CoChat

A sensorized thumb for force closed-loop control of hand neuroprostheses

Carpaneto, J., Micera, S., Zaccone, F., Vecchi, F., Dario, P. · 2003 · IEEE Transactions on Neural Systems and Rehabilitation Engineering
Cited by 28

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

In this paper, we presented a sensorized thumb based on a matrix of piezoresistive force sensors, with an acquisition unit and a special wearing support. The sensor was calibrated and then the device was tested during different tasks simulating activities of daily living performed by seven able-bodied subjects. By means of these experiments, we verified that the device proposed can be used to extract force information during grasp. In fact, the device was able to provide useful force information in the 98% of the trials with a good repeatability during all the different conditions. Moreover, we evaluated the patterns obtained during the different grasping tasks. The palmar grasps were performed in a similar manner, whereas the lateral pinch and the spherical volar grip were more different. This device can provide force information with good performance and acceptability and it can be used for force closed-loop control of hand neuroprostheses.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tnsre.2003.819938

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Research works printed but not linked: 40

  1. Stein, 1992, Neural Prosthesis
  2. 10.1007/978-1-4471-0433-9 · DOI · Paper page
  3. 10.1007/BF02363440 · DOI
  4. 10.2106/00004623-198870010-00027 · DOI
  5. 10.1109/10.8669 · DOI · Paper page
  6. 10.1109/10.32109 · DOI · Paper page
  7. Nathan, 1990, Upper limb functions regained in quadriplegia: A hybrid computerized neuromuscular stimulation system, Arch. Phys. Med. Rehab., 71, 415
  8. 10.1038/sc.1992.24 · doi:10.1038/sc.1992.24
  9. 10.1109/86.681177 · DOI · Paper page
  10. 10.1109/86.681180 · DOI
  11. 10.1179/016164102101200311 · DOI · Paper page
  12. 10.1109/TBME.1980.326738 · DOI · Paper page
  13. 10.1109/10.4579 · DOI
  14. 10.1109/10.68205 · DOI
  15. 10.1109/10.237697 · DOI
  16. 10.1007/BF02513367 · DOI
  17. 10.1109/86.296346 · DOI · Paper page
  18. Hoffer, 1996, Neural signals for command control and feedback in functional neuromuscular stimulation: a review, J. Rehab. Res. Dev., 33, 145
  19. 10.1109/10.481986 · DOI · Paper page
  20. 10.1109/86.769412 · DOI · Paper page
  21. 10.1109/10.790501 · DOI · Paper page
  22. 10.1109/IEMBS.1998.744684 · DOI
  23. 10.3233/THC-1999-7602 · DOI
  24. 10.1109/51.897831 · DOI
  25. Bhadra, 2002, Implementation of an implantable joint-angle transducer, J. Rehabil. Res. Dev., 39, 411
  26. 10.1016/S0266-7681(98)80016-8 · DOI · Paper page
  27. 10.1016/S1350-4533(97)00048-9 · DOI
  28. 10.1046/j.1525-1594.2000.06569.x · DOI
  29. 10.1007/BF02347046 · DOI
  30. Memberg, 1997, Instrumented objects for quantitative evaluation of hand grasp, J Rehab. Res. Dev., 34, 82
  31. 10.1016/S0266-7681(98)80099-5 · doi:10.1016/s0266-7681(98)80099-5
  32. 10.1109/86.593280 · DOI · Paper page
  33. 10.1007/BF02347047 · DOI
  34. 10.1109/10.661263 · DOI
  35. Vecchi, A sensorized glove for applications in biomechanics and motor control, 190
  36. 10.1109/IROS.1995.525871 · DOI
  37. 10.1080/00140138508963153 · doi:10.1080/00140138508963153
  38. 10.3109/02844319509034334 · DOI · Paper page
  39. 10.1109/86.547927 · DOI
  40. Freschi, Force control during grasp using FES techniques: Preliminary results, 501

Cited by

Metadata

Authors
Carpaneto, J., Micera, S., Zaccone, F., Vecchi, F., & Dario, P.
Venue
IEEE Transactions on Neural Systems and Rehabilitation Engineering
Published
2003-12
Volume
11
Issue
4
Pages
346-353
ISSN
  • 1534-4320 (ISSN-L)
  • 1558-0210
OpenAlex
W2110457428
Cited by
28
References
5
FWCI
0.77
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.