Integrated Circuits and Electrode Interfaces for Noninvasive Physiological Monitoring
The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
This paper presents an overview of the fundamentals and state of the-art in noninvasive physiological monitoring instrumentation with a focus on electrode and optrode interfaces to the body, and micropower-integrated circuit design for unobtrusive wearable applications. Since the electrode/optrode-body interface is a performance limiting factor in noninvasive monitoring systems, practical interface configurations are offered for biopotential acquisition, electrode-tissue impedance measurement, and optical biosignal sensing. A systematic approach to instrumentation amplifier (IA) design using CMOS transistors operating in weak inversion is shown to offer high energy and noise efficiency. Practical methodologies to obviate 1/f noise, counteract electrode offset drift, improve common-mode rejection ratio, and obtain subhertz high-pass cutoff are illustrated with a survey of the state-of-the-art IAs. Furthermore, fundamental principles and state-of-the-art technologies for electrode-tissue impedance measurement, photoplethysmography, functional near-infrared spectroscopy, and signal coding and quantization are reviewed, with additional guidelines for overall power management including wireless transmission. Examples are presented of practical dry-contact and noncontact cardiac, respiratory, muscle and brain monitoring systems, and their clinical applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Thermal Agitation of Electricity in Conductors
Johnson, J. B. (1928) · Physical Review · doi:10.1103/physrev.32.97 · Cited by 1,811
A low-power low-noise cmos for amplifier neural recording applications
Harrison, R. R., & Charles, C. (2003) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2003.811979 · Cited by 1,695
A micropower low-noise monolithic instrumentation amplifier for medical purposes
Steyaert, M. S. J., & Sansen, W. M. C. (1987) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.1987.1052869 · Cited by 577
Physiological parameter monitoring from optical recordings with a mobile phone
Scully, C. G., Lee, J., Meyer, J., Gorbach, A. M., Granquist-Fraser, D., Mendelson, Y., & Chon, K. H. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2163157 · Cited by 452
An Energy-Efficient Micropower Neural Recording Amplifier
Wattanapanitch, W., Fee, M., & Sarpeshkar, R. (2007) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2007.907868 · Cited by 441
A 1-V 450-nW fully integrated programmable biomedical sensor interface chip.
Zou, X., Xu, X., Yao, L., & Lian, Y. (2009) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2009.2014707 · Cited by 414
A 128-Channel 6 mW Wireless Neural Recording IC With Spike Feature Extraction and UWB Transmitter
Chae, M. S., Yang, Z., Yuce, M. R., Hoang, L., & Liu, W. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2021607 · Cited by 369
The Design of Integrated Circuits to Observe Brain Activity
Harrison, R. R. (2008) · Proceedings of the IEEE · doi:10.1109/jproc.2008.922581 · Cited by 330
OlssonIII, R. H., Buhl, D. L., Sirota, A. M., Buzsaki, G., & Wise, K. D. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.847540 · Cited by 181
A 0.7-V 17.4-/spl mu/W 3-Lead Wireless ECG SoC
Khayatzadeh, M., Zhang, X., Tan, J., Liew, W.-S., & Lian, Y. (2013) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2013.2279398 · Cited by 73
Cited by
Wearable sensors: modalities, challenges, and prospects
Heikenfeld, J., Jajack, A., Rogers, J., Gutruf, P., Tian, L., Pan, T., Li, R., Khine, M., Kim, J., Wang, J., et al. (2018) · Lab on a Chip · doi:10.1039/c7lc00914c · Cited by 1,434
Bio-Integrated Wearable Systems: A Comprehensive Review
Ray, T. R., Choi, J., Bandodkar, A. J., Krishnan, S., Gutruf, P., Tian, L., Ghaffari, R., & Rogers, J. A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00573 · Cited by 1,350
Real-time neuroimaging and cognitive monitoring using wearable dry EEG
Mullen, T. R., Kothe, C. A. E., Chi, Y. M., Ojeda, A., Kerth, T., Makeig, S., Jung, T.-P., & Cauwenberghs, G. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2481482 · Cited by 795
Self-citationHigh-Value Tunable Pseudo-Resistors Design
Guglielmi, E., Toso, F., Zanetto, F., Sciortino, G., Mesri, A., Sampietro, M., & Ferrari, G. (2020) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2020.2973639 · Cited by 114
A Noninvasive Glucose Monitoring SoC Based on Single Wavelength Photoplethysmography
Hina, A., & Saadeh, W. (2020) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2020.2979514 · Cited by 99
Zheng, Y., Zhan, Z., Chen, Q., Chen, J., Luo, J., Cai, J., Zhou, Y., Chen, K., & Xie, W. (2024) · Advanced Science · doi:10.1002/advs.202405681 · Cited by 38
Metadata
- Authors
- Ha, S., Kim, C., Chi, Y. M., Akinin, A., Maier, C., Ueno, A., & Cauwenberghs, G.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2014-05
- Volume
- 61
- Issue
- 5
- Pages
- 1522-1537
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2025539904
- Cited by
- 141
- References
- 10
- FWCI
- 7.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.