The Fourier reconstruction of a head section
The DOI matches its Crossref record.
Abstract
The Fourier reconstruction may be viewed simply in the spatial domain as the sum of each line integral times a weighting function of the distance from the line to the point of reconstruction. A modified weighting function simultaneously achieves accuracy, simplicity, low computation time, as well as low sensitivity to noise. Using a simulated phantom, the authors compare the Fourier algorithm and a search algorithm. The search algorithm required 12 iterations to obtain a reconstruction of accuracy and resolution comparable to that of the Fourier reconstruction, and was more sensitive to noise. To speed the search algorithm by using fewer interactions leaves decreased resolution in the region just inside the skull which could mask a subdural hematoma.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Feldkamp, L. A., Davis, L. C., & Kress, J. W. (1984) · Journal of the Optical Society of America A · doi:10.1364/josaa.1.000612 · Cited by 6,319
Maximum Likelihood Reconstruction for Emission Tomography
Shepp, L. A., & Vardi, Y. (1982) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1982.4307558 · Cited by 4,429
Self-citationAndersen, A. (1984) · Ultrasonic Imaging · doi:10.1016/0161-7346(84)90008-7 · Cited by 1,812
Fourier Features Let Networks Learn High Frequency Functions in Low Dimensional Domains
Tancik, M., Srinivasan, P. P., Mildenhall, B., Fridovich-Keil, S., Raghavan, N., Singhal, U., Ramamoorthi, R., Barron, J. T., & Ng, R. (2020) · arXiv · doi:10.48550/arxiv.2006.10739 · Cited by 1,459
“We use two datasets for our 2D CT task: randomized Shepp-Logan phantoms [36], and the ATLAS brain dataset [21].”
MethodNonuniform fast fourier transforms using min-max interpolation
Fessler, J. A., & Sutton, B. P. (2003) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2002.807005 · Cited by 1,337
Ollinger, J. M., & Fessler, J. A. (1997) · IEEE Signal Processing Magazine · doi:10.1109/79.560323 · Cited by 1,167
Nonlocal Transform-Domain Filter for Volumetric Data Denoising and Reconstruction
Maggioni, M., Katkovnik, V., Egiazarian, K., & Foi, A. (2013) · IEEE Transactions on Image Processing · doi:10.1109/tip.2012.2210725 · Cited by 1,002
A Statistical Model for Positron Emission Tomography
Vardi, Y., Shepp, L. A., & Kaufman, L. (1985) · Journal of the American Statistical Association · doi:10.1080/01621459.1985.10477119 · Cited by 863
Self-citationFast Alternating Direction Optimization Methods
Goldstein, T., O'Donoghue, B., Setzer, S., & Baraniuk, R. (2014) · SIAM Journal on Imaging Sciences · doi:10.1137/120896219 · Cited by 785
Three-Dimensional X-Ray Microtomography
Flannery, B. P., Deckman, H. W., Roberge, W. G., & D'Amico, K. L. (1987) · Science · doi:10.1126/science.237.4821.1439 · Cited by 773
High-resolution image recovery from image-plane arrays, using convex projections
Stark, H., & Oskoui, P. (1989) · Journal of the Optical Society of America A · doi:10.1364/josaa.6.001715 · Cited by 734
Kalender, W. A. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/13/r03 · Cited by 689
A practical method for position-dependent Compton-scatter correction in single photon emission CT
Ogawa, K., Harata, Y., Ichihara, T., Kubo, A., & Hashimoto, S. (1991) · IEEE Transactions on Medical Imaging · doi:10.1109/42.97591 · Cited by 616
Skilling, J., & Gull, S. F. (1985) · Maximum-Entropy and Bayesian Methods in Inverse Problems · doi:10.1007/978-94-017-2221-6_5 · Cited by 561
Deep learning for tomographic image reconstruction
Wang, G., Ye, J. C., & De Man, B. (2020) · Nature Machine Intelligence · doi:10.1038/s42256-020-00273-z · Cited by 531
A local update strategy for iterative reconstruction from projections
Sauer, K., & Bouman, C. (1993) · IEEE Transactions on Signal Processing · doi:10.1109/78.193196 · Cited by 494
High resolution X-ray computed tomography: an emerging tool for small animal cancer research
Paulus, M. J., Gleason, S. S., Kennel, S. J., Hunsicker, P. R., & Johnson, D. K. (2000) · Neoplasia · doi:10.1038/sj.neo.7900069 · Cited by 490
Liu, T., Spincemaille, P., de Rochefort, L., Kressler, B., & Wang, Y. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21828 · Cited by 454
Regridding reconstruction algorithm for real-time tomographic imaging
Marone, F., & Stampanoni, M. (2012) · Journal of Synchrotron Radiation · doi:10.1107/s0909049512032864 · Cited by 441
Beylkin, G. (1987) · IEEE Transactions on Acoustics, Speech, and Signal Processing · doi:10.1109/tassp.1987.1165108 · Cited by 436
Digital reconstruction of multidimensional signals from their projections
Mersereau, R. M., & Oppenheim, A. V. (1974) · Proceedings of the IEEE · doi:10.1109/proc.1974.9625 · Cited by 435
An Improved Algorithm for Reprojecting Rays through Pixel Images
Joseph, P. M. (1982) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1982.4307572 · Cited by 375
Measuring techniques in gas–liquid and gas–liquid–solid reactors
Boyer, C., Duquenne, A.-M., & Wild, G. (2002) · Chemical Engineering Science · doi:10.1016/s0009-2509(02)00193-8 · Cited by 350
Density measurements using the Background Oriented Schlieren technique
Venkatakrishnan, L., & Meier, G. E. A. (2004) · Experiments in Fluids · doi:10.1007/s00348-004-0807-1 · Cited by 347
An outlook on x‐ray CT research and development
Wang, G., Yu, H., & De Man, B. (2008) · Medical Physics · doi:10.1118/1.2836950 · Cited by 341
Handbook of Mathematical Methods in Imaging
(2011) · Springer eBooks · doi:10.1007/978-0-387-92920-0 · Cited by 334
Pan, S., & Kak, A. (1983) · IEEE Transactions on Acoustics, Speech, and Signal Processing · doi:10.1109/tassp.1983.1164196 · Cited by 317
Instrumentation for treatment of cancer using proton and light-ion beams
Chu, W. T., Ludewigt, B. A., & Renner, T. R. (1993) · Review of Scientific Instruments · doi:10.1063/1.1143946 · Cited by 313
Neural network with unbounded activation functions is universal approximator
Sonoda, S., & Murata, N. (2017) · Applied and Computational Harmonic Analysis · doi:10.1016/j.acha.2015.12.005 · Cited by 303
“We next studied a gray-scale image Shepp-Logan phantom [42].”
MethodAlgebraic reconstruction in CT from limited views
Andersen, A. H. (1989) · IEEE Transactions on Medical Imaging · doi:10.1109/42.20361 · Cited by 278
Computerized tomography with X-ray, emission, and ultrasound sources
Kak, A. C. (1979) · Proceedings of the IEEE · doi:10.1109/proc.1979.11440 · Cited by 264
Multiscale X-ray tomography of cementitious materials: A review
Brisard, S., Serdar, M., & Monteiro, P. J. M. (2020) · Cement and Concrete Research · doi:10.1016/j.cemconres.2019.105824 · Cited by 260
Review of Terahertz Tomography Techniques
Guillet, J. P., Recur, B., Frederique, L., Bousquet, B., Canioni, L., Manek-Hönninger, I., Desbarats, P., & Mounaix, P. (2014) · Journal of Infrared, Millimeter, and Terahertz Waves · doi:10.1007/s10762-014-0057-0 · Cited by 254
Computerized Tomography: The New Medical X-Ray Technology
Shepp, L. A., & Kruskal, J. B. (1978) · The American Mathematical Monthly · doi:10.1080/00029890.1978.11994611 · Cited by 222
Self-citationZaidi, H., & Xu, X. G. (2007) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.9.060906.151934 · Cited by 219
Learned Initializations for Optimizing Coordinate-Based Neural Representations
Tancik, M., Mildenhall, B., Wang, T., Schmidt, D., Srinivasan, P. P., Barron, J. T., & Ng, R. (2021) · 2021 IEEE/CVF Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr46437.2021.00287 · Cited by 218
“T is a dataset of 2048 randomly generated 256× 256 pixel Shepp-Logan phantoms [31], where we provide 2D integral projections of a bundle of 256 parallel rays from a random angle as the measurement for each sampled signal T during meta-learning.”
MethodRealistic Analytical Phantoms for Parallel Magnetic Resonance Imaging
Guerquin-Kern, M., Lejeune, L., Pruessmann, K. P., & Unser, M. (2012) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2011.2174158 · Cited by 217
An Accelerated Linearized Alternating Direction Method of Multipliers
Ouyang, Y., Chen, Y., Lan, G., & Pasiliao, E. (2015) · SIAM Journal on Imaging Sciences · doi:10.1137/14095697x · Cited by 217
“For a given A, the measurements b are generated by b = Axtrue + ε, where xtrue is a 64 by 64 Shepp-Logan phantom [47] with intensities in [0, 1] (so n = 4096), and ε ≡ N(0, 0.”
MethodHong, I. K., Chung, S. T., Kim, H. K., Kim, Y. B., Son, Y. D., & Cho, Z. H. (2007) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2007.892644 · Cited by 207
“intersecting with each pixel instead of the areas [2].”
BackgroundOptimal Primal-Dual Methods for a Class of Saddle Point Problems
Chen, Y., Lan, G., & Ouyang, Y. (2014) · SIAM Journal on Optimization · doi:10.1137/130919362 · Cited by 197
“For a given A, the measurements are generated by b = Axtrue + ε, where xtrue is a 64 by 64 Shepp-Logan phantom [48] with intensities in [0, 1], and ε ≡ N(0, 10Ik) with k = 2048.”
MethodSlice-to-volume medical image registration: A survey
Ferrante, E., & Paragios, N. (2017) · Medical Image Analysis · doi:10.1016/j.media.2017.04.010 · Cited by 182
“(2010) or the well-known analytical Shepp-Logan phantom (Shepp and Logan, 1974) adopted by Kim et al.”
MethodMaximum likelihood, least squares, and penalized least squares for PET
Kaufman, L. (1993) · IEEE Transactions on Medical Imaging · doi:10.1109/42.232249 · Cited by 180
Towards quantitative 3D imaging of the osteocyte lacuno-canalicular network
Schneider, P., Meier, M., Wepf, R., & Müller, R. (2010) · Bone · doi:10.1016/j.bone.2010.07.026 · Cited by 172
“The projections are then used to reconstruct the specimen numerically on a computer, for the most part by performing conventional filtered backprojection as introduced by Shepp and Logan [144].”
MethodOnline resource for validation of brain segmentation methods
Shattuck, D. W., Prasad, G., Mirza, M., Narr, K. L., & Toga, A. W. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2008.10.066 · Cited by 166
“One of the early standards used in medical image validation was the Shepp–Logan phantom, which was developed for computed tomography (CT) (Shepp and Logan, 1974).”
MethodHigh-performance cone beam reconstruction using CUDA compatible GPUs
Okitsu, Y., Ino, F., & Hagihara, K. (2010) · Parallel Computing · doi:10.1016/j.parco.2010.01.004 · Cited by 70
“At the filtering stage, the algorithm applies the Shepp-Logan filter [32] to each projection Pn to obtain filtered projection Qn, where 1 ≤ n ≤ K.”
BackgroundMethodInfluentialTop-Level Design and Simulated Performance of the First Portable CT-MR Scanner
Peng, Y., Li, M., Grandinetti, J., Wang, G., & Jia, X. (2022) · IEEE Access · doi:10.1109/access.2022.3208278 · Cited by 4
“For CT simulation, the attenuation values are chosen in reference to the original specification of the 2D Shepp-Logan phantom [23].”
Method
Metadata
- Authors
- Shepp, L. A., & Logan, B. F.
- Venue
- IEEE Transactions on Nuclear Science
- Published
- 1974-06
- Volume
- 21
- Issue
- 3
- Pages
- 21-43
- ISSN
- 0018-9499 (ISSN-L)
- 1558-1578
- OpenAlex
- W2039472483
- Cited by
- 2,179
- References
- 0
- FWCI
- 24.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.