A QUASI-PASSIVE LEG EXOSKELETON FOR LOAD-CARRYING AUGMENTATION
The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
A quasi-passive leg exoskeleton is presented for load-carrying augmentation during walking. The exoskeleton has no actuators, only ankle and hip springs and a knee variable-damper. Without a payload, the exoskeleton weighs 11.7 kg and requires only 2 Watts of electrical power during loaded walking. For a 36 kg payload, we demonstrate that the quasi-passive exoskeleton transfers on average 80% of the load to the ground during the single support phase of walking. By measuring the rate of oxygen consumption on a study participant walking at a self-selected speed, we find that the exoskeleton slightly increases the walking metabolic cost of transport (COT) as compared to a standard loaded backpack (10% increase). However, a similar exoskeleton without joint springs or damping control (zero-impedance exoskeleton) is found to increase COT by 23% compared to the loaded backpack, highlighting the benefits of passive and quasi-passive joint mechanisms in the design of efficient, low-mass leg exoskeletons.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
McGeer, T. (1990) · The International Journal of Robotics Research · doi:10.1177/027836499000900206 · Cited by 3,359
Compliant leg behaviour explains basic dynamics of walking and running
Geyer, H., Seyfarth, A., & Blickhan, R. (2006) · Proceedings of the Royal Society B: Biological Sciences · doi:10.1098/rspb.2006.3637 · Cited by 940
Mechanical work and efficiency in level walking and running
Cavagna, G. A., & Kaneko, M. (1977) · The Journal of Physiology · doi:10.1113/jphysiol.1977.sp011866 · Cited by 664
Derivation of formulae used to calculate energy expenditure in man.
Brockway, J. M. (1987) · PubMed · Cited by 585
The RoboKnee: an exoskeleton for enhancing strength and endurance during walking
Pratt, J. E., Krupp, B. T., Morse, C. J., & Collins, S. H. (2004) · IEEE International Conference on Robotics and Automation, 2004. Proceedings. ICRA '04. 2004 · doi:10.1109/robot.2004.1307425 · Cited by 567
Mochon, S., & McMahon, T. A. (1980) · Journal of Biomechanics · doi:10.1016/0021-9290(80)90007-x · Cited by 505
McMahon, T. A., Valiant, G., & Frederick, E. C. (1987) · Journal of Applied Physiology · doi:10.1152/jappl.1987.62.6.2326 · Cited by 451
Biped Locomotion: Dynamics, Stability, Control and Application
VUKOBRATOVIC, M. K. (1990) · Cited by 398
User‐adaptive control of a magnetorheological prosthetic knee
Herr, H., & Wilkenfeld, A. (2003) · Industrial Robot: An International Journal · doi:10.1108/01439910310457706 · Cited by 293
Self-citationOn the Biomimetic Design of the Berkeley Lower Extremity Exoskeleton (BLEEX)
Chu, A., Kazerooni, H., & Zoss, A. (2006) · Proceedings of the 2005 IEEE International Conference on Robotics and Automation · doi:10.1109/robot.2005.1570789 · Cited by 258
Cited by
Lower Extremity Exoskeletons and Active Orthoses: Challenges and State-of-the-Art
Dollar, A. M., & Herr, H. (2008) · IEEE Transactions on Robotics · doi:10.1109/tro.2008.915453 · Cited by 1,327
Self-citationReview of assistive strategies in powered lower-limb orthoses and exoskeletons
Yan, T., Cempini, M., Oddo, C. M., & Vitiello, N. (2015) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2014.09.032 · Cited by 715
Recent developments and challenges of lower extremity exoskeletons
Chen, B., Ma, H., Qin, L.-Y., Gao, F., Chan, K.-M., Law, S.-W., Qin, L., & Liao, W.-H. (2016) · Journal of Orthopaedic Translation · doi:10.1016/j.jot.2015.09.007 · Cited by 501
“…by Wehner et al [48] at Harvard University (Cambridge, MA, USA) to augment normal muscle function in healthy individuals; and an under-actuated leg exoskeleton for load-carrying augmentation was developed by the Massachusetts Institute of Technology Media Laboratory (Cambridge, MA, USA) [49,50].”
MethodBiorobotics: Using robots to emulate and investigate agile locomotion
Ijspeert, A. J. (2014) · Science · doi:10.1126/science.1254486 · Cited by 491
Exoskeletons and orthoses: classification, design challenges and future directions
Herr, H. (2009) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-6-21 · Cited by 477
Self-citationAutonomous exoskeleton reduces metabolic cost of human walking during load carriage
Mooney, L. M., Rouse, E. J., & Herr, H. M. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-80 · Cited by 461
Self-citationA biologically inspired soft exosuit for walking assistance
Asbeck, A. T., De Rossi, S. M. M., Holt, K. G., & Walsh, C. J. (2015) · The International Journal of Robotics Research · doi:10.1177/0278364914562476 · Cited by 450
“These devices off-load the wearer, bypassing their musculature (Garcia et al., 2002; Kazerooni and Steger, 2006; Walsh et al., 2007).”
BackgroundSelf-citationA Simple Exoskeleton That Assists Plantarflexion Can Reduce the Metabolic Cost of Human Walking
Malcolm, P., Derave, W., Galle, S., & De Clercq, D. (2013) · PLoS ONE · doi:10.1371/journal.pone.0056137 · Cited by 428
The exoskeleton expansion: improving walking and running economy
Sawicki, G. S., Beck, O. N., Kang, I., & Young, A. J. (2020) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-020-00663-9 · Cited by 424
Wearable soft sensing suit for human gait measurement
Mengüç, Y., Park, Y.-L., Pei, H., Vogt, D., Aubin, P. M., Winchell, E., Fluke, L., Stirling, L., Wood, R. J., & Walsh, C. J. (2014) · The International Journal of Robotics Research · doi:10.1177/0278364914543793 · Cited by 415
Self-citationIntention-Based EMG Control for Powered Exoskeletons
Lenzi, T., De Rossi, S. M. M., Vitiello, N., & Carrozza, M. C. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2198821 · Cited by 400
Assistance magnitude versus metabolic cost reductions for a tethered multiarticular soft exosuit
Quinlivan, B. T., Lee, S., Malcolm, P., Rossi, D. M., Grimmer, M., Siviy, C., Karavas, N., Wagner, D., Asbeck, A., Galiana, I., et al. (2017) · Science Robotics · doi:10.1126/scirobotics.aah4416 · Cited by 370
Self-citationStronger, Smarter, Softer: Next-Generation Wearable Robots
Asbeck, A. T., De Rossi, S. M. M., Galiana, I., Ding, Y., & Walsh, C. J. (2014) · IEEE Robotics & Automation Magazine · doi:10.1109/mra.2014.2360283 · Cited by 368
Self-citationA lightweight soft exosuit for gait assistance
Wehner, M., Quinlivan, B., Aubin, P. M., Martinez-Villalpando, E., Baumann, M., Stirling, L., Holt, K., Wood, R., & Walsh, C. (2013) · 2013 IEEE International Conference on Robotics and Automation · doi:10.1109/icra.2013.6631046 · Cited by 361
Self-citationA biologically-inspired multi-joint soft exosuit that can reduce the energy cost of loaded walking
Panizzolo, F. A., Galiana, I., Asbeck, A. T., Siviy, C., Schmidt, K., Holt, K. G., & Walsh, C. J. (2016) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-016-0150-9 · Cited by 291
Self-citationA light-weight active orthosis for hip movement assistance
Giovacchini, F., Vannetti, F., Fantozzi, M., Cempini, M., Cortese, M., Parri, A., Yan, T., Lefeber, D., & Vitiello, N. (2015) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2014.08.015 · Cited by 258
Effect of timing of hip extension assistance during loaded walking with a soft exosuit
Ding, Y., Panizzolo, F. A., Siviy, C., Malcolm, P., Galiana, I., Holt, K. G., & Walsh, C. J. (2016) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-016-0196-8 · Cited by 249
“Exoskeletons have been designed to augment the performance of human locomotion for able-bodied individuals [1–13] or to assist patients affected by different pathologies in rehabilitation and daily activities [14–25].”
Self-citationA pneumatically powered knee-ankle-foot orthosis (KAFO) with myoelectric activation and inhibition
Sawicki, G. S., & Ferris, D. P. (2009) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-6-23 · Cited by 248
Biologically-inspired soft exosuit
Asbeck, A. T., Dyer, R. J., Larusson, A. F., & Walsh, C. J. (2013) · 2013 IEEE 13th International Conference on Rehabilitation Robotics (ICORR) · doi:10.1109/icorr.2013.6650455 · Cited by 240
“In two human subjects studies with a leg exoskeleton for load carrying, significant off-loading was demonstrated [12, 26]; however, at the cost of an increased metabolic effort to walk.”
BackgroundSelf-citationRupal, B. S., Rafique, S., Singla, A., Singla, E., Isaksson, M., & Virk, G. S. (2017) · International Journal of Advanced Robotic Systems · doi:10.1177/1729881417743554 · Cited by 228
Compliant lower limb exoskeletons: a comprehensive review on mechanical design principles
Sanchez-Villamañan, M. D. C., Gonzalez-Vargas, J., Torricelli, D., Moreno, J. C., & Pons, J. L. (2019) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-019-0517-9 · Cited by 224
Biomechanical and Physiological Evaluation of Multi-Joint Assistance With Soft Exosuits
Ding, Y., Galiana, I., Asbeck, A. T., De Rossi, S. M. M., Bae, J., Santos, T. R. T., de Araujo, V. L., Lee, S., Holt, K. G., & Walsh, C. (2017) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2523250 · Cited by 217
“Some wearable robots have been designed to augment the locomotion performance of able-bodied individuals through enabling wearers to spend less energy or carry an increased load [2]–[6], while others have been designed to enable individuals to walk if they were not able to previously [7]–[9], or supplement rehabilitat…”
BackgroundSelf-citationDevelopment of Active Lower Limb Robotic-Based Orthosis and Exoskeleton Devices: A Systematic Review
Kalita, B., Narayan, J., & Dwivedy, S. K. (2021) · International Journal of Social Robotics · doi:10.1007/s12369-020-00662-9 · Cited by 203
The technical trend of the exoskeleton robot system for human power assistance
Lee, H., Kim, W., Han, J., & Han, C. (2012) · International Journal of Precision Engineering and Manufacturing · doi:10.1007/s12541-012-0197-x · Cited by 196
Oscillator-based assistance of cyclical movements: model-based and model-free approaches
Ronsse, R., Lenzi, T., Vitiello, N., Koopman, B., van Asseldonk, E., De Rossi, S. M. M., van den Kieboom, J., van der Kooij, H., Carrozza, M. C., & Ijspeert, A. J. (2011) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-011-0816-1 · Cited by 188
“These results are however encouraging, and they have to be balanced with the literature illustrating the challenge related to reduce the metabolic cost of free walking with an assistive device [9, 37, 38, 51].”
BackgroundSoft exosuit for hip assistance
Asbeck, A. T., Schmidt, K., & Walsh, C. J. (2015) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2014.09.025 · Cited by 167
“[1, 2, 3, 4], while others support a paraplegic’s bodyweight [5, 6, 7, 8, 9, 10].”
BackgroundSelf-citationAo, D., Song, R., & Gao, J. (2017) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2583464 · Cited by 166
Lee, S., Kim, J., Baker, L., Long, A., Karavas, N., Menard, N., Galiana, I., & Walsh, C. J. (2018) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-018-0410-y · Cited by 166
Self-citationHuman–Robot Synchrony: Flexible Assistance Using Adaptive Oscillators
Ronsse, R., Vitiello, N., Lenzi, T., van den Kieboom, J., Carrozza, M. C., & Ijspeert, A. J. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2089629 · Cited by 158
“similar performances [2], [20], [47], [48].”
Näf, M. B., Junius, K., Rossini, M., Rodriguez-Guerrero, C., Vanderborght, B., & Lefeber, D. (2018) · Applied Mechanics Reviews · doi:10.1115/1.4042523 · Cited by 158
High Force Density Textile Electrostatic Clutch
Hinchet, R., & Shea, H. (2020) · Advanced Materials Technologies · doi:10.1002/admt.201900895 · Cited by 132
Recognition of walking environments and gait period by surface electromyography
Kyeong, S., Shin, W., Yang, M., Heo, U., Feng, J.-R., & Kim, J. (2019) · Frontiers of Information Technology & Electronic Engineering · doi:10.1631/fitee.1800601 · Cited by 68
Oscillator-based walking assistance: A model-free approach
Ronsse, R., Koopman, B., Vitiello, N., Lenzi, T., De Rossi, S. M. M., van den Kieboom, J., van Asseldonk, E., Carrozza, M. C., van der Kooij, H., & Ijspeert, A. J. (2011) · 2011 IEEE International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2011.5975352 · Cited by 50
“All in all, we think that the present results are encouraging, given the challenge related to reduce the metabolic cost of free walking with an assistive device, as reported in the literature [11], [30].”
ResultDesign of an under-actuated exoskeleton system for walking assist while load carrying
Yu, S. N., Lee, H. D., Lee, S. H., Kim, W. S., Han, J. S., & Han, C. S. (2012) · Advanced Robotics · doi:10.1163/156855311x617506 · Cited by 37
The Apollo number: space suits, self-support, and the walk-run transition
Carr, C. E., & McGee, J. (2009) · PLoS ONE · doi:10.1371/journal.pone.0006614 · Cited by 26
“A third prediction relates to changes in the walk-run transition when humans use exoskeletons with external load paths, such as those under consideration for load-carrying”
Background
Metadata
- Authors
- WALSH, C. J., ENDO, K., & HERR, H.
- Venue
- International Journal of Humanoid Robotics
- Publisher
- World Scientific Pub Co Pte Lt
- Published
- 2007-09
- Volume
- 04
- Issue
- 03
- Pages
- 487-506
- ISSN
- 0219-8436 (ISSN-L)
- 1793-6942
- OpenAlex
- W2015244452
- Cited by
- 427
- References
- 21
- FWCI
- 4.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.