An Atomic Clock with 10 –18 Instability
Open accessThe DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
Tick, Tick, Tick…: Many aspects of everyday life from communication to navigation rely on the precise ticking of the microwave transitions of the atoms in atomic clocks. Optical transitions occur at much higher frequency and so offer the opportunity to reduce the scale of the ticks even more. Hinkley et al. (p. 1215 , published online 22 August; see the Perspective by Margolis ) compare the ticking of two optical clocks and report an instability near the 10 −18 level. Such performance will improve tests of general relativity and pave the way for a redefinition of the second.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The frequency stability and uncertainty of the latest generation of optical atomic clocks is now approaching the one part in 10 18 level.”
From Geodetic methods to determine the relativistic redshift at the level of 10 $$^{-18}$$ - 18 in the context of international timescales: a review and practical results (2018) · cites this paper as Hinkley et al. 2013
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The optical clocks operate at frequencies about five orders of magnitude higher than the caesium clocks and thus achieve a higher frequency stability, approaching fractional stabilities and uncertainties of one part in 10 18 (Chou et al. 2010;Hinkley et al. 2013;Bloom et al. 2014;Nicholson et al. 2015;Ushijima et al. 2015;Huntemann et al. 2016).”
From Geodetic methods to determine the relativistic redshift at the level of 10 $$^{-18}$$ - 18 in the context of international timescales: a review and practical results (2018) · cites this paper as Hinkley et al. 2013
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“To date, the best of these instruments reach a stability of 1 . 6 × 10 -18 (NIST, RIKEN + Univ. Tokyo, Hinkley et al. 2013) after 7 hours of integration time.”
From Determination of a high spatial resolution geopotential model using atomic clock comparisons (2017) · cites this paper as Hinkley et al. 2013
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“Optical clocks are—due to their orders of magnitude better precision1 and accuracy234 than their microwave counterparts realizing the definition of the SI-second—new sensors with highest resolving power”
From A clock network for geodesy and fundamental science (2016) · cites this paper as [1]
The cited source says what the claim attributes to it.
In the citing paper
“This demonstrates that use of a state-of-the-art OLO affords unprecedented optical clock stability 10-15 .”
From Ultrastable optical clock with two cold-atom ensembles (2017) · cites this paper as [11]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Frequency Ratio of Al+and Hg+Single-Ion Optical Clocks; Metrology at the 17th Decimal Place
Rosenband, T., Hume, D. B., Schmidt, P. O., Chou, C. W., Brusch, A., Lorini, L., Oskay, W. H., Drullinger, R. E., Fortier, T. M., Stalnaker, J. E., et al. (2008) · Science · doi:10.1126/science.1154622 · Cited by 1,450
Frequency Comparison of Two High-Accuracy Al + Optical Clocks
Chou, C., Hume, D., Koelemeij, J., Wineland, D., & Rosenband, T. (2010) · Physical Review Letters · doi:10.1103/physrevlett.104.070802 · Cited by 903
Chou, C. W., Hume, D. B., Rosenband, T., & Wineland, D. J. (2010) · Science · doi:10.1126/science.1192720 · Cited by 828
A sub-40-mHz-linewidth laser based on a silicon single-crystal optical cavity
Kessler, T., Hagemann, C., Grebing, C., Legero, T., Sterr, U., Riehle, F., Martin, M. J., Chen, L., & Ye, J. (2012) · Nature Photonics · doi:10.1038/nphoton.2012.217 · Cited by 754
Quantum projection noise: Population fluctuations in two-level systems
Itano, W. M., Bergquist, J. C., Bollinger, J. J., Gilligan, J. M., Heinzen, D. J., Moore, F. L., Raizen, M. G., & Wineland, D. J. (1993) · Physical Review A · doi:10.1103/physreva.47.3554 · Cited by 613
Ultrastable Optical Clock with Neutral Atoms in an Engineered Light Shift Trap
Katori, H., Takamoto, M., Pal’chikov, V. G., & Ovsiannikov, V. D. (2003) · Physical Review Letters · doi:10.1103/physrevlett.91.173005 · Cited by 572
Implementation of Cavity Squeezing of a Collective Atomic Spin
Leroux, I. D., Schleier-Smith, M. H., & Vuletić, V. (2010) · Physical Review Letters · doi:10.1103/physrevlett.104.073602 · Cited by 541
Making optical atomic clocks more stable with 10−16-level laser stabilization
Jiang, Y. Y., Ludlow, A. D., Lemke, N. D., Fox, R. W., Sherman, J. A., Ma, L.-S., & Oates, C. W. (2011) · Nature Photonics · doi:10.1038/nphoton.2010.313 · Cited by 462
Self-citationQuantum State Engineering and Precision Metrology Using State-Insensitive Light Traps
Ye, J., Kimble, H. J., & Katori, H. (2008) · Science · doi:10.1126/science.1148259 · Cited by 419
Tenfold reduction of Brownian noise in high-reflectivity optical coatings
Cole, G. D., Zhang, W., Martin, M. J., Ye, J., & Aspelmeyer, M. (2013) · Nature Photonics · doi:10.1038/nphoton.2013.174 · Cited by 382
Research works printed but not linked: 1
- G. J. Dick J. D. Prestage C. A. Greenhall L. Maleki in Proceedings of the 22nd Precise Time and Time Interval Meeting (NASA Conference Publication 3116 Washington DC 1990) pp. 487–508.
Cited by
Degen, C. L., Reinhard, F., & Cappellaro, P. (2017) · Reviews of Modern Physics · doi:10.1103/revmodphys.89.035002 · Cited by 4,045
Ludlow, A. D., Boyd, M. M., Ye, J., Peik, E., & Schmidt, P. O. (2015) · Reviews of Modern Physics · doi:10.1103/revmodphys.87.637 · Cited by 2,385
Self-citationQuantum metrology with nonclassical states of atomic ensembles
Pezzè, L., Smerzi, A., Oberthaler, M. K., Schmied, R., & Treutlein, P. (2018) · Reviews of Modern Physics · doi:10.1103/revmodphys.90.035005 · Cited by 1,682
An optical lattice clock with accuracy and stability at the 10−18 level
Bloom, B. J., Nicholson, T. L., Williams, J. R., Campbell, S. L., Bishof, M., Zhang, X., Zhang, W., Bromley, S. L., & Ye, J. (2014) · Nature · doi:10.1038/nature12941 · Cited by 1,073
Molecular spins for quantum computation
Gaita-Ariño, A., Luis, F., Hill, S., & Coronado, E. (2019) · Nature Chemistry · doi:10.1038/s41557-019-0232-y · Cited by 889
Systematic evaluation of an atomic clock at 2 × 10−18 total uncertainty
Nicholson, T. L., Campbell, S. L., Hutson, R. B., Marti, G. E., Bloom, B. J., McNally, R. L., Zhang, W., Barrett, M. D., Safronova, M. S., Strouse, G. F., et al. (2015) · Nature Communications · doi:10.1038/ncomms7896 · Cited by 780
Kómár, P., Kessler, E. M., Bishof, M., Jiang, L., Sørensen, A. S., Ye, J., & Lukin, M. D. (2014) · Nature Physics · doi:10.1038/nphys3000 · Cited by 768
Cryogenic optical lattice clocks
Ushijima, I., Takamoto, M., Das, M., Ohkubo, T., & Katori, H. (2015) · Nature Photonics · doi:10.1038/nphoton.2015.5 · Cited by 627
Ultralow-noise mode-locked fiber lasers and frequency combs: principles, status, and applications
Kim, J., & Song, Y. (2016) · Advances in Optics and Photonics · doi:10.1364/aop.8.000465 · Cited by 567
Microresonator frequency comb optical clock
Papp, S. B., Beha, K., Del’Haye, P., Quinlan, F., Lee, H., Vahala, K. J., & Diddams, S. A. (2014) · Optica · doi:10.1364/optica.1.000010 · Cited by 545
Hunting for topological dark matter with atomic clocks
Derevianko, A., & Pospelov, M. (2014) · Nature Physics · doi:10.1038/nphys3137 · Cited by 522
Godun, R. M., Nisbet-Jones, P. B. R., Jones, J. M., King, S. A., Johnson, L. A. M., Margolis, H. S., Szymaniec, K., Lea, S. N., Bongs, K., & Gill, P. (2014) · Physical Review Letters · doi:10.1103/physrevlett.113.210801 · Cited by 468
A clock network for geodesy and fundamental science
Lisdat, C., Grosche, G., Quintin, N., Shi, C., Raupach, S. M. F., Grebing, C., Nicolodi, D., Stefani, F., Al-Masoudi, A., Dörscher, S., et al. (2016) · Nature Communications · doi:10.1038/ncomms12443 · Cited by 460
“Optical clocks are – due to their orders of magnitude better precision (1) and accuracy (2,3,4) than their microwave counterparts realizing the definition of the SI second – new sensors with highest resolving power to, e.”
BackgroundSearching for dilaton dark matter with atomic clocks
Arvanitaki, A., Huang, J., & Van Tilburg, K. (2015) · Physical Review D · doi:10.1103/physrevd.91.015015 · Cited by 404
Gravitational wave detection with optical lattice atomic clocks
Kolkowitz, S., Pikovski, I., Langellier, N., Lukin, M. D., Walsworth, R. L., & Ye, J. (2016) · Physical Review D · doi:10.1103/physrevd.94.124043 · Cited by 396
Ultrastable optical clock with two cold-atom ensembles
Schioppo, M., Brown, R. C., McGrew, W. F., Hinkley, N., Fasano, R. J., Beloy, K., Yoon, T. H., Milani, G., Nicolodi, D., Sherman, J. A., et al. (2017) · Nature Photonics · doi:10.1038/nphoton.2016.231 · Cited by 385
Self-citationA Fermi-degenerate three-dimensional optical lattice clock
Campbell, S. L., Hutson, R. B., Marti, G. E., Goban, A., Darkwah Oppong, N., McNally, R. L., Sonderhouse, L., Robinson, J. M., Zhang, W., Bloom, B. J., et al. (2017) · Science · doi:10.1126/science.aam5538 · Cited by 384
Observation of two-orbital spin-exchange interactions with ultracold SU(N)-symmetric fermions
Scazza, F., Hofrichter, C., Höfer, M., De Groot, P. C., Bloch, I., & Fölling, S. (2014) · Nature Physics · doi:10.1038/nphys3061 · Cited by 363
Ultracold Fermi gases with emergent SU(N) symmetry
Cazalilla, M. A., & Rey, A. M. (2014) · Reports on Progress in Physics · doi:10.1088/0034-4885/77/12/124401 · Cited by 322
Spin–orbit-coupled fermions in an optical lattice clock
Kolkowitz, S., Bromley, S. L., Bothwell, T., Wall, M. L., Marti, G. E., Koller, A. P., Zhang, X., Rey, A. M., & Ye, J. (2017) · Nature · doi:10.1038/nature20811 · Cited by 288
8 × 10^−17 fractional laser frequency instability with a long room-temperature cavity
Häfner, S., Falke, S., Grebing, C., Vogt, S., Legero, T., Merimaa, M., Lisdat, C., & Sterr, U. (2015) · Optics Letters · doi:10.1364/ol.40.002112 · Cited by 286
Riehle, F. (2017) · Nature Photonics · doi:10.1038/nphoton.2016.235 · Cited by 264
Mehlstäubler, T. E., Grosche, G., Lisdat, C., Schmidt, P. O., & Denker, H. (2018) · Reports on Progress in Physics · doi:10.1088/1361-6633/aab409 · Cited by 263
“…as discussed in section 4, the duty cycle of the interrogation in the clock cycles has improved and the influence of the Dick effect has been reduced such that clock instabilities of few 10 − 16 / √ τ /s have been demonstrated (Hinkley et al 2013, Al-Masoudi et al 2015, Nicholson et al 2015).”
Search for Ultralight Scalar Dark Matter with Atomic Spectroscopy
Van Tilburg, K., Leefer, N., Bougas, L., & Budker, D. (2015) · Physical Review Letters · doi:10.1103/physrevlett.115.011802 · Cited by 253
Review: Quantum metrology and sensing with many-body systems
Montenegro, V., Mukhopadhyay, C., Yousefjani, R., Sarkar, S., Mishra, U., Paris, M. G. A., & Bayat, A. (2025) · Physics Reports · doi:10.1016/j.physrep.2025.05.005 · Cited by 244
Optical Injection Locking: From Principle to Applications
Liu, Z., & Slavik, R. (2020) · Journal of Lightwave Technology · doi:10.1109/jlt.2019.2945718 · Cited by 243
Transportable Optical Lattice Clock with 7 × 10 − 17 Uncertainty
Koller, S. B., Grotti, J., Vogt, S., Al-Masoudi, A., Dörscher, S., Häfner, S., Sterr, U., & Lisdat, C. (2017) · Physical Review Letters · doi:10.1103/physrevlett.118.073601 · Cited by 238
Invited Article: A compact optically coherent fiber frequency comb
Sinclair, L. C., Deschênes, J.-D., Sonderhouse, L., Swann, W. C., Khader, I. H., Baumann, E., Newbury, N. R., & Coddington, I. (2015) · Review of Scientific Instruments · doi:10.1063/1.4928163 · Cited by 237
Searching for Dark Matter and Variation of Fundamental Constants with Laser and Maser Interferometry
Stadnik, Y. V., & Flambaum, V. V. (2015) · Physical Review Letters · doi:10.1103/physrevlett.114.161301 · Cited by 234
Superradiance on the millihertz linewidth strontium clock transition
Norcia, M. A., Winchester, M. N., Cline, J. R. K., & Thompson, J. K. (2016) · Science Advances · doi:10.1126/sciadv.1601231 · Cited by 226
Frequency ratio of Yb and Sr clocks with 5 × 10−17 uncertainty at 150 seconds averaging time
Nemitz, N., Ohkubo, T., Takamoto, M., Ushijima, I., Das, M., Ohmae, N., & Katori, H. (2016) · Nature Photonics · doi:10.1038/nphoton.2016.20 · Cited by 221
Singh, A., Dev, K., Siljak, H., Joshi, H. D., & Magarini, M. (2021) · IEEE Communications Surveys & Tutorials · doi:10.1109/comst.2021.3109944 · Cited by 151
Matter-wave Atomic Gradiometer Interferometric Sensor (MAGIS-100)
Abe, M., Adamson, P., Borcean, M., Bortoletto, D., Bridges, K., Carman, S. P., Chattopadhyay, S., Coleman, J., Curfman, N. M., DeRose, K., et al. (2021) · Quantum Science and Technology · doi:10.1088/2058-9565/abf719 · Cited by 211
Autonomous Quantum Clocks: Does Thermodynamics Limit Our Ability to Measure Time?
Erker, P., Mitchison, M. T., Silva, R., Woods, M. P., Brunner, N., & Huber, M. (2017) · Physical Review X · doi:10.1103/physrevx.7.031022 · Cited by 210
Ultra-low loss waveguide platform and its integration with silicon photonics
Heck, M. J. R., Bauters, J. F., Davenport, M. L., Spencer, D. T., & Bowers, J. E. (2014) · Laser & Photonics Reviews · doi:10.1002/lpor.201300183 · Cited by 183
A strontium lattice clock with 3 × 10−17inaccuracy and its frequency
Falke, S., Lemke, N., Grebing, C., Lipphardt, B., Weyers, S., Gerginov, V., Huntemann, N., Hagemann, C., Al-Masoudi, A., Häfner, S., et al. (2014) · New Journal of Physics · doi:10.1088/1367-2630/16/7/073023 · Cited by 182
Self-citationOne decade of quantum optimal control in the chopped random basis
Müller, M. M., Said, R. S., Jelezko, F., Calarco, T., & Montangero, S. (2022) · Reports on Progress in Physics · doi:10.1088/1361-6633/ac723c · Cited by 179
Towards a redefinition of the second based on optical atomic clocks
Riehle, F. (2015) · Comptes Rendus. Physique · doi:10.1016/j.crhy.2015.03.012 · Cited by 174
“accuracy will give a means to evaluate and validate the estimated uncertainties. Another example would be the ratio between the frequencies of the Yb and Sr neutral lattice standards operated at NIST [60] and JILA [29] in Boulder, USA, or in the Tokyo metropolitan area. Furthermore, if enough such frequency ratios bet…”
BackgroundSpin Squeezing in a Rydberg Lattice Clock
Gil, L. I. R., Mukherjee, R., Bridge, E. M., Jones, M. P. A., & Pohl, T. (2014) · Physical Review Letters · doi:10.1103/physrevlett.112.103601 · Cited by 152
Demonstration of a trapped-ion atomic clock in space
Burt, E. A., Prestage, J. D., Tjoelker, R. L., Enzer, D. G., Kuang, D., Murphy, D. W., Robison, D., Seubert, J., Wang, R. T., & Ely, T. (2021) · Nature · doi:10.1038/s41586-021-03571-7 · Cited by 174
Bohnet, J. G., Cox, K. C., Norcia, M. A., Weiner, J. M., Chen, Z., & Thompson, J. K. (2014) · Nature Photonics · doi:10.1038/nphoton.2014.151 · Cited by 173
Quantum Fisher information for states in exponential form
Jiang, Z. (2014) · Physical Review A · doi:10.1103/physreva.89.032128 · Cited by 157
Search for light scalar dark matter with atomic gravitational wave detectors
Arvanitaki, A., Graham, P. W., Hogan, J. M., Rajendran, S., & Van Tilburg, K. (2018) · Physical Review D · doi:10.1103/physrevd.97.075020 · Cited by 171
Poli, N., Oates, C. W., Gill, P. R., & Tino, G. M. (2014) · arXiv (Cornell University) · doi:10.48550/arxiv.1401.2378 · Cited by 60
Self-citationCompact Optical Atomic Clock Based on a Two-Photon Transition in Rubidium
Martin, K. W., Phelps, G., Lemke, N. D., Bigelow, M. S., Stuhl, B., Wojcik, M., Holt, M., Coddington, I., Bishop, M. W., & Burke, J. H. (2018) · Physical Review Applied · doi:10.1103/physrevapplied.9.014019 · Cited by 169
Self-citationSynchronization of Distant Optical Clocks at the Femtosecond Level
Deschênes, J.-D., Sinclair, L. C., Giorgetta, F. R., Swann, W. C., Baumann, E., Bergeron, H., Cermak, M., Coddington, I., & Newbury, N. R. (2016) · Physical Review X · doi:10.1103/physrevx.6.021016 · Cited by 164
Hartwig, J., Abend, S., Schubert, C., Schlippert, D., Ahlers, H., Posso-Trujillo, K., Gaaloul, N., Ertmer, W. A., & Rasel, E. M. (2015) · New Journal of Physics · doi:10.1088/1367-2630/17/3/035011 · Cited by 160
New bounds on dark matter coupling from a global network of optical atomic clocks
Wcisło, P., Ablewski, P., Beloy, K., Bilicki, S., Bober, M., Brown, R., Fasano, R., Ciuryło, R., Hachisu, H., Ido, T., et al. (2018) · Science Advances · doi:10.1126/sciadv.aau4869 · Cited by 159
Self-citationUltrastable Silicon Cavity in a Continuously Operating Closed-Cycle Cryostat at 4 K
Zhang, W., Robinson, J. M., Sonderhouse, L., Oelker, E., Benko, C., Hall, J. L., Legero, T., Matei, D. G., Riehle, F., Sterr, U., et al. (2017) · Physical Review Letters · doi:10.1103/physrevlett.119.243601 · Cited by 132
Differential clock comparisons with a multiplexed optical lattice clock
Zheng, X., Dolde, J., Lochab, V., Merriman, B. N., Li, H., & Kolkowitz, S. (2022) · Nature · doi:10.1038/s41586-021-04344-y · Cited by 150
Realization of a timescale with an accurate optical lattice clock
Grebing, C., Al-Masoudi, A., Dörscher, S., Häfner, S., Gerginov, V., Weyers, S., Lipphardt, B., Riehle, F., Sterr, U., & Lisdat, C. (2016) · Optica · doi:10.1364/optica.3.000563 · Cited by 149
Low-Frequency Gravitational Wave Searches Using Spacecraft Doppler Tracking
Armstrong, J. W. (2006) · Living Reviews in Relativity · doi:10.12942/lrr-2006-1 · Cited by 148
Origlia, S., Pramod, M. S., Schiller, S., Singh, Y., Bongs, K., Schwarz, R., Al-Masoudi, A., Dörscher, S., Herbers, S., Häfner, S., et al. (2018) · Physical Review A · doi:10.1103/physreva.98.053443 · Cited by 142
Low-loss integrated photonics for the blue and ultraviolet regime
West, G. N., Loh, W., Kharas, D., Sorace-Agaskar, C., Mehta, K. K., Sage, J., Chiaverini, J., & Ram, R. J. (2019) · APL Photonics · doi:10.1063/1.5052502 · Cited by 141
Synthetic Spin-Orbit Coupling in an Optical Lattice Clock
Wall, M. L., Koller, A., Li, S., Zhang, X., Cooper, N. R., Ye, J., & Rey, A. M. (2016) · Physical Review Letters · doi:10.1103/physrevlett.116.035301 · Cited by 141
Highly Charged Ions for Atomic Clocks, Quantum Information, and Search for α variation
Safronova, M. S., Dzuba, V. A., Flambaum, V. V., Safronova, M. S., Porsev, S. G., & Kozlov, M. G. (2014) · Physical Review Letters · doi:10.1103/physrevlett.113.030801 · Cited by 140
Frequency Measurements of Superradiance from the Strontium Clock Transition
Norcia, M. A., Cline, J. R. K., Muniz, J. A., Robinson, J. M., Hutson, R. B., Goban, A., Marti, G. E., Ye, J., & Thompson, J. K. (2018) · Physical Review X · doi:10.1103/physrevx.8.021036 · Cited by 139
Atomic Clock with 1 × 10 − 18 Room-Temperature Blackbody Stark Uncertainty
Beloy, K., Hinkley, N., Phillips, N. B., Sherman, J. A., Schioppo, M., Lehman, J., Feldman, A., Hanssen, L. M., Oates, C. W., & Ludlow, A. D. (2014) · Physical Review Letters · doi:10.1103/physrevlett.113.260801 · Cited by 137
Self-citationDiamond Magnetometry and Gradiometry Towards Subpicotesla dc Field Measurement
Zhang, C., Shagieva, F., Widmann, M., Kübler, M., Vorobyov, V., Kapitanova, P., Nenasheva, E., Corkill, R., Rhrle, O., Nakamura, K., et al. (2021) · Physical Review Applied · doi:10.1103/physrevapplied.15.064075 · Cited by 138
Rushton, J. A., Aldous, M., & Himsworth, M. (2014) · Review of Scientific Instruments · doi:10.1063/1.4904066 · Cited by 135
Cold-Strontium Laser in the Superradiant Crossover Regime
Norcia, M. A., & Thompson, J. K. (2016) · Physical Review X · doi:10.1103/physrevx.6.011025 · Cited by 132
Bayesian quantum frequency estimation in presence of collective dephasing
Macieszczak, K., Fraas, M., & Demkowicz-Dobrzański, R. (2014) · New Journal of Physics · doi:10.1088/1367-2630/16/11/113002 · Cited by 99
A transportable strontium optical lattice clock
Poli, N., Schioppo, M., Vogt, S., Falke, S., Sterr, U., Lisdat, C., & Tino, G. M. (2014) · Applied Physics B · doi:10.1007/s00340-014-5932-9 · Cited by 104
Self-citationQuantum limits on postselected, probabilistic quantum metrology
Combes, J., Ferrie, C., Zhang, J., & Caves, C. M. (2014) · Physical Review A · doi:10.1103/physreva.89.052117 · Cited by 125
Frequency Ratio ofHg199andSr87Optical Lattice Clocks beyond the SI Limit
Yamanaka, K., Ohmae, N., Ushijima, I., Takamoto, M., & Katori, H. (2015) · Physical Review Letters · doi:10.1103/physrevlett.114.230801 · Cited by 104
Operation of an optical atomic clock with a Brillouin laser subsystem
Loh, W., Stuart, J., Reens, D., Bruzewicz, C., Braje, D., Chiaverini, J., Juodawlkis, P., Sage, J., & McConnell, R. (2020) · Nature · doi:10.1038/s41586-020-2981-6 · Cited by 121
Dubé, P., Madej, A. A., Tibbo, M., & Bernard, J. E. (2014) · Physical Review Letters · doi:10.1103/physrevlett.112.173002 · Cited by 106
Narrow laser-linewidth measurement using short delay self-heterodyne interferometry
Zhao, Z., Bai, Z., Jin, D., Qi, Y., Ding, J., Yan, B., Wang, Y., Lü, Z., & Mildren, R. P. (2022) · Optics Express · doi:10.1364/oe.455028 · Cited by 120
Precise study of asymptotic physics with subradiant ultracold molecules
McGuyer, B. H., McDonald, M., Iwata, G. Z., Tarallo, M. G., Skomorowski, W., Moszyński, R., & Zelevinsky, T. (2014) · Nature Physics · doi:10.1038/nphys3182 · Cited by 119
Observation of electric-dipole-forbidden infrared transitions in cold molecular ions
Germann, M., Tong, X., & Willitsch, S. (2014) · Nature Physics · doi:10.1038/nphys3085 · Cited by 119
Experimental constraint on dark matter detection with optical atomic clocks
Wcisło, P., Morzyński, P., Bober, M., Cygan, A., Lisak, D., Ciuryło, R., & Zawada, M. (2016) · Nature Astronomy · doi:10.1038/s41550-016-0009 · Cited by 116
Frequency Comparison of TwoCa+40Optical Clocks with an Uncertainty at the10−17Level
Huang, Y., Guan, H., Liu, P., Bian, W., Ma, L., Liang, K., Li, T., & Gao, K. (2016) · Physical Review Letters · doi:10.1103/physrevlett.116.013001 · Cited by 106
Leopardi, H., Davila-Rodriguez, J., Quinlan, F., Olson, J., Sherman, J. A., Diddams, S. A., & Fortier, T. M. (2017) · Optica · doi:10.1364/optica.4.000879 · Cited by 104
Self-citationCounting the cycles of light using a self-referenced optical microresonator
Jost, J. D., Herr, T., Lecaplain, C., Brasch, V., Pfeiffer, M. H. P., & Kippenberg, T. J. (2015) · Optica · doi:10.1364/optica.2.000706 · Cited by 114
Wang, B., Zhu, X., Gao, C., Bai, Y., Dong, J., & Wang, L. J. (2015) · Scientific Reports · doi:10.1038/srep13851 · Cited by 113
Glukhov, I. L., Mokhnenko, S. N., Nikitina, E. A., & Ovsiannikov, V. D. (2015) · The European Physical Journal D · doi:10.1140/epjd/e2014-50648-6 · Cited by 111
Ultra-narrow linewidth Brillouin laser with nanokelvin temperature self-referencing
Loh, W., Yegnanarayanan, S., O’Donnell, F., & Juodawlkis, P. W. (2019) · Optica · doi:10.1364/optica.6.000152 · Cited by 96
Quantum correlations and entanglement in far-from-equilibrium spin systems
Hazzard, K. R. A., van den Worm, M., Foss‐Feig, M., Manmana, S. R., Torre, E. G. D., Pfau, T., Kästner, M., & Rey, A. M. (2014) · Physical Review A · doi:10.1103/physreva.90.063622 · Cited by 106
Superfluidity and Superconductivity in Neutron Stars
Nicolas Chamel, A. (2017) · Journal of Astrophysics and Astronomy · doi:10.1007/s12036-017-9470-9 · Cited by 105
Temporal solitons in a coherently driven active resonator
Englebert, N., Arabí, C. M., Parra‐Rivas, P., Gorza, S.-P., & Leo, F. (2021) · Nature Photonics · doi:10.1038/s41566-021-00807-w · Cited by 105
Near-Heisenberg-Limited Atomic Clocks in the Presence of Decoherence
Borregaard, J., & Sørensen, A. S. (2013) · Physical Review Letters · doi:10.1103/physrevlett.111.090801 · Cited by 81
Optical to microwave clock frequency ratios with a nearly continuous strontium optical lattice clock
Lodewyck, J., Bilicki, S., Bookjans, E., Robyr, J.-L., Shi, C., Vallet, G., Le Targat, R., Nicolodi, D., Le Coq, Y., Guéna, J., et al. (2016) · Metrologia · doi:10.1088/0026-1394/53/4/1123 · Cited by 102
“duction Over the last years, optical lattice clocks (OLCs) have become the most stable frequency standards, with frequency instabilities as low as 2:2 10 16 in relative units after 1 s of integration [1, 2]. More recently, by reducing the uncertainty on the blackbody radiation induced frequency shift, OLCs with accura…”
BackgroundRaupach, S. M. F., Koczwara, A., & Grosche, G. (2015) · Physical Review A · doi:10.1103/physreva.92.021801 · Cited by 101
Hyperpolarizability and Operational Magic Wavelength in an Optical Lattice Clock
Brown, R. C., Phillips, N. B., Beloy, K., McGrew, W. F., Schioppo, M., Fasano, R. J., Milani, G., Zhang, X., Hinkley, N., Leopardi, H., et al. (2017) · Physical Review Letters · doi:10.1103/physrevlett.119.253001 · Cited by 101
Self-citationLaurent, P., Massonnet, D., Cacciapuoti, L., & Salomon, C. (2015) · Comptes Rendus. Physique · doi:10.1016/j.crhy.2015.05.002 · Cited by 83
Proposal for a room-temperature diamond maser
Jin, L., Pfender, M., Aslam, N., Neumann, P., Yang, S., Wrachtrup, J., & Liu, R. (2015) · Nature Communications · doi:10.1038/ncomms9251 · Cited by 99
Optical phase noise from atmospheric fluctuations and its impact on optical time-frequency transfer
Sinclair, L. C., Giorgetta, F. R., Swann, W. C., Baumann, E., Coddington, I., & Newbury, N. R. (2014) · Physical Review A · doi:10.1103/physreva.89.023805 · Cited by 98
Agreement between two88Sr+optical clocks to 4 parts in 1017
Barwood, G. P., Huang, G., Klein, H. A., Johnson, L. A. M., King, S. A., Margolis, H. S., Szymaniec, K., & Gill, P. (2014) · Physical Review A · doi:10.1103/physreva.89.050501 · Cited by 90
A room temperature optomechanical squeezerPreprint
Aggarwal, N. (2020) · arXiv (Cornell University) · doi:10.48550/arxiv.2006.14323 · Cited by 94
Pulsed optical pumping in electron spin vapor
Pei, H., Pang, H., Quan, W., Fan, W., Yuan, L., Zhang, K., & Fang, C. (2024) · Measurement · doi:10.1016/j.measurement.2024.114619 · Cited by 92
Ultrastable laser with average fractional frequency drift rate below 5 × 10^−19/s
Hagemann, C., Grebing, C., Lisdat, C., Falke, S., Legero, T., Sterr, U., Riehle, F., Martin, M. J., & Ye, J. (2014) · Optics Letters · doi:10.1364/ol.39.005102 · Cited by 77
Denker, H., Timmen, L., Voigt, C., Weyers, S., Peik, E., Margolis, H. S., Delva, P., Wolf, P., & Petit, G. (2018) · Journal of Geodesy · doi:10.1007/s00190-017-1075-1 · Cited by 91
“…orders of magnitude higher than the caesium clocks and thus achieve a higher frequency stability, approaching fractional stabilities and uncertainties of one part in 1018 (Chou et al. 2010; Hinkley et al. 2013; Bloom et al. 2014; Nicholson et al. 2015; Ushijima et al. 2015; Huntemann et al. 2016).”
BackgroundFrequency ratios of Sr, Yb, and Hg based optical lattice clocks and their applications
Takamoto, M., Ushijima, I., Das, M., Nemitz, N., Ohkubo, T., Yamanaka, K., Ohmae, N., Takano, T., Akatsuka, T., Yamaguchi, A., et al. (2015) · Comptes Rendus. Physique · doi:10.1016/j.crhy.2015.04.003 · Cited by 85
Testing physics beyond the standard model through additional clock transitions in neutral ytterbium
Dzuba, V. A., Flambaum, V. V., & Schiller, S. (2018) · Physical Review A · doi:10.1103/physreva.98.022501 · Cited by 90
Zero-Dead-Time Operation of Interleaved Atomic Clocks
Biedermann, G. W., Takase, K., Wu, X., Deslauriers, L., Roy, S., & Kasevich, M. A. (2013) · Physical Review Letters · doi:10.1103/physrevlett.111.170802 · Cited by 70
Loss in long-storage-time optical cavities
Isogai, T., Miller, J., Kwee, P., Barsotti, L., & Evans, M. (2013) · Optics Express · doi:10.1364/oe.21.030114 · Cited by 85
Noise and instability of an optical lattice clock
Al-Masoudi, A., Dörscher, S., Häfner, S., Sterr, U., & Lisdat, C. (2015) · Physical Review A · doi:10.1103/physreva.92.063814 · Cited by 84
DEGENERATE QUANTUM GASES OF STRONTIUM
Stellmer, S., Schreck, F., & Killian, T. C. (2014) · Annual review of cold atoms and molecules · doi:10.1142/9789814590174_0001 · Cited by 82
Quan, R., Zhai, Y., Wang, M., Hou, F., Wang, S., Xiang, X., Liu, T., Zhang, S., & Dong, R. (2016) · Scientific Reports · doi:10.1038/srep30453 · Cited by 82
Beyond 100 THz-spanning ultraviolet frequency combs in a non-centrosymmetric crystalline waveguide
Liu, X., Bruch, A. W., Lu, J., Gong, Z., Surya, J. B., Zhang, L., Wang, J., Yan, J., & Tang, H. X. (2019) · Nature Communications · doi:10.1038/s41467-019-11034-x · Cited by 81
Metadata
- Authors
- Hinkley, N., Sherman, J. A., Phillips, N. B., Schioppo, M., Lemke, N. D., Beloy, K., Pizzocaro, M., Oates, C. W., & Ludlow, A. D.
- Affiliations
- National Institute of Standards and Technology (US)
- Corresponding author
- Ludlow, A. D.
- Venue
- Science
- Published
- 2013-09-13
- Volume
- 341
- Issue
- 6151
- Pages
- 1215-1218
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W2015575484
- Cited by
- 817
- References
- 28
- Citations by year
- 2026: 22 · 2025: 38 · 2024: 46 · 2023: 34 · 2022: 39 · 2021: 45 · 2020: 45 · 2019: 57 · 2018: 58 · 2017: 63 · 2016: 99 · 2015: 145 · 2014: 111 · 2013: 14
- FWCI
- 63.43
- Type
- journal article
- Language
- en
- Open access
- green
- arxiv.org
- Locations
- Science (publishedVersion)
- PubMed (publishedVersion)
- arXiv (Cornell University) (submittedVersion)
- CINECA IRIS Institutional Research Information System (IRIS Istituto Nazionale di Ricerca Metrologica) (submittedVersion)
- arXiv (Cornell University) (public-domain)
- Science
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Frequency and Time Standards
- Physical Sciences › Computer Science › Computer Networks and Communications › Network Time Synchronization Technologies
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Cold Atom Physics and Bose-Einstein Condensates
- Keywords
- optical lattice clock, ytterbium, relativistic geodesy, navigation, beyond the Standard Model
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.