Visible-light optical coherence tomography: a review
Open accessThe DOI matches its Crossref record; 60 of the 60 references it cites were found in a registry or an index.
Abstract
Visible-light optical coherence tomography (vis-OCT) is an emerging imaging modality, providing new capabilities in both anatomical and functional imaging of biological tissue. It relies on visible light illumination, whereas most commercial and investigational OCTs use near-infrared light. As a result, vis-OCT requires different considerations in engineering design and implementation but brings unique potential benefits to both fundamental research and clinical care of several diseases. Here, we intend to provide a summary of the development of vis-OCT and its demonstrated applications. We also provide perspectives on future technology improvement and applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Huang, D., Swanson, E. A., Lin, C. P., Schuman, J. S., Stinson, W. G., Chang, W., Hee, M. R., Flotte, T., Gregory, K., Puliafito, C. A., et al. (1991) · Science · doi:10.1126/science.1957169 · Cited by 13,788
Nickla, D. L., & Wallman, J. (2010) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2009.12.002 · Cited by 1,945 · cited 1×
“82,83 Therefore, not only were the major choroidal vessels never resolved by vis-OCT but also the signals from choriocapillaris were weak due to stronger attenuation of visible light by the RPE.”
BackgroundOptical coherence tomography - principles and applications
Fercher, A. F., Drexler, W., Hitzenberger, C. K., & Lasser, T. (2003) · Reports on Progress in Physics · doi:10.1088/0034-4885/66/2/204 · Cited by 1,866 · cited 1×
“2,4 So far, SLDs have dominated in commercial OCT systems.”
BackgroundSensitivity advantage of swept source and Fourier domain optical coherence tomography
Choma, M., Sarunic, M., Yang, C., & Izatt, J. (2003) · Optics Express · doi:10.1364/oe.11.002183 · Cited by 1,794 · cited 1×
“…in TD acquisition and later evolved into SD acquisition, vis-OCT systems also adopted SD setup after their original demonstration of concept in TD. 31,42,61 In addition to much higher imaging speed, SD acquisition also improves sensitivity, 62 which is important for in vivo functional imaging.”
BackgroundSpaide, R. F., Klancnik, J. M., & Cooney, M. J. (2015) · JAMA Ophthalmology · doi:10.1001/jamaophthalmol.2014.3616 · Cited by 1,620
von Braunmühl, T. (2015) · Der Hautarzt · doi:10.1007/s00105-015-3607-z · Cited by 1,033
de Boer, J. F., Milner, T. E., van Gemert, M. J. C., & Nelson, J. S. (1997) · Optics Letters · doi:10.1364/ol.22.000934 · Cited by 883
Jia, Y., Bailey, S. T., Wilson, D. J., Tan, O., Klein, M. L., Flaxel, C. J., Potsaid, B., Liu, J. J., Lu, C. D., Kraus, M. F., et al. (2014) · Ophthalmology · doi:10.1016/j.ophtha.2014.01.034 · Cited by 729
Theory, developments and applications of optical coherence tomography
Tomlins, P. H., & Wang, R. K. (2005) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/38/15/002 · Cited by 631
FUNDUS AUTOFLUORESCENCE IMAGING: Review and Perspectives
SCHMITZ-VALCKENBERG, S., HOLZ, F. G., BIRD, A. C., & SPAIDE, R. F. (2008) · Retina · doi:10.1097/iae.0b013e318164a907 · Cited by 537 · cited 1×
“84 Vis-OCT can be readily integrated with FAF imaging without requiring an additional light source.”
MethodEffects of blue light on the circadian system and eye physiology
Tosini, G., Ferguson, I., & Tsubota, K. (2016) · Molecular Vision · doi:10.63500/mv_v22_61 · Cited by 517 · cited 1×
“86 To minimize the hazard associated with visible light, investigators always select the illumination band of vis-OCT beyond 500 nm and strictly follow the latest ANSI Z136.”
BackgroundSpectroscopic optical coherence tomography
Morgner, U., Drexler, W., Kärtner, F. X., Li, X. D., Pitris, C., Ippen, E. P., & Fujimoto, J. G. (2000) · Optics Letters · doi:10.1364/ol.25.000111 · Cited by 516
Maximum permissible exposures for ocular safety (ANSI 2000), with emphasis on ophthalmic devices
Delori, F. C., Webb, R. H., & Sliney, D. H. (2007) · Journal of the Optical Society of America A · doi:10.1364/josaa.24.001250 · Cited by 480 · cited 1×
“Exposure to a spatially coherent light source in medical imaging can be hazardous to retina through thermal, thermoacoustic, and photochemical effects.(85) Human retina is more susceptible to damage from visible light due to the sensitivity of photoreceptors to the visible range of electromagnetic spectrum and the hig…”
BackgroundA literature review and novel theoretical approach on the optical properties of whole blood
Bosschaart, N., Edelman, G. J., Aalders, M. C. G., van Leeuwen, T. G., & Faber, D. J. (2014) · Lasers in Medical Science · doi:10.1007/s10103-013-1446-7 · Cited by 459 · cited 1×
“W relates to hematocrit of blood, H , as 77 ;temp:intralink-;e013;326;463 Both absorption and scattering coefficient spectra are available from the literature 77 and the hematocrit value does not have large variation and can be measured by routine clinical practice.”
BackgroundDoppler Optical Coherence Tomography
Leitgeb, R. A., Werkmeister, R. M., Blatter, C., & Schmetterer, L. (2014) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2014.03.004 · Cited by 444
Optical coherence tomography in dermatology
Sattler, E., Kästle, R., & Welzel, J. (2013) · Journal of Biomedical Optics · doi:10.1117/1.jbo.18.6.061224 · Cited by 283
Spectral measurement of absorption by spectroscopic frequency-domain optical coherence tomography
Leitgeb, R., Wojtkowski, M., Kowalczyk, A., Hitzenberger, C. K., Sticker, M., & Fercher, A. F. (2000) · Optics Letters · doi:10.1364/ol.25.000820 · Cited by 267 · cited 1×
“66 Despite the tradeoff between spectral resolution and spatial resolution, as is common with all TF analysis, sOCT can reveal the absorption and scattering spectra of biological tissues in 3-D.”
BackgroundFerrara, D., Waheed, N. K., & Duker, J. S. (2016) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2015.10.002 · Cited by 265 · cited 1×
“In contrast to the retinal circulation, which has well organized and easy-to-image major blood vessels close to the inner retinal surface, the choroidal circulation is beneath the highly optically absorbing and scattering RPE, and the major arteries and veins are covered under a dense meshwork of choriocapillaris.(82,…”
BackgroundOptical coherence tomography – development, principles, applications
Fercher, A. F. (2010) · Zeitschrift für Medizinische Physik · doi:10.1016/j.zemedi.2009.11.002 · Cited by 259 · cited 2×
“It provides threedimensional (3-D) in vivo optical tissue biopsy noninvasively with fine resolution in both lateral and axial dimensions at a penetration depth up to a few millimeters.(4) OCT has been applied in various investigational and clinical fields, including dermatology,(5) cardiology,(6) urology,(7) dentistry…”
BackgroundMethodSirtinol promotes PEPCK1 degradation and inhibits gluconeogenesis by inhibiting deacetylase SIRT2
Zhang, M., Pan, Y., Dorfman, R. G., Yin, Y., Zhou, Q., Huang, S., Liu, J., & Zhao, S. (2017) · Scientific Reports · doi:10.1038/s41598-017-00035-9 · Cited by 250
Dental Optical Coherence Tomography
Hsieh, Y.-S., Ho, Y.-C., Lee, S.-Y., Chuang, C.-C., Tsai, J.-C., Lin, K.-F., & Sun, C.-W. (2013) · Sensors · doi:10.3390/s130708928 · Cited by 179
Yi, J., Liu, W., Chen, S., Backman, V., Sheibani, N., Sorenson, C. M., Fawzi, A. A., Linsenmeier, R. A., & Zhang, H. F. (2015) · Light: Science & Applications · doi:10.1038/lsa.2015.107 · Cited by 177 · cited 1×
“38 The same study also suggested that inner retinal MRO 2 increases during hypoxic challenge because the highly regulated inner retinal circulation needs to compensate for the deficient oxygen supply from the poorly regulated choroidal circulation during decreased systemic oxygen supply.”
BackgroundSelf-citationAssayag, O. (2013) · TCRT Express · doi:10.7785/tcrtexpress.2013.600254 · Cited by 168
Speckle-modulating optical coherence tomography in living mice and humans
Liba, O., Lew, M. D., SoRelle, E. D., et al. (2017) · Nature Communications · doi:10.1038/ncomms15845 · Cited by 154 · cited 1×
“24,72 Recently, Liba et al. 88 developed speckle-modulating OCT, which used a moving diffuser to induce time-varying speckle patterns for static tissue so that they can be removed by averaging temporarily.”
BackgroundFunctional optical coherence tomography: principles and progress
Kim, J., Brown, W. J., Maher, J. R., Levinson, H., & Wax, A. P. (2015) · Physics in Medicine and Biology · doi:10.1088/0031-9155/60/10/r211 · Cited by 122
Chong, S. P., Merkle, C. W., Leahy, C., Radhakrishnan, H., & Srinivasan, V. J. (2015) · Biomedical Optics Express · doi:10.1364/boe.6.001429 · Cited by 116 · cited 6×
“15,24,25 The first report of vis-OCT dates back to 2002, 31 after which both the system implementation and processing algorithms have evolved significantly.”
BackgroundMethodInfluentialOptical Coherence Tomography: 15 Years in Cardiology
Yonetsu, T., Bouma, B. E., Kato, K., Fujimoto, J. G., & Jang, I. (2013) · Circulation Journal · doi:10.1253/circj.cj-13-0643.1 · Cited by 107
Depth resolved detection of lipid using spectroscopic optical coherence tomography
Fleming, C. P., Eckert, J. E., Halpern, E. F., Gardecki, J. A., & Tearney, G. J. (2013) · Biomedical Optics Express · doi:10.1364/boe.4.001269 · Cited by 86 · cited 1×
“67,68 Though studies have investigated exogenous dyes to enhance the contrast of sOCT, 69 primary interests have been focused on imaging endogenous chromophores, especially hemoglobin.”
BackgroundYi, J., Chen, S., Shu, X., Fawzi, A. A., & Zhang, H. F. (2015) · Biomedical Optics Express · doi:10.1364/boe.6.003701 · Cited by 83 · cited 8×
“40 Therefore, vis-OCT is primarily suitable for imaging superficial tissue while providing fine resolution and different spectroscopic contrast.”
BackgroundInfluentialSelf-citationHuang, X.-R., Zhou, Y., Kong, W., & Knighton, R. W. (2011) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.11-7665 · Cited by 81 · cited 1×
“…contrast and higher resolution in imaging RNFL. 22,40 In addition, before changes in retinal layer thickness can be observed, subdiffraction cellular damages were found to be encoded in the scattering spectrum within the visible spectral range, 45,91,92 which can potentially be detected by vis-OCT.”
BackgroundCerebral metabolic rate of oxygen (CMRO_2) assessed by combined Doppler and spectroscopic OCT
Chong, S. P., Merkle, C. W., Leahy, C., & Srinivasan, V. J. (2015) · Biomedical Optics Express · doi:10.1364/boe.6.003941 · Cited by 80 · cited 1×
“Therefore, spectroscopic analysis of OCT signal from blood can provide oxygen saturation (sO2), which, combined with flow velocity and vessel diameter measurements, can ultimately provide comprehensive evaluation of oxygen metabolism.(44,50) However, since the relative concentrations of HbO2 and Hb are estimated by th…”
BackgroundLichtenegger, A., Harper, D. J., Augustin, M., Eugui, P., Muck, M., Gesperger, J., Hitzenberger, C. K. F., Wöehrer, A., & Baumann, B. (2017) · Biomedical Optics Express · doi:10.1364/boe.8.004007 · Cited by 68 · cited 2×
“To minimize chromatic aberration, Lichtenegger et al 30 employed reflective collimators to maintain optimal spectrometer focus across a wide spectral range extending from 450 to 650 nm.”
BackgroundMethodShu, X., Li, H., Dong, B., Sun, C., & Zhang, H. F. (2017) · Biomedical Optics Express · doi:10.1364/boe.8.002851 · Cited by 67 · cited 2×
“40,93 In addition, since the RPE melanin has stronger absorption and scattering within the visible spectral range than within NIR spectral range, 94 vis-OCT images can be more sensitive to the variation in the RPE melanin concentration.”
BackgroundSelf-citationAdaptive optics optical coherence tomography in glaucoma
Dong, Z. M., Wollstein, G., Wang, B., & Schuman, J. S. (2016) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2016.11.001 · Cited by 66 · cited 1×
“90 Vis-OCT will be likely to bring more benefit in clinical diagnosis and management of glaucoma since it has demonstrated higher contrast and higher resolution in imaging RNFL. 22,40 In addition, before changes in retinal layer thickness can be observed, subdiffraction cellular damages were found…”
BackgroundIn vivo functional microangiography by visible-light optical coherence tomography
Yi, J., Chen, S., Backman, V., & Zhang, H. F. (2014) · Biomedical Optics Express · doi:10.1364/boe.5.003603 · Cited by 65 · cited 2×
“15,32 In this section, we summarize applications of vis-OCT to brain cortex and FRT, which can either provide scientific implication or be of clinical interest.”
MethodSelf-citationRetinal oximetry in humans using visible-light optical coherence tomography [Invited]
Chen, S., Shu, X., Nesper, P. L., Liu, W., Fawzi, A. A., & Zhang, H. F. (2017) · Biomedical Optics Express · doi:10.1364/boe.8.001415 · Cited by 64
Self-citationYi, J., & Li, X. (2010) · Optics Letters · doi:10.1364/ol.35.002094 · Cited by 56
Polans, J., Keller, B., Carrasco‐Zevallos, O. M., LaRocca, F., Cole, E., Whitson, H. E., Lad, E. M., Farsiu, S., & Izatt, J. A. (2016) · Biomedical Optics Express · doi:10.1364/boe.8.000016 · Cited by 53 · cited 2×
“74,76 We have EQ-TARGET;temp:intralink-;e007;63;642 I FD ;z ð k; τ z Þ ¼ STFT ½ ˜ I FD ð z Þ ; w z ð τ z ; ω z Þ(cid”
BackgroundInner retinal oxygen metabolism in the 50/10 oxygen-induced retinopathy model
Soetikno, B. T., Yi, J., Shah, R. S., Liu, W., Purta, P., Zhang, H. F., & Fawzi, A. A. (2015) · Scientific Reports · doi:10.1038/srep16752 · Cited by 49 · cited 2×
“Soetikno et al. 47 created 50/10 oxygen-induced retinopathy (OIR) in rat, which mimics RoP symptoms, and applied vis-OCT to study both the structural and functional evolution of retina in disease progression, as shown in Fig.”
MethodSelf-citationChen, S., Liu, Q., Shu, X., Soetikno, B. T., Tong, S., & Zhang, H. F. (2016) · Biomedical Optics Express · doi:10.1364/boe.7.003377 · Cited by 45 · cited 6×
“According to Chen et al., the noise-affected OCT signal intensity follows the nonsymmetrical Rice distribution.”
BackgroundMethodInfluentialSelf-citationThe Effect of Retinal Melanin on Optical Coherence Tomography Images
Wilk, M. A., Huckenpahler, A. L., Collery, R. F., Link, B. A., & Carroll, J. (2017) · Translational Vision Science & Technology · doi:10.1167/tvst.6.2.8 · Cited by 43 · cited 1×
“Wilk et al. 96 demonstrated qualitatively that the melanin concentration of the RPE may be reflected by its intensity and thickness in the OCT image.”
BackgroundShu, X., Bondu, M., Dong, B., et al. (2016) · Optics Letters · doi:10.1364/ol.41.002743 · Cited by 41 · cited 1×
“tral broadening of the pump laser through nonlinear effects in a photonic crystal fiber (PCF).(19) Swept sources are different”
BackgroundSelf-citationTatebe, S., Fukumoto, Y., Sugimura, K., Miura, Y., Nochioka, K., Aoki, T., Miura, M., Yamamoto, S., Yaoita, N., Satoh, K., et al. (2013) · Circulation Journal · doi:10.1253/circj.cj-12-1493 · Cited by 41
Liu, Q., Chen, S., Soetikno, B. T., Liu, W., Tong, S., & Zhang, H. F. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2017.2706976 · Cited by 40 · cited 6×
“In another study, Liu et al. 52 created a distal middle cerebral artery occlusion (dMCAO) model in mice, which mimics human cortical stroke, by bipolar electrosurgical coagulation and used laser speckle imaging (LSI) guided vis-OCT to investigate the influence of occlusion on the brain…”
BackgroundMethodInfluentialSelf-citationShah, R. S., Soetikno, B. T., Yi, J., Liu, W., Skondra, D., Zhang, H. F., & Fawzi, A. A. (2016) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.15-18891 · Cited by 36
Self-citationBondu, M., Brooks, C. D., Jakobsen, C. L., Oakes, K., Moselund, P. M., Leick, L., Bang, O., & Podoleanu, A. G. (2016) · Journal of Biomedical Optics · doi:10.1117/1.jbo.21.6.061005 · Cited by 35
Accuracy of retinal oximetry: a Monte Carlo investigation
Liu, W., Jiao, S., & Zhang, H. F. (2013) · Journal of Biomedical Optics · doi:10.1117/1.jbo.18.6.066003 · Cited by 35
Self-citationIncreased Retinal Oxygen Metabolism Precedes Microvascular Alterations in Type 1 Diabetic Mice
Liu, W., Wang, S., Soetikno, B. T., Yi, J., Zhang, K. X., Chen, S., Linsenmeier, R. A., Sorenson, C. M., Sheibani, N., & Zhang, H. F. (2017) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.16-20600 · Cited by 34
Self-citationDual-band optical coherence tomography using a single supercontinuum laser source
Chen, S., Shu, X., Yi, J., Fawzi, A. A., & Zhang, H. F. (2016) · Journal of Biomedical Optics · doi:10.1117/1.jbo.21.6.066013 · Cited by 30 · cited 3×
“The smooth broadband spectrum of SC sources provides large flexibility for illumination band selection, facilitating ultra-broadband OCT and multiband OCT. 21 However, SC sources exhibit much higher relative intensity noise (RIN) 61 as compared with SLDs.”
BackgroundSelf-citationLiu, R., Spicer, G. L. C., Chen, S., Zhang, H. F., Yi, J., & Backman, V. (2017) · Journal of Biomedical Optics · doi:10.1117/1.jbo.22.2.025002 · Cited by 29
Self-citationSoetikno, B. T., Shu, X., Liu, Q., et al. (2017) · Biomedical Optics Express · doi:10.1364/boe.8.003571 · Cited by 26 · cited 1×
“89 In addition to retinal hemodynamic investigations, vis-OCT may also be applied to early detection of glaucoma and age-related macular degeneration (AMD).”
BackgroundSelf-citationYi, J., Puyang, Z., Feng, L., Duan, L., Liang, P., Backman, V., Liu, X., & Zhang, H. F. (2016) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.16-19955 · Cited by 26 · cited 1×
“…contrast and higher resolution in imaging RNFL. 22,40 In addition, before changes in retinal layer thickness can be observed, subdiffraction cellular damages were found to be encoded in the scattering spectrum within the visible spectral range, 45,91,92 which can potentially be detected by vis-OCT.”
BackgroundSelf-citationNafar, Z., Jiang, M., Wen, R., & Jiao, S. (2016) · Biomedical Optics Express · doi:10.1364/boe.7.003220 · Cited by 26 · cited 1×
“In addition, by taking the ratio of the vis-OCT signal intensity and AF signal intensity at RPE, true RPE AF intensity, which is independent of incident light intensity and the attenuation of eye components anterior to RPE, can potentially be quantified.(49) The shorter illumination wavelength of vis-OCT also makes it…”
BackgroundShu, X., Liu, W., & Zhang, H. F. (2015) · Journal of Biomedical Optics · doi:10.1117/1.jbo.20.10.106005 · Cited by 25 · cited 4×
“94,95 However, OCT imaging is based on backscattering and the absorption measurement requires comparing the signal intensities of reference tissue layers above and beneath the RPE.”
BackgroundInfluentialSelf-citationIn vivo analysis of burns in a mouse model using spectroscopic optical coherence tomography
Maher, J. R., Jaedicke, V., Medina, M., Levinson, H., Selim, M. A., Brown, W. J., & Wax, A. P. (2014) · Optics Letters · doi:10.1364/ol.39.005594 · Cited by 23 · cited 1×
“67,68 Though studies have investigated exogenous dyes to enhance the contrast of sOCT, 69 primary interests have been focused on imaging endogenous chromophores, especially hemoglobin.”
BackgroundZhang, L., Capilla, A., Song, W., Mostoslavsky, G., & Yi, J. (2017) · Scientific Reports · doi:10.1038/s41598-017-08822-0 · Cited by 17 · cited 1×
“23,54 57 In this article, we review the development of vis-OCT, including both methodology and application.”
MethodJiang, M., Liu, T., Liu, X., & Jiao, S. (2014) · Biomedical Optics Express · doi:10.1364/boe.5.004242 · Cited by 17 · cited 1×
“Since vis-OCT and FAF share the same illumination beam and scanning optics, the dual-modal system can acquire two types of images simultaneously, which are naturally coregistered.(55,56) In addition, by taking the ratio of the vis-OCT signal intensity and AF signal intensity at RPE, true RPE AF intensity, which is ind…”
BackgroundMegahertz FDML laser with up to 143nm sweep range for ultrahigh resolution OCT at 1050nm
Kolb, J. P., Klein, T., Eibl, M., Pfeiffer, T., Wieser, W., & Huber, R. A. (2016) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2214758 · Cited by 10
Visible-light OCT spectrometer for microvascular oximetry
Gangnus, S. V., & Matcher, S. J. (2008) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.761254 · Cited by 5
Chen, S., Yi, J., Dong, B., Sun, C., Kiser, P. F., Hope, T. J., & Zhang, H. F. (2015) · PubMed · doi:10.3978/j.issn.2223-4292.2014.11.03 · Cited by 4 · cited 2×
“54”
MethodSelf-citation
Cited by
Nano-optic endoscope for high-resolution optical coherence tomography in vivo
Pahlevaninezhad, H., Khorasaninejad, M., Huang, Y.-W., Shi, Z., Hariri, L. P., Adams, D. C., Ding, V., Zhu, A., Qiu, C.-W., Capasso, F., et al. (2018) · Nature Photonics · doi:10.1038/s41566-018-0224-2 · Cited by 412
Spectral tracing of deuterium for imaging glucose metabolism
Zhang, L., Shi, L., Shen, Y., Miao, Y., Wei, M., Qian, N., Liu, Y., & Min, W. (2019) · Nature Biomedical Engineering · doi:10.1038/s41551-019-0393-4 · Cited by 196
Paracentral acute middle maculopathy and the organization of the retinal capillary plexuses
Scharf, J., Freund, K. B., Sadda, S., & Sarraf, D. (2021) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2020.100884 · Cited by 177
Metadata
- Authors
- Shu, X., Beckmann, L., & Zhang, H. F.
- Venue
- Journal of Biomedical Optics
- Publisher
- SPIE-Intl Soc Optical Eng
- Published
- 2017-12-07
- Volume
- 22
- Issue
- 12
- Pages
- 1
- ISSN
- 1083-3668 (ISSN-L)
- OpenAlex
- W2775439418
- Cited by
- 173
- References
- 60
- FWCI
- 7.22
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.