A., Schorsch, J. F., & Maas, H.
Venue
IEEE Transactions on Biomedical Engineering
Published
2009-01
Volume
56
Issue
1
Pages
159-171
ISSN
  • 0018-9294 (ISSN-L)
  • 1558-2531
OpenAlex
W2124333487
Cited by
266
References
32
FWCI
2.33
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.