The DOI matches its Crossref record; 54 of the 54 references it cites were found in a registry or an index.
Volume-preserving nonrigid registration of MR breast images using free-form deformation with an incompressibility constraint
Abstract
In this paper, we extend a previously reported intensity-based nonrigid registration algorithm by using a novel regularization term to constrain the deformation. Global motion is modeled by a rigid transformation while local motion is described by a free-form deformation based on B-splines. An information theoretic measure, normalized mutual information, is used as an intensity-based image similarity measure. Registration is performed by searching for the deformation that minimizes a cost function consisting of a weighted combination of the image similarity measure and a regularization term. The novel regularization term is a local volume-preservation (incompressibility) constraint, which is motivated by the assumption that soft tissue is incompressible for small deformations and short time periods. The incompressibility constraint is implemented by penalizing deviations of the Jacobian determinant of the deformation from unity. We apply the nonrigid registration algorithm with and without the incompressibility constraint to precontrast and post-contrast magnetic resonance (MR) breast images from 17 patients. Without using a constraint, the volume of contrast-enhancing lesions decreases by 1%-78% (mean 26%). Image improvement (motion artifact reduction) obtained using the new constraint is compared with that obtained using a smoothness constraint based on the bending energy of the coordinate grid by blinded visual assessment of maximum intensity projections of subtraction images. For both constraints, volume preservation improves, and motion artifact correction worsens, as the weight of the constraint penalty term increases. For a given volume change of the contrast-enhancing lesions (2% of the original volume), the incompressibility constraint reduces motion artifacts better than or equal to the smoothness constraint in 13 out of 17 cases (better in 9, equal in 4, worse in 4). The preliminary results suggest that incorporation of the incompressibility regularization term improves intensity-based free-form nonrigid registration of contrast-enhanced MR breast images by greatly reducing the problem of shrinkage of contrast-enhancing structures while simultaneously allowing motion artifacts to be substantially reduced.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Simplex Method for Function Minimization
Nelder, J. A., & Mead, R. (1965) · The Computer Journal · doi:10.1093/comjnl/7.4.308 · Cited by 28,905
Numerical recipes in C: the art of scientific computing
(1993) · Choice Reviews Online · doi:10.5860/choice.30-5638 · Cited by 17,933
Horn, B. K. P., & Schunck, B. G. (1981) · Artificial Intelligence · doi:10.1016/0004-3702(81)90024-2 · Cited by 10,312
Solutions of Ill-Posed Problems.
Bell, J. B., Tikhonov, A. N., & Arsenin, V. Y. (1978) · Mathematics of Computation · doi:10.2307/2006360 · Cited by 8,101
Horn, B. K., & Schunck, B. G. (1981) · SPIE Proceedings · doi:10.1117/12.965761 · Cited by 7,394
Nonrigid registration using free-form deformations: application to breast mr images
Rueckert, D., Sonoda, L. I., Hayes, C., Hill, D. L. G., Leach, M. O., & Hawkes, D. J. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.796284 · Cited by 5,265
Spline Models for Observational Data.
Muller, H.-G., & Wahba, G. (1991) · Journal of the American Statistical Association · doi:10.2307/2290434 · Cited by 4,928
Principal warps: thin-plate splines and the decomposition of deformations
Bookstein, F. L. (1989) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.24792 · Cited by 4,913
Numerical Recipes--The Art of Scientific Computing.
Fritsch, F. N., Press, W. H., Flannery, B. P., Teukolsky, S. A., & Vetterling, W. T. (1988) · Mathematics of Computation · doi:10.2307/2007938 · Cited by 4,845
Numerical Recipes in C: The Art of Scientific Computing.
Birchenhall, C., Press, W. H., Teukolsky, S. A., Vetterling, W. T., & Flannery, B. P. (1994) · The Economic Journal · doi:10.2307/2234664 · Cited by 4,355
Spline Models for Observational Data
Wahba, G. (1990) · doi:10.1137/1.9781611970128 · Cited by 4,184
Free-form deformation of solid geometric models
Sederberg, T. W., & Parry, S. R. (1986) · ACM SIGGRAPH Computer Graphics · doi:10.1145/15886.15903 · Cited by 2,577
Image matching as a diffusion process: an analogy with maxwell’s demons
Thirion, J.-P. (1998) · Medical Image Analysis · doi:10.1016/s1361-8415(98)80022-4 · Cited by 2,445
An overlap invariant entropy measure of 3D medical image alignment
Studholme, C., Hill, D. L. G., & Hawkes, D. J. (1999) · Pattern Recognition · doi:10.1016/s0031-3203(98)00091-0 · Cited by 2,180
Hill, D. L. G., Batchelor, P. G., Holden, M., & Hawkes, D. J. (2001) · Physics in Medicine and Biology · doi:10.1088/0031-9155/46/3/201 · Cited by 2,093
Numerical Recipes in C: The Art of Scientific Computing
Seiler, M. C., & Seiler, F. A. (1989) · Risk Analysis · doi:10.1111/j.1539-6924.1989.tb01007.x · Cited by 1,346
Deformable templates using large deformation kinematics
Christensen, G. E., Rabbitt, R. D., & Miller, M. I. (1996) · IEEE Transactions on Image Processing · doi:10.1109/83.536892 · Cited by 1,142
Multiresolution elastic matching
Bajcsy, R., & Kovačič, S. (1989) · Computer Vision, Graphics, and Image Processing · doi:10.1016/s0734-189x(89)80014-3 · Cited by 1,106
Alignment by maximization of mutual information
Viola, P., & Wells, W. M. (2002) · Proceedings of IEEE International Conference on Computer Vision · doi:10.1109/iccv.1995.466930 · Cited by 1,082
Scattered data interpolation with multilevel B-splines
Lee, S., Wolberg, G., & Shin, S. Y. (1997) · IEEE Transactions on Visualization and Computer Graphics · doi:10.1109/2945.620490 · Cited by 1,046
Comparison and Evaluation of Retrospective Intermodality Brain Image Registration Techniques
West, J., Fitzpatrick, J. M., Wang, M. Y., Dawant, B. M., Maurer, C. R., Kessler, R. M., Maciunas, R. J., Barillot, C., Lemoine, D., Collignon, A., et al. (1997) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199707000-00007 · Cited by 884
Self-citationRegularization of Inverse Visual Problems Involving Discontinuities
Terzopoulos, D. (1986) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.1986.4767807 · Cited by 767
Studholme, C., Hill, D. L. G., & Hawkes, D. J. (1997) · Medical Physics · doi:10.1118/1.598130 · Cited by 675
Christensen, G. E., & Johnson, H. J. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.932742 · Cited by 636
Hierarchical B-spline refinement
Forsey, D. R., & Bartels, R. H. (1988) · ACM SIGGRAPH Computer Graphics · doi:10.1145/378456.378512 · Cited by 624
Alignment by Maximization of Mutual Information
Viola, P. A. (1995) · doi:10.21236/ada299525 · Cited by 614
Analysis and synthesis of facial image sequences using physical and anatomical models
Terzopoulos, D., & Waters, K. (1993) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.216726 · Cited by 538
Meyer, C. R., Boes, J. L., Kim, B., Bland, P. H., Zasadny, K. R., Kison, P. V., Koral, K., Frey, K. A., & Wahl, R. L. (1997) · Medical Image Analysis · doi:10.1016/s1361-8415(97)85010-4 · Cited by 460
Volumetric transformation of brain anatomy
Christensen, G. E., Joshi, S. C., & Miller, M. I. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.650882 · Cited by 438
A technique for accurate magnetic resonance imaging in the presence of field inhomogeneities
Chang, H., & Fitzpatrick, J. M. (1992) · IEEE Transactions on Medical Imaging · doi:10.1109/42.158935 · Cited by 425
Hajnal, J. V., & Hill, D. (2001) · Lecture notes in computer science · doi:10.1007/978-3-032-25169-5 · Cited by 402
Spatial Transformation and Registration of Brain Images Using Elastically Deformable Models
Davatzikos, C. (1997) · Computer Vision and Image Understanding · doi:10.1006/cviu.1997.0605 · Cited by 375
Rohlfing, T., & Maurer, C. R. (2003) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2003.808506 · Cited by 373
Self-citationSchnabel, J. A., Rueckert, D., Quist, M., Blackall, J. M., Castellano-Smith, A. D., Hartkens, T., Penney, G. P., Hall, W. A., Liu, H., Truwit, C. L., et al. (2001) · Lecture Notes in Computer Science · doi:10.1007/3-540-45468-3_69 · Cited by 355
Structural Image Restoration through Deformable Templates
Amit, Y., Grenander, U., & Piccioni, M. (1991) · Journal of the American Statistical Association · doi:10.1080/01621459.1991.10475053 · Cited by 328
Measures of acutance and shape for classification of breast tumors
Rangayyan, R. M., El-Faramawy, N. M., Desautels, J. E. L., & Alim, O. A. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.650876 · Cited by 318
Handbook of Medical Imaging, Volume 2. Medical Image Processing and Analysis
(2000) · SPIE eBooks · doi:10.1117/3.831079 · Cited by 278
Comparison and evaluation of retrospective intermodality image registration techniques:
West, J. B., Fitzpatrick, J. M., Wang, M. Y., Dawant, B. M., Maurer, Jr., Kessler, R. M., Maciunas, R. J., Barillot, C., Lemoine, D., Collignon, A. M. F., et al. (1996) · SPIE Proceedings · doi:10.1117/12.237936 · Cited by 269
Breast MR imaging: interpretation model.
Nunes, L. W., Schnall, M. D., Orel, S. G., Hochman, M. G., Langlotz, C. P., Reynolds, C. A., & Torosian, M. H. (1997) · Radiology · doi:10.1148/radiology.202.3.9051042 · Cited by 252
Update of Breast MR Imaging Architectural Interpretation Model
Nunes, L. W., Schnall, M. D., & Orel, S. G. (2001) · Radiology · doi:10.1148/radiology.219.2.r01ma44484 · Cited by 208
Deformations Incorporating Rigid Structures
Little, J. A., Hill, D. L. G., & Hawkes, D. J. (1997) · Computer Vision and Image Understanding · doi:10.1006/cviu.1997.0608 · Cited by 193
Automated multimodality image registration using information theory
Collignon, A. M. F. (1995) · Information Processing in Medical Imaging · Cited by 190
Pluim, J. P. W., & Fitzpatrick, J. M. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.819272 · Cited by 189
Accurate alignment of functional EPI data to anatomical MRI using a physics-based distortion model
Studholme, C., Constable, R. T., & Duncan, J. S. (2000) · IEEE Transactions on Medical Imaging · doi:10.1109/42.896788 · Cited by 167
Analysis of dynamic MR breast images using a model of contrast enhancement
Hayton, P., Brady, M., Tarassenko, L., & Moore, N. (1997) · Medical Image Analysis · doi:10.1016/s1361-8415(97)85011-6 · Cited by 154
Comparison and Evaluation of Rigid, Affine, and Nonrigid Registration of Breast MR Images
Denton, E., Sonoda, L. I., Rueckert, D., Rankin, S., Hayes, C., Leach, M. O., Hill, D., & Hawkes, D. J. (1999) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199909000-00031 · Cited by 124
Tanner, C., Schnabel, J. A., Chung, D. H., Clarkson, M. J., Rueckert, D., Hill, D., & Hawkes, D. J. (2000) · Lecture notes in computer science · doi:10.1007/978-3-540-40899-4_33 · Cited by 89
Fitzpatrick, J. M., Hill, D., & Maurer, C. R. (2010) · SPIE eBooks · doi:10.1117/3.831079.ch8 · Cited by 89
Self-citationCachier, P., & Rey, D. (2000) · Lecture notes in computer science · doi:10.1007/978-3-540-40899-4_48 · Cited by 79
Torsten Rohlfing, B., Maurer, C. R., O’Dell, W. G., & Zhong, J. (2001) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.428073 · Cited by 70
Self-citationA three-component deformation model for image-guided surgery
Edwards, P., Hill, D., Little, J. A., & Hawkes, D. J. (1998) · Medical Image Analysis · doi:10.1016/s1361-8415(98)80016-9 · Cited by 66
Torsten Rohlfing, B., & Maurer, C. R. (2001) · Lecture notes in computer science · doi:10.1007/3-540-45468-3_14 · Cited by 63
Self-citationA method for the comparison of biomechanical breast models
Tanner, C., Andreas Degenhard, B., Schnabel, J. A., Smith, A. C., Hayes, C., Sonoda, L. I., Leach, M. O., Hose, D. R., Hill, D., & Hawkes, D. J. (2002) · IEEE Workshop on Mathematical Methods in Biomedical Image Analysis (MMBIA) · doi:10.1109/mmbia.2001.991694 · Cited by 48
Rueckert, D. (2001) · Biomedical engineering series · doi:10.1201/9781420042474.sec3 · Cited by 40
Cited by
Elastix: a toolbox for intensity-based medical image registration
Klein, S., Staring, M., Murphy, K., Viergever, M. A., & Pluim, J. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2035616 · Cited by 4,311
Deformable medical image registration: a survey
Sotiras, A., Davatzikos, C., & Paragios, N. (2013) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2013.2265603 · Cited by 1,587
“In [238], such a strategy was employed to register contrast-enhanced MR breast images.”
MethodMedical image registration: a review
Oliveira, F. P. M., & Tavares, J. M. R. S. (2014) · Computer Methods in Biomechanics and Biomedical Engineering · doi:10.1080/10255842.2012.670855 · Cited by 737
Non-rigid image registration: theory and practice
Crum, W. R., Hartkens, T., & Hill, D. L. G. (2004) · The British Journal of Radiology · doi:10.1259/bjr/25329214 · Cited by 719
Rohlfing, T., Brandt, R., Menzel, R., & Maurer, C. R. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2003.11.010 · Cited by 573
Self-citation
Metadata
- Authors
- Rohlfing, T., Maurer, C. R., Bluemke, D. A., & Jacobs, M. A.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2003-06
- Volume
- 22
- Issue
- 6
- Pages
- 730-741
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2142311337
- Cited by
- 445
- References
- 54
- FWCI
- 21.13
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.