An Atomic Clock with 10 –18 Instability
Open accessThe DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
Tick, Tick, Tick…: Many aspects of everyday life from communication to navigation rely on the precise ticking of the microwave transitions of the atoms in atomic clocks. Optical transitions occur at much higher frequency and so offer the opportunity to reduce the scale of the ticks even more. Hinkley et al. (p. 1215 , published online 22 August; see the Perspective by Margolis ) compare the ticking of two optical clocks and report an instability near the 10 −18 level. Such performance will improve tests of general relativity and pave the way for a redefinition of the second.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The frequency stability and uncertainty of the latest generation of optical atomic clocks is now approaching the one part in 10 18 level.”
From Geodetic methods to determine the relativistic redshift at the level of 10 $$^{-18}$$ - 18 in the context of international timescales: a review and practical results (2018) · cites this paper as Hinkley et al. 2013
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The optical clocks operate at frequencies about five orders of magnitude higher than the caesium clocks and thus achieve a higher frequency stability, approaching fractional stabilities and uncertainties of one part in 10 18 (Chou et al. 2010;Hinkley et al. 2013;Bloom et al. 2014;Nicholson et al. 2015;Ushijima et al. 2015;Huntemann et al. 2016).”
From Geodetic methods to determine the relativistic redshift at the level of 10 $$^{-18}$$ - 18 in the context of international timescales: a review and practical results (2018) · cites this paper as Hinkley et al. 2013
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“To date, the best of these instruments reach a stability of 1 . 6 × 10 -18 (NIST, RIKEN + Univ. Tokyo, Hinkley et al. 2013) after 7 hours of integration time.”
From Determination of a high spatial resolution geopotential model using atomic clock comparisons (2017) · cites this paper as Hinkley et al. 2013
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“Optical clocks are—due to their orders of magnitude better precision1 and accuracy234 than their microwave counterparts realizing the definition of the SI-second—new sensors with highest resolving power”
From A clock network for geodesy and fundamental science (2016) · cites this paper as [1]
The cited source says what the claim attributes to it.
In the citing paper
“This demonstrates that use of a state-of-the-art OLO affords unprecedented optical clock stability 10-15 .”
From Ultrastable optical clock with two cold-atom ensembles (2017) · cites this paper as [11]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Frequency Ratio of Al+and Hg+Single-Ion Optical Clocks; Metrology at the 17th Decimal Place
Rosenband, T., Hume, D. B., Schmidt, P. O., Chou, C. W., Brusch, A., Lorini, L., Oskay, W. H., Drullinger, R. E., Fortier, T. M., Stalnaker, J. E., et al. (2008) · Science · doi:10.1126/science.1154622 · Cited by 1,450
Frequency Comparison of Two High-Accuracy Al + Optical Clocks
Chou, C., Hume, D., Koelemeij, J., Wineland, D., & Rosenband, T. (2010) · Physical Review Letters · doi:10.1103/physrevlett.104.070802 · Cited by 903
Chou, C. W., Hume, D. B., Rosenband, T., & Wineland, D. J. (2010) · Science · doi:10.1126/science.1192720 · Cited by 828
A sub-40-mHz-linewidth laser based on a silicon single-crystal optical cavity
Kessler, T., Hagemann, C., Grebing, C., Legero, T., Sterr, U., Riehle, F., Martin, M. J., Chen, L., & Ye, J. (2012) · Nature Photonics · doi:10.1038/nphoton.2012.217 · Cited by 754
Quantum projection noise: Population fluctuations in two-level systems
Itano, W. M., Bergquist, J. C., Bollinger, J. J., Gilligan, J. M., Heinzen, D. J., Moore, F. L., Raizen, M. G., & Wineland, D. J. (1993) · Physical Review A · doi:10.1103/physreva.47.3554 · Cited by 613
Ultrastable Optical Clock with Neutral Atoms in an Engineered Light Shift Trap
Katori, H., Takamoto, M., Pal’chikov, V. G., & Ovsiannikov, V. D. (2003) · Physical Review Letters · doi:10.1103/physrevlett.91.173005 · Cited by 572
Implementation of Cavity Squeezing of a Collective Atomic Spin
Leroux, I. D., Schleier-Smith, M. H., & Vuletić, V. (2010) · Physical Review Letters · doi:10.1103/physrevlett.104.073602 · Cited by 541
Making optical atomic clocks more stable with 10−16-level laser stabilization
Jiang, Y. Y., Ludlow, A. D., Lemke, N. D., Fox, R. W., Sherman, J. A., Ma, L.-S., & Oates, C. W. (2011) · Nature Photonics · doi:10.1038/nphoton.2010.313 · Cited by 462
Self-citationQuantum State Engineering and Precision Metrology Using State-Insensitive Light Traps
Ye, J., Kimble, H. J., & Katori, H. (2008) · Science · doi:10.1126/science.1148259 · Cited by 419
Tenfold reduction of Brownian noise in high-reflectivity optical coatings
Cole, G. D., Zhang, W., Martin, M. J., Ye, J., & Aspelmeyer, M. (2013) · Nature Photonics · doi:10.1038/nphoton.2013.174 · Cited by 382
New Limits on Coupling of Fundamental Constants to Gravity UsingSr87Optical Lattice Clocks
Blatt, S., Ludlow, A. D., Campbell, G. K., Thomsen, J. W., Zelevinsky, T., Boyd, M. M., Ye, J., Baillard, X., Fouché, M., Le Targat, R., et al. (2008) · Physical Review Letters · doi:10.1103/physrevlett.100.140801 · Cited by 333
Self-citationSantarelli, G., Audoin, C., Makdissi, A., Laurent, P., Dick, G. J., & Clairon, A. (1998) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.710548 · Cited by 314
Progress in atomic fountains at LNE-SYRTE
Guena, J., Abgrall, M., Rovera, D., Laurent, P., Chupin, B., Lours, M., Santarelli, G., Rosenbusch, P., Tobar, M. E., Li, R., et al. (2012) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2012.2208 · Cited by 291
Standards of Time and Frequency at the Outset of the 21st Century
Diddams, S. A., Bergquist, J. C., Jefferts, S. R., & Oates, C. W. (2004) · Science · doi:10.1126/science.1102330 · Cited by 275
Self-citationLemke, N., Ludlow, A., Barber, Z., Fortier, T., Diddams, S., Jiang, Y., Jefferts, S., Heavner, T., Parker, T., & Oates, C. (2009) · Physical Review Letters · doi:10.1103/physrevlett.103.063001 · Cited by 274
Self-citationExperimental realization of an optical second with strontium lattice clocks
Le Targat, R., Lorini, L., Le Coq, Y., Zawada, M., Guéna, J., Abgrall, M., Gurov, M., Rosenbusch, P., Rovera, D. G., Nagórny, B., et al. (2013) · Nature Communications · doi:10.1038/ncomms3109 · Cited by 250
Comparison of Two Independent Sr Optical Clocks with1×10−17Stability at103 s
Nicholson, T. L., Martin, M. J., Williams, J. R., Bloom, B. J., Bishof, M., Swallows, M. D., Campbell, S. L., & Ye, J. (2012) · Physical Review Letters · doi:10.1103/physrevlett.109.230801 · Cited by 205
Introduction to time and frequency metrology
Levine, J. (1999) · Review of Scientific Instruments · doi:10.1063/1.1149844 · Cited by 166
High-Accuracy Measurement of Atomic Polarizability in an Optical Lattice Clock
Sherman, J. A., Lemke, N., Hinkley, N., Pizzocaro, M., Fox, R. W., Ludlow, A. D., & Oates, C. W. (2012) · Physical Review Letters · doi:10.1103/physrevlett.108.153002 · Cited by 137
Self-citationEinstein Gravity Explorer–a medium-class fundamental physics mission
Schiller, S., Tino, G. M., Gill, P. R., Salomon, C., Sterr, U., Peik, E., Nevsky, A. Y., Görlitz, A., Švehla, D., Ferrari, G., et al. (2008) · Experimental Astronomy · doi:10.1007/s10686-008-9126-5 · Cited by 121
p -Wave Cold Collisions in an Optical Lattice Clock
Lemke, N., von Stecher, J., Sherman, J. A., Rey, A. M., Oates, C. W., & Ludlow, A. D. (2011) · Physical Review Letters · doi:10.1103/physrevlett.107.103902 · Cited by 101
Self-citationThe Constancy of the Constants of Nature: Updates
Chiba, T. (2011) · Progress of Theoretical Physics · doi:10.1143/ptp.126.993 · Cited by 101
Caesium atomic clocks: function, performance and applications
Bauch, A. (2003) · Measurement Science and Technology · doi:10.1088/0957-0233/14/8/301 · Cited by 97
Long-term comparison of caesium fountain primary frequency standards
Parker, T. E. (2009) · Metrologia · doi:10.1088/0026-1394/47/1/001 · Cited by 89
Total variance, an estimator of long-term frequency stability [standards]
Greenhall, C. A., Howe, D. A., & Percival, D. B. (1999) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/58.796124 · Cited by 88
Minimizing the dick effect in an optical lattice clock
Westergaard, P. G., Lodewyck, J., & Lemonde, P. (2010) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2010.1457 · Cited by 57
Kleppner, D. (2006) · Physics Today · doi:10.1063/1.2195297 · Cited by 43
Schiller, S., Görlitz, A., Nevsky, A. Y., Koelemeij, J. C. J., Wicht, A., Gill, P. R., Klein, H. A., Margolis, H. S., Mileti, G., Sterr, U., et al. (2007) · Nuclear Physics B - Proceedings Supplements · doi:10.1016/j.nuclphysbps.2006.12.032 · Cited by 40
Research works printed but not linked: 1
- G. J. Dick J. D. Prestage C. A. Greenhall L. Maleki in Proceedings of the 22nd Precise Time and Time Interval Meeting (NASA Conference Publication 3116 Washington DC 1990) pp. 487–508.
Cited by
Degen, C. L., Reinhard, F., & Cappellaro, P. (2017) · Reviews of Modern Physics · doi:10.1103/revmodphys.89.035002 · Cited by 4,045
Ludlow, A. D., Boyd, M. M., Ye, J., Peik, E., & Schmidt, P. O. (2015) · Reviews of Modern Physics · doi:10.1103/revmodphys.87.637 · Cited by 2,385
Self-citationQuantum metrology with nonclassical states of atomic ensembles
Pezzè, L., Smerzi, A., Oberthaler, M. K., Schmied, R., & Treutlein, P. (2018) · Reviews of Modern Physics · doi:10.1103/revmodphys.90.035005 · Cited by 1,682
An optical lattice clock with accuracy and stability at the 10−18 level
Bloom, B. J., Nicholson, T. L., Williams, J. R., Campbell, S. L., Bishof, M., Zhang, X., Zhang, W., Bromley, S. L., & Ye, J. (2014) · Nature · doi:10.1038/nature12941 · Cited by 1,073
Molecular spins for quantum computation
Gaita-Ariño, A., Luis, F., Hill, S., & Coronado, E. (2019) · Nature Chemistry · doi:10.1038/s41557-019-0232-y · Cited by 889
Metadata
- Authors
- Hinkley, N., Sherman, J. A., Phillips, N. B., Schioppo, M., Lemke, N. D., Beloy, K., Pizzocaro, M., Oates, C. W., & Ludlow, A. D.
- Affiliations
- National Institute of Standards and Technology (US)
- Corresponding author
- Ludlow, A. D.
- Venue
- Science
- Published
- 2013-09-13
- Volume
- 341
- Issue
- 6151
- Pages
- 1215-1218
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W2015575484
- Cited by
- 817
- References
- 28
- Citations by year
- 2026: 22 · 2025: 38 · 2024: 46 · 2023: 34 · 2022: 39 · 2021: 45 · 2020: 45 · 2019: 57 · 2018: 58 · 2017: 63 · 2016: 99 · 2015: 145 · 2014: 111 · 2013: 14
- FWCI
- 63.43
- Type
- journal article
- Language
- en
- Open access
- green
- arxiv.org
- Locations
- Science (publishedVersion)
- PubMed (publishedVersion)
- arXiv (Cornell University) (submittedVersion)
- CINECA IRIS Institutional Research Information System (IRIS Istituto Nazionale di Ricerca Metrologica) (submittedVersion)
- arXiv (Cornell University) (public-domain)
- Science
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Frequency and Time Standards
- Physical Sciences › Computer Science › Computer Networks and Communications › Network Time Synchronization Technologies
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Cold Atom Physics and Bose-Einstein Condensates
- Keywords
- optical lattice clock, ytterbium, relativistic geodesy, navigation, beyond the Standard Model
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.