CoChat

Vibro- and Electrotactile User Feedback on Hand Opening for Myoelectric Forearm Prostheses

Open access
Witteveen, H. J. B., Droog, E. A., Rietman, J. S., Veltink, P. H. · 2012 · IEEE Transactions on Biomedical Engineering

The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.

Abstract

Many of the currently available myoelectric forearm prostheses stay unused because of the lack of sensory feedback. Vibrotactile and electrotactile stimulation have high potential to provide this feedback. In this study, performance of a grasping task is investigated for different hand opening feedback conditions on 15 healthy subjects and validated on three patients. The opening of a virtual hand was controlled by a scroll wheel. Feedback about hand opening was given via an array of eight vibrotactile or electrotactile stimulators placed on the forearm, relating to eight hand opening positions. A longitudinal and transversal orientation of the array and four feedback conditions were investigated: no feedback, visual feedback, feedback through vibrotactile or electrotactile stimulation, and addition of an extra stimulator for touch feedback. No influence of array orientation was shown for all outcome parameters (duration of the task, the percentage of correct hand openings, the mean position error, and the percentage deviations up to one position). Vibrotactile stimulation enhances the performance compared to the nonfeedback conditions. The addition of touch feedback further increases the performance, but at the cost of an increased duration. The same effects were found for the patient group, but the task duration was around 25% larger.

Overview

Integrity signals

Registry

Crossref · 10.1109/tbme.2012.2200678

Cites

23 of 23 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

The text we found for this paper looks like another document, so its claims and self-check weren’t run. The registry and citation checks still apply.

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The text we found for this paper looks like another document, so the self-check wasn’t run.

Citations

Cites

Show all 23 references

Research works printed but not linked: 2

  1. cheung, 2008, Tactile Displays for Orientation Navigation and Communication in Air Sea and Land Environments
  2. cholewiak, 2005, The representation of space through static and dynamic tactile displays, presented at the Proc Virtual Reality Int Conf Conjunction Human Comput Interaction

Cited by

Metadata

Authors
Witteveen, H. J. B., Droog, E. A., Rietman, J. S., & Veltink, P. H.
Affiliations
  • University of Twente (NL)
  • Roessingh Research and Development (NL)
Venue
IEEE Transactions on Biomedical Engineering
Published
2012-08
Volume
59
Issue
8
Pages
2219-2226
ISSN
  • 0018-9294 (ISSN-L)
  • 1558-2531
OpenAlex
W2000332758
Cited by
150
References
23
Citations by year
2026: 2 · 2025: 3 · 2024: 12 · 2023: 13 · 2022: 15 · 2021: 13 · 2020: 13 · 2019: 13 · 2018: 15 · 2017: 8 · 2016: 13 · 2015: 12 · 2014: 11 · 2013: 6 · 2012: 1
FWCI
5.46
Type
journal article
Language
en
Open access
Licence
other-oa
Locations
  • IEEE Transactions on Biomedical Engineering (publishedVersion)
  • PubMed (publishedVersion)
  • University of Twente Research Information (publishedVersion, other-oa)
  • University of Twente Research Information (submittedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
  • Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
  • Life Sciences › Neuroscience › Cognitive Neuroscience › Tactile and Sensory Interactions
Keywords
vibrotactile feedback, electrotactile feedback, sensory feedback, hand opening, grasping tasks, prosthetic hand control, tactile feedback, upper limb amputees
MeSH terms
Adult, Artificial Limbs, Electric Stimulation, Feedback, Hand, Humans, Middle Aged, Movement, Physical Stimulation, Psychomotor Performance, Vibration, Reproducibility of Results

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.