An Atomic Clock with 10 –18 Instability
Open accessThe DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
Tick, Tick, Tick…: Many aspects of everyday life from communication to navigation rely on the precise ticking of the microwave transitions of the atoms in atomic clocks. Optical transitions occur at much higher frequency and so offer the opportunity to reduce the scale of the ticks even more. Hinkley et al. (p. 1215 , published online 22 August; see the Perspective by Margolis ) compare the ticking of two optical clocks and report an instability near the 10 −18 level. Such performance will improve tests of general relativity and pave the way for a redefinition of the second.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The frequency stability and uncertainty of the latest generation of optical atomic clocks is now approaching the one part in 10 18 level.”
From Geodetic methods to determine the relativistic redshift at the level of 10 $$^{-18}$$ - 18 in the context of international timescales: a review and practical results (2018) · cites this paper as Hinkley et al. 2013
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The optical clocks operate at frequencies about five orders of magnitude higher than the caesium clocks and thus achieve a higher frequency stability, approaching fractional stabilities and uncertainties of one part in 10 18 (Chou et al. 2010;Hinkley et al. 2013;Bloom et al. 2014;Nicholson et al. 2015;Ushijima et al. 2015;Huntemann et al. 2016).”
From Geodetic methods to determine the relativistic redshift at the level of 10 $$^{-18}$$ - 18 in the context of international timescales: a review and practical results (2018) · cites this paper as Hinkley et al. 2013
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“To date, the best of these instruments reach a stability of 1 . 6 × 10 -18 (NIST, RIKEN + Univ. Tokyo, Hinkley et al. 2013) after 7 hours of integration time.”
From Determination of a high spatial resolution geopotential model using atomic clock comparisons (2017) · cites this paper as Hinkley et al. 2013
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“Optical clocks are—due to their orders of magnitude better precision1 and accuracy234 than their microwave counterparts realizing the definition of the SI-second—new sensors with highest resolving power”
From A clock network for geodesy and fundamental science (2016) · cites this paper as [1]
The cited source says what the claim attributes to it.
In the citing paper
“This demonstrates that use of a state-of-the-art OLO affords unprecedented optical clock stability 10-15 .”
From Ultrastable optical clock with two cold-atom ensembles (2017) · cites this paper as [11]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Frequency Ratio of Al+and Hg+Single-Ion Optical Clocks; Metrology at the 17th Decimal Place
Rosenband, T., Hume, D. B., Schmidt, P. O., Chou, C. W., Brusch, A., Lorini, L., Oskay, W. H., Drullinger, R. E., Fortier, T. M., Stalnaker, J. E., et al. (2008) · Science · doi:10.1126/science.1154622 · Cited by 1,450
Frequency Comparison of Two High-Accuracy Al + Optical Clocks
Chou, C., Hume, D., Koelemeij, J., Wineland, D., & Rosenband, T. (2010) · Physical Review Letters · doi:10.1103/physrevlett.104.070802 · Cited by 903
Chou, C. W., Hume, D. B., Rosenband, T., & Wineland, D. J. (2010) · Science · doi:10.1126/science.1192720 · Cited by 828
A sub-40-mHz-linewidth laser based on a silicon single-crystal optical cavity
Kessler, T., Hagemann, C., Grebing, C., Legero, T., Sterr, U., Riehle, F., Martin, M. J., Chen, L., & Ye, J. (2012) · Nature Photonics · doi:10.1038/nphoton.2012.217 · Cited by 754
Quantum projection noise: Population fluctuations in two-level systems
Itano, W. M., Bergquist, J. C., Bollinger, J. J., Gilligan, J. M., Heinzen, D. J., Moore, F. L., Raizen, M. G., & Wineland, D. J. (1993) · Physical Review A · doi:10.1103/physreva.47.3554 · Cited by 613
Ultrastable Optical Clock with Neutral Atoms in an Engineered Light Shift Trap
Katori, H., Takamoto, M., Pal’chikov, V. G., & Ovsiannikov, V. D. (2003) · Physical Review Letters · doi:10.1103/physrevlett.91.173005 · Cited by 572
Implementation of Cavity Squeezing of a Collective Atomic Spin
Leroux, I. D., Schleier-Smith, M. H., & Vuletić, V. (2010) · Physical Review Letters · doi:10.1103/physrevlett.104.073602 · Cited by 541
Making optical atomic clocks more stable with 10−16-level laser stabilization
Jiang, Y. Y., Ludlow, A. D., Lemke, N. D., Fox, R. W., Sherman, J. A., Ma, L.-S., & Oates, C. W. (2011) · Nature Photonics · doi:10.1038/nphoton.2010.313 · Cited by 462
Self-citationQuantum State Engineering and Precision Metrology Using State-Insensitive Light Traps
Ye, J., Kimble, H. J., & Katori, H. (2008) · Science · doi:10.1126/science.1148259 · Cited by 419
Tenfold reduction of Brownian noise in high-reflectivity optical coatings
Cole, G. D., Zhang, W., Martin, M. J., Ye, J., & Aspelmeyer, M. (2013) · Nature Photonics · doi:10.1038/nphoton.2013.174 · Cited by 382
Research works printed but not linked: 1
- G. J. Dick J. D. Prestage C. A. Greenhall L. Maleki in Proceedings of the 22nd Precise Time and Time Interval Meeting (NASA Conference Publication 3116 Washington DC 1990) pp. 487–508.
Cited by
Items 201–300 of 938
High-precision spectroscopy of ultracold molecules in an optical lattice
McGuyer, B. H., McDonald, M., Iwata, G. Z., Tarallo, M. G., Grier, A. T., Apfelbeck, F. A. C., & Zelevinsky, T. (2015) · New Journal of Physics · doi:10.1088/1367-2630/17/5/055004 · Cited by 40
Optical injection locking-based amplification in phase-coherent transfer of optical frequencies
Kim, J.-Y., Schnatz, H., Wu, D. S., Marra, G., Richardson, D. J., & Slavík, R. (2015) · Optics Letters · doi:10.1364/ol.40.004198 · Cited by 40
Measurement of the Yb I S01−P11 transition frequency at 399 nm using an optical frequency comb
Kleinert, M., Dahl, M. E. G., & Bergeson, S. (2016) · Physical Review A · doi:10.1103/physreva.94.052511 · Cited by 40
Laser controlled atom source for optical clocks
Kock, O., He, W. J., Świerad, D., Smith, L., Hughes, J., Bongs, K., & Singh, Y. (2016) · Scientific Reports · doi:10.1038/srep37321 · Cited by 40
Quantum clocks and their synchronisation - the Alternate Ticks GamePreprint
Ranković, S., Liang, Y.-C., & Renner, R. (2015) · arXiv (Cornell University) · doi:10.48550/arxiv.1506.01373 · Cited by 41
Ultra-precise optical phase-locking approach for ultralow noise frequency comb generation
Deng, Z., Liu, Y., Zhu, Z., Luo, D., Gu, C., Zhou, L., Xie, G., & Li, W. (2021) · Optics & Laser Technology · doi:10.1016/j.optlastec.2020.106906 · Cited by 39
Zameroski, N. D., Hager, G. D., Erickson, C., & Burke, J. H. (2014) · Journal of Physics B Atomic Molecular and Optical Physics · doi:10.1088/0953-4075/47/22/225205 · Cited by 39
Direct loading of a large Yb MOT on the 1 S 0 → 3 P 1 transition
Guttridge, A., Hopkins, S. A., Kemp, S. L., Boddy, D., Freytag, R., Jones, M. P. A., Tarbutt, M. R., Hinds, E. A., & Cornish, S. L. (2016) · Journal of Physics B Atomic Molecular and Optical Physics · doi:10.1088/0953-4075/49/14/145006 · Cited by 39
Cold atoms: A field enabled by light
Fallani, L., & Kastberg, A. (2015) · Europhysics Letters (EPL) · doi:10.1209/0295-5075/110/53001 · Cited by 38
Bober, M., Morzyński, P., Cygan, A., Lisak, D., Masłowski, P., Prymaczek, M., Wcisło, P., Ablewski, P., Piwiński, M., Wójtewicz, S., et al. (2015) · Measurement Science and Technology · doi:10.1088/0957-0233/26/7/075201 · Cited by 38
Efficient frequency doubling at 399 nm
Pizzocaro, M., Calonico, D., Pastor, P. C., Catani, J., Costanzo, G. A., Levi, F., & Lorini, L. (2014) · Applied Optics · doi:10.1364/ao.53.003388 · Cited by 38
Self-citationQuantum Algorithmic Readout in Multi-Ion Clocks
Schulte, M. T., Lörch, N., Leroux, I. D., Schmidt, P. O., & Hammerer, K. (2016) · Physical Review Letters · doi:10.1103/physrevlett.116.013002 · Cited by 38
Polarizabilities of theSr87clock transition
Shi, C., Robyr, J.-L., Eismann, U., Zawada, M., Lorini, L., Le Targat, R., & Lodewyck, J. (2015) · Physical Review A · doi:10.1103/physreva.92.012516 · Cited by 37
Visible blue-to-red 10 GHz frequency comb via on-chip triple-sum-frequency generation
Obrzud, E., Brasch, V., Voumard, T., Stroganov, A., Geiselmann, M., Wildi, F. P., Pepe, F. A., Lecomte, S., & Herr, T. (2019) · Optics Letters · doi:10.1364/ol.44.005290 · Cited by 37
Efficient and tunable blue light generation using lithium niobate nonlinear photonics
Sayem, A. A., Wang, Y., Lu, J., Liu, X., Bruch, A. W., & Tang, H. X. (2021) · Applied Physics Letters · doi:10.1063/5.0071769 · Cited by 37
Entanglement and spin squeezing in a network of distant optical lattice clocks
Polzik, E. S., & Ye, J. (2016) · Physical Review A · doi:10.1103/physreva.93.021404 · Cited by 37
Chabuda, K., Leroux, I. D., & Demkowicz-Dobrzański, R. (2016) · New Journal of Physics · doi:10.1088/1367-2630/18/8/083035 · Cited by 37
Current state of the art in small mass and force metrology within the International System of Units
Shaw, G. A. (2018) · Measurement Science and Technology · doi:10.1088/1361-6501/aaac51 · Cited by 36
Influence of relativistic effects on satellite-based clock synchronization
Wang, J., Tian, Z., Jing, J., & Fan, H. (2016) · Physical review. D/Physical review. D. · doi:10.1103/physrevd.93.065008 · Cited by 36
Nonlinear spectroscopy of Sr atoms in an optical cavity for laser stabilization
Christensen, B. T. R., Henriksen, M. R., Schäffer, S. A., Westergaard, P. G., Tieri, D., Ye, J., Holland, M., & Thomsen, J. W. (2015) · Physical Review A · doi:10.1103/physreva.92.053820 · Cited by 35
Quan, R., Dong, R., Zhai, Y., Hou, F., Xiang, X., Zhou, H., Lv, C., Wang, Z., You, L., Liu, T., et al. (2019) · Optics Letters · doi:10.1364/ol.44.000614 · Cited by 35
Production of Rubidium Bose-Einstein Condensates at a 1 Hz RatePreprint
Farkas, D., Salim, E. A., & Ramirez-Serrano, J. (2014) · arXiv (Cornell University) · doi:10.48550/arxiv.1403.4641 · Cited by 35
Collectively enhanced Ramsey readout by cavity sub- to superradiant transition
Bohr, E. A., Kristensen, S. L., Hotter, C., Schäffer, S. A., Robinson-Tait, J., Thomsen, J. W., Zelevinsky, T., Ritsch, H., & Müller, J. H. (2024) · Nature Communications · doi:10.1038/s41467-024-45420-x · Cited by 34
Incorporating an Optical Clock Into a Time Scale
Yao, J., Parker, T. E., Ashby, N., & Levine, J. (2017) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2017.2773530 · Cited by 34
Continuous Real-Time Tracking of a Quantum Phase Below the Standard Quantum Limit
Shankar, A., Greve, G. P., Wu, B., Thompson, J. K., & Holland, M. (2019) · Physical Review Letters · doi:10.1103/physrevlett.122.233602 · Cited by 34
Electron and recoil ion momentum imaging with a magneto-optically trapped target
Hubele, R., Schuricke, M., Goullon, J., Lindenblatt, H., Ferreira, N., LaForge, A. C., Brühl, E., de Jesus, V. L. B., Globig, D., Kelkar, A. H., et al. (2015) · Review of Scientific Instruments · doi:10.1063/1.4914040 · Cited by 34
Margolis, H. (2014) · Nature Physics · doi:10.1038/nphys2834 · Cited by 33
Westergaard, P. G., Christensen, B. T. R., Tieri, D., Matin, R., Cooper, J., Holland, M., Ye, J., & Thomsen, J. W. (2015) · Physical Review Letters · doi:10.1103/physrevlett.114.093002 · Cited by 33
Liang, D., Zhang, H., Liu, K., Liu, D., & Wang, R. (2022) · IEEE Geoscience and Remote Sensing Magazine · doi:10.1109/mgrs.2022.3189005 · Cited by 33
Stable Optical Frequency Comb Distribution Enabled by Hollow‐Core Fibers
Feng, Z., Marra, G., Zhang, X., Fokoua, E. N., Sakr, H., Hayes, J. R., Poletti, F., Richardson, D. J., & Slavík, R. (2022) · Laser & Photonics Review · doi:10.1002/lpor.202200167 · Cited by 33
Quantum estimation of magnetic-field gradient using W-state
Ng, H. T., & Kim, K. (2014) · Optics Communications · doi:10.1016/j.optcom.2014.06.048 · Cited by 33
Avoiding Aliasing in Allan Variance: An Application to Fiber Link Data Analysis
Calosso, C. E., Clivati, C., & Micalizio, S. (2016) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2016.2519265 · Cited by 33
Fast and Scalable Quantum Information Processing with Two‐Electron Atoms in Optical Tweezer Arrays
Pagano, G., Scazza, F., & Foss‐Feig, M. (2019) · Advanced Quantum Technologies · doi:10.1002/qute.201800067 · Cited by 33
Krehlik, P., Schnatz, H., & Śliwczyński, Ł. (2017) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2017.2759001 · Cited by 33
Chirped frequency transfer: A tool for synchronization and time transfer
Raupach, S. M. F., & Grosche, G. (2014) · IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control · doi:10.1109/tuffc.2014.2988 · Cited by 32
Evaluating Optical Clock Performance for GNSS Positioning
Boldbaatar, E., Grant, D., Choy, S., Zaminpardaz, S., & Holden, L. (2023) · Sensors · doi:10.3390/s23135998 · Cited by 32
Paez, E. J., Arnold, K. J., Hajiyev, E., Porsev, S. G., Dzuba, V. A., Safronova, M. S., Safronova, M. S., & Barrett, M. D. (2016) · Physical Review A · doi:10.1103/physreva.93.042112 · Cited by 32
Two-photon E1 - M1 optical clock
Alden, E. A., Moore, K., & Leanhardt, A. E. (2014) · Physical Review A · doi:10.1103/physreva.90.012523 · Cited by 32
Yu, Y., & Sahoo, B. K. (2016) · Physical Review A · doi:10.1103/physreva.94.062502 · Cited by 32
Kobayashi, T., Akamatsu, D., Hosaka, K., Inaba, H., Okubo, S., Tanabe, T., Yasuda, M., Onae, A., & Hong, F.-L. (2016) · Journal of the Optical Society of America B · doi:10.1364/josab.33.000725 · Cited by 31
Atomic Quantum Technologies for Quantum Matter and Fundamental Physics Applications
Malo, J. Y., Lepori, L., Gentini, L., & Chiofalo, M. L. (2024) · Technologies · doi:10.3390/technologies12050064 · Cited by 31
Uncertainty Evaluation of an 171Yb Optical Lattice Clock at NMIJ
Kobayashi, T., Akamatsu, D., Hisai, Y., Tanabe, T., Inaba, H., Suzuyama, T., Hong, F.-L., Hosaka, K., & Yasuda, M. (2018) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2018.2870937 · Cited by 31
Active optical frequency standards using cold atoms: Perspectives and challenges
Kazakov, G. A., & Schumm, T. (2014) · European Frequency and Time Forum · doi:10.1109/eftf.2014.7331523 · Cited by 31
Optical atomic clock comparison through turbulent air
Bodine, M. I., Deschênes, J.-D., Khader, I. H., Swann, W. C., Leopardi, H., Beloy, K., Bothwell, T., Brewer, S. M., Bromley, S., Chen, J.-S., et al. (2020) · Physical Review Research · doi:10.1103/physrevresearch.2.033395 · Cited by 30
Self-citationVernier microcombs for high-frequency carrier envelope offset and repetition rate detection
Wu, K., O’Malley, N. P., Fatema, S., Wang, C., Girardi, M., Alshaykh, M. S., Ye, Z., Leaird, D. E., Qi, M., & Weiner, A. M. (2023) · Optica · doi:10.1364/optica.486755 · Cited by 30
Two-color magneto-optical trap with small magnetic field for ytterbium
Kawasaki, A., Braverman, B., Yu, Q., & Vuletić, V. (2015) · Journal of Physics B Atomic Molecular and Optical Physics · doi:10.1088/0953-4075/48/15/155302 · Cited by 30
Space-time reference with an optical link
Berceau, P., Taylor, M., Kahn, J. M., & Hollberg, L. W. (2016) · Classical and Quantum Gravity · doi:10.1088/0264-9381/33/13/135007 · Cited by 30
Endo, M., & Schibli, T. R. (2018) · OSA Continuum · doi:10.1364/osac.1.000116 · Cited by 30
Pinkert, T. J., Böll, O., Willmann, L., Jansen, G. S. M., Dijck, E., Groeneveld, B. G. H. M., Smets, R., Bosveld, F. C., Ubachs, W., Jungmann, K. P., et al. (2015) · Applied Optics · doi:10.1364/ao.54.000728 · Cited by 30
Linear-response theory for superradiant lasers
Bohnet, J., Chen, Z., Weiner, J. M., Cox, K. C., & Thompson, J. K. (2014) · Physical Review A · doi:10.1103/physreva.89.013806 · Cited by 30
Geometric Reference Systems in Geodesy (2006 edition)
Jekeli, C. (2006) · The Knowledge Bank (The Ohio State University) · Cited by 30
Shen, Z., Shen, W.-B., & Zhang, S. (2016) · Geophysical Journal International · doi:10.1093/gji/ggw198 · Cited by 29
Realization of a Fast Triple-Magic All-Optical Qutrit in Sr 88
Ammenwerth, M., Timme, H., Gyger, F., Tao, R., Bloch, I., & Zeiher, J. (2025) · Physical Review Letters · doi:10.1103/4kdl-xcwz · Cited by 29
Synthetic frequency protocol for Ramsey spectroscopy of clock transitions
Yudin, V. I., Taǐchenachev, A. V., Basalaev, M. Y., & Zanon-Willette, T. (2016) · Physical Review A · doi:10.1103/physreva.94.052505 · Cited by 29
Microrod Optical Frequency Reference in the Ambient Environment
Zhang, W., Baynes, F., Diddams, S. A., & Papp, S. B. (2019) · Physical Review Applied · doi:10.1103/physrevapplied.12.024010 · Cited by 29
High-Precision Time-Frequency Signal Simultaneous Transfer System via a WDM-Based Fiber Link
Zang, Q., Quan, H., Zhao, K., Zhang, X., Deng, X., Xue, W., Chen, F., Liu, T., Dong, R., & Zhang, S. (2021) · Photonics · doi:10.3390/photonics8080325 · Cited by 29
Integrated Polarization-Splitting Grating Coupler for Chip-Scale Atomic Magnetometer
Hu, J., Lu, J., Liang, Z., Liu, L., Wang, W., Zhou, P., & Ye, M. (2022) · Biosensors · doi:10.3390/bios12070529 · Cited by 29
On-chip optical lattice for cold atom experiments
Straatsma, C., Ivory, M., Duggan, J., Ramirez-Serrano, J., Anderson, D. Z., & Salim, E. A. (2015) · Optics Letters · doi:10.1364/ol.40.003368 · Cited by 29
Highly charged ions for atomic clocks and search for variation of the fine structure constant
Dzuba, V. A., & Flambaum, V. V. (2015) · Hyperfine Interactions · doi:10.1007/s10751-015-1166-4 · Cited by 28
Dai, X., Jiang, Y., Hang, C., Bi, Z., & Ma, L.-S. (2015) · Optics Express · doi:10.1364/oe.23.005134 · Cited by 28
Optical atomic clocks with suppressed blackbody-radiation shift
Kozlov, A., Dzuba, V. A., & Flambaum, V. V. (2014) · Physical Review A · doi:10.1103/physreva.90.042505 · Cited by 28
Cryogenic optical lattice clocks with a relative frequency difference of $1\times 10^{-18}$Preprint
Ushijima, I., Takamoto, M., Das, M., Ohkubo, T., & Katori, H. (2014) · arXiv (Cornell University) · doi:10.48550/arxiv.1405.4071 · Cited by 28
Toward a New Generation of Compact Transportable Yb+ Optical Clocks
Khabarova, K. Y., Kryuchkov, D. S., Borisenko, A., Zalivako, I. V., Semerikov, I. A., Aksenov, M. A., Sherstov, I., Abbasov, T., Tausenev, A. V., & Kolachevsky, N. (2022) · Symmetry · doi:10.3390/sym14102213 · Cited by 27
Leibrandt, D. R., Thorpe, M. J., Chou, C. W., Fortier, T. M., Diddams, S. A., & Rosenband, T. (2013) · Physical Review Letters · doi:10.1103/physrevlett.111.237402 · Cited by 27
High-efficiency cold-atom transport into a waveguide trap
Hilton, A. P., Perrella, C., Benabid, F., Sparkes, B. M., Luiten, A. N., & Light, P. S. (2018) · Physical Review Applied · doi:10.1103/physrevapplied.10.044034 · Cited by 27
Transportable optical atomic clocks for use in out-of-the-lab environments
Gellesch, M., Jones, J., Barron, R., Singh, A., Sun, Q., Bongs, K., & Singh, Y. (2020) · Advanced Optical Technologies · doi:10.1515/aot-2020-0023 · Cited by 26
Secondary laser cooling and capturing of thulium atoms in traps
Сукачев, Д. Д., Калганова, Е. С., Соколов, А. В., Fedorov, S. A., Vishnyakova, G. A., Akimov, A. V., Kolachevsky, N., & Сорокин, В. Н. (2014) · Quantum Electronics · doi:10.1070/qe2014v044n06abeh015392 · Cited by 26
Compact Yb+optical atomic clock project: design principle and current status
Lacroûte, C., Souidi, M., Bourgeois, P.-Y., Millo, J., Saleh, K., Bigler, E., Boudot, R., Giordano, V., & Kersalé, Y. (2016) · Journal of Physics Conference Series · doi:10.1088/1742-6596/723/1/012025 · Cited by 26
Kobayashi, T., Akamatsu, D., Nishida, Y., Tanabe, T., Yasuda, M., Hong, F.-L., & Hosaka, K. (2016) · Optics Express · doi:10.1364/oe.24.012142 · Cited by 26
An approach to directly probe simultaneity
Kipreos, E. T., & Balachandran, R. S. (2016) · Modern Physics Letters A · doi:10.1142/s0217732316501571 · Cited by 26
Realization of Closed-Loop Operation of Optical Lattice Clock Based on 171 Yb
Liu, H., Zhang, X., Jiang, K., Wang, J., Zhu, Q., Xiong, Z.-X., He, L., & Lyu, B. (2017) · Chinese Physics Letters · doi:10.1088/0256-307x/34/2/020601 · Cited by 26
High mechanical bandwidth fiber-coupled Fabry-Perot cavity
Janitz, E., Ruf, M., Fontana, Y., Sankey, J. C., & Childress, L. (2017) · Optics Express · doi:10.1364/oe.25.020932 · Cited by 26
Du, Y., Li, W., Ge, Y., Li, H., Deng, K., & Lu, Z. H. (2017) · Review of Scientific Instruments · doi:10.1063/1.5001489 · Cited by 26
Time keeping and searching for new physics using metastable states of Cu, Ag, and Au
Dzuba, V. A., Allehabi, S. O., Flambaum, V. V., Li, J., & Schiller, S. (2021) · Physical Review A · doi:10.1103/physreva.103.022822 · Cited by 26
Escalé, M. R., Kaufmann, F., Jiang, H., Pohl, D., & Grange, R. (2020) · APL Photonics · doi:10.1063/5.0028776 · Cited by 26
Injection locking of a high power ultraviolet laser diode for laser cooling of ytterbium atoms
Hosoya, T., Miranda, M., Inoue, R., & Kozuma, M. (2015) · Review of Scientific Instruments · doi:10.1063/1.4927132 · Cited by 26
Wide-bandwidth Pound–Drever–Hall locking through a single-sideband modulator
Gatti, D., Gotti, R., Sala, T., Coluccelli, N., Belmonte, M., Prevedelli, M., Laporta, P., & Marangoni, M. (2015) · Optics Letters · doi:10.1364/ol.40.005176 · Cited by 26
Tang, Y.-B., Li, C., & Qiao, H. (2014) · Chinese Physics B · doi:10.1088/1674-1056/23/6/063101 · Cited by 26
Shen, Z., Shen, W.-B., & Zhang, S. (2017) · Surveys in Geophysics · doi:10.1007/s10712-017-9414-6 · Cited by 25
New atomic probes for dark matter detection: Axions, axion-like particles and topological defects
Stadnik, Y. V., & Flambaum, V. V. (2014) · Modern Physics Letters A · doi:10.1142/s0217732314400070 · Cited by 25
A re-evaluation of the relativistic redshift on frequency standards at NIST, Boulder, Colorado, USA
Pavlis, N. K., & Weiss, M. A. (2017) · Metrologia · doi:10.1088/1681-7575/aa765c · Cited by 19
Kajtoch, D., Witkowska, E., & Sinatra, A. (2018) · Europhysics Letters (EPL) · doi:10.1209/0295-5075/123/20012 · Cited by 25
Xin, N. C., Qin, H. R., Miao, S. N., Chen, Y. T., Zheng, Y., Han, J. Z., Zhang, J., & Wang, L. J. (2022) · Optics Express · doi:10.1364/oe.453423 · Cited by 25
Cox, K. C., Greve, G. P., Wu, B., & Thompson, J. K. (2016) · Physical Review A · doi:10.1103/physreva.94.061601 · Cited by 25
Adiabatic control of atomic dressed states for transport and sensing
Cooper, N. R., & Rey, A. M. (2015) · Physical Review A · doi:10.1103/physreva.92.021401 · Cited by 24
Optical-frequency-comb generation with collinear acousto-optic diffraction: Theory and simulations
Mantsevich, S. N., Voloshin, A., & Yushkov, K. B. (2019) · Physical Review A · doi:10.1103/physreva.100.013829 · Cited by 24
Quantum time dilation in atomic spectra
Grochowski, P. T., Smith, A. R. H., Dragan, A., & Dębski, K. (2021) · Physical Review Research · doi:10.1103/physrevresearch.3.023053 · Cited by 24
Cold atom clocks and their applications in precision measurements*
Dai, S., Zheng, F., Liu, K., Chen, W., Lin, Y., Li, T., & Fang, F. (2020) · Chinese Physics B · doi:10.1088/1674-1056/abbbee · Cited by 24
Active stabilization of a diode laser injection lock
Saxberg, B., Plotkin-Swing, B., & Gupta, S. (2016) · Review of Scientific Instruments · doi:10.1063/1.4953589 · Cited by 24
Comparison between 403 nm and 497 nm repumping schemes for strontium magneto-optical traps
Moriya, P. H., Araujo, M., Todão, F. R., Hemmerling, M., Keßler, H., Shiozaki, R. F., Teixeira, R., & Courteille, P. W. (2018) · Journal of Physics Communications · doi:10.1088/2399-6528/aaf662 · Cited by 24
Doppler-stabilized fiber link with 6 dB noise improvement below the classical limit
Calosso, C. E., Bertacco, E. K., Calonico, D., Clivati, C., Costanzo, G. A., Frittelli, M., Levi, F., Micalizio, S., Mura, A., & Godone, A. (2015) · Optics Letters · doi:10.1364/ol.40.000131 · Cited by 23
Grating magneto-optical traps with complicated level structures
Barker, D. S., Elgee, P. K., Sitaram, A., Norrgard, E. B., Klimov, N. N., Campbell, G. K., & Eckel, S. (2023) · New Journal of Physics · doi:10.1088/1367-2630/ad02ea · Cited by 23
Optical frequency dissemination for metrology applications
Droste, S., Udem, T., Holzwarth, R., & Hänsch, T. W. (2015) · Comptes Rendus Physique · doi:10.1016/j.crhy.2015.03.011 · Cited by 23
Scalar static polarizabilities of lanthanides and actinides
Dzuba, V. A., Kozlov, A., & Flambaum, V. V. (2014) · Physical Review A · doi:10.1103/physreva.89.042507 · Cited by 23
Progress on accurate measurement of the Planck constant: Watt balance and counting atoms
Li, S., Zhang, Z., Zhao, W. G., Li, Z., & Huang, S. (2015) · Chinese Physics B · doi:10.1088/1674-1056/24/1/010601 · Cited by 23
Optoelectronic Oscillator Based on Polarization Modulation
Pan, S., Zhou, P., Tang, Z., Zhang, Y., Zhang, F., & Zhu, D. (2015) · Fiber & Integrated Optics · doi:10.1080/01468030.2014.967895 · Cited by 23
High efficiency Raman memory by suppressing radiation trapping
Thomas, S. E., Munns, J. H. D., Kaczmarek, K. T., Qiu, C., Brecht, B., Feizpour, A., Ledingham, P. M., Walmsley, I. A., Nunn, J., & Saunders, D. J. (2017) · New Journal of Physics · doi:10.1088/1367-2630/aa7534 · Cited by 23
Shen, Z., Shen, W., Zhao, P., Liu, T., Zhang, S., & Chao, D. (2019) · Journal of Earth Science · doi:10.1007/s12583-018-0834-0 · Cited by 24
Didier, A., Ignatovich, S., Benkler, E., Okhapkin, M. V., & Mehlstäubler, T. E. (2019) · Optics Letters · doi:10.1364/ol.44.001781 · Cited by 23
Cancellation of collisional frequency shifts in optical lattice clocks with Rabi spectroscopy
Lee, S., Park, C. Y., Lee, W.-K., & Yu, D.-H. (2016) · New Journal of Physics · doi:10.1088/1367-2630/18/3/033030 · Cited by 22
Metadata
- Authors
- Hinkley, N., Sherman, J. A., Phillips, N. B., Schioppo, M., Lemke, N. D., Beloy, K., Pizzocaro, M., Oates, C. W., & Ludlow, A. D.
- Affiliations
- National Institute of Standards and Technology (US)
- Corresponding author
- Ludlow, A. D.
- Venue
- Science
- Published
- 2013-09-13
- Volume
- 341
- Issue
- 6151
- Pages
- 1215-1218
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W2015575484
- Cited by
- 817
- References
- 28
- Citations by year
- 2026: 22 · 2025: 38 · 2024: 46 · 2023: 34 · 2022: 39 · 2021: 45 · 2020: 45 · 2019: 57 · 2018: 58 · 2017: 63 · 2016: 99 · 2015: 145 · 2014: 111 · 2013: 14
- FWCI
- 63.43
- Type
- journal article
- Language
- en
- Open access
- green
- arxiv.org
- Locations
- Science (publishedVersion)
- PubMed (publishedVersion)
- arXiv (Cornell University) (submittedVersion)
- CINECA IRIS Institutional Research Information System (IRIS Istituto Nazionale di Ricerca Metrologica) (submittedVersion)
- arXiv (Cornell University) (public-domain)
- Science
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Frequency and Time Standards
- Physical Sciences › Computer Science › Computer Networks and Communications › Network Time Synchronization Technologies
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Cold Atom Physics and Bose-Einstein Condensates
- Keywords
- optical lattice clock, ytterbium, relativistic geodesy, navigation, beyond the Standard Model
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.