CoChat

Battery-free, fully implantable optofluidic cuff system for wireless optogenetic and pharmacological neuromodulation of peripheral nerves

Open access

The DOI matches its Crossref record; 50 of the 52 references it cites were found in a registry or an index.

Abstract

A battery-free, soft implantable nerve cuff system provides wireless delivery of light and drugs to modulate nerve activity.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1126/sciadv.aaw5296

Cites

50 of 50 references verified0 citation errors · 0 not checkable

Statistics

Figures

Fig. 1 Wireless, battery-free neural cuff for programmable pharmacology and optogenetics. (A and B) Demonstrations of the overall size of the system. Scale bars, 5 mm. (C and D) Magnified views of the neural cuff interface with optical μ-ILED activation and fluid delivery. Scale bars, 1 mm. Exploded view (E) and electrical schematic diagram (F) of the wireless optofluidic system for programmable pharmacology and optogenetics. μC, microcontroller.
Fig. 1 Wireless, battery-free neural cuff for programmable pharmacology and optogenetics. (A and B) Demonstrations of the overall size of the system. Scale bars, 5 mm. (C and D) Magnified views of the neural cuff interface with optical μ-ILED activation and fluid delivery. Scale bars, 1 mm. Exploded view (E) and electrical schematic diagram (F) of the wireless optofluidic system for programmable pharmacology and optogenetics. μC, microcontroller.CC BY-NC · PubMed Central
Fig. 2 Fluidic and electrical characteristics of the wireless optofluidic system. (A and B) Top: Schematic diagram of the electrochemical micropump. Applying current to a pair of electrodes initiates pumping through expansion induced by electrochemical phase change of liquid water into hydrogen and oxygen gases. The resulting pressure in the micropump chamber deforms the flexible membrane and delivers the drug. Bottom: Images of mechanical deformation of the flexible membrane induced by water electrolysis. Scale bar, 0.3 mm. (C) Fluid volume in the drug reservoir as a function of time. (D) Comparison between experiment and modeling of maximum displacement of flexible membrane induced by water electrolysis. (E) Current-voltage-power characteristics of the electrochemical micropump. (F) Total infusion efficiency from various loaded volumes in representative devices (n = 3 devices). (G) Flow rate in a microfluidic channel as a function of time. (H) Temperature of the drug chamber (top) and micropump chamber (bottom) during the electrochemical pumping process (3 V). All data are represented as means ± SEM.
Fig. 2 Fluidic and electrical characteristics of the wireless optofluidic system. (A and B) Top: Schematic diagram of the electrochemical micropump. Applying current to a pair of electrodes initiates pumping through expansion induced by electrochemical phase change of liquid water into hydrogen and oxygen gases. The resulting pressure in the micropump chamber deforms the flexible membrane and delivers the drug. Bottom: Images of mechanical deformation of the flexible membrane induced by water electrolysis. Scale bar, 0.3 mm. (C) Fluid volume in the drug reservoir as a function of time. (D) Comparison between experiment and modeling of maximum displacement of flexible membrane induced by water electrolysis. (E) Current-voltage-power characteristics of the electrochemical micropump. (F) Total infusion efficiency from various loaded volumes in representative devices (n = 3 devices). (G) Flow rate in a microfluidic channel as a function of time. (H) Temperature of the drug chamber (top) and micropump chamber (bottom) during the electrochemical pumping process (3 V). All data are represented as means ± SEM.CC BY-NC · PubMed Central
Fig. 3 Implantation of the battery-free optofluidic nerve cuff system and its impact on animal behavior and nerve health. (A) Detailed illustration of the optofluidic nerve cuff system and cuff interface with the mouse sciatic nerve. (B) Demonstration of both optical stimulation and fluid delivery to the sciatic nerve. Scale bar, 2 mm. (C) Mouse chronically implanted with the wirelessly powered optofluidic nerve cuff system. (D) Characterization of effects of device implantation on rotarod performance compared to PE cuff and sham surgery [n = 9 to 10; ***P < 0.001 PE cuff versus sham and device, two-way analysis of variance (ANOVA)]. Mouse gait parameters including maximum contact mean intensity (E), swing time (F), and print area (G) are significantly impaired after PE cuff implantation but not after optofluidic cuff implantation compared to sham surgery (n = 8 to 10; ***P < 0.001, **P < 0.01, and *P < 0.05, one-way ANOVA with Tukey’s multiple comparison). Representative hematoxylin and eosin images (H) and quantification of infiltrating immune cells (I) from the sciatic nerve comparing sham, device, and PE cuff after 2 weeks (w) of implantation demonstrating an absence of infiltrating immune cells in sciatic nerves of mice implanted with the device compared to PE cuff implantation. Scale bars, 25 μm. n = 3; ***P < 0.001, one-way ANOVA with Tukey’s multiple comparison. AU, arbitrary units.
Fig. 3 Implantation of the battery-free optofluidic nerve cuff system and its impact on animal behavior and nerve health. (A) Detailed illustration of the optofluidic nerve cuff system and cuff interface with the mouse sciatic nerve. (B) Demonstration of both optical stimulation and fluid delivery to the sciatic nerve. Scale bar, 2 mm. (C) Mouse chronically implanted with the wirelessly powered optofluidic nerve cuff system. (D) Characterization of effects of device implantation on rotarod performance compared to PE cuff and sham surgery [n = 9 to 10; ***P < 0.001 PE cuff versus sham and device, two-way analysis of variance (ANOVA)]. Mouse gait parameters including maximum contact mean intensity (E), swing time (F), and print area (G) are significantly impaired after PE cuff implantation but not after optofluidic cuff implantation compared to sham surgery (n = 8 to 10; ***P < 0.001, **P < 0.01, and *P < 0.05, one-way ANOVA with Tukey’s multiple comparison). Representative hematoxylin and eosin images (H) and quantification of infiltrating immune cells (I) from the sciatic nerve comparing sham, device, and PE cuff after 2 weeks (w) of implantation demonstrating an absence of infiltrating immune cells in sciatic nerves of mice implanted with the device compared to PE cuff implantation. Scale bars, 25 μm. n = 3; ***P < 0.001, one-way ANOVA with Tukey’s multiple comparison. AU, arbitrary units.CC BY-NC · PubMed Central
Fig. 4 Demonstration of optogenetic and microfluidic capabilities of the wireless, battery-free optofluidic nerve cuff system. (A) Schematic of the real-time place preference assay designed to test the capabilities of nerve cuff optical stimulation. Representative heat maps (B) and quantification (C) of blue light stimulation of sciatic nerve in wild-type and TRPV1-ChR2 mice. Mice were placed in the chamber for a total of 20 min. TRPV1-ChR2 mice displayed significant aversion to 1-Hz light pulse stimulus compared to wild-type mice (n = 9 to 10; *P < 0.05, two-way ANOVA with Sidak’s multiple comparisons test). (D) Optofluidic cuff devices loaded with bupivacaine and saline were implanted in mice, and thermal sensitivity was assayed before and after saline and again after bupivacaine infusion. (E) Quantification of the withdrawal latency to thermal stimulation of the ipsilateral (device side) and contralateral paw at baseline, after saline and after bupivacaine (n = 5 to 6; *P < 0.05 and **P < 0.01, one-way ANOVA with Sidak’s multiple comparisons test).
Fig. 4 Demonstration of optogenetic and microfluidic capabilities of the wireless, battery-free optofluidic nerve cuff system. (A) Schematic of the real-time place preference assay designed to test the capabilities of nerve cuff optical stimulation. Representative heat maps (B) and quantification (C) of blue light stimulation of sciatic nerve in wild-type and TRPV1-ChR2 mice. Mice were placed in the chamber for a total of 20 min. TRPV1-ChR2 mice displayed significant aversion to 1-Hz light pulse stimulus compared to wild-type mice (n = 9 to 10; *P < 0.05, two-way ANOVA with Sidak’s multiple comparisons test). (D) Optofluidic cuff devices loaded with bupivacaine and saline were implanted in mice, and thermal sensitivity was assayed before and after saline and again after bupivacaine infusion. (E) Quantification of the withdrawal latency to thermal stimulation of the ipsilateral (device side) and contralateral paw at baseline, after saline and after bupivacaine (n = 5 to 6; *P < 0.05 and **P < 0.01, one-way ANOVA with Sidak’s multiple comparisons test).CC BY-NC · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 195

Metadata

Authors
Zhang, Y., Mickle, A. D., Gutruf, P., McIlvried, L. A., Guo, H., Wu, Y., Golden, J. P., Xue, Y., Grajales-Reyes, J. G., Wang, X., Krishnan, S., Xie, Y., Peng, D., Su, C.-J., Zhang, F., Reeder, J. T., Vogt, S. K., Huang, Y., Rogers, J. A., & Gereau, R. W.
Affiliations
  • Northwestern University (US)
  • Washington University in St. Louis (US)
  • Washington University Pain Center and Department of Anesthesiology, Washington University, St. Louis, MO 63110, USA.
  • University of Missouri (US)
  • Georgia Institute of Technology (US)
Corresponding author
  • Zhang, Yi
  • Mickle, Aaron D.
  • Gutruf, Philipp
  • McIlvried, Lisa A.
  • Rogers, John A.
  • Gereau, Robert W.
Venue
Science Advances
Published
2019-07-05
Volume
5
Issue
7
Pages
eaaw5296-eaaw5296
ISSN
2375-2548 (ISSN-L)
OpenAlex
W2954955569
Cited by
195
References
52
Citations by year
2026: 15 · 2025: 32 · 2024: 26 · 2023: 25 · 2022: 22 · 2021: 50 · 2020: 20 · 2019: 5
FWCI
11.59
Type
journal article
Language
en
Open access
Licence
cc-by-nc
Locations
  • Science Advances (publishedVersion, cc-by-nc)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by-nc)
  • PubMed Central (publishedVersion, cc-by-nc)
  • PubMed (publishedVersion)
  • UA Campus Repository (The University of Arizona) (acceptedVersion, cc-by-nc)
  • Digital Commons@Becker (Washington University School of Medicine) (submittedVersion, cc-by-nc)
Funders
  • National Institute of Mental Health (R41MH116525)
  • National Institute on Drug Abuse (DA007261)
  • National Institute of General Medical Sciences (GM07200)
  • National Institute of Diabetes and Digestive and Kidney Diseases (DK115122)
  • National Institute of Neurological Disorders and Stroke (NS081707, NS103472, NS42595)
  • National Institute of Biomedical Imaging and Bioengineering (EB021793)
Topics
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Life Sciences › Neuroscience › Neurology › Vagus Nerve Stimulation Research
  • Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
Keywords
optogenetics, neuromodulation, peripheral nerves, biomedical implants, battery-free devices, wireless stimulation, microfluidic drug delivery, chronic implantation, freely moving animals
MeSH terms
Animals, Brain, Humans, Peripheral Nerves, Neurotransmitter Agents, Prostheses and Implants, Mice, Wireless Technology, Optogenetics

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.