CoChat

Vibrotactile grasping force and hand aperture feedback for myoelectric forearm prosthesis users

Open access
Witteveen, Heidi JB, Rietman, Hans S, Veltink, Peter H · 2015 · Prosthetics & Orthotics International
Cited by 108

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

BACKGROUND: User feedback about grasping force and hand aperture is very important in object handling with myoelectric forearm prostheses but is lacking in current prostheses. Vibrotactile feedback increases the performance of healthy subjects in virtual grasping tasks, but no extensive validation on potential users has been performed. OBJECTIVES: Investigate the performance of upper-limb loss subjects in grasping tasks with vibrotactile stimulation, providing hand aperture, and grasping force feedback. STUDY DESIGN: Cross-over trial. METHODS: A total of 10 subjects with upper-limb loss performed virtual grasping tasks while perceiving vibrotactile feedback. Hand aperture feedback was provided through an array of coin motors and grasping force feedback through a single miniature stimulator or an array of coin motors. Objects with varying sizes and weights had to be grasped by a virtual hand. RESULTS: Percentages correctly applied hand apertures and correct grasping force levels were all higher for the vibrotactile feedback condition compared to the no-feedback condition. With visual feedback, the results were always better compared to the vibrotactile feedback condition. Task durations were comparable for all feedback conditions. CONCLUSION: Vibrotactile grasping force and hand aperture feedback improves grasping performance of subjects with upper-limb loss. However, it should be investigated whether this is of additional value in daily-life tasks. CLINICAL RELEVANCE: This study is a first step toward the implementation of sensory vibrotactile feedback for users of myoelectric forearm prostheses. Grasping force feedback is crucial for optimal object handling, and hand aperture feedback is essential for reduction of required visual attention. Grasping performance with feedback is evaluated for the potential users.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1177/0309364614522260

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Research works printed but not linked: 27

  1. Biddiss, 2007, Upper-limb prosthetics—critical factors in device abandonment, Am J Phys Med Rehabil, 86, 977, 10.1097/PHM.0b013e3181587f6c · DOI · Paper page
  2. Atkins, 1996, Epidemiologic overview of individuals with upper-limb loss and their reported research priorities, J Prosthet Orthot, 8, 2, 10.1097/00008526-199600810-00003 · DOI · Paper page
  3. Peerdeman, 2011, Myoelectric forearm prostheses: state of the art from a user-centered perspective, J Rehabil Res Dev, 48, 719, 10.1682/JRRD.2010.08.0161 · DOI · Paper page
  4. Antfolk, 2013, Sensory feedback in upper limb prosthetics, Expert Rev Med Devices, 10, 45, 10.1586/erd.12.68 · DOI · Paper page
  5. Kaczmarek, 1991, Electrotactile and vibrotactile displays for sensory substitution systems, IEEE T Bio-Med Eng, 38, 1, 10.1109/10.68204 · DOI · Paper page
  6. Jones, 2008, Tactile displays: guidance for their design and application, Hum Factors, 50, 90, 10.1518/001872008X250638 · DOI · Paper page
  7. Cipriani, 2008, On the shared control of an EMG-controlled prosthetic hand: analysis of user-prosthesis interaction, IEEE Trans Robot, 24, 170, 10.1109/TRO.2007.910708 · DOI · Paper page
  8. Chatterjee, 2008, Testing a prosthetic haptic feedback simulator with an interactive force matching task, J Prosthet Orthot, 20, 27, 10.1097/01.JPO.0000311041.61628.be · DOI
  9. Stepp, 2012, Vibrotactile sensory substitution for object manipulation: amplitude versus pulse train frequency modulation, IEEE Trans Neural Syst Rehabil Eng, 20, 31, 10.1109/TNSRE.2011.2170856 · DOI
  10. Pons, 2005, Objectives and technological approach to the development of the multifunctional MANUS upper limb prosthesis, Robotica, 23, 301, 10.1017/S0263574704001328 · DOI
  11. Saunders, 2011, The role of feed-forward and feedback processes for closed-loop prosthesis control, J Neuroeng Rehabil, 8, 60, 10.1186/1743-0003-8-60 · DOI · Paper page
  12. Prior, 1976, Supplemental sensory feedback for the VA/NU myoelectric hand. Background and preliminary designs, Bull Prosthet Res, 10, 170
  13. Dhillon, 2005, Direct neural sensory feedback and control of a prosthetic arm, IEEE Trans Neural Syst Rehabil Eng, 13, 468, 10.1109/TNSRE.2005.856072 · DOI · Paper page
  14. Wheeler, 2010, Investigation of rotational skin stretch for proprioceptive feedback with application to myoelectric systems, IEEE Trans Neural Syst Rehabil Eng, 18, 58, 10.1109/TNSRE.2009.2039602 · DOI
  15. Hunter, 2005, Dissociation of phantom limb phenomena from stump tactile spatial acuity and sensory thresholds, Brain, 128, 308, 10.1093/brain/awh350 · DOI
  16. Haber, 1958, Reactions to loss of limb: physiological and psychological aspects, Ann N Y Acad Sci, 74, 14, 10.1111/j.1749-6632.1958.tb39524.x · DOI
  17. Teuber, 1949, Reorganization of sensory function in amputation stumps—2-point discrimination, Fed Proc, 8, 156
  18. Moore, 1999, Cortical focusing is an alternative explanation for improved sensory acuity on an amputation stump, Neurosci Lett, 270, 185, 10.1016/S0304-3940(99)00478-4 · DOI
  19. O’Boyle, 2001, Human locognosic acuity on the arm varies with explicit and implicit manipulations of attention: implications for interpreting elevated tactile acuity on an amputation stump, Neurosci Lett, 305, 37, 10.1016/S0304-3940(01)01805-5 · DOI
  20. Braune, 1993, Changes in sensation after nerve injury or amputation—the role of central factors, J Neurol Neurosurg Psychiatry, 56, 393, 10.1136/jnnp.56.4.393 · DOI
  21. Sensinger, 2009, Examination of force discrimination in human upper limb amputees with reinnervated limb sensation following peripheral nerve transfer, IEEE Trans Neural Syst Rehabil Eng, 17, 438, 10.1109/TNSRE.2009.2032640 · DOI · Paper page
  22. Hunter, 2008, Stability of phantom limb phenomena after upper limb amputation: a longitudinal study, Neuroscience, 156, 939, 10.1016/j.neuroscience.2008.07.053 · DOI
  23. Green, 1982, The perception of distance and location for dual tactile pressures, Percept Psychophys, 31, 315, 10.3758/BF03202654 · DOI
  24. Cody, 2008, Tactile spatial acuity varies with site and axis in the human upper limb, Neurosci Lett, 433, 103, 10.1016/j.neulet.2007.12.054 · DOI
  25. Cholewiak, 2003, Vibrotactile localization on the arm: effects of place, space, and age, Percept Psychophys, 65, 1058, 10.3758/BF03194834 · DOI · Paper page
  26. Stevens, 1996, Spatial acuity of the body surface over the life span, Somatosens Mot Res, 13, 153, 10.3109/08990229609051403 · DOI · Paper page
  27. Der, 2006, Age and sex differences in reaction time in adulthood: results from the United Kingdom Health and Lifestyle Survey, Psychol Aging, 21, 62, 10.1037/0882-7974.21.1.62 · DOI · Paper page

Cited by

See all 108

Metadata

Authors
Witteveen, H. J., Rietman, H. S., & Veltink, P. H.
Venue
Prosthetics & Orthotics International
Published
2015-06
Volume
39
Issue
3
Pages
204-212
ISSN
0309-3646 (ISSN-L)
OpenAlex
W1992827030
Cited by
108
References
4
FWCI
2.81
Type
journal article
Language
en
Open access
green
Licence
journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Vibrotactile grasping force and hand aperture feedback for myoelectric forearm prosthesis users. https://app.cochat.ai/papers/10.1177/0309364614522260
The paper
Witteveen, H. J., Rietman, H. S., & Veltink, P. H. (2015). Vibrotactile grasping force and hand aperture feedback for myoelectric forearm prosthesis users. Prosthetics & Orthotics International. https://doi.org/10.1177/0309364614522260

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.