"Plugging into Enzymes": Nanowiring of Redox Enzymes by a Gold Nanoparticle
Abstract
The reconstitution of an apo-flavoenzyme, apo–glucose oxidase, on a 1.4-nanometer gold nanocrystal functionalized with the cofactor flavin adenine dinucleotide and integrated into a conductive film yields a bioelectrocatalytic system with exceptional electrical contact with the electrode support. The electron transfer turnover rate of the reconstituted bioelectrocatalyst is ∼5000 per second, compared with the rate at which molecular oxygen, the natural cosubstrate of the enzyme, accepts electrons (∼700 per second). The gold nanoparticle acts as an electron relay or “electrical nanoplug” for the alignment of the enzyme on the conductive support and for the electrical wiring of its redox-active center.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Laviron, E. (1979) · Journal of Electroanalytical Chemistry and Interfacial Electrochemistry · doi:10.1016/s0022-0728(79)80075-3 · Cited by 7,234
Application of conducting polymers to biosensors
Gerard, M. (2002) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(01)00312-8 · Cited by 1,652
Integration of Layered Redox Proteins and Conductive Supports for Bioelectronic Applications
Willner, I., & Katz, E. (2000) · Angewandte Chemie International Edition · doi:10.1002/(sici)1521-3773(20000403)39:7<1180::aid-anie1180>3.0.co;2-e · Cited by 950
Self-citationElectrical wiring of redox enzymes
Heller, A. (1990) · Accounts of Chemical Research · doi:10.1021/ar00173a002 · Cited by 788
Electrical connection of enzyme redox centers to electrodes
Heller, A. (1992) · The Journal of Physical Chemistry · doi:10.1021/j100188a007 · Cited by 603
Degani, Y., & Heller, A. (1987) · The Journal of Physical Chemistry · doi:10.1021/j100290a001 · Cited by 574
Recent developments in faradaic bioelectrochemistry
Armstrong, F. A., & Wilson, G. S. (2000) · Electrochimica Acta · doi:10.1016/s0013-4686(00)00342-x · Cited by 446
Willner, I., Heleg-Shabtai, V., Blonder, R., Katz, E., Tao, G., Bückmann, A. F., & Heller, A. (1996) · Journal of the American Chemical Society · doi:10.1021/ja9608611 · Cited by 370
Self-citationSchuhmann, W., Ohara, T. J., Schmidt, H. L., & Heller, A. (1991) · Journal of the American Chemical Society · doi:10.1021/ja00004a048 · Cited by 348
Raitman, O. A., Katz, E., Bückmann, A. F., & Willner, I. (2002) · Journal of the American Chemical Society · doi:10.1021/ja012680r · Cited by 263
Self-citation
Cited by
Gold Nanoparticles in Chemical and Biological Sensing
Saha, K., Agasti, S. S., Kim, C., Li, X., & Rotello, V. M. (2012) · Chemical Reviews · doi:10.1021/cr2001178 · Cited by 4,620
Electrochemical Glucose Biosensors
Wang, J. (2008) · Chemical Reviews · doi:10.1021/cr068123a · Cited by 3,498
Gold nanoparticles in nanomedicine: preparations, imaging, diagnostics, therapies and toxicity
Boisselier, E., & Astruc, D. (2009) · Chemical Society Reviews · doi:10.1039/b806051g · Cited by 2,842
Integrated Nanoparticle–Biomolecule Hybrid Systems: Synthesis, Properties, and Applications
Katz, E., & Willner, I. (2004) · Angewandte Chemie International Edition · doi:10.1002/anie.200400651 · Cited by 2,450
Self-citationGold Nanoparticles for Biology and Medicine
Giljohann, D. A., Seferos, D. S., Daniel, W. L., Massich, M. D., Patel, P. C., & Mirkin, C. A. (2010) · Angewandte Chemie International Edition · doi:10.1002/anie.200904359 · Cited by 2,356
Electrochemical Biosensors - Sensor Principles and Architectures
Grieshaber, D., MacKenzie, R., Vörös, J., & Reimhult, E. (2008) · Sensors · doi:10.3390/s80314000 · Cited by 2,329
Biological applications of gold nanoparticles
Sperling, R. A., Rivera Gil, P., Zhang, F., Zanella, M., & Parak, W. J. (2008) · Chemical Society Reviews · doi:10.1039/b712170a · Cited by 1,799
Electrochemical Glucose Sensors and Their Applications in Diabetes Management
Heller, A., & Feldman, B. (2008) · Chemical Reviews · doi:10.1021/cr068069y · Cited by 1,707
Properties and emerging applications of self-assembled structures made from inorganic nanoparticles
Nie, Z., Petukhova, A., & Kumacheva, E. (2010) · Nature Nanotechnology · doi:10.1038/nnano.2009.453 · Cited by 1,598
Applications of Nanoparticles in Biology
De, M., Ghosh, P. S., & Rotello, V. M. (2008) · Advanced Materials · doi:10.1002/adma.200703183 · Cited by 1,547
Sapsford, K. E., Algar, W. R., Berti, L., Gemmill, K. B., Casey, B. J., Oh, E., Stewart, M. H., & Medintz, I. L. (2013) · Chemical Reviews · doi:10.1021/cr300143v · Cited by 1,423
Gold nanoparticles: preparation, properties, and applications in bionanotechnology
Yeh, Y.-C., Creran, B., & Rotello, V. M. (2012) · Nanoscale · doi:10.1039/c1nr11188d · Cited by 1,346
Recent advances in graphene-based biosensors
Kuila, T., Bose, S., Khanra, P., Mishra, A. K., Kim, N. H., & Lee, J. H. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2011.05.039 · Cited by 1,329
Application of Nanoparticles in Electrochemical Sensors and Biosensors
Luo, X., Morrin, A., Killard, A. J., & Smyth, M. R. (2006) · Electroanalysis · doi:10.1002/elan.200503415 · Cited by 1,318
Electrocatalysis as an enabling technology for organic synthesis
Novaes, L. F. T., Liu, J., Shen, Y., Lu, L., Meinhardt, J. M., & Lin, S. (2021) · Chemical Society Reviews · doi:10.1039/d1cs00223f · Cited by 1,278
Potential applications of enzymes immobilized on/in nano materials: A review
Ansari, S. A., & Husain, Q. (2012) · Biotechnology Advances · doi:10.1016/j.biotechadv.2011.09.005 · Cited by 1,118
Nanomaterials for biosensing applications: a review
Holzinger, M., Le Goff, A., & Cosnier, S. (2014) · Frontiers in Chemistry · doi:10.3389/fchem.2014.00063 · Cited by 1,066
Enzymes as Working or Inspirational Electrocatalysts for Fuel Cells and Electrolysis
Cracknell, J. A., Vincent, K. A., & Armstrong, F. A. (2008) · Chemical Reviews · doi:10.1021/cr0680639 · Cited by 988
Gold nanoparticle-based electrochemical biosensors
Pingarrón, J. M., Yáñez-Sedeño, P., & González-Cortés, A. (2008) · Electrochimica Acta · doi:10.1016/j.electacta.2008.03.005 · Cited by 965
Electron microscopy of specimens in liquid
de Jonge, N., & Ross, F. M. (2011) · Nature Nanotechnology · doi:10.1038/nnano.2011.161 · Cited by 952
Gold Nanoparticles for In Vitro Diagnostics
Zhou, W., Gao, X., Liu, D., & Chen, X. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00100 · Cited by 901
Recent advances in electrochemical glucose biosensors: a review
Chen, C., Xie, Q., Yang, D., Xiao, H., Fu, Y., Tan, Y., & Yao, S. (2013) · RSC Advances · doi:10.1039/c2ra22351a · Cited by 807
A review on graphene-based nanocomposites for electrochemical and fluorescent biosensors
Krishnan, S. K., Singh, E., Singh, P., Meyyappan, M., & Nalwa, H. S. (2019) · RSC Advances · doi:10.1039/c8ra09577a · Cited by 785
Direct Electrochemistry of Redox Enzymes as a Tool for Mechanistic Studies
Léger, C., & Bertrand, P. (2008) · Chemical Reviews · doi:10.1021/cr0680742 · Cited by 783
A Comprehensive Review of Glucose Biosensors Based on Nanostructured Metal-Oxides
Rahman, M. M., Ahammad, A. J. S., Jin, J.-H., Ahn, S. J., & Lee, J.-J. (2010) · Sensors · doi:10.3390/s100504855 · Cited by 762
“The improved sensing performance by the direct electron transfer has been realized by incorporating the enzyme with metal nanoparticles [64,65], and semiconductive nanomaterials [66,67].”
MethodCatechol‐Based Biomimetic Functional Materials
Sedó, J., Saiz‐Poseu, J., Busqué, F., & Ruiz‐Molina, D. (2013) · Advanced Materials · doi:10.1002/adma.201202343 · Cited by 752
Biomolecule‐Functionalized Carbon Nanotubes: Applications in Nanobioelectronics
Katz, E., & Willner, I. (2004) · ChemPhysChem · doi:10.1002/cphc.200400193 · Cited by 749
Self-citationElectroanalytical and Bioelectroanalytical Systems Based on Metal and Semiconductor Nanoparticles
Katz, E., Willner, I., & Wang, J. (2004) · Electroanalysis · doi:10.1002/elan.200302930 · Cited by 738
Self-citationYin, P. T., Shah, S., Chhowalla, M., & Lee, K.-B. (2015) · Chemical Reviews · doi:10.1021/cr500537t · Cited by 718
Graphene: Promises, Facts, Opportunities, and Challenges in Nanomedicine
Mao, H. Y., Laurent, S., Chen, W., Akhavan, O., Imani, M., Ashkarran, A. A., & Mahmoudi, M. (2013) · Chemical Reviews · doi:10.1021/cr300335p · Cited by 701
Wongkaew, N., Simsek, M., Griesche, C., & Baeumner, A. J. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00172 · Cited by 657
Self-Catalyzed, Self-Limiting Growth of Glucose Oxidase-Mimicking Gold Nanoparticles
Luo, W., Zhu, C., Su, S., Li, D., He, Y., Huang, Q., & Fan, C. (2010) · ACS Nano · doi:10.1021/nn102592h · Cited by 650
Carbon nanotubes for biological and biomedical applications
Yang, W., Thordarson, P., Gooding, J. J., Ringer, S. P., & Braet, F. (2007) · Nanotechnology · doi:10.1088/0957-4484/18/41/412001 · Cited by 648
Long‐Range Electrical Contacting of Redox Enzymes by SWCNT Connectors
Patolsky, F., Weizmann, Y., & Willner, I. (2004) · Angewandte Chemie International Edition · doi:10.1002/anie.200353275 · Cited by 609
Self-citationSignal amplification using functional nanomaterials for biosensing
Lei, J., & Ju, H. (2012) · Chemical Society Reviews · doi:10.1039/c1cs15274b · Cited by 588
Challenges in biocatalysis for enzyme-based biofuel cells
Kim, J., Jia, H., & Wang, P. (2006) · Biotechnology Advances · doi:10.1016/j.biotechadv.2005.11.006 · Cited by 554
Liu, Y., Wang, M., Zhao, F., Xu, Z., & Dong, S. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2005.03.003 · Cited by 552
Polyvalent DNA Nanoparticle Conjugates Stabilize Nucleic Acids
Seferos, D. S., Prigodich, A. E., Giljohann, D. A., Patel, P. C., & Mirkin, C. A. (2009) · Nano Letters · doi:10.1021/nl802958f · Cited by 551
Mani, V., Chikkaveeraiah, B. V., Patel, V., Gutkind, J. S., & Rusling, J. F. (2009) · ACS Nano · doi:10.1021/nn800863w · Cited by 532
Gooding, J. J., & Ciampi, S. (2011) · Chemical Society Reviews · doi:10.1039/c0cs00139b · Cited by 524
Penn, S. G., He, L., & Natan, M. J. (2003) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2003.08.013 · Cited by 512
Charge Transport in Nanoparticle Assemblies
Zabet-Khosousi, A., & Dhirani, A.-A. (2008) · Chemical Reviews · doi:10.1021/cr0680134 · Cited by 503
Putzbach, W., & Ronkainen, N. (2013) · Sensors · doi:10.3390/s130404811 · Cited by 502
Electrochemical nanobiosensors
Pumera, M., Sánchez, S., Ichinose, I., & Tang, J. (2007) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2006.11.016 · Cited by 495
Fundamentals, Applications, and Future Directions of Bioelectrocatalysis
Chen, H., Simoska, O., Lim, K., Grattieri, M., Yuan, M., Dong, F., Lee, Y. S., Beaver, K., Weliwatte, S., Gaffney, E. M., et al. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.0c00472 · Cited by 492
Advances in the field of π-conjugated 2,2′:6′,2″-terpyridines
Wild, A., Winter, A., Schlütter, F., & Schubert, U. S. (2011) · Chem. Soc. Rev. · doi:10.1039/c0cs00074d · Cited by 482
“Clicking” Functionality onto Electrode Surfaces
Collman, J. P., Devaraj, N. K., & Chidsey, C. E. D. (2004) · Langmuir · doi:10.1021/la0362977 · Cited by 479
Diverse gatekeepers for mesoporous silica nanoparticle based drug delivery systems
Wen, J., Yang, K., Liu, F., Li, H., Xu, Y., & Sun, S. (2017) · Chemical Society Reviews · doi:10.1039/c7cs00219j · Cited by 477
Virkutyte, J., & Varma, R. S. (2011) · Chem. Sci. · doi:10.1039/c0sc00338g · Cited by 462
Expanding the Optical Trapping Range of Gold Nanoparticles
Hansen, P. M., Bhatia, V. K., Harrit, N., & Oddershede, L. (2005) · Nano Letters · doi:10.1021/nl051289r · Cited by 452
New Nanostructured TiO2 for Direct Electrochemistry and Glucose Sensor Applications
Bao, S., Li, C. M., Zang, J., Cui, X., Qiao, Y., & Guo, J. (2008) · Advanced Functional Materials · doi:10.1002/adfm.200700728 · Cited by 446
Electrochemical biosensors and nanobiosensors
Hammond, J. L., Formisano, N., Estrela, P., Carrara, S., & Tkac, J. (2016) · Essays in Biochemistry · doi:10.1042/ebc20150008 · Cited by 425
Nanostructured Electrochemical Sensor Based on Dense Gold Nanoparticle Films
Yu, A., Liang, Z., Cho, J., & Caruso, F. (2003) · Nano Letters · doi:10.1021/nl034363j · Cited by 414
Aptamer Nano-flares for Molecular Detection in Living Cells
Zheng, D., Seferos, D. S., Giljohann, D. A., Patel, P. C., & Mirkin, C. A. (2009) · Nano Letters · doi:10.1021/nl901517b · Cited by 401
Enzyme catalysed biofuel cells
Cooney, M. J., Svoboda, V., Lau, C., Martin, G., & Minteer, S. D. (2008) · Energy & Environmental Science · doi:10.1039/b809009b · Cited by 391
Integrated Enzyme‐Based Biofuel Cells–A Review
Willner, I., Yan, Y. ‐., Willner, B., & Tel‐Vered, R. (2009) · Fuel Cells · doi:10.1002/fuce.200800115 · Cited by 378
Self-citationBaron, R., Zayats, M., & Willner, I. (2005) · Analytical Chemistry · doi:10.1021/ac048691v · Cited by 373
Self-citationNanomaterials for electrochemical non-enzymatic glucose biosensors
Si, P., Huang, Y., Wang, T., & Ma, J. (2013) · RSC Advances · doi:10.1039/c2ra22360k · Cited by 364
Nanosensors in environmental analysis
RIU, J., MAROTO, A., & RIUS, F. (2006) · Talanta · doi:10.1016/j.talanta.2005.09.045 · Cited by 363
Catalytic Gold Nanoparticles for Nanoplasmonic Detection of DNA Hybridization
Zheng, X., Liu, Q., Jing, C., Li, Y., Li, D., Luo, W., Wen, Y., He, Y., Huang, Q., Long, Y., et al. (2011) · Angewandte Chemie International Edition · doi:10.1002/anie.201105121 · Cited by 348
Synthetic Tuning of the Catalytic Properties of Au‐Fe3O4 Nanoparticles
Lee, Y., Garcia, M. A., Frey Huls, N. A., & Sun, S. (2010) · Angewandte Chemie International Edition · doi:10.1002/anie.200906130 · Cited by 330
Nanostructured material-based biofuel cells: recent advances and future prospects
Zhao, C.-E., Gai, P., Song, R., Chen, Y., Zhang, J., & Zhu, J.-J. (2017) · Chemical Society Reviews · doi:10.1039/c6cs00044d · Cited by 324
Integrated nanoparticle–biomolecule systems for biosensing and bioelectronics
Willner, I., Baron, R., & Willner, B. (2007) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2006.09.018 · Cited by 312
Self-citationFritea, L., Banica, F., Costea, T., Moldovan, L., Dobjanschi, L., Muresan, M., & Cavalu, S. (2021) · Materials · doi:10.3390/ma14216319 · Cited by 311
Liu, J., Chou, A., Rahmat, W., Paddon‐Row, M. N., & Gooding, J. J. (2005) · Electroanalysis · doi:10.1002/elan.200403116 · Cited by 307
Biomolecule-Based Nanomaterials and Nanostructures
Willner, I., & Willner, B. (2010) · Nano Letters · doi:10.1021/nl102083j · Cited by 290
Self-citationSingle-Molecule Electron Transfer in Electrochemical Environments
Zhang, J., Kuznetsov, A. M., Medvedev, I. G., Chi, Q., Albrecht, T., Jensen, P. S., & Ulstrup, J. (2008) · Chemical Reviews · doi:10.1021/cr068073+ · Cited by 290
Wang, P. (2006) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2006.10.009 · Cited by 284
Electrochemical Reduction of CO2 at Functionalized Au Electrodes
Fang, Y., & Flake, J. C. (2017) · Journal of the American Chemical Society · doi:10.1021/jacs.6b11023 · Cited by 278
Shen, J., Li, Y., Gu, H., Xia, F., & Zuo, X. (2014) · Chemical Reviews · doi:10.1021/cr300248x · Cited by 273
Electrochemical Deposition of Nanomaterials for Electrochemical Sensing
Tonelli, D., Scavetta, E., & Gualandi, I. (2019) · Sensors · doi:10.3390/s19051186 · Cited by 264
Structure and function of nanoparticle–protein conjugates
Aubin-Tam, M.-E., & Hamad-Schifferli, K. (2008) · Biomedical Materials · doi:10.1088/1748-6041/3/3/034001 · Cited by 264
Integrated photosystem II-based photo-bioelectrochemical cells
Yehezkeli, O., Tel-Vered, R., Wasserman, J., Trifonov, A., Michaeli, D., Nechushtai, R., & Willner, I. (2012) · Nature Communications · doi:10.1038/ncomms1741 · Cited by 263
Self-citationKatz, E., & Willner, I. (2004) · Angewandte Chemie · doi:10.1002/ange.200400651 · Cited by 260
Self-citationEnzyme‐Free Amperometric Sensing of Glucose by Using Gold Nanoparticles
Jena, B. K., & Raj, C. R. (2006) · Chemistry – A European Journal · doi:10.1002/chem.200501051 · Cited by 259
Recent progress and continuing challenges in bio-fuel cells. Part I: Enzymatic cells
Osman, M. H., Shah, A. A., & Walsh, F. C. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2011.01.004 · Cited by 257
Abad, J. M., Mertens, S. F. L., Pita, M., Fernández, V. M., & Schiffrin, D. J. (2005) · Journal of the American Chemical Society · doi:10.1021/ja042717i · Cited by 256
Electrochemical sensors based on metal and semiconductor nanoparticles
Wang, F., & Hu, S. (2009) · Microchimica Acta · doi:10.1007/s00604-009-0136-4 · Cited by 255
Flexible Plasmonic Biosensors for Healthcare Monitoring: Progress and Prospects
Song, L., Chen, J., Xu, B. B., & Huang, Y. (2021) · ACS Nano · doi:10.1021/acsnano.1c07176 · Cited by 186
Metadata
- Authors
- Xiao, Y., Patolsky, F., Katz, E., Hainfeld, J. F., & Willner, I.
- Venue
- Science
- Published
- 2003-03-21
- Volume
- 299
- Issue
- 5614
- Pages
- 1877-1881
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W2059559745
- Cited by
- 1,270
- References
- 14
- FWCI
- 66.37
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.