Review of optical coherence tomography in oncology
Open accessThe DOI matches its Crossref record; 103 of the 103 references it cites were found in a registry or an index.
Abstract
The application of optical coherence tomography (OCT) in the field of oncology has been prospering over the past decade. OCT imaging has been used to image a broad spectrum of malignancies, including those arising in the breast, brain, bladder, the gastrointestinal, respiratory, and reproductive tracts, the skin, and oral cavity, among others. OCT imaging has initially been applied for guiding biopsies, for intraoperatively evaluating tumor margins and lymph nodes, and for the early detection of small lesions that would often not be visible on gross examination, tasks that align well with the clinical emphasis on early detection and intervention. Recently, OCT imaging has been explored for imaging tumor cells and their dynamics, and for the monitoring of tumor responses to treatments. This paper reviews the evolution of OCT technologies for the clinical application of OCT in surgical and noninvasive interventional oncology procedures and concludes with a discussion of the future directions for OCT technologies, with particular emphasis on their applications in oncology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Global cancer statistics, 2012
Torre, L. A., Bray, F., Siegel, R. L., Ferlay, J., Lortet‐Tieulent, J., & Jemal, A. (2015) · CA: A Cancer Journal for Clinicians · doi:10.3322/caac.21262 · Cited by 26,850 · cited 1×
“With over 2,807,400 new cases of GI cancer (esophagus: 455,800; stomach: 951,600; and colon: 1,400,000) each year, 88 it is not surprising that GI tissues have been heavily inter-rogated with OCT.”
BackgroundHuang, D., Swanson, E. A., Lin, C. P., Schuman, J. S., Stinson, W. G., Chang, W., Hee, M. R., Flotte, T., Gregory, K., Puliafito, C. A., et al. (1991) · Science · doi:10.1126/science.1957169 · Cited by 13,788
In vivo near-infrared fluorescence imaging
Frangioni, J. V. (2003) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2003.08.007 · Cited by 2,653
(2006) · Cancer · doi:10.1002/(issn)1097-0142 · Cited by 1,470
The Chemistry of Contrast Agents in Medical Magnetic Resonance Imaging
(2013) · Wiley eBooks · doi:10.1002/9781118503652 · Cited by 1,468
Supernormal vision and high-resolution retinal imaging through adaptive optics
Liang, J., Williams, D. R., & Miller, D. T. (1997) · Journal of the Optical Society of America A · doi:10.1364/josaa.14.002884 · Cited by 1,454 · cited 1×
“Hardware-based adaptive optics 181 and coherence-gated sensor-less adaptive optics 182 have been developed for optical aberration compensation.”
BackgroundIn Vivo Endoscopic Optical Biopsy with Optical Coherence Tomography
Tearney, G. J., Brezinski, M. E., Bouma, B. E., Boppart, S. A., Pitris, C., Southern, J. F., & Fujimoto, J. G. (1997) · Science · doi:10.1126/science.276.5321.2037 · Cited by 1,364
Self-citationUltrasound Microbubble Contrast Agents: Fundamentals and Application to Gene and Drug Delivery
Ferrara, K., Pollard, R., & Borden, M. (2007) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.8.061505.095852 · Cited by 1,288
X-ray-Computed Tomography Contrast Agents
Lusic, H., & Grinstaff, M. W. (2013) · Chemical Reviews · doi:10.1021/cr200358s · Cited by 1,108
Lasers in Surgery and Medicine
(2006) · Lasers in Surgery and Medicine · doi:10.1002/(issn)1096-9101 · Cited by 1,088
von Braunmühl, T. (2015) · Der Hautarzt · doi:10.1007/s00105-015-3607-z · Cited by 1,033
Gold Nanocages: Bioconjugation and Their Potential Use as Optical Imaging Contrast Agents
Chen, J., Saeki, F., Wiley, B. J., Cang, H., Cobb, M. J., Li, Z.-Y., Au, L., Zhang, H., Kimmey, M. B., Li, X., et al. (2005) · Nano Letters · doi:10.1021/nl047950t · Cited by 977
Assessment of the Evolution of Cancer Treatment Therapies
Arruebo, M., Vilaboa, N., Sáez-Gutierrez, B., Lambea, J., Tres, A., Valladares, M., & González-Fernández, Á. (2011) · Cancers · doi:10.3390/cancers3033279 · Cited by 931 · cited 1×
“Usually, chemotherapy, radiotherapy, ablative therapy (thermal, cryo/freezing), photodynamic therapy (PDT), and vasculartargeting therapies with or without surgery are the most common types of cancer treatments available.(157,158) Considering that different therapeutic strategies exhibit different markers of an effect…”
BackgroundRivera, C. (2015) · PubMed · doi:10.5281/zenodo.192487 · Cited by 818
New Technologies for Human Cancer Imaging
Frangioni, J. V. (2008) · Journal of Clinical Oncology · doi:10.1200/jco.2007.14.3065 · Cited by 800
Vakoc, B. J., Lanning, R. M., Tyrrell, J. A., Padera, T. P., Bartlett, L. A., Stylianopoulos, T., Munn, L. L., Tearney, G. J., Fukumura, D., Jain, R. K., et al. (2009) · Nature Medicine · doi:10.1038/nm.1971 · Cited by 719 · cited 1×
“166 This study imaged mice with MCaIV (murine breast carcinoma) tumors during treatment with vascular endothelial growth factor receptor-2 (VEGFR-2)- blocking monoclonal antibody DC101.”
BackgroundQuantitative Assessment of Macular Edema With Optical Coherence Tomography
Hee, M. R. (1995) · Archives of Ophthalmology · doi:10.1001/archopht.1995.01100080071031 · Cited by 710
McLaughlin, S. A., Wright, M. J., Morris, K. T., Giron, G. L., Sampson, M. R., Brockway, J. P., Hurley, K. E., Riedel, E. R., & Van Zee, K. J. (2008) · Journal of Clinical Oncology · doi:10.1200/jco.2008.16.3725 · Cited by 638 · cited 1×
“37 Therefore, the reported OCT study for breast cancer is largely focused on the differentiation of normal versus cancerous breast tissues with different subtypes for “ optical biopsy, ” accurate surgical margin detection, and precise evaluation of axillary lymph nodes for breast cancer staging…”
BackgroundOptical coherence tomography: a review of clinical development from bench to bedside
Zysk, A. M., Nguyen, F. T., Oldenburg, A. L., Marks, D. L., & Boppart, S. A. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2793736 · Cited by 547
Self-citationOptical Coherence Tomography of Ocular Diseases
Schuman, J. S., Fujimoto, J. G., Duker, J., & Ishikawa, H. (2024) · CRC Press eBooks · doi:10.1201/9781003525455 · Cited by 484
Liu, L., Gardecki, J. A., Nadkarni, S. K., Toussaint, J. D., Yagi, Y., Bouma, B. E., & Tearney, G. J. (2011) · Nature Medicine · doi:10.1038/nm.2409 · Cited by 463
High-resolution optical coherence tomography over a large depth range with an axicon lens
Ding, Z., Ren, H., Zhao, Y., Nelson, J. S., & Chen, Z. (2002) · Optics Letters · doi:10.1364/ol.27.000243 · Cited by 367 · cited 1×
“Examples include wavefront engineering for non-Gaussian beam illumination, 173 – 178 complex wavefront shaping, 179 and depth-encoded synthetic apertures 180 to obtain a large DOF image with high transverse resolution.”
BackgroundImprovements in cancer staging with PET/CT: literature-based evidence as of September 2006.
Czernin, J. G., Allen-Auerbach, M., & Schelbert, H. R. (2007) · PubMed · Cited by 355
Optical coherence tomography and microscopy in gastrointestinal tissues
Izatt, J. A., Kulkarni, M. D., Wang, H.-W., Kobayashi, K., & Sivak, M. V. (1996) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/2944.577331 · Cited by 350
Kut, C., Chaichana, K. L., Xi, J., Raza, S. M., Ye, X., McVeigh, E. R., Rodriguez, F. J., Quiñones-Hinojosa, A., & Li, X. (2015) · Science Translational Medicine · doi:10.1126/scitranslmed.3010611 · Cited by 323 · cited 3×
“16 The first in vivo OCT imaging of human brain was also reported.”
BackgroundVascular‐targeting therapies for treatment of malignant disease
Siemann, D. W., Chaplin, D. J., & Horsman, M. R. (2004) · Cancer · doi:10.1002/cncr.20299 · Cited by 310
Gora, M. J., Sauk, J. S., Carruth, R. W., Gallagher, K. A., Suter, M. J., Nishioka, N. S., Kava, L., Rosenberg, M., Bouma, B. E., & Tearney, G. J. (2013) · Nature Medicine · doi:10.1038/nm.3052 · Cited by 310 · cited 2×
“5(d)–5(g)].(107) Further 3-D fly-through movies show that the surface of the squamous mucosa is relatively smooth and has a higher OCT signal starting at the proximal end of the esophagus.”
BackgroundMethodAdaptive wavefront correction in two-photon microscopy using coherence-gated wavefront sensing
Rueckel, M., Mack-Bucher, J. A., & Denk, W. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0604791103 · Cited by 307 · cited 1×
“Hardware-based adaptive optics 181 and coherence-gated sensor-less adaptive optics 182 have been developed for optical aberration compensation.”
BackgroundChoe, R., Corlu, A., Lee, K., Durduran, T., Konecky, S. D., Grosicka‐Koptyra, M., Arridge, S. R., Czerniecki, B. J., Fraker, D. L., DeMichele, A., et al. (2005) · Medical Physics · doi:10.1118/1.1869612 · Cited by 295
Diagnosis of specialized intestinal metaplasia by optical coherence tomography
Poneros, J. M., Brand, S., Bouma, B. E., Tearney, G. J., Compton, C. C., & Nishioka, N. S. (2001) · Gastroenterology · doi:10.1053/gast.2001.20911 · Cited by 291 · cited 3×
“92 In 2005, ultrahigh-resolution OCT, characterized by an axial resolution of 5 μ m , and 3-”
BackgroundOptical coherence tomography in dermatology
Sattler, E., Kästle, R., & Welzel, J. (2013) · Journal of Biomedical Optics · doi:10.1117/1.jbo.18.6.061224 · Cited by 283
Boppart, S. A., Luo, W., Marks, D. L., & Singletary, K. W. (2004) · Breast Cancer Research and Treatment · doi:10.1023/b:brea.0000018401.13609.54 · Cited by 256
Self-citationHammoud, M. A., Ligon, B. L., Elsouki, R., Shi, W. M., Schomer, D. F., & Sawaya, R. (1996) · Journal of Neurosurgery · doi:10.3171/jns.1996.84.5.0737 · Cited by 245
Early Stage Diagnosis of Oral Cancer Using 1H NMR–Based Metabolomics
Tiziani, S., Lopes, V., & Günther, U. L. (2009) · Neoplasia · doi:10.1593/neo.81396 · Cited by 237
Engineered microsphere contrast agents for optical coherence tomography
Lee, T.-M., Oldenburg, A. L., Sitafalwalla, S., Marks, D. L., Luo, W., Toublan, F. J.-J., Suslick, K. S., & Boppart, S. A. (2003) · Optics Letters · doi:10.1364/ol.28.001546 · Cited by 236
Self-citationGold nanocages as contrast agents for spectroscopic optical coherence tomography
Cang, H., Sun, T., Li, Z.-Y., Chen, J., Wiley, B. J., Xia, Y., & Li, X. (2005) · Optics Letters · doi:10.1364/ol.30.003048 · Cited by 234
MOGENSEN, M., JOERGENSEN, T. M., NÜRNBERG, B. M., MORSY, H. A., THOMSEN, J. B., THRANE, L., & JEMEC, G. B. E. (2009) · Dermatologic Surgery · doi:10.1111/j.1524-4725.2009.01164.x · Cited by 205
In vivo Optical Coherence Tomography Imaging of Preinvasive Bronchial Lesions
Lam, S., Standish, B., Baldwin, C., McWilliams, A., leRiche, J., Gazdar, A., Vitkin, A. I., Yang, V., Ikeda, N., & MacAulay, C. (2008) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-07-4418 · Cited by 197 · cited 2×
“In 2008, microscopic OCT imaging of lung tissues was performed under the guidance of autofluorescence bronchoscopy.(87) Quantitative measurement of the epithelial thickness using OCT showed that the epithelial thickness was significantly different between invasive lung cancer and carcinoma in situ (p 1⁄4 0.”
BackgroundMethodRizvi, I., Celli, J. P., Evans, C. L., Abu-Yousif, A. O., Muzikansky, A., Pogue, B. W., Finkelstein, D., & Hasan, T. (2010) · Cancer Research · doi:10.1158/0008-5472.can-10-1783 · Cited by 191 · cited 1×
“159 OCT is a good modality for 3-”
MethodIn vivo optical coherence tomography imaging of human skin: norm and pathology
Gladkova, N. D., Petrova, G. A., Nikulin, N. K., Radenska‐Lopovok, S. G., Snopova, L. B., Chumakov, Y. P., Nasonova, V. A., Gelikonov, V. M., Gelikonov, G. V., Kuranov, R. V., et al. (2000) · Skin Research and Technology · doi:10.1034/j.1600-0846.2000.006001006.x · Cited by 185
In vivo optical coherence tomography of basal cell carcinoma
Gambichler, T., Orlikov, A., Vasa, R. A., Moussa, G., Hoffmann, K. K. P., Stücker, M., Altmeyer, P. J., & Bechara, F. G. (2007) · Journal of Dermatological Science · doi:10.1016/j.jdermsci.2006.11.012 · Cited by 169 · cited 5×
“001).(130) OCT has also been used to evaluate skin precancer (AK, actinic keratosis).”
BackgroundMethodResultInfluentialAssayag, O. (2013) · TCRT Express · doi:10.7785/tcrtexpress.2013.600254 · Cited by 168
Assayag, O., Grieve, K., Devaux, B., Harms, F., Pallud, J., Chretien, F., Boccara, C., & Varlet, P. (2013) · NeuroImage: Clinical · doi:10.1016/j.nicl.2013.04.005 · Cited by 168 · cited 2×
“70 With ultrahigh-resolution OCT (UHR-OCT), researchers have identified the morphological features, such as microcalcifications ( > 20 μ m ), enlarged nuclei of tumor cells ( ∼ 8 to 15 μ m ), small cysts, and blood vessels, which are characteristic of neuropathologies and normally absent in healthy…”
BackgroundPolarization-sensitive optical coherence tomography of invasive basal cell carcinoma
Strasswimmer, J., Pierce, M. C., Park, B. H., Neel, V., & de Boer, J. F. (2004) · Journal of Biomedical Optics · doi:10.1117/1.1644118 · Cited by 167
Optical coherence micro-elastography: mechanical-contrast imaging of tissue microstructure
Kennedy, B. F., McLaughlin, R. A., Kennedy, K. M., Chin, L., Curatolo, A., Tien, A., Latham, B., Saunders, C. M., & Sampson, D. D. (2014) · Biomedical Optics Express · doi:10.1364/boe.5.002113 · Cited by 160
Skala, M. C., Crow, M. J., Wax, A. P., & Izatt, J. A. (2008) · Nano Letters · doi:10.1021/nl802351p · Cited by 159
High definition live 3D-OCT in vivo: design and evaluation of a 4D OCT engine with 1 GVoxel/s
Wieser, W., Draxinger, W., Klein, T., Karpf, S., Pfeiffer, T., & Huber, R. A. (2014) · Biomedical Optics Express · doi:10.1364/boe.5.002963 · Cited by 157 · cited 1×
“…OCT acquisition and visualization has been demonstrated with a benchtop SS-OCT system enabled by a high-sweep rate Fourier-domain mode-locked laser and graphics processing unit (GPU)-based data processing, 170 as well as by benchtop SD-OCT facilitated by optical demultiplexers, an FPGA, and a GPU.”
MethodChoi, W. J., Jeon, D.-I., Ahn, S., Yoon, J., Kim, S., & Lee, B. H. (2010) · Optics Express · doi:10.1364/oe.18.023285 · Cited by 151 · cited 2×
“Experimental results showed that cancer cells have a higher refractive index than normal ones, demonstrating that FF-OCM has significant potential for cancer diagnosis and dynamic cell analysis as an in situ label-free biophysical assay.(26)”
BackgroundUsing optical coherence tomography to evaluate skin sun damage and precancer
Korde, V. R., Bonnema, G. T., Xu, W., Krishnamurthy, C., Ranger‐Moore, J., Saboda, K., Slayton, L. D., Salasche, S. J., Warneke, J. A., Alberts, D. S., et al. (2007) · Lasers in Surgery and Medicine · doi:10.1002/lsm.20573 · Cited by 145
Villiger, M., Lorenser, D., McLaughlin, R. A., Quirk, B. C., Kirk, R. W., Bouma, B. E., & Sampson, D. D. (2016) · Scientific Reports · doi:10.1038/srep28771 · Cited by 140 · cited 2×
“Similarly, deep volumetric imaging of human breast birefringence through the integration of side-viewing fiber-optic needle probes with PS-OCT was successfully realized.(36) Oblique sections from the imaged tissue cylinders that match the plane of the histological sections were retrieved to directly compare the observ…”
BackgroundResultZysk, A. M., & Boppart, S. A. (2006) · Journal of Biomedical Optics · doi:10.1117/1.2358964 · Cited by 132 · cited 1×
“The potential of OCT to be an effective tool for the detection of lesions in the human breast was confirmed with further studies.(4,38) Comprehensive work has also been completed to establish the correspondence of OCT image findings with histopathologic findings to better understand, which features characteristic of b…”
BackgroundSelf-citationIn situ structural and microangiographic assessment of human skin lesions with high-speed OCT
Blatter, C., Weingast, J., Alex, A., Grajciar, B., Wieser, W., Drexler, W., Huber, R. A., & Leitgeb, R. A. (2012) · Biomedical Optics Express · doi:10.1364/boe.3.002636 · Cited by 129
Kennedy, B. F., McLaughlin, R. A., Kennedy, K. M., Chin, L., Wijesinghe, P., Curatolo, A., Tien, A., Ronald, M., Latham, B. I., Saunders, C. M., et al. (2015) · Cancer Research · doi:10.1158/0008-5472.can-14-3694 · Cited by 124
Optical Coherence Elastography of Engineered and Developing Tissue
Ko, H.-J., Tan, W., Stack, R. A., & Boppart, S. A. (2006) · Tissue Engineering · doi:10.1089/ten.2006.12.63 · Cited by 124
Self-citationKotwall, C. A., Mahoney, L. J., Myers, R. E., & Decoste, L. (2006) · Journal of Surgical Oncology · doi:10.1002/(issn)1096-9098 · Cited by 122
Russell, E. B., Carrington, P. R., & Smoller, B. R. (1999) · Journal of the American Academy of Dermatology · doi:10.1016/s0190-9622(99)70409-3 · Cited by 118 · cited 1×
“128 Therefore, noninvasive but high-resolution techniques such as OCT have been explored for skin cancer detection.”
BackgroundComplex wavefront shaping for optimal depth-selective focusing in optical coherence tomography
Jang, J., Lim, J., Yu, H., Choi, H. W., Ha, J., Park, J., Oh, W., Jang, W., Lee, S., & Park, Y. (2013) · Optics Express · doi:10.1364/oe.21.002890 · Cited by 118 · cited 1×
“Examples include wavefront engineering for non-Gaussian beam illumination, 173 – 178 complex wavefront shaping, 179 and depth-encoded synthetic apertures 180 to obtain a large DOF image with high transverse resolution.”
BackgroundWilliamson, J., McLaughlin, R. A., Noffsinger, W., James, A. L., Baker, V. A., Curatolo, A., Armstrong, J. J., Regli, A., Shepherd, K., Marks, G. B., et al. (2011) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201002-0178oc · Cited by 115 · cited 1×
“With the development of anatomical OCT, it was demonstrated that it was possible to record dynamic changes in airway size and shape with OCT and measure the elastic properties of the central airway in obstructive lung diseases.(85) Further implementation of anatomical OCT on three different subjects such as one with s…”
BackgroundSchmidbauer, J., Mesut Remzi, A., Klatte, T., Waldert, M., Mauermann, J., Susani, M., & Marberger, M. (2009) · European Urology · doi:10.1016/j.eururo.2009.07.042 · Cited by 109
Combined Raman spectroscopy and optical coherence tomography device for tissue characterization
Patil, C. A., Bosschaart, N., Keller, M. D., van Leeuwen, T. G. J. M., & Mahadevan-Jansen, A. M. (2008) · Optics Letters · doi:10.1364/ol.33.001135 · Cited by 106 · cited 2×
“The device enhances application of both Raman spectroscopy and OCT by precisely guiding Raman spectra acquisition with OCT images while also compensating for the lack of molecular specificity in OCT with the biochemical specificity of Raman spectroscopy.(194) In addition, a side-viewing Raman spectroscopy-OCT probe wa…”
BackgroundMethodMcLaughlin, R. A., Quirk, B. C., Curatolo, A., Kirk, R. W., Scolaro, L., Lorenser, D., Robbins, P., Wood, B. A., Saunders, C. M., & Sampson, D. D. (2011) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/jstqe.2011.2166757 · Cited by 99
Tumlinson, A. R., Barton, J. K., Považay, B., Sattmann, H., Unterhuber, A., Leitgeb, R. A., & Drexler, W. (2006) · Optics Express · doi:10.1364/oe.14.001878 · Cited by 99 · cited 1×
“105 In addition, a comparative study between OCT and high-frequency catheter probe endoscopic ultrasound (CPEUS) was conducted.”
BackgroundBizheva, K. K., Unterhuber, A., Hermann, B. M., Považay, B., Sattmann, H., FERCHER, A. F., Drexler, W., Preusser, M., Budka, H., Stingl, A., et al. (2005) · Journal of Biomedical Optics · doi:10.1117/1.1851513 · Cited by 99 · cited 1×
“With ultrahigh-resolution OCT (UHR-OCT), researchers have identified the morphological features, such as microcalcifications (>20 μm), enlarged nuclei of tumor cells (∼8 to 15 μm), small cysts, and blood vessels, which are characteristic of neuropathologies and normally absent in healthy brain tissue.(64) The efficien…”
BackgroundRefractive index measurement of acute rat brain tissue slices using optical coherence tomography
Sun, J., Lee, S. J., Wu, L., Sarntinoranont, M., & Xie, H. (2012) · Optics Express · doi:10.1364/oe.20.001084 · Cited by 95
Scolaro, L., McLaughlin, R. A., Klyen, B. R., Wood, B. A., Robbins, P., Saunders, C. M., Jacques, S. L., & Sampson, D. D. (2012) · Biomedical Optics Express · doi:10.1364/boe.3.000366 · Cited by 91 · cited 17×
“94 OCM enabled cellular imaging of specimens from the upper and lower gastro-intestinal tracts over a smaller field of view, compared with OCT. Squamous cells and their nuclei, goblet cells in Barrett ’ s esophagus, gastric pits and colonic crypts, and fine structures in adenocarcinomas were all visualized.”
MethodInfluentialKennedy, K. M., McLaughlin, R. A., Kennedy, B. F., Tien, A., Latham, B. I., Saunders, C. M., & Sampson, D. D. (2013) · Journal of Biomedical Optics · doi:10.1117/1.jbo.18.12.121510 · Cited by 90 · cited 1×
“OCE measurements deep within human tissues using needle OCE was also demonstrated ex vivo, extending the potential of OCE as a surgical guidance tool.(35) An improved form of OCE was recently presented, named optical coherence microelastography (OCME), which is sensitive to the microscale variations in the mechanical…”
MethodOptical coherence tomography: Technology and applications for neuroimaging
Boppart, S. A. (2003) · Psychophysiology · doi:10.1111/1469-8986.00055 · Cited by 90
Self-citationOptical coherence tomography of cell dynamics in three-dimensional tissue models
Tan, W., Oldenburg, A. L., Norman, J. J., Desai, T. A., & Boppart, S. A. (2006) · Optics Express · doi:10.1364/oe.14.007159 · Cited by 89 · cited 1×
“Using OCT, a variety of cell processes, such as chemotaxis migration, proliferation, deadhesion, and cell–material interactions, were investigated in thick tissue models.(22,23) In addition, OCT can be used to monitor time-dependent changes associated with premalignant cells in vitro.”
BackgroundSelf-citationDiagnosing Lung Carcinomas with Optical Coherence Tomography
Hariri, L. P., Mino-Kenudson, M. A., Lanuti, M. D., Miller, A. J., Mark, E. J., & Suter, M. J. (2015) · Annals of the American Thoracic Society · doi:10.1513/annalsats.201408-370oc · Cited by 84 · cited 17×
“94 OCM enabled cellular imaging of specimens from the upper and lower gastro-intestinal tracts over a smaller field of view, compared with OCT. Squamous cells and their nuclei, goblet cells in Barrett ’ s esophagus, gastric pits and colonic crypts, and fine structures in adenocarcinomas were all visualized.”
Influentialvan der Meer, F. J., Faber, D. J., Aalders, M. C. G., Poot, A. A., Vermes, I., & van Leeuwen, T. G. J. M. (2009) · Lasers in Medical Science · doi:10.1007/s10103-009-0723-y · Cited by 84 · cited 2×
“7 mm−1 was observed.(162) Similarly, another study reported a gradual decrease in scattering associated with necrotic cells, which probably stemmed from their continuous disassembly.”
BackgroundResultHariri, L. P., Tumlinson, A. R., Besselsen, D. G., Utzinger, U., Gerner, E. W., & Barton, J. K. (2006) · Lasers in Surgery and Medicine · doi:10.1002/lsm.20305 · Cited by 84
Lingley-Papadopoulos, C. A., Loew, M. H., Manyak, M. J., & Zara, J. M. (2008) · Journal of Biomedical Optics · doi:10.1117/1.2904987 · Cited by 83 · cited 2×
“sensitivity of 92% and a specificity of 62%.(121) Limited detection specificity was also reported in another study.”
MethodResultFolarin, A., Konerding, M. A., TIMONEN, J., Nagl, S., & Pedley, R. B. (2010) · Microvascular Research · doi:10.1016/j.mvr.2010.03.007 · Cited by 82 · cited 1×
“Traditionally, ultrasound imaging 168 or microcomputed tomography ( μ CT ), 169 which have the advantages of large imaging fields and deep penetration, have been used for this purpose.”
MethodMarvdashti, T., Duan, L., Aasi, S. Z., Tang, J. Y., & Bowden, A. K. (2016) · Biomedical Optics Express · doi:10.1364/boe.7.003721 · Cited by 81 · cited 3×
“For instance, a fully automated procedure to detect BCC in ex vivo human skin from PS-OCT images was reported.(134) A total of 1314 features (613 from intensity data and 701 from polarization retardation data) were extracted from both intensity and polarization images, followed by the use of a support vector machine w…”
MethodInfluentialImaging of Human Lymph Nodes Using Optical Coherence Tomography: Potential for Staging Cancer
McLaughlin, R. A., Scolaro, L., Robbins, P., Hamza, S., Saunders, C. M., & Sampson, D. D. (2010) · Cancer Research · doi:10.1158/0008-5472.can-09-4062 · Cited by 79 · cited 1×
“54 Using three-dimensional OCT (3D-OCT), the first longitudinal study of 3-”
MethodDynamic spectral-domain optical coherence elastography for tissue characterization
Liang, X., Adie, S. G., John, R., & Boppart, S. A. (2010) · Optics Express · doi:10.1364/oe.18.014183 · Cited by 78 · cited 3×
“Furthermore, it has been found that OCE could identify regions, which were poorly differentiated in the OCT scattering image.(45) Unlike external OCE techniques, which may suffer from an inability to maintain a sterile in vivo environment, an internal and dynamic OCE method, namely acoustomotive OCE (AM-OCE), was intr…”
MethodInfluentialSelf-citationSouth, F. A., Chaney, E. J., Marjanović, M., Adie, S. G., & Boppart, S. A. (2014) · Biomedical Optics Express · doi:10.1364/boe.5.003417 · Cited by 75 · cited 4×
“Using a different variant of OCT, the capability of PS-OCT to differentiate ex vivo human breast tissue was investigated.(49) PSOCT images of breast cancer (i.”
BackgroundMethodInfluentialSelf-citationAcoustomotive optical coherence elastography for measuring material mechanical properties
Liang, X., Orescanin, M., Toohey, K. S., Insana, M. F., & Boppart, S. A. (2009) · Optics Letters · doi:10.1364/ol.34.002894 · Cited by 75 · cited 1×
“This technique may also have the advantage for exciting and studying local biomechanical properties such as in the cancer microenvironment, instead of bulk excitation.(44) OCE measurements deep within human tissues using needle OCE was also demonstrated ex vivo, extending the potential of OCE as a surgical guidance to…”
Self-citationMeasuring airway dimensions during bronchoscopy using anatomical optical coherence tomography
Williamson, J., Armstrong, J. J., McLaughlin, R. A., Noble, P. B., West, A. R., Becker, S., Curatolo, A., Noffsinger, W., Mitchell, H. W., Phillips, M. J., et al. (2009) · European Respiratory Journal · doi:10.1183/09031936.00041809 · Cited by 75 · cited 1×
“81 With the development of anatomical OCT, it was demonstrated that it was possible to record dynamic changes in airway size and shape with OCT 82 – 84 and measure the elastic properties of the central airway in obstructive lung diseases.”
Escobar, P. F., Rojas-Espaillat, L. A., Tisci, S., Enerson, C. L., Brainard, J., Smith, J. S., Tresser, N. J., Feldchtein, F. I., Rojas, L., & Belinson, J. L. (2006) · International Journal of Gynecological Cancer · doi:10.1136/ijgc-00009577-200609000-00015 · Cited by 72
Kiseleva, E. B., Kirillin, M., Feldchtein, F. I., Vitkin, I. A., Sergeeva, E. A., Вадимовна, З. Е., Streltzova, O., Shakhov, B. E., Gubarkova, E. V., & Gladkova, N. D. (2015) · Biomedical Optics Express · doi:10.1364/boe.6.001464 · Cited by 67 · cited 1×
“126,127”
Rajagopalan, U. M., Takaoka, H., Homma, R., Kadono, H., & Tanifuji, M. (2002) · Optics Communications · doi:10.1016/s0030-4018(02)01079-9 · Cited by 62 · cited 1×
“In 2002, the application of OCT for visualizing 1-D depth-resolved functional structures of cat brain was reported in vivo.(71) To test the ability of OCT to detect cancer from noncancer intraoperatively and in vivo, five mice with two different high-grade human brain cancer xenografts were studied.”
BackgroundAutomatic scanning of large tissue areas in neurosurgery using optical coherence tomography
Finke, M., Kantelhardt, S. R., Schlaefer, A., Bruder, R., Lankenau, E. M., Giese, A., & Schweikard, A. (2012) · International Journal of Medical Robotics and Computer Assisted Surgery · doi:10.1002/rcs.1425 · Cited by 60 · cited 1×
“68 Imaging ex vivo human brain tissues, the feasibility of using FF-OCT as a label-free nondestructive imaging technique in an intraoperative neurosurgical setting was demonstrated to assess tumorous glial and epileptic margins.”
BackgroundDetection of tumorigenesis in rat bladders with optical coherence tomography
Pan, Y., Lavelle, J. P., Bastacky, S., Meyers, S., Pirtskhalaishvili, G., Zeidel, M. L., & Farkas, D. L. (2001) · Medical Physics · doi:10.1118/1.1418726 · Cited by 60 · cited 2×
“, papillary hyperplasia and carcinomas).(113) A comparative study was conducted between OCT and 40-MHz high-frequency ultrasound (HFUS) for imaging rat bladder cancer ex vivo, and the study suggested that multimodality cystoscopy combining OCT and HFUS may have the potential to enhance the diagnosis and staging of bla…”
BackgroundHermes, B., Spöler, F., Naami, A., Bornemann, J., Först, M., Grosse, J. O., Jakse, G., & Knüchel, R. (2008) · Urology · doi:10.1016/j.urology.2008.02.062 · Cited by 60 · cited 1×
“the existence of the BM zone allowed for reliable exclusion of bladder tumor invasion.(117)”
BackgroundComputational optical coherence tomography [Invited]
Liu, Y.-Z., South, F. A., Xu, Y., Carney, P. S., & Boppart, S. A. (2017) · Biomedical Optics Express · doi:10.1364/boe.8.001549 · Cited by 58
Self-citationIftimia, N. V., Iyer, A. K., Hammer, D. X., Lue, N., Mujat, M., Pitman, M. B., Ferguson, R. D., & Amiji, M. M. (2011) · Biomedical Optics Express · doi:10.1364/boe.3.000178 · Cited by 58 · cited 3×
“96 In contrast, the OCT images of the ApcMin mice that developed colonic adenomas showed changes in the morphology of the mucosal layer.”
BackgroundMethodInfluentialGladkova, N. D., Streltsova, O. S., Вадимовна, З. Е., Kiseleva, E. B., Gelikonov, V. M., Gelikonov, G. V., Karabut, M. M., Эдуардовна, Ю. К., & Ливерьевна, Е. О. (2010) · Journal of Biophotonics · doi:10.1002/jbio.201000088 · Cited by 52
Hsiung, P.-L., Pantanowitz, L., Aguirre, A. D., Chen, Y., Phatak, D. R., Ko, T. H., Bourquin, S., Schnitt, S. J., Raza, S., Connolly, J. L., et al. (2005) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2005.05.006 · Cited by 52 · cited 3×
“93 With ultrahigh-resolution OCT, it was possible to distinguish the epithelial layer of the mucosa and visualize individual villi, glands, and crypts.”
BackgroundMethodFractal analysis for classification of breast carcinoma in optical coherence tomography
Sullivan, A. C., Hunt, J. P., & Oldenburg, A. L. (2011) · Journal of Biomedical Optics · doi:10.1117/1.3590746 · Cited by 49 · cited 1×
“58 In parallel, fractal analysis was proposed for classification of breast carcinoma using OCT 59 while an automated algorithm for differentiating adipose tissue from fibro-glandular human breast tissue based on parameters computed from the LCI signal (slope, standard deviation, and spatial…”
MethodTargeted Multifunctional Multimodal Protein-Shell Microspheres as Cancer Imaging Contrast Agents
John, R., Nguyen, F. T., Kolbeck, K. J., Chaney, E. J., Marjanović, M., Suslick, K. S., & Boppart, S. A. (2011) · Molecular Imaging and Biology · doi:10.1007/s11307-011-0473-7 · Cited by 48
Self-citationBizheva, K. K., Unterhuber, A., Hermann, B. M., Považay, B., Sattmann, H., Drexler, W., Stingl, A., Le, T. M., Mei, M., Holzwarth, R., et al. (2004) · Journal of Biomedical Optics · doi:10.1117/1.1756920 · Cited by 48 · cited 1×
“, bee, rabbit, and monkey) both ex vivo and in vitro.(63) Acquiring images of a fixed rabbit brain slice, as one example, OCT clearly demonstrated the difference in optical scattering properties between gray and white brain matter, resulting in varying image depth penetration in the OCT images.”
BackgroundComputed optical interferometric tomography for high-speed volumetric cellular imaging
Liu, Y.-Z., Shemonski, N. D., Adie, S. G., Ahmad, A., Bower, A. J., Carney, P. S., & Boppart, S. A. (2014) · Biomedical Optics Express · doi:10.1364/boe.5.002988 · Cited by 45 · cited 2×
“OCT is a good modality for 3-D culture studies as it enables continuous monitoring of the spatiotemporal dynamics in nonperturbative and nondestructive ways.(23) OCT has been used to quantitatively monitor tumor burden in vitro throughout the course of PDT by mapping the volumes of individual 3-D tumors.”
BackgroundMethodSelf-citationExtended depth of focus adaptive optics spectral domain optical coherence tomography
Sasaki, K., Kurokawa, K., Makita, S., & Yasuno, Y. (2012) · Biomedical Optics Express · doi:10.1364/boe.3.002353 · Cited by 44
Anatomical Optical Coherence Tomography for Long-Term, Portable, Quantitative Endoscopy
Leigh, M. S., Armstrong, J. J., Paduch, A., Walsh, J. H., Hillman, D. R., Eastwood, P. R., & Sampson, D. D. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.913409 · Cited by 40 · cited 1×
“81 With the development of anatomical OCT, it was demonstrated that it was possible to record dynamic changes in airway size and shape with OCT 82 – 84 and measure the elastic properties of the central airway in obstructive lung diseases.”
Srivastava, A., Verma, Y., Rao, K. D., & Gupta, P. K. (2009) · Strain · doi:10.1111/j.1475-1305.2009.00627.x · Cited by 37
Chhetri, R. K., Phillips, Z. F., Troester, M. A., & Oldenburg, A. L. (2012) · PLoS ONE · doi:10.1371/journal.pone.0049148 · Cited by 36 · cited 2×
“For instance, OCT has been used to monitor the ratio of fibroblasts to mammary epithelial cells, which is instrumental in determining organoid phenotypes.(24) Further study adapted the principles of dynamic light scattering to OCT to monitor the dynamics of intracellular motions of different cells (i.”
BackgroundMethodJohn, R., Adie, S. G., Chaney, E. J., Marjanović, M., Tangella, K. V., & Boppart, S. A. (2012) · Annals of Surgical Oncology · doi:10.1245/s10434-012-2434-z · Cited by 33 · cited 2×
“Recently, intraoperative 3-D OCT for assessing human lymph nodes for metastatic cancer was demonstrated.(55) To further improve the image contrast between malignant and healthy nonneoplastic tissue in OCT images, parametric imaging of the local attenuation coefficient in human axillary lymph nodes was assessed using O…”
BackgroundMethodSelf-citationJung, Y., Klein, O. J., Wang, H., & Evans, C. L. (2016) · Scientific Reports · doi:10.1038/srep27017 · Cited by 32 · cited 19×
“94 OCM enabled cellular imaging of specimens from the upper and lower gastro-intestinal tracts over a smaller field of view, compared with OCT. Squamous cells and their nuclei, goblet cells in Barrett ’ s esophagus, gastric pits and colonic crypts, and fine structures in adenocarcinomas were all visualized.”
MethodResultInfluentialIn vitro ovarian tumor growth and treatment response dynamics visualized with time-lapse OCT imaging
Evans, C. L., Rizvi, I., Hasan, T. G., & de Boer, J. F. (2009) · Optics Express · doi:10.1364/oe.17.008892 · Cited by 32 · cited 2×
“For example, TL-OCT was used to investigate the therapeutic response of ovarian cancer nodules to cisplatin: a front-line agent for the treatment of ovarian cancer.(164)”
BackgroundMethodHuang, P., Pande, P., Ahmad, A., Marjanović, M., Spillman, D. R., Odintsov, B. M., & Boppart, S. A. (2015) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/jstqe.2015.2505147 · Cited by 27
Self-citationLabel‐Free, Longitudinal Visualization of PDT Response In Vitro with Optical Coherence Tomography
Jung, Y., Nichols, A. J., Klein, O. J., Roussakis, E., & Evans, C. L. (2012) · Israel Journal of Chemistry · doi:10.1002/ijch.201200009 · Cited by 20 · cited 1×
“164,165 The capability of OCT to monitor a therapeutic response was also demonstrated in a mouse model.”
BackgroundKlein, O. J., Jung, Y., & Evans, C. L. (2013) · Methods · doi:10.1016/j.ymeth.2013.08.028 · Cited by 14 · cited 2×
“160 With OCT, it was also possible to visualize the progression of apoptosis in vitro without labels via the elevated light scattering caused by chromatin condensation.”
Background
Cited by
Paracentral acute middle maculopathy and the organization of the retinal capillary plexuses
Scharf, J., Freund, K. B., Sadda, S., & Sarraf, D. (2021) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2020.100884 · Cited by 177
Metadata
- Authors
- Wang, J., Xu, Y., & Boppart, S. A.
- Venue
- Journal of Biomedical Optics
- Publisher
- SPIE-Intl Soc Optical Eng
- Published
- 2017-12-22
- Volume
- 22
- Issue
- 12
- Pages
- 1
- ISSN
- 1083-3668 (ISSN-L)
- OpenAlex
- W2776344324
- Cited by
- 172
- References
- 103
- FWCI
- 4.89
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.