Potential errors in pulse oximetry III: Effects of interference, dyes, dyshaemoglobins and other pigments*
The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
Summary: Electrosurgery, patient motion and some types of lighting can cause errors in saturation readout; it is recommended that probes should be shielded from ambient lighting. Intravenous dyes can introduce gross but transient errors, which may also be present in in vitro measurements. Carboxyhaemoglobin causes overestimation of fractional saturation by an amount less than, but possibly close to, the percent of carboxyhaemoglobin present. Methaemoglobin causes the pulse oximeter readout to tend towards 85%. Fetal haemoglobin and bilirubin introduce no significant error, although they may interfere with in vitro measurements. Skin pigmentation can result in a slight decrease in accuracy. Nail polish may cause up to 6% underestimation of saturation; it is recommended that probes should be mounted sideways on fingers with nail polish or long nails. Adhesive tape or a vinyl glove across the probe has no demonstrable effect on accuracy. A blood sample should be analysed by a multiwavelength in vitro oximeter when an erroneous pulse oximeter reading is suspected, although errors may be introduced in the in vitro reading by fetal haemoglobin, bilirubin and intravenous dyes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tremper, K. K., & Barker, S. J. (1989) · Anesthesiology · doi:10.1097/00000542-198901000-00019 · Cited by 435
The Effect of Carbon Monoxide Inhalation on Pulse Oximetry and Transcutaneous Po 2
Barker, S. J., & Tremper, K. K. (1987) · Anesthesiology · doi:10.1097/00000542-198705000-00014 · Cited by 281
Principles of Pulse Oximetry: Theoretical and Practical Considerations
Alexander, C. M., Teller, L. E., & Gross, J. B. (1989) · Anesthesia & Analgesia · doi:10.1213/00000539-198903000-00035 · Cited by 230
Potential errors in pulse oximetry: II. Effects of changes in saturation and signal quality*
WEBB, R. K., RALSTON, A. C., & RUNCIMAN, W. B. (1991) · Anaesthesia · doi:10.1111/j.1365-2044.1991.tb09411.x · Cited by 213
Self-citationEffects of Intravenously Administered Dyes on Pulse Oximetry Readings
SCHELLER, M. S., UNGER, R. J., & KELNER, M. J. (1986) · Anesthesiology · doi:10.1097/00000542-198611000-00023 · Cited by 194
Principles of pulse oximetry: theoretical and practical considerations.
Alexander, C. M., Teller, L. E., & Gross, J. B. (1989) · PubMed · Cited by 175
The Effect of Nail Polish on Pulse Oximetry
Cot??, C. J., Goldstein, E. A., Fuchsman, W. H., & Hoaglin, D. C. (1988) · Anesthesia & Analgesia · doi:10.1213/00000539-198807000-00013 · Cited by 172
Potential errors in pulse oximetry: I. Pulse oximeter evaluation*
RALSTON, A. C., WEBB, R. K., & RUNCIMAN, W. B. (1991) · Anaesthesia · doi:10.1111/j.1365-2044.1991.tb09410.x · Cited by 166
Self-citationRies, A. L., Prewitt, L. M., & Johnson, J. J. (1989) · Chest · doi:10.1378/chest.96.2.287 · Cited by 145
Taylor, M. B., & WHITWAM, J. G. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12922.x · Cited by 123
Pulse Oximetry: Uses and Limitations
DeMeulenaere, S. (2007) · The Journal for Nurse Practitioners · doi:10.1016/j.nurpra.2007.02.021 · Cited by 112
A comparison of the performance of 20 pulse oximeters under conditions of poor perfusion
Clayton, D. G., Webb, R. K., Ralston, A., Duthie, D. J. R., & Runciman, W. B. (1991) · Anaesthesia · doi:10.1111/j.1365-2044.1991.tb09303.x · Cited by 112
Self-citationPulse Oximetry: Applications and Limitations
Barker, S. J., & Tremper, K. K. (1987) · International Anesthesiology Clinics · doi:10.1097/00004311-198702530-00010 · Cited by 105
CLAYTON, D. G., WEBB, R. K., RALSTON, A. C., DUTHIE, D., & RUNCIMAN, W. B. (1991) · Anaesthesia · doi:10.1111/j.1365-2044.1991.tb11492.x · Cited by 90
Self-citationde Zwart, A. E. S., Buursma, A., Oeseburg, B., & Zijlstra, W. G. (1981) · Clinical Chemistry · doi:10.1093/clinchem/27.11.1903 · Cited by 77
Pulse Oximetry in Very Low Birth Weight Infants With Acute and Chronic Lung Disease
Ramanathan, R., Durand, M., & Larrazabal, C. (1987) · PEDIATRICS · doi:10.1542/peds.79.4.612 · Cited by 75
Ambient Light Affects Pulse Oximeters
Hanowell, L. H., Eisele, J. H., & DOWNS, D. (1987) · Anesthesiology · doi:10.1097/00000542-198711000-00057 · Cited by 69
Pulse Oximetry in Methemoglobinemia
Watcha, M. F., Connor, M. T., & Hing, A. V. (1989) · Archives of Pediatrics and Adolescent Medicine · doi:10.1001/archpedi.1989.02150190095030 · Cited by 69
Hyperbilirubinemia Does Not Interfere with Hemoglobin Saturation Measured by Pulse Oximetry
Veyckemans, F., Baele, P., Guillaume, J., Willems, E., Robert, A. R., & Clerbaux, T. (1989) · Anesthesiology · doi:10.1097/00000542-198901000-00022 · Cited by 66
Benzocaine-Induced Methemoglobinemia in an Adult: Accuracy of Pulse Oximetry with Methemoglobinemia
Anderson, S. T., Hajduczek, J., & Barker, S. J. (1988) · Anesthesia & Analgesia · doi:10.1213/00000539-198811000-00015 · Cited by 64
Mendelson, Y., & Kent, J. C. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.30810 · Cited by 60
GABRIELCZYK, M. R., & BUIST, R. J. (1988) · Anaesthesia · doi:10.1111/j.1365-2044.1988.tb09025.x · Cited by 59
Falsely Normal Saturation Reading with the Pulse Oximeter
Costarino, A. T., Davis, D. A., & Keon, T. P. (1987) · Anesthesiology · doi:10.1097/00000542-198711000-00041 · Cited by 52
A clinical evaluation of the accuracy of the Nellcor N-100 and Ohmeda 3700 pulse oximeters
Cecil, W. T., Thorpe, K. J., Fibuch, E. E., & Tuohy, G. F. (1988) · Journal of Clinical Monitoring · doi:10.1007/bf01618105 · Cited by 51
Separation of Bilirubin from Hemoglobin by Recording Derivative Spectrophotometry
Amazon, K., Soloni, F. G., & Rywlin, A. M. (1981) · American Journal of Clinical Pathology · doi:10.1093/ajcp/75.4.519 · Cited by 33
EFFECT OF METHYLENE BLUE ON THE ABSORBANCE OF SOLUTIONS OF HAEMOGLOBIN
GORMAN, E. S., & SHNIDER, M. R. (1988) · British Journal of Anaesthesia · doi:10.1093/bja/60.4.439 · Cited by 22
Cited by
Methemoglobinemia: Etiology, Pharmacology, and Clinical Management
Wright, R. O., Lewander, W. J., & Woolf, A. D. (1999) · Annals of Emergency Medicine · doi:10.1016/s0196-0644(99)70167-8 · Cited by 856
Effects of skin pigmentation on pulse oximeter accuracy at low saturation
Bickler, P. E., Feiner, J. R., & Severinghaus, J. W. (2005) · Anesthesiology · doi:10.1097/00000542-200504000-00004 · Cited by 427
“%) in black patients.4–7 Model simulations of errors due to various pigments were reviewed by Ralston et al.8 Cote et al.9 reported that nail polish and ink on skin surface can cause errors, a finding confirmed anecdotally by others from fingerprinting ink,10 henna,11 and meconium.12 Intravenously injected dyes cause…”
McFadden, E. R. (2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200208-902so · Cited by 317
The Scoring of Respiratory Events in Sleep: Reliability and Validity
Redline, S., Budhiraja, R., Kapur, V., Marcus, C. L., Mateika, J. H., Mehra, R., Parthasarthy, S., Somers, V. K., Strohl, K. P., Gozal, D., et al. (2007) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.26818 · Cited by 305
Meta-analysis of arterial oxygen saturation monitoring by pulse oximetry in adults
Jensen, L. A., Onyskiw, J. E., & Prasad, N. G. N. (1998) · Heart & Lung · doi:10.1016/s0147-9563(98)90086-3 · Cited by 243
Metadata
- Authors
- RALSTON, A. C., WEBB, R. K., & RUNCIMAN, W. B.
- Venue
- Anaesthesia
- Publisher
- Wiley
- Published
- 1991-04
- Volume
- 46
- Issue
- 4
- Pages
- 291-295
- ISSN
- 0003-2409 (ISSN-L)
- 1365-2044
- OpenAlex
- W2002790965
- Cited by
- 192
- References
- 26
- FWCI
- 6.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.