An Atomic Clock with 10 –18 Instability
Open accessThe DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
Tick, Tick, Tick…: Many aspects of everyday life from communication to navigation rely on the precise ticking of the microwave transitions of the atoms in atomic clocks. Optical transitions occur at much higher frequency and so offer the opportunity to reduce the scale of the ticks even more. Hinkley et al. (p. 1215 , published online 22 August; see the Perspective by Margolis ) compare the ticking of two optical clocks and report an instability near the 10 −18 level. Such performance will improve tests of general relativity and pave the way for a redefinition of the second.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The frequency stability and uncertainty of the latest generation of optical atomic clocks is now approaching the one part in 10 18 level.”
From Geodetic methods to determine the relativistic redshift at the level of 10 $$^{-18}$$ - 18 in the context of international timescales: a review and practical results (2018) · cites this paper as Hinkley et al. 2013
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The optical clocks operate at frequencies about five orders of magnitude higher than the caesium clocks and thus achieve a higher frequency stability, approaching fractional stabilities and uncertainties of one part in 10 18 (Chou et al. 2010;Hinkley et al. 2013;Bloom et al. 2014;Nicholson et al. 2015;Ushijima et al. 2015;Huntemann et al. 2016).”
From Geodetic methods to determine the relativistic redshift at the level of 10 $$^{-18}$$ - 18 in the context of international timescales: a review and practical results (2018) · cites this paper as Hinkley et al. 2013
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“To date, the best of these instruments reach a stability of 1 . 6 × 10 -18 (NIST, RIKEN + Univ. Tokyo, Hinkley et al. 2013) after 7 hours of integration time.”
From Determination of a high spatial resolution geopotential model using atomic clock comparisons (2017) · cites this paper as Hinkley et al. 2013
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“Optical clocks are—due to their orders of magnitude better precision1 and accuracy234 than their microwave counterparts realizing the definition of the SI-second—new sensors with highest resolving power”
From A clock network for geodesy and fundamental science (2016) · cites this paper as [1]
The cited source says what the claim attributes to it.
In the citing paper
“This demonstrates that use of a state-of-the-art OLO affords unprecedented optical clock stability 10-15 .”
From Ultrastable optical clock with two cold-atom ensembles (2017) · cites this paper as [11]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Frequency Ratio of Al+and Hg+Single-Ion Optical Clocks; Metrology at the 17th Decimal Place
Rosenband, T., Hume, D. B., Schmidt, P. O., Chou, C. W., Brusch, A., Lorini, L., Oskay, W. H., Drullinger, R. E., Fortier, T. M., Stalnaker, J. E., et al. (2008) · Science · doi:10.1126/science.1154622 · Cited by 1,450
Frequency Comparison of Two High-Accuracy Al + Optical Clocks
Chou, C., Hume, D., Koelemeij, J., Wineland, D., & Rosenband, T. (2010) · Physical Review Letters · doi:10.1103/physrevlett.104.070802 · Cited by 903
Chou, C. W., Hume, D. B., Rosenband, T., & Wineland, D. J. (2010) · Science · doi:10.1126/science.1192720 · Cited by 828
A sub-40-mHz-linewidth laser based on a silicon single-crystal optical cavity
Kessler, T., Hagemann, C., Grebing, C., Legero, T., Sterr, U., Riehle, F., Martin, M. J., Chen, L., & Ye, J. (2012) · Nature Photonics · doi:10.1038/nphoton.2012.217 · Cited by 754
Quantum projection noise: Population fluctuations in two-level systems
Itano, W. M., Bergquist, J. C., Bollinger, J. J., Gilligan, J. M., Heinzen, D. J., Moore, F. L., Raizen, M. G., & Wineland, D. J. (1993) · Physical Review A · doi:10.1103/physreva.47.3554 · Cited by 613
Ultrastable Optical Clock with Neutral Atoms in an Engineered Light Shift Trap
Katori, H., Takamoto, M., Pal’chikov, V. G., & Ovsiannikov, V. D. (2003) · Physical Review Letters · doi:10.1103/physrevlett.91.173005 · Cited by 572
Implementation of Cavity Squeezing of a Collective Atomic Spin
Leroux, I. D., Schleier-Smith, M. H., & Vuletić, V. (2010) · Physical Review Letters · doi:10.1103/physrevlett.104.073602 · Cited by 541
Making optical atomic clocks more stable with 10−16-level laser stabilization
Jiang, Y. Y., Ludlow, A. D., Lemke, N. D., Fox, R. W., Sherman, J. A., Ma, L.-S., & Oates, C. W. (2011) · Nature Photonics · doi:10.1038/nphoton.2010.313 · Cited by 462
Self-citationQuantum State Engineering and Precision Metrology Using State-Insensitive Light Traps
Ye, J., Kimble, H. J., & Katori, H. (2008) · Science · doi:10.1126/science.1148259 · Cited by 419
Tenfold reduction of Brownian noise in high-reflectivity optical coatings
Cole, G. D., Zhang, W., Martin, M. J., Ye, J., & Aspelmeyer, M. (2013) · Nature Photonics · doi:10.1038/nphoton.2013.174 · Cited by 382
Research works printed but not linked: 1
- G. J. Dick J. D. Prestage C. A. Greenhall L. Maleki in Proceedings of the 22nd Precise Time and Time Interval Meeting (NASA Conference Publication 3116 Washington DC 1990) pp. 487–508.
Cited by
Items 101–200 of 938
Searching for Topological Defect Dark Matter via Nongravitational Signatures
Stadnik, Y. V., & Flambaum, V. V. (2014) · Physical Review Letters · doi:10.1103/physrevlett.113.151301 · Cited by 79
Schachenmayer, J., Pikovski, A., & Rey, A. M. (2015) · New Journal of Physics · doi:10.1088/1367-2630/17/6/065009 · Cited by 79
Large-momentum-transfer Bragg interferometer with strontium atoms
Mazzoni, T., Zhang, X., del Aguila, R. P., Salvi, L., Poli, N., & Tino, G. M. (2015) · Physical Review A · doi:10.1103/physreva.92.053619 · Cited by 79
Quantum sensor networks as exotic field telescopes for multi-messenger astronomy
Dailey, C., Bradley, C., Kimball, D. F. J., Sulai, I., Pustelny, S., Wickenbrock, A., & Derevianko, A. (2020) · Nature Astronomy · doi:10.1038/s41550-020-01242-7 · Cited by 78
Ultranarrow Linewidth Photonic‐Atomic Laser
Zhang, W., Stern, L., Carlson, D., Bopp, D., Newman, Z., Kang, S., Kitching, J., & Papp, S. B. (2020) · Laser & Photonics Reviews · doi:10.1002/lpor.201900293 · Cited by 72
Benkler, E., Lisdat, C., & Sterr, U. (2015) · Metrologia · doi:10.1088/0026-1394/52/4/565 · Cited by 69
Vernier microcombs for integrated optical atomic clocks
Wu, K., O’Malley, N. P., Fatema, S., Wang, C., Girardi, M., Alshaykh, M. S., Ye, Z., Leaird, D. E., Qi, M., & Weiner, A. M. (2025) · Nature Photonics · doi:10.1038/s41566-025-01617-0 · Cited by 76
Probing many-body interactions in an optical lattice clock
Rey, A. M., Gorshkov, A. V., Kraus, C. V., Martin, M. J., Bishof, M., Swallows, M. D., Zhang, X., Benko, C., Ye, J., Lemke, N. D., et al. (2014) · Annals of Physics · doi:10.1016/j.aop.2013.11.002 · Cited by 63
Self-citationStability of a trapped-atom clock on a chip
Szmuk, R., Dugrain, V., Maineult, W., Reichel, J., & Rosenbusch, P. (2015) · Physical Review A · doi:10.1103/physreva.92.012106 · Cited by 75
Kulosa, A. P., Fim, D., Zipfel, K. H., Rühmann, S., Sauer, S., Jha, N., Gibble, K., Ertmer, W., Rasel, E. M., Safronova, M. S., et al. (2015) · Physical Review Letters · doi:10.1103/physrevlett.115.240801 · Cited by 64
Cavity-aided nondemolition measurements for atom counting and spin squeezing
Chen, Z., Bohnet, J. G., Weiner, J. M., Cox, K. C., & Thompson, J. K. (2014) · Physical Review A · doi:10.1103/physreva.89.043837 · Cited by 72
Magnetic-Dipole Transitions in Highly Charged Ions as a Basis of Ultraprecise Optical Clocks
Yudin, V. I., Тайченачев, А. В., & Derevianko, A. (2014) · Physical Review Letters · doi:10.1103/physrevlett.113.233003 · Cited by 75
A small weak scale from a small cosmological constant
Arvanitaki, A., Dimopoulos, S., Gorbenko, V., Huang, J., & Tilburg, K. V. (2017) · Journal of High Energy Physics · doi:10.1007/jhep05(2017)071 · Cited by 76
Grosche, G. (2014) · Optics Letters · doi:10.1364/ol.39.002545 · Cited by 72
Pizzocaro, M., Thoumany, P., Rauf, B., Bregolin, F., Milani, G., Clivati, C., Costanzo, G. A., Levi, F., & Calonico, D. (2017) · Metrologia · doi:10.1088/1681-7575/aa4e62 · Cited by 58
Self-citationMorzyński, P., Bober, M., Bartoszek-Bober, D., Nawrocki, J., Krehlik, P., Śliwczyński, Ł., Lipiński, M., Masłowski, P., Cygan, A., Dunst, P., et al. (2015) · Scientific Reports · doi:10.1038/srep17495 · Cited by 73
Cs-based optical frequency measurement using cross-linked optical and microwave oscillators
Tamm, C., Huntemann, N., Lipphardt, B., Gerginov, V., Nemitz, N., Kazda, M., Weyers, S., & Peik, E. (2014) · Physical Review A · doi:10.1103/physreva.89.023820 · Cited by 72
Photonic comb-rooted synthesis of ultra-stable terahertz frequencies
Shin, D.-C., Kim, B. S., Jang, H., Kim, Y., & Kim, S. (2023) · Nature Communications · doi:10.1038/s41467-023-36507-y · Cited by 72
Attosecond timing in optical-to-electrical conversion
Baynes, F. N., Quinlan, F., Fortier, T. M., Zhou, Q., Beling, A., Campbell, J. C., & Diddams, S. A. (2015) · Optica · doi:10.1364/optica.2.000141 · Cited by 72
Shen, H., Li, L., Bi, J., Wang, J., & Chen, L. (2015) · Physical Review A · doi:10.1103/physreva.92.063809 · Cited by 71
Ultrastable Free-Space Laser Links for a Global Network of Optical Atomic Clocks
Gozzard, D. R., Howard, L. A., Dix-Matthews, B. P., Karpathakis, S., Gravestock, C., & Schediwy, S. (2022) · Physical Review Letters · doi:10.1103/physrevlett.128.020801 · Cited by 70
Optical-Clock-Based Time Scale
Yao, J., Sherman, J. A., Fortier, T., Leopardi, H., Parker, T., McGrew, W., Zhang, X., Nicolodi, D., Fasano, R., Schäffer, S. A., et al. (2019) · Physical Review Applied · doi:10.1103/physrevapplied.12.044069 · Cited by 69
Self-citationKondo effect in alkaline-earth-metal atomic gases with confinement-induced resonances
Zhang, R., Zhang, D., Cheng, Y., Chen, W., Zhang, P., & Zhai, H. (2016) · Physical Review A · doi:10.1103/physreva.93.043601 · Cited by 69
Laser-Frequency Stabilization Based on Steady-State Spectral-Hole Burning inEu3+∶Y2SiO5
Cook, S., Rosenband, T., & Leibrandt, D. R. (2015) · Physical Review Letters · doi:10.1103/physrevlett.114.253902 · Cited by 60
Conditional Ramsey Spectroscopy with Synchronized Atoms
Xu, M., & Holland, M. (2015) · Physical Review Letters · doi:10.1103/physrevlett.114.103601 · Cited by 68
Exploring the anisotropic Kondo model in and out of equilibrium with alkaline-earth atoms
Kanász-Nagy, M., Ashida, Y., Shi, T., Moca, C. P., Ikeda, T. N., Fölling, S., Cirac, J. I., Zaránd, G., & Demler, E. (2018) · Physical review. B./Physical review. B · doi:10.1103/physrevb.97.155156 · Cited by 68
Dicke Superradiance in Ordered Arrays of Multilevel Atoms
Masson, S. J., Covey, J. P., Will, S., & Asenjo-García, A. (2024) · PRX Quantum · doi:10.1103/prxquantum.5.010344 · Cited by 67
Phase Locking a Clock Oscillator to a Coherent Atomic Ensemble
Kohlhaas, R., Bertoldi, A., Cantin, E., Aspect, A., Landragin, A., & Bouyer, P. (2015) · Physical Review X · doi:10.1103/physrevx.5.021011 · Cited by 47
Laser cooling in a chip-scale platform
McGilligan, J. P., Moore, K. R., Dellis, A., Martinez, G. D., de Clercq, E., Griffin, P. F., Arnold, A. S., Riis, E., Boudot, R., & Kitching, J. (2020) · Applied Physics Letters · doi:10.1063/5.0014658 · Cited by 67
Zanon-Willette, T., Lefèvre, R., Metzdorff, R., Sillitoe, N., Almonacil, S., Minissale, M., de Clercq, E., Тайченачев, А. В., Yudin, V. I., & Arimondo, E. (2018) · Reports on Progress in Physics · doi:10.1088/1361-6633/aac9e9 · Cited by 67
Determination of a high spatial resolution geopotential model using atomic clock comparisons
Lion, G., Panet, I., Wolf, P., Guerlin, C., Bize, S., & Delva, P. (2017) · Journal of Geodesy · doi:10.1007/s00190-016-0986-6 · Cited by 66
“To date, the best of these instruments reach a stability of 1.6×10−18 (NIST, RIKEN + Univ. Tokyo, Hinkley et al. 2013) after 7 hours of integration time.”
BackgroundInfluentialProspects for atomic clocks based on large ion crystals
Arnold, K., Hajiyev, E., Paez, E., Lee, C. H., Barrett, M. D., & Bollinger, J. (2015) · Physical Review A · doi:10.1103/physreva.92.032108 · Cited by 62
Optically referenced broadband electronic synthesizer with 15 digits of resolution
Fortier, T. M., Rolland, A., Quinlan, F., Baynes, F. N., Metcalf, A. J., Hati, A., Ludlow, A. D., Hinkley, N., Shimizu, M., Ishibashi, T., et al. (2016) · Laser & Photonics Review · doi:10.1002/lpor.201500307 · Cited by 66
Self-citationTerahertz Frequency Metrology for Spectroscopic Applications: a Review
Consolino, L., Bartalini, S., & Natale, P. D. (2017) · Journal of Infrared Millimeter and Terahertz Waves · doi:10.1007/s10762-017-0406-x · Cited by 66
Collective Spin-Light and Light-Mediated Spin-Spin Interactions in an Optical Cavity
Li, Z., Braverman, B., Colombo, S., Shu, C., Kawasaki, A., Adiyatullin, A. F., Pedrozo-Peñafiel, E., Mendez, E., & Vuletić, V. (2022) · PRX Quantum · doi:10.1103/prxquantum.3.020308 · Cited by 66
Safronova, M. S., Dzuba, V. A., Flambaum, V. V., Safronova, M. S., Porsev, S. G., & Kozlov, M. G. (2014) · Physical Review A · doi:10.1103/physreva.90.042513 · Cited by 65
Quantum Network of Atom Clocks: A Possible Implementation with Neutral Atoms
Kómár, P., Topcu, T., Kessler, E. M., Derevianko, A., Vuletić, V., Ye, J., & Lukin, M. D. (2016) · Physical Review Letters · doi:10.1103/physrevlett.117.060506 · Cited by 42
Single-Beam Zeeman Slower and Magneto-Optical Trap Using a Nanofabricated Grating
Barker, D. S., Norrgard, E. B., Klimov, N. N., Fedchak, J. A., Scherschligt, J. K., & Eckel, S. (2019) · Physical Review Applied · doi:10.1103/physrevapplied.11.064023 · Cited by 63
Active Faraday optical frequency standard
Zhuang, W., & Chen, J. (2014) · Optics Letters · doi:10.1364/ol.39.006339 · Cited by 62
Enhancing parameter precision of optimal quantum estimation by direct quantum feedback
Zheng, Q., Ge, L., Yao, Y., & Zhi, Q. (2015) · Physical Review A · doi:10.1103/physreva.91.033805 · Cited by 62
Frequency and time transfer for metrology and beyond using telecommunication network fibres
Lopez, O., Kéfélian, F., Jiang, H., Haboucha, A., Bercy, A., Stefani, F., Chanteau, B., Kanj, A., Rovera, D., Achkar, J., et al. (2015) · Comptes Rendus. Physique · doi:10.1016/j.crhy.2015.04.005 · Cited by 61
Atomic fountains and optical clocks at SYRTE: Status and perspectives
Abgrall, M., Chupin, B., De Sarlo, L., Guéna, J., Laurent, P., Le Coq, Y., Le Targat, R., Lodewyck, J., Lours, M., Rosenbusch, P., et al. (2015) · Comptes Rendus. Physique · doi:10.1016/j.crhy.2015.03.010 · Cited by 53
Chen, X., Lu, J., Cui, Y., Zhang, J., Lu, X., Tian, X., Ci, C., Liu, B., Wu, H., Tang, T., et al. (2015) · Scientific Reports · doi:10.1038/srep18343 · Cited by 60
Zhang, C., Yuan, H., Tang, Z., Quan, W., & Fang, J. (2016) · Applied Physics Reviews · doi:10.1063/1.4972187 · Cited by 60
Frequency comb up- and down-conversion in synchronously driven χ(2) optical microresonators
Herr, S. J., Brasch, V., Szabados, J., Obrzud, E., Jia, Y., Lecomte, S., Buse, K., Breunig, I., & Herr, T. (2018) · Optics Letters · doi:10.1364/ol.43.005745 · Cited by 59
Modified hyper-Ramsey methods for the elimination of probe shifts in optical clocks
Hobson, R., Bowden, W., King, S. A., Baird, P. E. G., Hill, I. R., & Gill, P. (2016) · Physical Review A · doi:10.1103/physreva.93.010501 · Cited by 60
Chutani, R., Maurice, V. N., Passilly, N., Gorecki, C., Boudot, R., Hafiz, M. A., Abbé, P., Galliou, S., Rauch, J., & de Clercq, E. (2015) · Scientific Reports · doi:10.1038/srep14001 · Cited by 58
Hobson, R., Bowden, W., Vianello, A., Silva, A., Baynham, C. F. A., Margolis, H. S., Baird, P. E. G., Gill, P., & Hill, I. R. (2020) · Metrologia · doi:10.1088/1681-7575/abb530 · Cited by 58
Oscillator metrology with software defined radio
Sherman, J. A., & Jördens, R. (2016) · Review of Scientific Instruments · doi:10.1063/1.4950898 · Cited by 57
Self-citationOptical frequency divider with division uncertainty at the 10−21 level
Yao, Y., Jiang, Y., Yu, H., Bi, Z., & Ma, L. (2016) · National Science Review · doi:10.1093/nsr/nww063 · Cited by 57
Understanding Phase Error and Jitter: Definitions, Implications, Simulations, and Measurement
Galton, I., & Weltin-Wu, C. (2018) · IEEE Transactions on Circuits and Systems I Regular Papers · doi:10.1109/tcsi.2018.2856247 · Cited by 57
Optically synchronized fibre links using spectrally pure chip-scale lasers
Brodnik, G. M., Harrington, M. W., Dallyn, J. H., Bose, D., Zhang, W., Stern, L., Morton, P. A., Behunin, R. O., Papp, S. B., & Blumenthal, D. J. (2021) · Nature Photonics · doi:10.1038/s41566-021-00831-w · Cited by 58
Ground-based optical atomic clocks as a tool to monitor vertical surface motion
Bondarescu, R., Schärer, A., Lundgren, A., Hetényi, G., Houlié, N., Jetzer, P., & Bondarescu, M. (2015) · Geophysical Journal International · doi:10.1093/gji/ggv246 · Cited by 56
Reservoir spectroscopy of 5s5p 3P2 – 5snd 3D1,2,3 transitions in strontium
Stellmer, S., & Schreck, F. (2014) · Physical Review A · doi:10.1103/physreva.90.022512 · Cited by 56
Leefer, N., Gerhardus, A., Budker, D., Flambaum, V. V., & Stadnik, Y. V. (2016) · Physical Review Letters · doi:10.1103/physrevlett.117.271601 · Cited by 56
Long-term stable optical cavity for special relativity tests in space
Sanjuán, J., Abich, K., Gohlke, M., Resch, A., Schuldt, T., Wegehaupt, T., Barwood, G. P., Gill, P., & Braxmaier, C. (2019) · Optics Express · doi:10.1364/oe.27.036206 · Cited by 56
Evaluation of long term performance of continuously running atomic fountains
Peil, S., Hanssen, J. L., Swanson, T. B., Taylor, J. A., & Ekstrom, C. R. (2014) · Metrologia · doi:10.1088/0026-1394/51/3/263 · Cited by 55
Direct comparison of optical lattice clocks with an intercontinental baseline of 9000 km
Hachisu, H., Fujieda, M., Nagano, S., Gotoh, T., Nogami, A., Ido, T., Falke, S., Huntemann, N., Grebing, C., Lipphardt, B., et al. (2014) · Optics Letters · doi:10.1364/ol.39.004072 · Cited by 53
Sr88+single-ion optical clock with a stability approaching the quantum projection noise limit
Dubé, P., Madej, A. A., Shiner, A., & Jian, B. (2015) · Physical Review A · doi:10.1103/physreva.92.042119 · Cited by 50
Frequency ratio measurement of ^171Yb and ^87Sr optical lattice clocks
Akamatsu, D., Yasuda, M., Inaba, H., Hosaka, K., Tanabe, T., Onae, A., & Hong, F.-L. (2014) · Optics Express · doi:10.1364/oe.22.007898 · Cited by 48
Measurement of Magic Wavelengths for the Ca+40 Clock Transition
Liu, P., Huang, Y., Wu, B., Shao, H., Guan, H., Tang, Y.-B., Li, C., Mitroy, J., & Gao, K. (2015) · Physical Review Letters · doi:10.1103/physrevlett.114.223001 · Cited by 52
Highly sensitive microwave electrometry with enhanced instantaneous bandwidth
Yang, B., Yan, Y., Li, X., Xiao, L., Li, X., Chen, L. Q., Deng, J., & Cheng, H.-D. (2024) · Physical Review Applied · doi:10.1103/physrevapplied.21.l031003 · Cited by 51
Broadband Noise Limit in the Photodetection of Ultralow Jitter Optical Pulses
Sun, W., Quinlan, F., Fortier, T. M., Deschênes, J.-D., Fu, Y., Diddams, S. A., & Campbell, J. C. (2014) · Physical Review Letters · doi:10.1103/physrevlett.113.203901 · Cited by 51
Precision measurement and frequency metrology with ultracold atoms
Zhang, X., & Ye, J. (2016) · National Science Review · doi:10.1093/nsr/nww013 · Cited by 51
Inner-shell magnetic dipole transition in Tm atoms: A candidate for optical lattice clocks
Сукачев, Д. Д., Fedorov, S., TOLSTIKHINA, I. Y., Tregubov, D. O., Калганова, Е. С., Vishnyakova, G. A., Golovizin, A. A., Kolachevsky, N., Khabarova, K. Y., & Сорокин, В. Н. (2016) · Physical Review A · doi:10.1103/physreva.94.022512 · Cited by 51
Winchester, M. N., Norcia, M. A., Cline, J., & Thompson, J. K. (2017) · Physical Review Letters · doi:10.1103/physrevlett.118.263601 · Cited by 51
Fibre-optic delivery of time and frequency to VLBI station
Krehlik, P., Buczek, Ł., Kołodziej, J., Lipiński, M., Śliwczyński, Ł., Nawrocki, J., Nogaś, P., Marecki, A., Pazderski, E., Ablewski, P., et al. (2017) · Astronomy and Astrophysics · doi:10.1051/0004-6361/201730615 · Cited by 51
Hu, J., Chen, W., Vendeiro, Z., Urvoy, A., Braverman, B., & Vuletić, V. (2017) · Physical Review A · doi:10.1103/physreva.96.050301 · Cited by 51
The unit of time: Present and future directions
Bize, S. (2019) · Comptes Rendus. Physique · doi:10.1016/j.crhy.2019.02.002 · Cited by 47
Voigt, C., Denker, H., & Timmen, L. (2016) · Metrologia · doi:10.1088/0026-1394/53/6/1365 · Cited by 50
Low noise, self-referenced all polarization maintaining Ytterbium fiber laser frequency comb
Li, Y., Kuse, N., Rolland, A., Stepanenko, Y., Radzewicz, C., & Fermann, M. E. (2017) · Optics Express · doi:10.1364/oe.25.018017 · Cited by 50
Prasai, K., Jiang, J., Mishkin, A. S., Shyam, B., Angelova, S. V., Birney, R., Drabold, D. A., Fazio, M., Gustafson, E. K., Harry, G. M., et al. (2019) · Physical Review Letters · doi:10.1103/physrevlett.123.045501 · Cited by 50
Quantum Enhanced Optical Phase Estimation With a Squeezed Thermal State
Yu, J., Qin, Y., Qin, J., Wang, H., Yan, Z., Jia, X., & Peng, K. (2020) · Physical Review Applied · doi:10.1103/physrevapplied.13.024037 · Cited by 50
Optical frequency transfer via a 660 km underground fiber link using a remote Brillouin amplifier
Raupach, S. M. F., Koczwara, A., & Grosche, G. (2014) · Optics Express · doi:10.1364/oe.22.026537 · Cited by 45
A microrod-resonator Brillouin laser with 240 Hz absolute linewidth
Loh, W., Becker, J., Cole, D. C., Coillet, A., Baynes, F. N., Papp, S. B., & Diddams, S. A. (2016) · New Journal of Physics · doi:10.1088/1367-2630/18/4/045001 · Cited by 49
Probing beyond the laser coherence time in optical clock comparisons
Hume, D. B., & Leibrandt, D. R. (2016) · Physical Review A · doi:10.1103/physreva.93.032138 · Cited by 44
Confinement of an alkaline-earth element in a grating magneto-optical trap
Sitaram, A., Elgee, P. K., Campbell, G. K., Klimov, N. N., Eckel, S., & Barker, D. S. (2020) · Review of Scientific Instruments · doi:10.1063/5.0019551 · Cited by 48
Core-shell magneto-optical trap for alkaline-earth-metal-like atoms
Lee, J., Lee, J. H., Noh, J., & Mun, J. (2015) · Physical Review A · doi:10.1103/physreva.91.053405 · Cited by 47
Schkolnik, V., Budker, D., Fartmann, O., Flambaum, V. V., Hollberg, L. W., Kalaydzhyan, T., Kolkowitz, S., Krutzik, M., Ludlow, A. D., Newbury, N. R., et al. (2022) · Quantum Science and Technology · doi:10.1088/2058-9565/ac9f2b · Cited by 47
Self-citationMeasuring absolute frequencies beyond the GPS limit via long-haul optical frequency dissemination
Clivati, C., Cappellini, G., Livi, L. F., Poggiali, F., de Cumis, M. S., Mancini, M., Pagano, G., Frittelli, M., Mura, A., Costanzo, G. A., et al. (2016) · Optics Express · doi:10.1364/oe.24.011865 · Cited by 48
Optical clock sensitive to variations of the fine-structure constant based on the Ho14+ ion
Dzuba, V. A., Flambaum, V. V., & Katori, H. (2015) · Physical Review A · doi:10.1103/physreva.91.022119 · Cited by 47
Safronova, M. S., Dzuba, V. A., Flambaum, V. V., Safronova, M. S., Porsev, S. G., & Kozlov, M. G. (2014) · Physical Review A · doi:10.1103/physreva.90.052509 · Cited by 46
Strontium optical lattice clock at the National Time Service Center
Wang, Y., Yin, M.-J., Ren, J., Xu, Q., Lu, B., Han, J.-X., Guo, Y., & Chang, H. (2018) · Chinese Physics B · doi:10.1088/1674-1056/27/2/023701 · Cited by 46
Systematic evaluation of a 171Yb optical clock by synchronous comparison between two lattice systems
Gao, Q., Zhou, M., Han, C., Li, S., Zhang, S., Yao, Y., Li, B., Qiao, H., Ai, D., Lou, G., et al. (2018) · Scientific Reports · doi:10.1038/s41598-018-26365-w · Cited by 45
Spin squeezing and many-body dipolar dynamics in optical lattice clocks
Qu, C., & Rey, A. M. (2019) · Physical Review A · doi:10.1103/physreva.100.041602 · Cited by 45
Dichroic Two-Photon Rubidium Frequency Standard
Perrella, C., Light, P. S., Anstie, J. D., Baynes, F. N., White, R. T., & Luiten, A. N. (2019) · Physical Review Applied · doi:10.1103/physrevapplied.12.054063 · Cited by 45
Entanglement-enhanced optical atomic clocks
Colombo, S., Pedrozo-Peñafiel, E., & Vuletić, V. (2022) · Applied Physics Letters · doi:10.1063/5.0121372 · Cited by 45
Shang, H., Zhang, X., Zhang, S., Pan, D., Chen, H., & Chen, J. (2017) · Optics Express · doi:10.1364/oe.25.030459 · Cited by 45
Compact Rb optical frequency standard with 10−15 stability
Zhang, S., Zhang, X., Cui, J., Jiang, Z., Shang, H., Zhu, C., Chang, P., Zhang, L., Tu, J., & Chen, J. (2017) · Review of Scientific Instruments · doi:10.1063/1.5006962 · Cited by 44
Resonance tracking in a micromechanical device using phononic frequency combs
Ganesan, A., & Seshia, A. A. (2019) · Scientific Reports · doi:10.1038/s41598-019-46003-3 · Cited by 43
Optical atomic clock interrogation using an integrated spiral cavity laser
Loh, W., Reens, D., Kharas, D., Sumant, A., Belanger, C., Maxson, R., Medeiros, A., Setzer, W., Gray, D. J., DeBry, K., et al. (2025) · Nature Photonics · doi:10.1038/s41566-024-01588-8 · Cited by 43
Higher-order Hermite-Gauss modes for gravitational waves detection
Ast, S., Pace, S. D., Millo, J., Pichot, M., Turconi, M., Christensen, N. L., & Chaibi, W. (2021) · Physical review. D/Physical review. D. · doi:10.1103/physrevd.103.042008 · Cited by 43
Generalized hyper-Ramsey resonance with separated oscillating fields
Zanon-Willette, T., Yudin, V. I., & Тайченачев, А. В. (2015) · Physical Review A · doi:10.1103/physreva.92.023416 · Cited by 43
Thermometry via Light Shifts in Optical Lattices
McDonald, M., McGuyer, B. H., Iwata, G. Z., & Zelevinsky, T. (2015) · Physical Review Letters · doi:10.1103/physrevlett.114.023001 · Cited by 42
Ahn, C., Na, Y., Hyun, M., Bae, J., & Kim, J. (2021) · Photonics Research · doi:10.1364/prj.443316 · Cited by 41
Ultra-broadband dual-branch optical frequency comb with 10−18instability
Rolland, A., Li, P., Kuse, N., Jiang, J., Cassinerio, M., Langrock, C., & Fermann, M. E. (2018) · Optica · doi:10.1364/optica.5.001070 · Cited by 35
Strong coupling on a forbidden transition in strontium and nondestructive atom counting
Norcia, M. A., & Thompson, J. K. (2016) · Physical Review A · doi:10.1103/physreva.93.023804 · Cited by 42
Relativistic corrections for time and frequency transfer in optical fibres
Geršl, J., Delva, P., & Wolf, P. (2015) · Metrologia · doi:10.1088/0026-1394/52/4/552 · Cited by 40
“Atomic clocks have been improving rapidly over the past years and are now reaching stabilities and accuracies of a few parts in 10(18) in fractional frequency [1, 2].”
BackgroundMargolis, H. S., & Gill, P. (2015) · Metrologia · doi:10.1088/0026-1394/52/5/628 · Cited by 40
Ultranarrow Superradiant Lasing by Dark Atom-Photon Dressed States
Zhang, Y., Shan, C., & Mølmer, K. (2021) · Physical Review Letters · doi:10.1103/physrevlett.126.123602 · Cited by 40
Metadata
- Authors
- Hinkley, N., Sherman, J. A., Phillips, N. B., Schioppo, M., Lemke, N. D., Beloy, K., Pizzocaro, M., Oates, C. W., & Ludlow, A. D.
- Affiliations
- National Institute of Standards and Technology (US)
- Corresponding author
- Ludlow, A. D.
- Venue
- Science
- Published
- 2013-09-13
- Volume
- 341
- Issue
- 6151
- Pages
- 1215-1218
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W2015575484
- Cited by
- 817
- References
- 28
- Citations by year
- 2026: 22 · 2025: 38 · 2024: 46 · 2023: 34 · 2022: 39 · 2021: 45 · 2020: 45 · 2019: 57 · 2018: 58 · 2017: 63 · 2016: 99 · 2015: 145 · 2014: 111 · 2013: 14
- FWCI
- 63.43
- Type
- journal article
- Language
- en
- Open access
- green
- arxiv.org
- Locations
- Science (publishedVersion)
- PubMed (publishedVersion)
- arXiv (Cornell University) (submittedVersion)
- CINECA IRIS Institutional Research Information System (IRIS Istituto Nazionale di Ricerca Metrologica) (submittedVersion)
- arXiv (Cornell University) (public-domain)
- Science
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Frequency and Time Standards
- Physical Sciences › Computer Science › Computer Networks and Communications › Network Time Synchronization Technologies
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Cold Atom Physics and Bose-Einstein Condensates
- Keywords
- optical lattice clock, ytterbium, relativistic geodesy, navigation, beyond the Standard Model
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.