The DOI matches its Crossref record; 85 of the 85 references it cites were found in a registry or an index.
Continuous glucose monitoring and closed‐loop systems
Abstract
Background The last two decades have witnessed unprecedented technological progress in the development of continuous glucose sensors, resulting in the first generation of commercial glucose monitors. This has fuelled the development of prototypes of a closed‐loop system based on the combination of a continuous monitor, a control algorithm, and an insulin pump. Method A review of electromechanical closed‐loop approaches is presented. This is followed by a review of existing prototypes and associated glucose sensors. A literature review was undertaken from 1960 to 2004. Results Two main approaches exist. The extracorporeal s.c.–s.c. approach employs subcutaneous glucose monitoring and subcutaneous insulin delivery. The implantable i.v.–i.p. approach adopts intravenous sampling and intraperitoneal insulin delivery. Feasibility of both solutions has been demonstrated in small‐scale laboratory studies using either the classical proportional–integral–derivative controller or a model predictive controller. Performance in the home setting has yet to be demonstrated. Conclusions The glucose monitor remains the main limiting factor in the development of a commercially viable closed‐loop system, as presently available monitors fail to demonstrate satisfactory characteristics in terms of reliability and/or accuracy. Regulatory issues are the second limiting factor. Closed‐loop systems are likely to be used first by health‐care professionals in controlled environments such as intensive care units.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intensive insulin therapy in critically ill patients.
Van den Berghe, G., Wouters, P., Weekers, F., Verwaest, C., Bruyninckx, F., Schetz, M., Vlasselaers, D., Ferdinande, P., Lauwers, P., & Bouillon, R. (2001) · New England Journal of Medicine · doi:10.1056/nejmoa011300 · Cited by 9,977
Evaluating clinical accuracy of systems for self-monitoring of blood glucose
Clarke, W. L., Cox, D., Gonder-Frederick, L. A., Carter, W., & Pohl, S. L. (1987) · Diabetes Care · doi:10.2337/diacare.10.5.622 · Cited by 1,435
Nonlinear model predictive control of glucose concentration in subjects with type 1 diabetes
Hovorka, R., Canonico, V., Chassin, L. J., Haueter, U., Massi-Benedetti, M., Federici, M. O., Pieber, T. R., Schaller, H. C., Schaupp, L., Vering, T., et al. (2004) · Physiological Measurement · doi:10.1088/0967-3334/25/4/010 · Cited by 1,274
Self-citationCamacho, E. F., & Bordons, C. (1999) · Advanced Textbooks in Control and Signal Processing · doi:10.1007/978-1-4471-3398-8 · Cited by 1,151
Mean Amplitude of Glycemic Excursions, a Measure of Diabetic Instability
Service, F. J., Molnar, G. D., Rosevear, J. W., Ackerman, E., Gatewood, L. C., & Taylor, W. F. (1970) · Diabetes · doi:10.2337/diab.19.9.644 · Cited by 1,039
NAUCK, M. A., HOMBERGER, E., SIEGEL, E. G., ALLEN, R. C., EATON, R. P., EBERT, R., & CREUTZFELDT, W. (1986) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem-63-2-492 · Cited by 874
Malmberg, K., Norhammar, A., Wedel, H., & Rydén, L. (1999) · Circulation · doi:10.1161/01.cir.99.20.2626 · Cited by 847
Continuous subcutaneous insulin infusion: an approach to achieving normoglycaemia.
Pickup, J. C., Keen, H., Parsons, J. A., & Alberti, K. G. (1978) · BMJ · doi:10.1136/bmj.1.6107.204 · Cited by 563
A model-based algorithm for blood glucose control in Type I diabetic patients
Parker, R. S., Doyle, F. J., & Peppas, N. A. (1999) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.740877 · Cited by 500
Implementation of a Safe and Effective Insulin Infusion Protocol in a Medical Intensive Care Unit
Goldberg, P. A., Siegel, M. D., Sherwin, R. S., Halickman, J. I., Lee, M., Bailey, V. A., Lee, S. L., Dziura, J. D., & Inzucchi, S. E. (2004) · Diabetes Care · doi:10.2337/diacare.27.2.461 · Cited by 483
Continuous Subcutaneous Insulin Infusion at 25 Years
Pickup, J., & Keen, H. (2002) · Diabetes Care · doi:10.2337/diacare.25.3.593 · Cited by 397
A threshold distribution hypothesis for packet storage of insulin and its mathematical modeling
Grodsky, G. M. (1972) · Journal of Clinical Investigation · doi:10.1172/jci107011 · Cited by 395
Partitioning glucose distribution/transport, disposal, and endogenous production during IVGTT
Hovorka, R., Shojaee-Moradie, F., Carroll, P. V., Chassin, L. J., Gowrie, I. J., Jackson, N. C., Tudor, R. S., Umpleby, A. M., & Jones, R. H. (2002) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.00304.2001 · Cited by 393
Self-citationThe M‐Value, an Index of Blood‐sugar Control in Diabetics
SCHLICHTKRULL, J., MUNCK, O., & JERSILD, M. (1965) · Acta Medica Scandinavica · doi:10.1111/j.0954-6820.1965.tb01810.x · Cited by 385
An Artificial Endocrine Pancreas
Albisser, A. M., Leibel, B. S., Ewart, T. G., Davidovac, Z., Botz, C. K., & Zingg, W. (1974) · Diabetes · doi:10.2337/diab.23.5.389 · Cited by 379
Rebrin, K., Steil, G. M., van Antwerp, W. P., & Mastrototaro, J. J. (1999) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1999.277.3.e561 · Cited by 366
WEARABLE ARTIFICIAL ENDOCRINE PANCREAS WITH NEEDLE-TYPE GLUCOSE SENSOR
Shichiri, M., Yamasaki, Y., Kawamori, R., Hakui, N., & Abe, H. (1982) · The Lancet · doi:10.1016/s0140-6736(82)92788-x · Cited by 314
Closed-loop insulin delivery—the path to physiological glucose control
Steil, G. (2004) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2003.08.011 · Cited by 313
Performance Evaluation of the MiniMed® Continuous Glucose Monitoring System During Patient Home Use
Gross, T. M., Bode, B. W., Einhorn, D., Kayne, D. M., Reed, J. H., White, N. H., & Mastrototaro, J. J. (2000) · Diabetes Technology & Therapeutics · doi:10.1089/152091500316737 · Cited by 303
Sensors for glucose monitoring: technical and clinical aspects
Koschinsky, T., & Heinemann, L. (2001) · Diabetes/Metabolism Research and Reviews · doi:10.1002/dmrr.188 · Cited by 288
Clinical Control of Diabetes by the Artificial Pancreas
Albisser, A. M., Leibel, B. S., Ewart, T. G., Davidovac, Z., Botz, C. K., Zingg, W., Schipper, H., & Gander, R. (1974) · Diabetes · doi:10.2337/diab.23.5.397 · Cited by 272
Pfeiffer, E., Thum, C., & Clemens, A. (1974) · Hormone and Metabolic Research · doi:10.1055/s-0028-1093841 · Cited by 238
The intravenous route to blood glucose control
Parker, R. S., Doyle, F. J., & Peppas, N. A. (2001) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.897829 · Cited by 236
Progress in artificial organs, 1985
Nosé, Y., Kjellstrand, C. M., & Ivanovich, P. (1986) · Cited by 229
Ludvigsson, J., & Hanas, R. (2003) · Pediatrics · doi:10.1542/peds.111.5.933 · Cited by 228
Computer Simulation of Plasma Insulin and Glucose Dynamics After Subcutaneous Insulin Injection
Berger, M., & Rodbard, D. (1989) · Diabetes Care · doi:10.2337/diacare.12.10.725 · Cited by 223
The development of Biostator, a Glucose Controlled Insulin Infusion System (GCIIS).
Clemens, A. H., Chang, P. H., & Myers, R. W. (1977) · PubMed · Cited by 191
Bode, B., Gross, K., Rikalo, N., Schwartz, S., Wahl, T., Page, C., Gross, T., & Mastrototaro, J. (2004) · Diabetes Technology & Therapeutics · doi:10.1089/152091504773731285 · Cited by 190
An integrated mathematical model of the dynamics of blood glucose and its hormonal control
Cobelli, C., Federspil, G., Pacini, G., Salvan, A., & Scandellari, C. (1982) · Mathematical Biosciences · doi:10.1016/0025-5564(82)90050-5 · Cited by 182
First-phase insulin secretion: does it exist in real life? Considerations on shape and function
Caumo, A., & Luzi, L. (2004) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.00139.2003 · Cited by 174
Implantable closed-loop glucose-sensing and insulin delivery: the future for insulin pump therapy
Renard, É. (2002) · Current Opinion in Pharmacology · doi:10.1016/s1471-4892(02)00216-3 · Cited by 170
Closing the Loop: The Adicol Experience
Hovorka, R., Chassin, L. J., Wilinska, M. E., Canonico, V., Akwi, J. A., Federici, M. O., Massi‐Benedetti, M., Hutzli, I., Zaugg, C., Kaufmann, H., et al. (2004) · Diabetes Technology & Therapeutics · doi:10.1089/152091504774197990 · Cited by 162
Self-citationSachedina, N., & Pickup, J. C. (2003) · Diabetic Medicine · doi:10.1046/j.1464-5491.2003.01037.x · Cited by 159
“J”-Index. A New Proposition of the Assessment of Current Glucose Control in Diabetic Patients
Wójcicki, J. (1995) · Hormone and Metabolic Research · doi:10.1055/s-2007-979906 · Cited by 159
A Direct Comparison of Insulin Aspart and Insulin Lispro in Patients With Type 1 Diabetes
Plank, J., Wutte, A., Brunner, G., Siebenhofer, A., Semlitsch, B., Sommer, R., Hirschberger, S., & Pieber, T. R. (2002) · Diabetes Care · doi:10.2337/diacare.25.11.2053 · Cited by 158
Experience with the Continuous Glucose Monitoring System® in a Medical Intensive Care Unit
Goldberg, P. A., Siegel, M. D., Russell, R. R., Sherwin, R. S., Halickman, J. I., Cooper, D. A., Dziura, J. D., & Inzucchi, S. E. (2004) · Diabetes Technology & Therapeutics · doi:10.1089/152091504774198034 · Cited by 158
Recent Advances in the Okamoto Model
Okamoto, H., & Takasawa, S. (2002) · Diabetes · doi:10.2337/diabetes.51.2007.s462 · Cited by 150
McGowan, K., Thomas, W. T. B., & Moran, A. (2002) · Diabetes Care · doi:10.2337/diacare.25.9.1499 · Cited by 148
Chee, F., Fernando, T. L., & van Heerden, P. V. (2003) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2003.808509 · Cited by 142
Neural predictive controller for insulin delivery using the subcutaneous route
Trajanoski, Z., & Wach, P. (1998) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.709556 · Cited by 136
Guerci, B., Floriot, M., Böhme, P., Durain, D., Bénichou, M., Jellimann, S., & Drouin, P. (2003) · Diabetes Care · doi:10.2337/diacare.26.3.582 · Cited by 134
Reproducibility of Glucose Measurements Using the Glucose Sensor
Metzger, M., Leibowitz, G., Wainstein, J., Gläser, B., & Raz, I. (2002) · Diabetes Care · doi:10.2337/diacare.25.7.1185 · Cited by 134
An Insulin Infusion Protocol in Critically Ill Cardiothoracic Surgery Patients
Zimmerman, C. R., Mlynarek, M. E., Jordan, J., Rajda, C. A., & Horst, H. M. (2004) · Annals of Pharmacotherapy · doi:10.1345/aph.1e018 · Cited by 128
*The Diabetes Research in Children Network (DirecNet) Study Group (2004) · Diabetes Care · doi:10.2337/diacare.27.3.722 · Cited by 117
Kinetic Modeling of the Glucoregulatory System to Improve Insulin Therapy
Salzsieder, E., Albrecht, G., Fischer, U., & Freyse, E. (1985) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1985.325500 · Cited by 101
Feedback control dynamics for glucose controlled insulin infusion system.
Clemens, A. H. (1979) · PubMed · Cited by 95
AUTOMATION CONTROL OF BLOOD SUGAR. I. A SERVOMECHANISM FOR GLUCOSE MONITORING AND CONTROL.
Kadish, A. H. (1964) · PubMed · Cited by 94
Modeling β -Cell Insulin Secretion - Implications for Closed-Loop Glucose Homeostasis
Steil, G. M., Rebrin, K., Janowski, R., Darwin, C. H., & Saad, M. F. (2003) · Diabetes Technology & Therapeutics · doi:10.1089/152091503322640999 · Cited by 88
Schaepelynck-Belicar, P., Vague, P., Simonin, G., & Lassmann-Vague, V. (2003) · Diabetes & Metabolism · doi:10.1016/s1262-3636(07)70076-9 · Cited by 87
Shimoda, S., Nishida, K., Sakakida, M., Konno, Y., Ichinose, K., Uehara, M., Nowak, T., & Shichiri, M. (1997) · PubMed · Cited by 85
Hashiguchi, Y., Sakakida, M., Nishida, K., Uemura, T., Kajiwara, K., & Shichiri, M. (1994) · Diabetes Care · doi:10.2337/diacare.17.5.387 · Cited by 81
Schiaffini, R., Ciampalini, P., Fierabracci, A., Spera, S., Borrelli, P., Bottazzo, G. F., & Crinò, A. (2002) · Diabetes/Metabolism Research and Reviews · doi:10.1002/dmrr.309 · Cited by 79
Marliss, E. B., Murray, F. T., Stokes, E. F., Zinman, B., NAKHOODA, A. F., Denoga, A., LEIBEL, B. S., & Albisser, A. M. (1977) · Diabetes · doi:10.2337/diab.26.7.663 · Cited by 76
Physiological augmentation of amino acid-induced insulin secretion by GIP and GLP-I but not by CCK-8
Fieseler, P., Bridenbaugh, S. A., Nustede, R., Martell, J., Ørskov, C., Holst, J. J., & Nauck, M. A. (1995) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1995.268.5.e949 · Cited by 76
Direct access to interstitial fluid in adipose tissue in humans by use of open-flow microperfusion
Schaupp, L., Ellmerer, M., Brunner, G. A., Wutte, A., Sendlhofer, G., Trajanoski, Z., Skrabal, F., Pieber, T. R., & Wach, P. (1999) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1999.276.2.e401 · Cited by 75
In vivo evaluation of an electroenzymatic glucose sensor implanted in subcutaneous tissue
Johnson, K. W., Mastrototaro, J. J., Howey, D. C., Brunelle, R. L., Burden-Brady, P. L., Bryan, N. A., Andrew, C. C., Rowe, H., Allen, D. J., Noffke, B. W., et al. (1992) · Biosensors and Bioelectronics · doi:10.1016/0956-5663(92)85053-d · Cited by 73
Understanding Error Grid Analysis
Cox, D. J., Gonder-Frederick, L. A., Kovatchev, B. P., Julian, D. M., & Clarke, W. L. (1997) · Diabetes Care · doi:10.2337/diacare.20.6.911 · Cited by 73
Accuracy of the continuous glucose monitoring system in inpatient and outpatient conditions
Djakouré-Platonoff, C., Radermercker, R., Reach, G., Slama, G., & Jl, S. (2003) · Diabetes & Metabolism · doi:10.1016/s1262-3636(07)70023-x · Cited by 69
Heinemann, L. (2003) · Diabetes Technology & Therapeutics · doi:10.1089/152091503322250578 · Cited by 68
Gin, H., Renard, É., Melki, V., et al. (2003) · Diabetes & Metabolism · doi:10.1016/s1262-3636(07)70075-7 · Cited by 66
Shichiri, M., Sakakida, M., Nishida, K., & Shimoda, S. (1998) · Artificial Organs · doi:10.1046/j.1525-1594.1998.06043.x · Cited by 66
Comparison of Algorithms for the Closed-Loop Control of Blood Glucose Using the Artificial Beta Cell
Broekhuyse, H. M., Nelson, H. D., Zinman, B., & Albisser, A. M. (1981) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1981.324661 · Cited by 65
CONTINUOUS IN VIVO DETERMINATION OF BLOOD GLUCOSE IN HUMAN SUBJECTS
Weller, C., Linder, M., Macaulay, A. I., Ferrari, A., & Kessler, G. (1960) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1960.tb23229.x · Cited by 64
Steil, G. M., Hwu, C.-M., Janowski, R., Hariri, F., Jinagouda, S. D., Darwin, C. H., Tadros, S. S., Rebrin, K., & Saad, M. F. (2004) · Diabetes · doi:10.2337/diabetes.53.5.1201 · Cited by 64
Control of Blood Glucose in Diabetics using an Artificial Pancreas*
Kraegen, E. W., Campbell, L. V., Chia, Y. O., Meier, H., & Lazarus, L. (1977) · Australian and New Zealand Journal of Medicine · doi:10.1111/j.1445-5994.1977.tb03687.x · Cited by 63
Physiological consequences of phasic insulin release in the normal animal
Cherrington, A. D., Sindelar, D., Edgerton, D., Steiner, K., & McGuinness, O. P. (2002) · Diabetes · doi:10.2337/diabetes.51.2007.s103 · Cited by 63
Pratipanawatr, T., Cusi, K., Ngo, P., Pratipanawatr, W., Mandarino, L. J., & DeFronzo, R. A. (2002) · Diabetes · doi:10.2337/diabetes.51.2.462 · Cited by 61
Schaller, H. C., Schaupp, L., Bodenlenz, M., Wilinska, M. E., Chassin, L. J., Wach, P., Vering, T., Hovorka, R., & Pieber, T. R. (2006) · Diabetic Medicine · doi:10.1111/j.1464-5491.2006.01695.x · Cited by 56
Self-citationGlucose sensors: toward closed loop insulin delivery
Chia, C. W., & Saudek, C. D. (2004) · Endocrinology and Metabolism Clinics of North America · doi:10.1016/j.ecl.2003.12.001 · Cited by 50
Estimation-based model predictive control of blood glucose in type I diabetics: a simulation study
Lynch, S. M., & Bequette, B. W. (2002) · IEEE Annual Northeast Bioengineering Conference (NEBEC) · doi:10.1109/nebc.2001.924729 · Cited by 47
Recording of subcutaneous glucose dynamics by a viscometric affinity sensor
Beyer, U., Schäfer, D., Thomas, A., Aulich, H. A., Haueter, U., Reihl, B., & EHWALD, R. (2001) · Diabetologia · doi:10.1007/s001250051637 · Cited by 46
External and implantable insulin pumps: current place in the treatment of diabetes
Selam, J. L. (2001) · Experimental and Clinical Endocrinology & Diabetes · doi:10.1055/s-2001-18592 · Cited by 45
THEDIABETESRESEARCHINCHILDREN (2004) · The Journal of Pediatrics · doi:10.1016/j.jpeds.2004.03.042 · Cited by 41
The SCGM1 System: Subcutaneous Continuous Glucose Monitoring Based on Microdialysis Technique
Schoemaker, M., Andreis, E., Röper, J., Kotulla, R., Lodwig, V., Obermaier, K., Stephan, P., Reuschling, W., Rutschmann, M., Schwaninger, R., et al. (2003) · Diabetes Technology & Therapeutics · doi:10.1089/152091503322250613 · Cited by 41
An Improved Control Algorithm for an Artificial B-Cell
Botz, C. K. (1976) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1976.324639 · Cited by 38
Goriya, Y., Kawamori, R., Shichiri, M., & Abe, H. (1979) · PubMed · Cited by 33
Recent advances in continuous glucose monitoring
Freckmann, G., Kalatz, B., Pfeiffer, B., Hoss, U., & Haug, C. (2001) · Experimental and Clinical Endocrinology & Diabetes · doi:10.1055/s-2001-18594 · Cited by 29
Glycemic Control with Closed-Loop Intraperitoneal Insulin in Type I Diabetes
Leblanc, H., Chauvet, D., Lombrail, P., & Robert, J. J. (1986) · Diabetes Care · doi:10.2337/diacare.9.2.124 · Cited by 23
Bélicar, P., Vague, P., & Lassmann-Vague, V. (2003) · Diabetes & Metabolism · doi:10.1016/s1262-3636(07)70045-9 · Cited by 22
Hoss, U., Kalatz, B., Gessler, R., Pfleiderer, H.-J., Andreis, E., Rutschmann, M., Rinne, H., Schoemaker, M., Haug, C., & Fussgaenger, R. D. (2001) · Diabetes Technology & Therapeutics · doi:10.1089/152091501300209615 · Cited by 21
Does continuous glucose monitoring have clinical utility in contemporary management of diabetes?
Cameron, F. J., & Ambler, G. R. (2004) · Journal of Paediatrics and Child Health · doi:10.1111/j.1440-1754.2004.00307.x · Cited by 19
Mastrototaro, J. J., & Gross, T. M. (2003) · Diabetes Care · doi:10.2337/diacare.26.1.256 · Cited by 17
Grading System to Assess Clinical Performance of Closed-Loop Glucose Control
Chassin, L. J., Wilinska, M. E., & Hovorka, R. (2005) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2005.7.72 · Cited by 16
Self-citation[From external to implantable insulin pump, can we close the loop?].
Renard, É., Costalat, G., & Bringer, J. (2002) · PubMed · Cited by 14
Artificial endocrine pancreas : development and clinical applications
七里, 元. (2000) · Medical Entomology and Zoology · Cited by 4
Research works printed but not linked: 23
- 10.2337/diabetes.26.7.663 · DOI
- Panteleon AE, 2004, A novel approach for closed loop control of meal‐induced carbohydrate uptake, Diabetes Technol Ther, 6, 265
- 10.1089/152091503322527049 · doi:10.1089/152091503322527049
- 10.1147/sj.314.0635 · doi:10.1147/sj.314.0635
- Shimoda S, 2001, Development of closed‐loop intraperitoneal insulin infusion algorithm for a implantable artificial endocrine pancreas, Diabetes, 50, A3
- Schaller HC, 2002, MPC algorithm controls blood glucose in patients with type 1 diabetes mellitus under fasting conditions using the IV‐SC route, Diabetes Technol Ther, 4, 234
- Schaller HC, 2002, Feasibility of the SC‐SC route for an extracorporeal artificial pancreas, Diabetes, 51, 462
- Schaller HC, 2003, DM under daily life conditions, Diabetes Metab, 29, A2225
- Vering T., 2004, Minimally invasive control loop system for SC‐SC control on patients with type 1 diabetes, Diabetes Technol Ther, 6, 278
- Mastrototaro J., 1999, The MiniMed continuous glucose monitoring system (CGMS), J Pediatr Endocr Met, 12, 751
- Louis Sylvestre J., 1987, The cephalis phase of insulin secretion, Diabetes Metab, 13, 63
- Steil GM, 2002, Tuning closed‐loop insulin delivery based on known daily insulin requirements, Diabetes, 51, 510
- Steil GM, 2004, Continuous automated insulin delivery based on subcutaneous glucose sensing and an external insulin pump, Diabetes, 53, A2
- Renard E, 2003, Sustained safety and accuracy of central IV glucose sensors connected to implanted insulin pumps and short‐term closed‐loop trials in diabetic patients, Diabetes, 52, A36
- Shah R, 2001, Automatic feedback control of plasma glucose levels in diabetic canines, Diabetes, 50, A3
- Renard E, 2004, Efficacy of closed loop control of blood glucose based on an implantable i.v. sensor and intraperitoneal pump, Diabetes, 53, A114
- Galley P, 2004, Use of subcutaneous glucose measurements to drive real‐time algorithm‐directed insulin infusion recommendations, Diabetes Technol Ther, 6, 245
- Thukral A, 2004, Conversion of an empirical closed loop algorithm into the MPC framework, Diabetes Technol Ther, 6, 275
- Kalatz B, 1999, Development of algorithms for feedback‐controlled subcutaneous insulin infusion with insulin lispro, Acta Diabetol, 36, 215
- KalatzB.Algorithmen zur Glucosegesteuerten Insulininfusion bei Diabetes Mellitus—Entwicklung und Experimentelle Untersuchung.Medical Dissertation.Ulm Germany: University of Ulm 1999.
- Goldberg PA, 2004, Implementation of a safe, effective insulin infusion protocol (IIP) in the cardiothoracic (CT) intensive care unit (ICU), Diabetes, 53, A109
- Canonico V, 2002, Evaluation of a feedback model based on simulated interstitial glucose for continuous insulin infusion, Diabetologia, 45, 995
- 10.1089/152091504773731285 · DOI · Paper page
Cited by
Clinical Practice Guidelines for Multiple Endocrine Neoplasia Type 1 (MEN1)
Thakker, R. V., Newey, P. J., Walls, G. V., Bilezikian, J., Dralle, H., Ebeling, P. R., Melmed, S., Sakurai, A., Tonelli, F., & Brandi, M. L. (2012) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2012-1230 · Cited by 1,477
Cryer, P. E., Axelrod, L., Grossman, A. B., Heller, S. R., Montori, V. M., Seaquist, E. R., & Service, F. J. (2009) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2008-1410 · Cited by 1,277
Francis, G. L., Waguespack, S. G., Bauer, A. J., Angelos, P., Benvenga, S., Cerutti, J. M., Dinauer, C. A., Hamilton, J., Hay, I. D., Luster, M., et al. (2015) · Thyroid · doi:10.1089/thy.2014.0460 · Cited by 1,238
Cryer, P. E., Davis, S. N., & Shamoon, H. (2003) · Diabetes Care · doi:10.2337/diacare.26.6.1902 · Cited by 1,160
Andreu-Perez, J., Poon, C. C. Y., Merrifield, R. D., Wong, S. T. C., & Yang, G.-Z. (2015) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2015.2450362 · Cited by 670
Metadata
- Authors
- Hovorka, R.
- Venue
- Diabetic Medicine
- Publisher
- Wiley
- Published
- 2005-06-28
- Volume
- 23
- Issue
- 1
- Pages
- 1-12
- ISSN
- 0742-3071 (ISSN-L)
- 1464-5491
- OpenAlex
- W2147750301
- Cited by
- 443
- References
- 85
- FWCI
- 14.96
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.