The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Implantable Myoelectric Sensors (IMESs) for Intramuscular Electromyogram Recording
Open accessAbstract
We have developed a multichannel electrogmyography sensor system capable of receiving and processing signals from up to 32 implanted myoelectric sensors (IMES). The appeal of implanted sensors for myoelectric control is that electromyography (EMG) signals can be measured at their source providing relatively cross-talk-free signals that can be treated as independent control sites. An external telemetry controller receives telemetry sent over a transcutaneous magnetic link by the implanted electrodes. The same link provides power and commands to the implanted electrodes. Wireless telemetry of EMG signals from sensors implanted in the residual musculature eliminates the problems associated with percutaneous wires, such as infection, breakage, and marsupialization. Each implantable sensor consists of a custom-designed application-specified integrated circuit that is packaged into a biocompatible RF BION capsule from the Alfred E. Mann Foundation. Implants are designed for permanent long-term implantation with no servicing requirements. We have a fully operational system. The system has been tested in animals. Implants have been chronically implanted in the legs of three cats and are still completely operational four months after implantation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Henry, M. A. (1995) · The Journal of the American Dental Association · doi:10.14219/jada.archive.1995.0108 · Cited by 3,416
A new strategy for multifunction myoelectric control
Hudgins, B., Parker, P., & Scott, R. N. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.204774 · Cited by 2,149
The extraction of neural strategies from the surface EMG
Farina, D., Merletti, R., & Enoka, R. M. (2004) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01070.2003 · Cited by 1,573
Upper-Limb Powered Exoskeleton Design
Perry, J. C., Rosen, J., & Burns, S. (2007) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2007.901934 · Cited by 1,023
Robot Hands and the Mechanics of Manipulation
Mason, M. T., Salisbury, J. K., & Parker, J. K. (1989) · Journal of Dynamic Systems, Measurement, and Control · doi:10.1115/1.3153010 · Cited by 911
A wavelet-based continuous classification scheme for multifunction myoelectric control
Englehart, K., Hudgin, B., & Parker, P. A. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.914793 · Cited by 697
Architecture of the hind limb muscles of cats: Functional significance
Sacks, R. D., & Roy, R. R. (1982) · Journal of Morphology · doi:10.1002/jmor.1051730206 · Cited by 653
Direct neural sensory feedback and control of a prosthetic arm
Dhillon, G. S., & Horch, K. W. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.856072 · Cited by 573
Epidemiologic Overview of Individuals with Upper-Limb Loss and Their Reported Research Priorities
Atkins, D. J., Heard, D. C. Y., & Donovan, W. H. (1996) · JPO Journal of Prosthetics and Orthotics · doi:10.1097/00008526-199600810-00003 · Cited by 508
A myosignal-based powered exoskeleton system
Rosen, J., Brand, M., Fuchs, M. B., & Arcan, M. (2001) · IEEE Transactions on Systems, Man, and Cybernetics - Part A: Systems and Humans · doi:10.1109/3468.925661 · Cited by 437
Research works printed but not linked: 9
- prilutsky, 2006, effects of self-reinnervation of selected cat ankle extensors on their activity and hindlimb mechanics in slope walking, Proc Soc Neurosci Annu Meeting
- schwan, 1995, suspended carrier modulation for transcutaneous telemetry links, Proc 13th Int Symp Biotelem, 27
- birdwell, 2008, forward-dynamic musculoskeletal models of the human arm and hand, Great Lakes Biomed Conf
- birdwell, 2007, hill-based musculo-skeletal hand models for controlling multi-dof hand prostheses, presented at Society for Neuroscience 28th Annual Meeting
- lawrence, 1971, classification of myoelectric patterns for the control of a prosthesis, Proc Control Upper Extremity Prostheses Orthoses, 190
- taylor, 1969, development of a myoelectrically controlled prosthetic arm, in Advances in External Control on Human Extremities presented at the Third Int Symp External Control Human Extremities
- taylor, 1971, multiple-axis prosthesis control by muscle synergies, Proc Control Upper Extremity Prostheses Orthoses, 181
- wirta, 1978, pattern recognition prostheses: a historical perspectivefinal report, Bull Prosthet Res, 10, 8
- 10.1016/S0021-9290(97)00015-8 · doi:10.1016/s0021-9290(97)00015-8
Cited by
State of the Art and Future Directions for Lower Limb Robotic Exoskeletons
Young, A. J., & Ferris, D. P. (2017) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2521160 · Cited by 901
Control of upper limb prostheses: terminology and proportional myoelectric control-a review
Fougner, A., Stavdahl, Ø., Kyberd, P. J., Losier, Y. G., & Parker, P. A. (2012) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2012.2196711 · Cited by 495
Control of Hand Prostheses Using Peripheral Information
Micera, S., Carpaneto, J., & Raspopovic, S. (2010) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2010.2085429 · Cited by 403
Myoelectric control of prosthetic hands: state-of-the-art review
Geethanjali, P. (2016) · Medical Devices: Evidence and Research · doi:10.2147/mder.s91102 · Cited by 342
Toward higher-performance bionic limbs for wider clinical use
Farina, D., Vujaklija, I., Brånemark, R., Bull, A. M. J., Dietl, H., Graimann, B., Hargrove, L. J., Hoffmann, K.-P., Huang, H., Ingvarsson, T., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00732-x · Cited by 263
Self-citationProsthetic Myoelectric Control Strategies: A Clinical Perspective
Roche, A. D., Rehbaum, H., Farina, D., & Aszmann, O. C. (2014) · Current Surgery Reports · doi:10.1007/s40137-013-0044-8 · Cited by 261
Targeted Muscle Reinnervation and Advanced Prosthetic Arms
Cheesborough, J., Smith, L., Kuiken, T., & Dumanian, G. (2015) · Seminars in Plastic Surgery · doi:10.1055/s-0035-1544166 · Cited by 206
Schultz, A. E., & Kuiken, T. A. (2011) · PM&R · doi:10.1016/j.pmrj.2010.06.016 · Cited by 186
Aszmann, O. C., Roche, A. D., Salminger, S., Paternostro-Sluga, T., Herceg, M., Sturma, A., Hofer, C., & Farina, D. (2015) · The Lancet · doi:10.1016/s0140-6736(14)61776-1 · Cited by 152
Ortiz-Catalan, M., Brånemark, R., Håkansson, B., & Delbeke, J. (2012) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-11-33 · Cited by 144
Salminger, S., Sturma, A., Hofer, C., Evangelista, M., Perrin, M., Bergmeister, K. D., Roche, A. D., Hasenoehrl, T., Dietl, H., Farina, D., et al. (2019) · Science Robotics · doi:10.1126/scirobotics.aaw6306 · Cited by 139
“5 mm in diameter and 16-mm long, can be inserted into a muscle during the TMR surgery, and acts as an independent differential amplifier consisting of custom electronics housed within a biocompatible, hermetically sealed ceramic cylinder with titanium end caps (16, 33).”
BackgroundDevelopment of an Implantable Myoelectric Sensor for Advanced Prosthesis Control
Merrill, D. R., Lockhart, J., Troyk, P. R., Weir, R. F., & Hankin, D. L. (2011) · Artificial Organs · doi:10.1111/j.1525-1594.2011.01219.x · Cited by 117
Self-citationInterfaces with the peripheral nervous system for the control of a neuroprosthetic limb: a review
Yildiz, K. A., Shin, A. Y., & Kaufman, K. R. (2020) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-020-00667-5 · Cited by 113
Micera, S., Rossini, P. M., Rigosa, J., Citi, L., Carpaneto, J., Raspopovic, S., Tombini, M., Cipriani, C., Assenza, G., Carrozza, M. C., et al. (2011) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-8-53 · Cited by 100
Vu, P. P., Irwin, Z. T., Bullard, A. J., Ambani, S. W., Sando, I. C., Urbanchek, M. G., Cederna, P. S., & Chestek, C. A. (2018) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2017.2772961 · Cited by 61
Use of probabilistic weights to enhance linear regression myoelectric control
Smith, L. H., Kuiken, T. A., & Hargrove, L. J. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/6/066030 · Cited by 15
Metadata
- Authors
- Weir, R. F., Troyk, P. R., DeMichele, G. A., Kerns, D. A., Schorsch, J. F., & Maas, H.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2009-01
- Volume
- 56
- Issue
- 1
- Pages
- 159-171
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2124333487
- Cited by
- 266
- References
- 32
- FWCI
- 2.33
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.